Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nina Tandon is active.

Publication


Featured researches published by Nina Tandon.


Nature Protocols | 2009

Electrical stimulation systems for cardiac tissue engineering

Nina Tandon; Christopher Cannizzaro; Pen-hsiu Grace Chao; Robert Maidhof; Anna Marsano; Hoi Ting Heidi Au; Milica Radisic; Gordana Vunjak-Novakovic

We describe a protocol for tissue engineering of synchronously contractile cardiac constructs by culturing cardiac cells with the application of pulsatile electrical fields designed to mimic those present in the native heart. Tissue culture is conducted in a customized chamber built to allow for cultivation of (i) engineered three-dimensional (3D) cardiac tissue constructs, (ii) cell monolayers on flat substrates or (iii) cells on patterned substrates. This also allows for analysis of the individual and interactive effects of pulsatile electrical field stimulation and substrate topography on cell differentiation and assembly. The protocol is designed to allow for delivery of predictable electrical field stimuli to cells, monitoring environmental parameters, and assessment of cell and tissue responses. The duration of the protocol is 5 d for two-dimensional cultures and 10 d for 3D cultures.


Experimental Cell Research | 2009

Electrical stimulation of human embryonic stem cells: Cardiac differentiation and the generation of reactive oxygen species

Elena Serena; Elisa Figallo; Nina Tandon; Christopher Cannizzaro; Sharon Gerecht; Nicola Elvassore; Gordana Vunjak-Novakovic

Exogenous electric fields have been implied in cardiac differentiation of mouse embryonic stem cells and the generation of reactive oxygen species (ROS). In this work, we explored the effects of electrical field stimulation on ROS generation and cardiogenesis in embryoid bodies (EBs) derived from human embryonic stem cells (hESC, line H13), using a custom-built electrical stimulation bioreactor. Electrical properties of the bioreactor system were characterized by electrochemical impedance spectroscopy (EIS) and analysis of electrical currents. The effects of the electrode material (stainless steel, titanium-nitride-coated titanium, titanium), length of stimulus (1 and 90 s) and age of EBs at the onset of electrical stimulation (4 and 8 days) were investigated with respect to ROS generation. The amplitude of the applied electrical field was 1 V/mm. The highest rate of ROS generation was observed for stainless steel electrodes, for signal duration of 90 s and for 4-day-old EBs. Notably, comparable ROS generation was achieved by incubation of EBs with 1 nM H(2)O(2). Cardiac differentiation in these EBs was evidenced by spontaneous contractions, expression of troponin T and its sarcomeric organization. These results imply that electrical stimulation plays a role in cardiac differentiation of hESCs, through mechanisms associated with the intracellular generation of ROS.


Journal of Tissue Engineering and Regenerative Medicine | 2011

Optimization of electrical stimulation parameters for cardiac tissue engineering.

Nina Tandon; Anna Marsano; Robert Maidhof; Leo Q. Wan; Hyoungshin Park; Gordana Vunjak-Novakovic

In vitro application of pulsatile electrical stimulation to neonatal rat cardiomyocytes cultured on polymer scaffolds has been shown to improve the functional assembly of cells into contractile engineered cardiac tissues. However, to date, the conditions of electrical stimulation have not been optimized. We have systematically varied the electrode material, amplitude and frequency of stimulation to determine the conditions that are optimal for cardiac tissue engineering. Carbon electrodes, exhibiting the highest charge‐injection capacity and producing cardiac tissues with the best structural and contractile properties, were thus used in tissue engineering studies. Engineered cardiac tissues stimulated at 3 V/cm amplitude and 3 Hz frequency had the highest tissue density, the highest concentrations of cardiac troponin‐I and connexin‐43 and the best‐developed contractile behaviour. These findings contribute to defining bioreactor design specifications and electrical stimulation regime for cardiac tissue engineering. Copyright


Journal of Tissue Engineering and Regenerative Medicine | 2012

Biomimetic perfusion and electrical stimulation applied in concert improved the assembly of engineered cardiac tissue

Robert Maidhof; Nina Tandon; Eun Jung Lee; Jianwen Luo; Yi Duan; Keith Yeager; Elisa E. Konofagou; Gordana Vunjak-Novakovic

Maintenance of normal myocardial function depends intimately on synchronous tissue contraction, driven by electrical activation and on adequate nutrient perfusion in support thereof. Bioreactors have been used to mimic aspects of these factors in vitro to engineer cardiac tissue but, due to design limitations, previous bioreactor systems have yet to simultaneously support nutrient perfusion, electrical stimulation and unconstrained (i.e. not isometric) tissue contraction. To the best of our knowledge, the bioreactor system described herein is the first to integrate these three key factors in concert. We present the design of our bioreactor and characterize its capability in integrated experimental and mathematical modelling studies. We then cultured cardiac cells obtained from neonatal rats in porous, channelled elastomer scaffolds with the simultaneous application of perfusion and electrical stimulation, with controls excluding either one or both of these two conditions. After 8 days of culture, constructs grown with simultaneous perfusion and electrical stimulation exhibited substantially improved functional properties, as evidenced by a significant increase in contraction amplitude (0.23 ± 0.10% vs 0.14 ± 0.05%, 0.13 ± 0.08% or 0.09 ± 0.02% in control constructs grown without stimulation, without perfusion, or either stimulation or perfusion, respectively). Consistently, these constructs had significantly improved DNA contents, cell distribution throughout the scaffold thickness, cardiac protein expression, cell morphology and overall tissue organization compared to control groups. Thus, the simultaneous application of medium perfusion and electrical conditioning enabled by the use of the novel bioreactor system may accelerate the generation of fully functional, clinically sized cardiac tissue constructs. Copyright


Biotechnology Progress | 2010

Scaffold stiffness affects the contractile function of three-dimensional engineered cardiac constructs

Anna Marsano; Robert Maidhof; Leo Q. Wan; Yadong Wang; Jin Gao; Nina Tandon; Gordana Vunjak-Novakovic

We investigated the effects of the initial stiffness of a three‐dimensional elastomer scaffold—highly porous poly(glycerol sebacate)—on functional assembly of cardiomyocytes cultured with perfusion for 8 days. The polymer elasticity varied with the extent of polymer cross‐links, resulting in three different stiffness groups, with compressive modulus of 2.35 ± 0.03 (low), 5.28 ± 0.36 (medium), and 5.99 ± 0.40 (high) kPa. Laminin coating improved the efficiency of cell seeding (from 59 ± 15 to 90 ± 21%), resulting in markedly increased final cell density, construct contractility, and matrix deposition, likely because of enhanced cell interaction and spreading on scaffold surfaces. Compact tissue was formed in the low and medium stiffness groups, but not in the high stiffness group. In particular, the low stiffness group exhibited the greatest contraction amplitude in response to electric field pacing, and had the highest compressive modulus at the end of culture. A mathematical model was developed to establish a correlation between the contractile amplitude and the cell distribution within the scaffold. Taken together, our findings suggest that the contractile function of engineered cardiac constructs positively correlates with low compressive stiffness of the scaffold.


Biotechnology Advances | 2013

Bioreactor engineering of stem cell environments

Nina Tandon; Darja Marolt; Elisa Cimetta; Gordana Vunjak-Novakovic

Stem cells hold promise to revolutionize modern medicine by the development of new therapies, disease models and drug screening systems. Standard cell culture systems have limited biological relevance because they do not recapitulate the complex 3-dimensional interactions and biophysical cues that characterize the in vivo environment. In this review, we discuss the current advances in engineering stem cell environments using novel biomaterials and bioreactor technologies. We also reflect on the challenges the field is currently facing with regard to the translation of stem cell based therapies into the clinic.


international conference of the ieee engineering in medicine and biology society | 2009

Alignment and elongation of human adipose-derived stem cells in response to direct-current electrical stimulation

Nina Tandon; Brian C. Goh; Anna Marsano; Pen-hsiu Grace Chao; Chrystina Montouri-Sorrentino; Jeffrey M. Gimble; Gordana Vunjak-Novakovic

In vivo, direct current electric fields are present during embryonic development and wound healing. In vitro, direct current (DC) electric fields induce directional cell migration and elongation. For the first time, we demonstrate that cultured human adipose tissue-derived stem cells (hASCs) respond to the presence of direct-current electric fields. Cells were stimulated for 2-4 hours with DC electric fields of 6 V/cm that were similar to those encountered in vivo post-injury. Upon stimulation, hASCs were observed to elongate and align perpendicularly to the applied electric field, disassemble gap junctions, and upregulate the expression of genes for connexin-43, thrombomodulin, vascular endothelial growth factor, and fibroblast growth factor. In separate related studies, human epicardial fat-derived stem cells (heASCs) were also observed to align and elongate. It is interesting that the morphological and phenotypic characteristics of mesenchymal stem cells derived both from liposuction aspirates and from cardiac fat can be modulated by direct current electric fields. In further studies, we will quantify the effects of the electrical fields in the context of wound healing.


international conference of the ieee engineering in medicine and biology society | 2006

Characterization of Electrical Stimulation Electrodes for Cardiac Tissue Engineering

Nina Tandon; Chris Cannizzaro; Elisa Figallo; Joel Voldman; Gordana Vunjak-Novakovic

Electrical stimulation has been shown to improve functional assembly of cardiomyocytes in vitro for cardiac tissue engineering. The goal of this study was to assess the conditions of electrical stimulation with respect to the electrode geometry, material properties and charge-transfer characteristics at the electrode-electrolyte interface. We compared various biocompatible materials, including nanoporous carbon, stainless steel, titanium and titanium nitride, for use in cardiac tissue engineering bioreactors. The faradaic and non-faradaic charge transfer mechanisms were assessed by electrochemical impedance spectroscopy (EIS), studying current injection characteristics, and examining surface properties of electrodes with scanning electron microscopy. Carbon electrodes were found to have the best current injection characteristics. However, these electrodes require careful handling because of their limited mechanical strength. The efficacy of various electrodes for use in 2-D and 3-D cardiac tissue engineering systems with neonatal rat cardiomyocytes is being determined by assessing cell viability, amplitude of contractions, excitation thresholds, maximum capture rate, and tissue morphology


international conference of the ieee engineering in medicine and biology society | 2008

Design of electrical stimulation bioreactors for cardiac tissue engineering

Nina Tandon; Anna Marsano; Christopher Cannizzaro; Joel Voldman; Gordana Vunjak-Novakovic

Electrical stimulation has been shown to improve functional assembly of cardiomyocytes in vitro for cardiac tissue engineering. Carbon electrodes were found in past studies to have the best current injection characteristics. The goal of this study was to develop rational experimental design principles for the electrodes and stimulation regime, in particular electrode configuration, electrode ageing, and stimulation amplitude. Carbon rod electrodes were compared via electrochemical impedance spectroscopy (EIS) and we identified a safety range of 0 to 8 V/cm by comparing excitation thresholds and maximum capture rates for neonatal rat cardiomyocytes cultured with electrical stimulation. We conclude with recommendations for studies involving carbon electrodes for cardiac tissue engineering.


Experimental Cell Research | 2014

Galvanic microparticles increase migration of human dermal fibroblasts in a wound-healing model via reactive oxygen species pathway

Nina Tandon; Elisa Cimetta; Aranzazu Villasante; Nicolette Kupferstein; Michael Southall; Ali Fassih; Junxia Xie; Ying Sun; Gordana Vunjak-Novakovic

Electrical signals have been implied in many biological mechanisms, including wound healing, which has been associated with transient electrical currents not present in intact skin. One method to generate electrical signals similar to those naturally occurring in wounds is by supplementation of galvanic particles dispersed in a cream or gel. We constructed a three-layered model of skin consisting of human dermal fibroblasts in hydrogel (mimic of dermis), a hydrogel barrier layer (mimic of epidermis) and galvanic microparticles in hydrogel (mimic of a cream containing galvanic particles applied to skin). Using this model, we investigated the effects of the properties and amounts of Cu/Zn galvanic particles on adult human dermal fibroblasts in terms of the speed of wound closing and gene expression. The collected data suggest that the effects on wound closing are due to the ROS-mediated enhancement of fibroblast migration, which is in turn mediated by the BMP/SMAD signaling pathway. These results imply that topical low-grade electric currents via microparticles could enhance wound healing.

Collaboration


Dive into the Nina Tandon's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joel Voldman

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge