Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where O Zeidan is active.

Publication


Featured researches published by O Zeidan.


Medical Physics | 2006

Characterization and use of EBT radiochromic film for IMRT dose verification

O Zeidan; Stacy Ann L. Stephenson; Sanford L. Meeks; Thomas H. Wagner; Twyla R. Willoughby; Patrick A. Kupelian; Katja M. Langen

We present an evaluation of a new and improved radiochromic film, type EBT, for its implementation to IMRT dose verification. Using a characterized flat bed color CCD scanner, the films dose sensitivity, uniformity, and speed of development post exposure were shown to be superior to previous types of radiochromic films. The films dose response was found to be very similar to ion chamber scans in water through comparisons of depth dose and lateral dose profiles. The effect of EBT film polarization with delivered dose and film scan orientation was shown to have a significant effect on the scanners OD readout. In addition, the films large size, flexibility, and the ability to submerge it in water for relatively short periods of time allowed for its use in both water and solid water phantoms to verify TomoTherapy IMRT dose distributions in flat and curved dose planes. Dose verification in 2D was performed on ten IMRT plans (five head and neck and five prostate) by comparing measured EBT dose distributions to TomoTherapy treatment planning system calculated dose. The quality of agreement was quantified by the gamma index for four sets of dose difference and distance to agreement criteria. Based on this study, we show that EBT film has several favorable features that allow for its use in routine IMRT patient-specific QA.


Medical Physics | 2010

Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

O Zeidan; S. I. Sriprisan; O. Lopatiuk-Tirpak; Patrick A. Kupelian; Sanford L. Meeks; W Hsi; Jatinder R. Palta; M Maryanski

PURPOSE The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. METHODS Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. RESULTS The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (> 97%) of the gel dose maps pass the 3%/3 mm gamma criterion. CONCLUSIONS This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.


Medical Physics | 2008

Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries

O. Lopatiuk-Tirpak; Katja M. Langen; Sanford L. Meeks; Patrick A. Kupelian; O Zeidan; M Maryanski

The performance of a next-generation optical computed tomography scanner (OCTOPUS-5X) is characterized in the context of three-dimensional gel dosimetry. Large-volume (2.2 L), muscle-equivalent, radiation-sensitive polymer gel dosimeters (BANG-3) were used. Improvements in scanner design leading to shorter acquisition times are discussed. The spatial resolution, detectable absorbance range, and reproducibility are assessed. An efficient method for calibrating gel dosimeters using the depth-dose relationship is applied, with photon- and electron-based deliveries yielding equivalent results. A procedure involving a preirradiation scan was used to reduce the edge artifacts in reconstructed images, thereby increasing the useful cross-sectional area of the dosimeter by nearly a factor of 2. Dose distributions derived from optical density measurements using the calibration coefficient show good agreement with the treatment planning system simulations and radiographic film measurements. The feasibility of use for motion (four-dimensional) dosimetry is demonstrated on an example comparing dose distributions from static and dynamic delivery of a single-field photon plan. The capability to visualize three-dimensional dose distributions is also illustrated.


Medical Physics | 2011

Commissioning of output factors for uniform scanning proton beams

Y Zheng; E Ramirez; A Mascia; Xiaoning Ding; Benny Okoth; O Zeidan; Wen Hsi; B Harris; A Schreuder; Sameer R. Keole

PURPOSE Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. METHODS Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. RESULTS The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. CONCLUSIONS Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output measurements for proton treatments.


Medical Physics | 2005

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

Katja M. Langen; Sanford L. Meeks; D. Poole; Thomas H. Wagner; Twyla R. Willoughby; O Zeidan; Patrick A. Kupelian; Kenneth J. Ruchala; Gustavo H. Olivera

A helical tomotherapy system is used in our clinic to deliver intensity-modulated radiation therapy (IMRT) treatments. Since this machine is designed to deliver IMRT treatments, the traditional field flatness requirements are no longer applicable. This allows the unit to operate without a field flatness filter and consequently the 400 mm wide fan beam is highly inhomogeneous in intensity. The shape of this beam profile is mapped during machine commissioning and for quality assurance purposes the shape of the beam profile needs to be monitored. The use of a commercial diode array for quality assurance measurements is investigated. Central axis beam profiles were acquired at different depths using solid water built-up material. These profiles were compared with ion chamber scans taken in a water tank to test the accuracy of the diode array measurements. The sensitivity of the diode array to variations in the beam profile was checked. Over a seven week period, beam profiles were repeatedly measured. The observed variations are compared with those observed with an on-board beam profile monitor. The diode measurements were in agreement with the ion chamber scans. In the high dose, low gradient region the average ratio between the diode and ion chamber readings was 1.000 +/- 0.005 (+/- 1 standard deviation). In the penumbra region the agreement was poorer but all diodes passed the distance to agreement (DTA) requirement of 2 mm. The trend in the beam profile variations that was measured with the diode array device was in agreement with the on-board monitor. While the calculated amount of variation differs between the devices, both were sensitive to subtle variations in the beam profile. The diode array is a valuable tool to quickly and accurately monitor the beam profile on a helical tomotherapy unit.


Medical Physics | 2012

Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams

Y Zheng; Yaxi Liu; O Zeidan; A Schreuder; Sameer R. Keole

PURPOSE Neutron exposure is of concern in proton therapy, and varies with beam delivery technique, nozzle design, and treatment conditions. Uniform scanning is an emerging treatment technique in proton therapy, but neutron exposure for this technique has not been fully studied. The purpose of this study is to investigate the neutron dose equivalent per therapeutic dose, H/D, under various treatment conditions for uniform scanning beams employed at our proton therapy center. METHODS Using a wide energy neutron dose equivalent detector (SWENDI-II, ThermoScientific, MA), the authors measured H/D at 50 cm lateral to the isocenter as a function of proton range, modulation width, beam scanning area, collimated field size, and snout position. They also studied the influence of other factors on neutron dose equivalent, such as aperture material, the presence of a compensator, and measurement locations. They measured H/D for various treatment sites using patient-specific treatment parameters. Finally, they compared H/D values for various beam delivery techniques at various facilities under similar conditions. RESULTS H/D increased rapidly with proton range and modulation width, varying from about 0.2 mSv/Gy for a 5 cm range and 2 cm modulation width beam to 2.7 mSv/Gy for a 30 cm range and 30 cm modulation width beam when 18 × 18 cm(2) uniform scanning beams were used. H/D increased linearly with the beam scanning area, and decreased slowly with aperture size and snout retraction. The presence of a compensator reduced the H/D slightly compared with that without a compensator present. Aperture material and compensator material also have an influence on neutron dose equivalent, but the influence is relatively small. H/D varied from about 0.5 mSv/Gy for a brain tumor treatment to about 3.5 mSv/Gy for a pelvic case. CONCLUSIONS This study presents H/D as a function of various treatment parameters for uniform scanning proton beams. For similar treatment conditions, the H/D value per uncollimated beam size for uniform scanning beams was slightly lower than that from a passive scattering beam and higher than that from a pencil beam scanning beam, within a factor of 2. Minimizing beam scanning area could effectively reduce neutron dose equivalent for uniform scanning beams, down to the level close to pencil beam scanning.


Medical Physics | 2013

Measurements of lateral penumbra for uniform scanning proton beams under various beam delivery conditions and comparison to the XiO treatment planning system

Suresh Rana; O Zeidan; E Ramirez; Michael Rains; Junfang Gao; Y Zheng

PURPOSE The main purposes of this study were to (1) investigate the dependency of lateral penumbra (80%-20% distance) of uniform scanning proton beams on various factors such as air gap, proton range, modulation width, compensator thickness, and depth, and (2) compare the lateral penumbra calculated by a treatment planning system (TPS) with measurements. METHODS First, lateral penumbra was measured using solid-water phantom and radiographic films for (a) air gap, ranged from 0 to 35 cm, (b) proton range, ranged from 8 to 30 cm, (c) modulation, ranged from 2 to 10 cm, (d) compensator thickness, ranged from 0 to 20 cm, and (e) depth, ranged from 7 to 15 cm. Second, dose calculations were computed in a virtual water phantom using the XiO TPS with pencil beam algorithm for identical beam conditions and geometrical configurations that were used for the measurements. The calculated lateral penumbra was then compared with the measured one for both the horizontal and vertical scanning magnets of our uniform scanning proton beam delivery system. RESULTS The results in the current study showed that the lateral penumbra of horizontal scanning magnet was larger (up to 1.4 mm for measurement and up to 1.0 mm for TPS) compared to that of vertical scanning magnet. Both the TPS and measurements showed an almost linear increase in lateral penumbra with increasing air gap as it produced the greatest effect on lateral penumbra. Lateral penumbra was dependent on the depth and proton range. Specifically, the width of lateral penumbra was found to be always lower at shallower depth than at deeper depth within the spread out Bragg peak (SOBP) region. The lateral penumbra results were less sensitive to the variation in the thickness of compensator, whereas lateral penumbra was independent of modulation. Overall, the comparison between the results of TPS with that of measurements indicates a good agreement for lateral penumbra, with TPS predicting higher values compared to measurements. CONCLUSIONS Lateral penumbra of uniform scanning proton beams depends on air gap, proton range, compensator thickness, and depth, whereas lateral penumbra is not dependent on modulation. The XiO TPS typically overpredicted lateral penumbra compared to measurements, within 1 mm for most cases, but the difference could be up to 2.5 mm at a deep depth and large air gap.


Journal of Applied Clinical Medical Physics | 2011

Image-guided bolus electron conformal therapy – a case study

O Zeidan; Bhavin Chauhan; William W. Estabrook; Twyla R. Willoughby; Rafael R. Mañon; Sanford L. Meeks

We report on our initial experience with daily image guidance for the treatment of a patient with a basal cell carcinoma of the nasal dorsum using bolus electron conformal therapy. We describe our approach to daily alignment using treatment machine‐integrated megavoltage (MV) planar imaging in conjunction with cone beam CT (CBCT) volumetric imaging to ensure the best possible setup reproducibility. Based on MV imaging, beam aperture misalignment with the intended treatment region was as large as 0.5 cm in the coronal plane. Four of the five fractions analyzed show induced shifts when compared to digitally reconstructed radiographs (DRR), in the range of 0.2−0.5 cm. Daily inspection of CBCT images show that the bolus device can have significant tilt in any given direction by as much as 13° with respect to beam axis. In addition, we show that CBCT images reveal air gaps between bolus and skin that vary from day to day, and can potentially degrade surface dose coverage. Retrospective dose calculation on CBCT image sets shows that when daily shifts based on MV imaging are not corrected, geometrical miss of the planning target volume (PTV) can cause an underdosing as large as 14% based on DVH analysis of the dose to the 90% of the PTV volume. PACS number: 87.55.kh


International Journal of Radiation Oncology Biology Physics | 2010

A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

O Zeidan; Adam J. Huddleston; Choonik Lee; Katja M. Langen; Patrick A. Kupelian; Sanford L. Meeks; Rafael R. Mañon

PURPOSE To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. METHODS AND MATERIALS A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. RESULTS Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +/-5%) compared with the kilovoltage CT plan. CONCLUSION The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.


computer assisted radiology and surgery | 2008

Online external beam radiation treatment simulator

Felix G. Hamza-Lup; Ivan Sopin; O Zeidan

Radiation therapy is an effective and widely accepted form of treatment for many types of cancer that requires extensive computerized planning. Unfortunately, current treatment planning systems have limited or no visual aid that combines patient volumetric models extracted from patient-specific CT data with the treatment device geometry in a 3D interactive simulation. We illustrate the potential of 3D simulation in radiation therapy with a web-based interactive system that combines novel standards and technologies. We discuss related research efforts in this area and present in detail several components of the simulator. An objective assessment of the accuracy of the simulator and a usability study prove the potential of such a system for simulation and training.

Collaboration


Dive into the O Zeidan's collaboration.

Top Co-Authors

Avatar

Sanford L. Meeks

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Katja M. Langen

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Twyla R. Willoughby

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Thomas H. Wagner

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Rafael R. Mañon

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

O. Lopatiuk-Tirpak

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Wen Hsi

University of Florida

View shared research outputs
Top Co-Authors

Avatar

A Mascia

University of Florida

View shared research outputs
Top Co-Authors

Avatar

E Ramirez

Southern Nazarene University

View shared research outputs
Researchain Logo
Decentralizing Knowledge