Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Norbert Licht is active.

Publication


Featured researches published by Norbert Licht.


International Journal of Radiation Oncology Biology Physics | 1999

18F-Deoxyglucose positron emission tomography (FDG-PET) for the planning of radiotherapy in lung cancer: high impact in patients with atelectasis

Ursula Nestle; Karin Walter; Sylvia Schmidt; Norbert Licht; Carsten Nieder; Babak Motaref; Dirk Hellwig; Marcus Niewald; Dieter Ukena; Carl M. Kirsch; Gerhard W. Sybrecht; Klaus Schnabel

PURPOSE 18F-deoxyglucose positron emission tomography (FDG-PET) is increasingly applied in the staging of lung cancer (LC). This study analyzes the potential contribution of PET in radiotherapy planning for LC with special respect to tumor-associated atelectasis. METHODS AND MATERIALS Thirty-four patients with histologically confirmed LC, who had been examined by PET during pretreatment staging, were included. All were irradiated after CT-based therapy planning with anterior/posterior (AP) portals encompassing the primary tumor and the mediastinum (CT portals, CP). The result of the PET examination was unknown in treatment planning. In retrospect, a PET portal (PP) was delineated and compared with the CP. RESULTS In 12/34 cases, the shape and/or size of the portals were changed, primarily (n = 10) the size of the fields was reduced. The median area of CP was 182 cm2 versus 167 cm2 of PP. Seventeen of 34 patients had dys- or atelectasis caused by a central primary tumor. In these cases, differences between CP and PP were significantly more frequent than in the other patients (8/17 vs. 3/17, p = 0.03). CONCLUSION In this retrospective analysis, the information provided by FDG-PET would have contributed to a substantial reduction of the size of radiotherapy portals. This applies particularly for patients with tumor-associated dys- or atelectasis.


Molecular Imaging and Biology | 2002

2-Deoxy-2-[18F]fluoro-D-glucose positron emission tomography in target volume definition for radiotherapy of patients with non-small-cell lung cancer.

Ursula Nestle; Dirk Hellwig; Sylvia Schmidt; Norbert Licht; Karin Walter; Dieter Ukena; Christian Rübe; Michael H. Baumann; Carl-Martin Kirsch

PURPOSE To discuss the potential contribution of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography (FDG-PET) in radiotherapy planning for non-small-cell lung cancer (NSCLC) considering new concepts on target volume definition. PROCEDURES Recent investigations on the topic are reviewed with regard to current concepts of target volume definition for NSCLC. RESULTS As intrathoracic recurrence is the leading cause of death after primary radiotherapy of NSCLC, there is a need for improving local control by escalating treatment intensity to gross disease. The value of elective nodal irradiation (ENI), resembling prophylactic irradiation of macroscopically unaffected parts of the mediastinum, is being considered. CONCLUSION As FDG-PET has been shown to enhance the diagnostic accuracy of computed tomography (CT), and to have a potentially high impact on the identification of malignant tissue, it should be implicated in prospective clinical trials on dose escalation and three-dimensional conformal radiotherapy, especially in those including a reduction of target volumes.


Medical Physics | 2012

Beam properties and stability of a flattening-filter free 7 MV beam-an overview.

Yvonne Dzierma; Norbert Licht; Frank Nuesken; Christian Ruebe

PURPOSE Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). METHODS Dosimetric properties of the 7XU beam were measured in May and September 2011. We present depth dose curves and beam profiles, output factors, and MLC transmission and assess the stability of the measurements. The 7XU beam was commissioned in the Pinnacle[superscript three] treatment planning system (TPS), and modeling results including the spectrum are presented. RESULTS The percent depth dose curve of the 7XU beam is similar to the flat 6X beam line, with a slightly smaller surface dose. The beam profiles show the characteristic shape of flattening-filter free beams, with deviations between measurements of generally less than 1%. The output factors of the 7XU beam decrease more slowly than for the 6X beam. The MLC transmission is comparable but slightly less for the 7XU beam. The 7XU beam can be adequately modeled by the Pinnacle[superscript three] TPS, with successful dosimetric verification. The spectrum of the 7XU beam has lower photon fluence up to approximately 2.5 MeV and higher fluence beyond, with a slightly higher mean energy. CONCLUSIONS The 7XU beam has been commissioned for clinical use after successful modeling, stability checks, and dosimetric verification.


Radiation Oncology | 2011

Toxicity after radiochemotherapy for glioblastoma using temozolomide - a retrospective evaluation

Marcus Niewald; Christian Berdel; Jochen Fleckenstein; Norbert Licht; Ralf Ketter; Christian Rübe

PurposeRetrospective evaluation of toxicity and results after radiochemotherapy for glioblastoma.Methods46 patients with histopathologically proven glioblastoma received simultaneous radiochemotherapy (RCT). The mean age at the beginning of therapy was 59 years, the mean Karnofsky performance index 80%. 44 patients had been operated on before radiotherapy, two had not. A total dose of 60 Gy was applied in daily single fractions of 2.0 Gy within six weeks, 75 mg/m2/day Temozolomide were given orally during the whole radiotherapy period.ResultsA local progression could be diagnosed in 34/46 patients (70%). The median survival time amounted to 13.6 months resulting in one-year and two-year survival probabilities of 48% and 8%, respectively.Radiotherapy could be applied completely in 89% of the patients. Chemotherapy could be completed according to schedule only in 56.5%, the main reason being blood toxicity (50% of the interruptions). Most of those patients suffered from leucopenia and/or thrombopenia grade III and IV CTC (Common toxicity criteria). Further reasons were an unfavourable general health status or a rise of liver enzymes.The mean duration of thrombopenia and leucopenia amounted to 64 and 20 days. In two patients, blood cell counts remained abnormal until death. In two patients we noticed a rise of liver enzymes. In one of these in the healing phase of hepatitis a rise of ASAT and ALAT CTC grade IV was diagnosed. These values normalized after termination of temozolomide medication. One patient died of pneumonia during therapy.ConclusionOur survival data were well within the range taken from the literature. However, we noticed a considerable frequency and intensity of side effects to bone marrow and liver. These lead to the recommendations that regular examinations of blood cell count and liver enzymes should be performed during therapy and temozolomide should not be applied or application should be terminated according to the criteria given by the manufacturer.


Radiation Oncology | 2009

Intraoperative radiotherapy (IORT) combined with external beam radiotherapy (EBRT) for soft-tissue sarcomas – a retrospective evaluation of the Homburg experience in the years 1995–2007

Marcus Niewald; Jochen Fleckenstein; Norbert Licht; Caroline Bleuzen; Christian Ruebe

PurposeTo retrospectively evaluate the results after a regimen of surgery, IORT (intraoperative radiotherapy), and EBRT (external beam radiotherapy) for soft-tissue sarcomasMethods38 consecutive patients underwent IORT for soft-tissue sarcoma; 29 were treated for primary tumours, 9 for recurrences. There were 14 cases with liposarcomas, 8 with leiomyosarcomas, 7 with malignant fibrous histiocytomas. 27/38 tumours were located in the extremities, the remaining ones in the retroperitoneum or the chest. Radical resection was attempted in all patients; a R0-resection was achieved in 15/38 patients, R1 in 12/38 pats and R2 in 4/38 pats. IORT was performed using a J-125 source and a HDR (high dose rate) afterloading machine after suturing silicone flaps to the tumour bed. The total dose applied ranged from 8–15 Gy/0.5 cm tissue depth measured from the flap surface. After wound healing external beam radiotherapy (EBRT) was applied in 31/38 patients with total doses of 23–56 Gy dependent on resection status and wound situation. The mean duration of follow-up was 2.3 years.ResultsA local recurrence was found in 10/36 patients, lymph node metastases in 2/35, and distant metastases in 6/35 patients. The actuarial local control rate was 63%/5 years. The overall survival rate was 57%/5 years. There was no statistically significant difference between the results after treatment for primaries or for recurrences. Late toxicity to the skin was found in 13/31 patients, wound healing problems in 5/31 patients. A neuropathy was never seen.ConclusionThe combination of surgery, IORT, and EBRT yields favourable local control and survival data which are well within the range of the results reported in the literature. The complication rates, however, are considerable although the complications are not severe, they should be taken into account when therapy decisions are made.


Physica Medica | 2015

Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer.

Yvonne Dzierma; Monica Beyhs; Jan Palm; Marcus Niewald; Katharina Bell; Frank Nuesken; Norbert Licht; Christian Rübe

PURPOSE The purpose of this work is to compare the positioning accuracy achieved by three different imaging techniques and planar vs. CBCT imaging for two common IGRT indications. METHODS A collective of prostate cancer and head-and-neck cancer patients treated at our institution during the year 2013 was retrospectively analyzed. For all treatment fractions (3078 in total), the kind of acquired set-up image and the performed couch shift before treatment were assessed. The distribution of couch corrections was compared for three different imaging systems available at our institution: the treatment beam line operating at 6 MV, a dedicated imaging beam line of nominally 1 MV, and the kVision system at 70-121 kV. Shifts were analyzed for planar and cone-beam CT images. Based on the set-up corrections, CTV to PTV expansion margins were calculated. RESULTS The difference in set-up corrections performed for the three energies and both techniques (planar vs. CBCT) was not significant for head-and-neck cancer patients. For prostate cancer all shifts had equal variance. Averages ranged from -0.7 to +0.7 mm. The set-up margins calculated on the basis of the observed shifts are 4.0 mm (AP) and 3.8 mm (SI, LR) for the head-and-neck PTV and 6.6 mm (SI), 6.7 mm (AP) and 7.9 mm (LR) for the prostate cancer patients. CONCLUSIONS For three different linac-based imaging energies and planar/CBCT imaging, no relevant differences in set-up shifts were observed. The suggested set-up margins for these indications are of the order of 4 mm for head-and-neck and 6-8 mm for prostate treatment.


International Journal of Radiation Oncology Biology Physics | 2014

Dosimetry of an in-line kilovoltage imaging system and implementation in treatment planning.

Yvonne Dzierma; Frank Nuesken; Wladimir Otto; Parham Alaei; Norbert Licht; Christian Rübe

PURPOSE To present the beam properties of the Siemens 70-kV and 121-kV linear accelerator-mounted imaging modalities and commissioning of the 121-kV beam in the Philips Pinnacle treatment planning system (TPS); measurements in an Alderson phantom were performed for verification of the model and to estimate the cone-beam CT (CBCT) imaging dose in the head and neck, thorax, and pelvis. METHODS AND MATERIALS The beam profiles and depth-dose curve were measured in an acrylic phantom using thermoluminescent dosimeters and a soft x-ray ionization chamber. Measurements were imported into the TPS, modeled, and verified by phantom measurements. RESULTS Modeling of the profiles and the depth-dose curve can be achieved with good quality. Comparison with the measurements in the Alderson phantom is generally good; only very close to bony structures is the dose underestimated by the TPS. For a 200° arc CBCT of the head and neck, a maximum dose of 7 mGy is measured; the thorax and pelvis 360° CBCTs give doses of 4-10 mGy and 7-15 mGy, respectively. CONCLUSIONS Dosimetric characteristics of the Siemens kVision imaging modalities are presented and modeled in the Pinnacle TPS. Thermoluminescent dosimeter measurements in the Alderson phantom agree well with the calculated TPS dose, validating the model and providing an estimate of the imaging dose for different protocols.


Physica Medica | 2016

mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams

Katharina Bell; Yvonne Dzierma; Jan Palm; Frank Nuesken; Norbert Licht; Christian Rübe

PURPOSE The modulated arc (mARC) technique as an alternative to VMAT is a rotational IMRT irradiation with burst mode delivery. Varian has recently implemented an option for mARC-planning into the Eclipse treatment planning system (TPS) and so far mARC-planning with this TPS has not been evaluated systematically. Therefore, for prostate treatment with Eclipse we compare mARC with IMRT using flat (6MV) and flattening-filter-free (FFF, 7MV) beam energies. METHODS For ten prostate cancer patients standardized re-contouring and re-planning was performed with a prescription of 76Gy to the complete planning-target-volume (PTV). IMRT and mARC plans (6MV vs. FFF 7MV) were compared pairwise considering indices for plan quality. All plans were delivered on an anthromorphic phantom equipped with thermoluminescent dosimeters to measure out-of-field dose and treatment times. RESULTS Regarding PTV coverage, there was no marked preference for either technique or energy. The evaluation of organs at risk showed improved bladder sparing of the mARC plans up to about 75Gy; above this dose the IMRT plans achieved significant better sparing. The use of the FFF-beam-energy and mARC-technique resulted in a significant decrease in out-of-field dose. This combination also led to a drastic reduction of treatment time by factor of three in comparison with 6MV IMRT. CONCLUSION While highly conformal treatment plans could be created by the use of all modalities, the combination of the high dose rate with mARC appears to be the preferable option as it benefits from a marked decrease in treatment time and out-of-field dose.


Practical radiation oncology | 2014

Planning study and dose measurements of intracranial stereotactic radiation surgery with a flattening filter-free linac

Yvonne Dzierma; Frank Nuesken; Jan Palm; Norbert Licht; Christian Ruebe

PURPOSE Flattening filter-free (FFF) beams have recently become available for radiation therapy, offering much higher dose rates but complicating treatment owing to the nonflat profile. Stereotactic treatment is one of the most evident scenarios to investigate the use of FFF beams. METHODS AND MATERIALS We present a planning study of a FFF 7-MV beam for the treatment of brain metastases using multiple noncoplanar arcs. Plan differences as compared with flat 6 MV photon fields are estimated using different measures of quality. Absolute dosimetry and fluence distribution are verified and the out-of-field dose is measured. RESULTS The FFF 7-MV plans are slightly better than the flat 6-MV plans as evaluated by a number of quality indices, dose to organs at risk, and out-of-field dose, although differences may not be clinically relevant. Verification does not pose any problems. CONCLUSIONS The FFF 7-MV treatment plans are marginally superior to the flat-beam 6-MV plans in almost all cases, with greatly reduced treatment times (almost 50%).


PLOS ONE | 2013

Visualisation of Respiratory Tumour Motion and Co-Moving Isodose Lines in the Context of Respiratory Gating, IMRT and Flattening-Filter-Free Beams

Yvonne Dzierma; Frank Nuesken; Jochen Fleckenstein; Stephanie Kremp; Norbert Licht; Christian Ruebe

Respiratory motion during percutaneous radiotherapy can be considered based on respiration-correlated computed tomography (4DCT). However, most treatment planning systems perform the dose calculation based on a single primary CT data set, even though cine mode displays may allow for a visualisation of the complete breathing cycle. This might create the mistaken impression that the dose distribution were independent of tumour motion. We present a movie visualisation technique with the aim to direct attention to the fact that the dose distribution migrates to some degree with the tumour and discuss consequences for gated treatment, IMRT plans and flattening-filter-free beams. This is a feasibility test for a visualisation of tumour and isodose motion. Ten respiratory phases are distinguished on the CT, and the dose distribution from a stationary IMRT plan is calculated on each phase, to be integrated into a movie of tumour and dose motion during breathing. For one example patient out of the sample of five lesions, the plan is compared with a gated treatment plan with respect to tumour coverage and lung sparing. The interplay-effect for small segments in the IMRT plan is estimated. While the high dose rate, together with the cone-shaped beam profile, makes the use of flattening-filter-free beams more problematic for conformal and IMRT treatment, it can be the option of choice if gated treatment is preferred. The different effects of respiratory motion, dose build-up and beam properties (segments and flatness) for gated vs. un-gated treatment can best be considered if planning is performed on the full 4DCT data set, which may be an incentive for future developments of treatment planning systems.

Collaboration


Dive into the Norbert Licht's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge