Nitika Pant Pai
McGill University Health Centre
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Nitika Pant Pai.
PLOS Medicine | 2012
Nitika Pant Pai; Caroline Vadnais; Claudia M. Denkinger; Nora Engel; Madhukar Pai
Madhukar Pai and colleagues discuss a framework for envisioning how point-of-care testing can be applied to infectious diseases in low- and middle-income countries.
PLOS Medicine | 2013
Nitika Pant Pai; Jigyasa Sharma; Sushmita Shivkumar; Sabrina Pillay; Caroline Vadnais; Lawrence Joseph; Keertan Dheda; Rosanna W. Peeling
By systematically reviewing the literature, Nitika Pant Pai and colleagues assess the evidence base for HIV self tests both with and without supervision.
Lancet Infectious Diseases | 2012
Nitika Pant Pai; Bhairavi Balram; Sushmita Shivkumar; Jorge L. Martinez-Cajas; Christiane Claessens; Gilles Lambert; Rosanna W. Peeling; Lawrence Joseph
BACKGROUND The focus on prevention strategies aimed at curbing the HIV epidemic is growing, and therefore screening for HIV has again taken centre stage. Our aim was to establish whether a convenient, non-invasive, HIV test that uses oral fluid was accurate by comparison with the same test with blood-based specimens. METHODS We did a systematic review and meta-analysis to compare the diagnostic accuracy of a rapid HIV-antibody-based point-of-care test (Oraquick advance rapid HIV-1/2, OraSure Technologies Inc, PA, USA) when used with oral versus blood-based specimens in adults. We searched five databases of published work and databases of five key HIV conferences. Studies we deemed eligible were those focused on adults at risk of HIV; we excluded studies in children, in co-infected populations, with self-reported inferior reference standards, and with incomplete reporting of key data items. We assessed the diagnostic accuracy of testing with oral and blood-based specimens with bivariate regression analysis. We computed positive predictive values (PPVs) in high-prevalence and low-prevalence settings with Bayesian methods. FINDINGS In a direct head-to-head comparison of studies, we identified a pooled sensitivity about 2% lower in oral (98·03%, 95% CI 95·85-99·08) than in blood-based specimens (99·68%, 97·31-99·96), but similar specificity (oral 99·74%, 99·47-99·88; blood 99·91%, 99·84-99·95). Negative likelihood ratios were small and similar (oral 0·019, 0.009-0·040; blood 0·003, 0·001-0·034), but positive likelihood ratios differed (oral 383·37, 183·87-799·31; blood 1105·16, 633·14-2004·37). Although in high-prevalence settings PPVs were similar (oral 98·65%, 95% credible interval 85·71-99·94; blood 98·50, 93·10-99·79), in low-prevalence settings PPVs were lower for oral (88·55%, 77·31-95·87) than blood (97·65%, 95·48-99·09) specimens. INTERPRETATION Although Oraquick had a high PPV in high-prevalence settings in oral specimens, the slightly lower sensitivity and PPV in low-prevalence settings in oral specimens should be carefully reviewed when planning worldwide expanded initiatives with this popular test.
Sexually Transmitted Infections | 2012
Sean Yaphe; Nikki Bozinoff; Rachel Kyle; Sushmita Shivkumar; Nitika Pant Pai; Marina B. Klein
Background A recent increase in reports of acute hepatitis C virus infection (HCV) in HIV-infected and HIV-uninfected men who have sex with men (MSM), with the sole risk factor being sexual exposure, has led to routine screening and targeted prevention requests for this population; current evidence for this necessity is unclear. Objective A systematic review was conducted to assess the incidence of HCV infection among studies conducted in HIV-positive and/or HIV-negative MSM to explore the implications for routine HCV screening. Data sources The MEDLINE, EMBASE and BIOSYS databases were searched for the period January 2000 to May 2012, yielding 21 studies. Six conferences were hand-searched for the same period yielding four abstracts. Study selection Only studies in English presenting incidence rates of HCV and specifying HIV status were included. Data abstraction Data were abstracted by two authors using predefined data fields. The STROBE checklist was used to assess study quality. Data synthesis Data were divided into HIV-negative MSM and HIV-positive MSM subgroups, and HCV incidence density measurements were pooled. Using a DerSimonian–Laird random effects model, pooled incidence was 1.48/1000 person-years (95% CI 0.75 to 2.21) for the HIV-negative MSM subgroup. The HIV-positive MSM subgroup was at 4.1 times higher risk of acquiring HCV at 6.08/1000 person-years (95% CI 5.18 to 6.99). Studies directly comparing subgroups estimated a pooled risk difference of 3.45/1000 person-years (95% CI 1.63 to 5.27). Conclusion HIV-positive MSM were at higher risk for acute HCV infection than HIV-negative MSM, substantiating the need for routine screening initiatives. Insufficient evidence exists to warrant routine screening of HIV-negative MSM, except on a case-by-case basis, such as high-risk sexual behaviour.
Journal of the International AIDS Society | 2009
Jorge L. Martinez-Cajas; Nitika Pant Pai; Marina B. Klein; Mark A. Wainberg
Ninety percent of HIV-1-infected people worldwide harbour non-subtype B variants of HIV-1. Yet knowledge of resistance mutations in non-B HIV-1 and their clinical relevance is limited. Although a few reviews, editorials and perspectives have been published alluding to this lack of data among non-B subtypes, no systematic review has been performed to date.With this in mind, we conducted a systematic review (1996–2008) of all published studies performed on the basis of non-subtype B HIV-1 infections treated with antiretroviral drugs that reported genotype resistance tests. Using an established search string, 50 studies were deemed relevant for this review.These studies reported genotyping data from non-B HIV-1 infections that had been treated with either reverse transcriptase inhibitors or protease inhibitors. While most major resistance mutations in subtype B were also found in non-B subtypes, a few novel mutations in non-B subtypes were recognized. The main differences are reflected in the discoveries that: (i) the non-nucleoside reverse transcriptase inhibitor resistance mutation, V106M, has been seen in subtype C and CRF01_AE, but not in subtype B, (ii) the protease inhibitor mutations L89I/V have been reported in C, F and G subtypes, but not in B, (iii) a nelfinavir selected non-D30N containing pathway predominated in CRF01_AE and CRF02_AG, while the emergence of D30N is favoured in subtypes B and D, (iv) studies on thymidine analog-treated subtype C infections from South Africa, Botswana and Malawi have reported a higher frequency of the K65R resistance mutation than that typically seen with subtype B.Additionally, some substitutions that seem to impact non-B viruses differentially are: reverse transcriptase mutations G196E, A98G/S, and V75M; and protease mutations M89I/V and I93L.Polymorphisms that were common in non-B subtypes and that may contribute to resistance tended to persist or become more frequent after drug exposure. Some, but not all, are recognized as minor resistance mutations in B subtypes. These observed differences in resistance pathways may impact cross-resistance and the selection of second-line regimens with protease inhibitors. Attention to newer drug combinations, as well as baseline genotyping of non-B isolates, in well-designed longitudinal studies with long duration of follow up are needed.
PLOS ONE | 2013
Yalda Jafari; Rosanna W. Peeling; Sushmita Shivkumar; Christiane Claessens; Lawrence Joseph; Nitika Pant Pai
Background Rapid and point-of-care (POC) tests for syphilis are an invaluable screening tool, yet inadequate evaluation of their diagnostic accuracy against best reference standards limits their widespread global uptake. To fill this gap, a systematic review and meta-analysis was conducted to evaluate the sensitivity and specificity of rapid and POC tests in blood and serum samples against Treponema pallidum (TP) specific reference standards. Methods Five electronic databases (1980–2012) were searched, data was extracted from 33 articles, and Bayesian hierarchical models were fit. Results In serum samples, against a TP specific reference standard point estimates with 95% credible intervals (CrI) for the sensitivities of popular tests were: i) Determine, 90.04% (80.45, 95.21), ii) SD Bioline, 87.06% (75.67, 94.50), iii) VisiTect, 85.13% (72.83, 92.57), and iv) Syphicheck, 74.48% (56.85, 88.44), while specificities were: i) Syphicheck, 99.14% (96.37, 100), ii) Visitect, 96.45% (91.92, 99.29), iii) SD Bioline, 95.85% (89.89, 99.53), and iv) Determine, 94.15% (89.26, 97.66). In whole blood samples, sensitivities were: i) Determine, 86.32% (77.26, 91.70), ii) SD Bioline, 84.50% (78.81, 92.61), iii) Syphicheck, 74.47% (63.94, 82.13), and iv) VisiTect, 74.26% (53.62, 83.68), while specificities were: i) Syphicheck, 99.58% (98.91, 99.96), ii) VisiTect, 99.43% (98.22, 99.98), iii) SD Bioline, 97.95%(92.54, 99.33), and iv) Determine, 95.85% (92.42, 97.74). Conclusions Rapid and POC treponemal tests reported sensitivity and specificity estimates comparable to laboratory-based treponemal tests. In resource limited settings, where access to screening is limited and where risk of patients lost to follow up is high, the introduction of these tests has already been shown to improve access to screening and treatment to prevent stillbirths and neonatal mortality due to congenital syphilis. Based on the evidence, it is concluded that rapid and POC tests are useful in resource limited settings with poor access to laboratories or screening for syphilis.
PLOS ONE | 2009
Patricia S. Fontela; Nitika Pant Pai; Ian Schiller; Nandini Dendukuri; Andrew Ramsay; Madhukar Pai
Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.
Tropical Medicine & International Health | 2007
Nitika Pant Pai; Jacqueline P. Tulsky; Deborah Cohan; John M. Colford; Arthur L. Reingold
Rapid, point‐of‐care human immunodeficiency virus (HIV) testing has the potential to enhance strategies to prevent mother‐to‐child transmission (MTCT) of HIV infection. Rapid tests need minimal laboratory infrastructure and can be performed by health workers with minimal training. In our systematic review and meta‐analysis, we aimed to summarize the overall diagnostic accuracy of rapid HIV tests in pregnancy, and outcomes such as acceptability, patient preference, feasibility and impact of rapid testing. We searched four major databases, identified and screened 1377 citations, and included 17 studies that met our eligibility criteria. Analyses of these studies suggested that the overall sensitivity and specificity of blood‐based rapid tests was high compared with oral rapid tests. A two‐step testing strategy, particularly parallel testing, was found to be superior to single‐test strategy in labour and delivery settings. Acceptability of rapid tests and patient preference was variable across studies. Overall, rapid HIV testing was highly accurate compared with conventional tests and offer a clear advantage of enabling the implementation of timely interventions to reduce MTCT of HIV. To improve diagnostic accuracy and to reduce false‐positive results, it may be necessary to use two rapid tests during labour and delivery.
PLOS Medicine | 2008
Nitika Pant Pai; Ritu Barick; Jacqueline P. Tulsky; Poonam V Shivkumar; Deborah Cohan; Shriprakash Kalantri; Madhukar Pai; Marina B Klein; Shakuntala Chhabra
Background Testing pregnant women for HIV at the time of labor and delivery is the last opportunity for prevention of mother-to-child HIV transmission (PMTCT) measures, particularly in settings where women do not receive adequate antenatal care. However, HIV testing and counseling of pregnant women in labor is a challenge, especially in resource-constrained settings. In India, many rural women present for delivery without any prior antenatal care. Those who do get antenatal care are not always tested for HIV, because of deficiencies in the provision of HIV testing and counseling services. In this context, we investigated the impact of introducing round-the-clock, rapid, point-of-care HIV testing and counseling in a busy labor ward at a tertiary care hospital in rural India. Methods and Findings After they provided written informed consent, women admitted to the labor ward of a rural teaching hospital in India were offered two rapid tests on oral fluid and finger-stick specimens (OraQuick Rapid HIV-1/HIV-2 tests, OraSure Technologies). Simultaneously, venous blood was drawn for conventional HIV ELISA testing. Western blot tests were performed for confirmatory testing if women were positive by both rapid tests and dual ELISA, or where test results were discordant. Round-the-clock (24 h, 7 d/wk) abbreviated prepartum and extended postpartum counseling sessions were offered as part of the testing strategy. HIV-positive women were administered PMTCT interventions. Of 1,252 eligible women (age range 18 y to 38 y) approached for consent over a 9 mo period in 2006, 1,222 (98%) accepted HIV testing in the labor ward. Of these, 1,003 (82%) women presented with either no reports or incomplete reports of prior HIV testing results at the time of admission to the labor ward. Of 1,222 women, 15 were diagnosed as HIV-positive (on the basis of two rapid tests, dual ELISA and Western blot), yielding a seroprevalence of 1.23% (95% confidence interval [CI] 0.61%–1.8%). Of the 15 HIV test–positive women, four (27%) had presented with reported HIV status, and 11 (73%) new cases of HIV infection were detected due to rapid testing in the labor room. Thus, 11 HIV-positive women received PMTCT interventions on account of round-the-clock rapid HIV testing and counseling in the labor room. While both OraQuick tests (oral and finger-stick) were 100% specific, one false-negative result was documented (with both oral fluid and finger-stick specimens). Of the 15 HIV-infected women who delivered, 13 infants were HIV seronegative at birth and at 1 and 4 mo after delivery; two HIV-positive infants died within a month of delivery. Conclusions In a busy rural labor ward setting in India, we demonstrated that it is feasible to introduce a program of round-the-clock rapid HIV testing, including prepartum and extended postpartum counseling sessions. Our data suggest that the availability of round-the-clock rapid HIV testing resulted in successful documentation of HIV serostatus in a large proportion (82%) of rural women who were unaware of their HIV status when admitted to the labor room. In addition, 11 (73%) of a total of 15 HIV-positive women received PMTCT interventions because of round-the-clock rapid testing in the labor ward. These findings are relevant for PMTCT programs in developing countries.
PLOS ONE | 2007
Nitika Pant Pai; Rajnish Joshi; Sandeep Dogra; Bharati Taksande; Shriprakash Kalantri; Madhukar Pai; Pratibha Narang; Jacqueline P. Tulsky; Arthur Reingold
Background Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick® ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based OraQuick® Rapid HIV1/2 test in a rural hospital in India. Methodology/Principal Findings A cross-sectional, hospital-based study was conducted in 450 consenting participants with suspected HIV infection in rural India. The objectives were to evaluate performance, client preference and feasibility of the OraQuick® Rapid HIV-1/2 tests. Two Oraquick® Rapid HIV1/2 tests (oral fluid and finger stick) were administered in parallel with confirmatory ELISA/Western Blot (reference standard). Pre- and post-test counseling and face to face interviews were conducted to determine client preference. Of the 450 participants, 146 were deemed to be HIV sero-positive using the reference standard (seropositivity rate of 32% (95% confidence interval [CI] 28%, 37%)). The OraQuick test on oral fluid specimens had better performance with a sensitivity of 100% (95% CI 98, 100) and a specificity of 100% (95% CI 99, 100), as compared to the OraQuick test on finger stick specimens with a sensitivity of 100% (95% CI 98, 100), and a specificity of 99.7% (95% CI 98.4, 99.9). The OraQuick oral fluid-based test was preferred by 87% of the participants for first time testing and 60% of the participants for repeat testing. Conclusion/Significance In a rural Indian hospital setting, the OraQuick® Rapid- HIV1/2 test was found to be highly accurate. The oral fluid-based test performed marginally better than the finger stick test. The oral OraQuick test was highly preferred by participants. In the context of global efforts to scale-up HIV testing, our data suggest that oral fluid-based rapid HIV testing may work well in rural, resource-limited settings.