Featured researches published by Olivia W Brooks.


Journal of NeuroInterventional Surgery | 2016

Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT): a comparative evaluation of VasoCT and intravascular OCT

Kajo van der Marel; Matthew J. Gounis; John P. Weaver; Antonius M de Korte; R King; Jennifer M Arends; Olivia W Brooks; Ajay K. Wakhloo; Ajit S. Puri

Background Poor vessel wall apposition of flow diverter (FD) stents poses risks for stroke-related complications when treating intracranial aneurysms, necessitating long-term surveillance imaging. To facilitate quantitative evaluation of deployed devices, a novel algorithm is presented that generates intuitive two-dimensional representations of wall apposition from either high-resolution contrast-enhanced cone-beam CT (VasoCT) or intravascular optical coherence tomography (OCT) images. Methods VasoCT and OCT images were obtained after FD implant (n=8 aneurysms) in an experimental sidewall aneurysm model in canines. Surface models of the vessel wall and FD device were extracted, and the distance between them was presented on a two-dimensional flattened map. Maps and cross-sections at potential locations of malapposition detected on VasoCT-based maps were compared. The performance of OCT-based apposition detection was evaluated on manually labeled cross-sections using logistic regression against a thresholded (≥0.25 mm) apposition measure. Results VasoCT and OCT acquisitions yielded similar Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT) apposition maps. GRAFT maps from VasoCT highlighted 16 potential locations of malapposition, of which two were found to represent malapposed device struts. Logistic regression showed that OCT could detect malapposition with a sensitivity of 98% and a specificity of 81%. Conclusions GRAFT delivered quantitative and visually convenient representations of potential FD malapposition and occasional acute thrombus formation. A powerful combination for future neuroendovascular applications is foreseen with the superior resolution delivered by intravascular OCT.


Stroke | 2015

Shear-Activated Nanoparticle Aggregates Combined With Temporary Endovascular Bypass to Treat Large Vessel Occlusion

M Marosfoi; Netanel Korin; Matthew J. Gounis; Oktay Uzun; Srinivasan Vedantham; E Langan; Anne-Laure Papa; Olivia W Brooks; Christopher M. Johnson; Ajit S. Puri; Deen Bhatta; Mathumai Kanapathipillai; Ben R. Bronstein; Ju-Yu Chueh; Donald E. Ingber; Ajay K. Wakhloo

Background and Purpose— The goal of this study is to combine temporary endovascular bypass (TEB) with a novel shear-activated nanotherapeutic (SA-NT) that releases recombinant tissue-type plasminogen activator (r-tPA) when exposed to high levels of hemodynamic stress and to determine if this approach can be used to concentrate r-tPA at occlusion sites based on high shear stresses created by stent placement. Methods— A rabbit model of carotid vessel occlusion was used to test the hypothesis that SA-NT treatment coupled with TEB provides high recanalization rates while reducing vascular injury. We evaluated angiographic recanalization with TEB alone, intra-arterial delivery of soluble r-tPA alone, or TEB combined with 2 doses of intra-arterial infusion of either the SA-NT or soluble r-tPA. Vascular injury was compared against stent-retriever thrombectomy. Results— Shear-targeted delivery of r-tPA using the SA-NT resulted in the highest rate of complete recanalization when compared with controls (P=0.0011). SA-NT (20 mg) had a higher likelihood of obtaining complete recanalization as compared with TEB alone (odds ratio 65.019, 95% confidence interval 1.77, >1000; P=0.0231), intra-arterial r-tPA alone (odds ratio 65.019, 95% confidence interval 1.77, >1000; P=0.0231), or TEB with soluble r-tPA (2 mg; odds ratio 18.78, 95% confidence interval 1.28, 275.05; P=0.0322). Histological analysis showed circumferential loss of endothelium restricted to the area where the TEB was deployed; however, there was significantly less vascular injury using a TEB as compared with stent-retriever procedure (odds ratio 12.97, 95% confidence interval 8.01, 21.02; P<0.0001). Conclusions— A novel intra-arterial, nanoparticle-based thrombolytic therapy combined with TEB achieves high rates of complete recanalization. Moreover, this approach reduces vascular trauma as compared with stent-retriever thrombectomy.


Journal of NeuroInterventional Surgery | 2016

Quantitative assessment of device–clot interaction for stent retriever thrombectomy

Kajo van der Marel; Ju-Yu Chueh; Olivia W Brooks; R King; M Marosfoi; E Langan; Sarena L Carniato; Matthew J. Gounis; Raul G. Nogueira; Ajit S. Puri

Purpose Rapid revascularization in emergent large vessel occlusion with endovascular embolectomy has proven clinical benefit. We sought to measure device–clot interaction as a potential mechanism for efficient embolectomy. Methods Two different radiopaque clot models were injected to create a middle cerebral artery occlusion in a patient-specific vascular phantom. A radiopaque stent retriever was deployed within the clot by unsheathing the device or a combination of unsheathing followed by pushing the device (n=8/group). High-resolution cone beam CT was performed immediately after device deployment and repeated after 5 min. An image processing pipeline was created to quantitatively evaluate the volume of clot that integrates with the stent, termed the clot integration factor (CIF). Results The CIF was significantly different for the two deployment variations when the device engaged the hard clot (p=0.041), but not the soft clot (p=0.764). In the hard clot, CIF increased significantly between post-deployment and final imaging datasets when using the pushing technique (p=0.019), but not when using the unsheathing technique (p=0.067). When we investigated the effect of time on CIF in the different clot models disregarding the technique, the CIF was significantly increased in the final dataset relative to the post-deployment dataset in both clot models (p=0.004–0.007). Conclusions This study demonstrates in an in vitro system the benefit of pushing the Trevo stent during device delivery in hard clot to enhance integration. Regardless of delivery technique, clot–device integration increased in both clot models by waiting 5 min.


Journal of NeuroInterventional Surgery | 2017

Acute thrombus formation on phosphorilcholine surface modified flow diverters

M Marosfoi; Frédéric Clarençon; E Langan; R King; Olivia W Brooks; Takamitsu Tamura; John Wainwright; Matthew J. Gounis; Srinivasan Vedantham; Ajit S. Puri

Purpose Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). Methods Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. Results Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). Conclusion In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.


Interventional Neurology | 2017

Novel Distal Emboli Protection Technology: The EmboTrap

Ju-Yu Chueh; M Marosfoi; Olivia W Brooks; R King; Ajit S. Puri; Matthew J. Gounis

Background: Over the course of the thrombectomy procedure, clot fragments may become dislodged and lead to downstream emboli due to manipulation of an endovascular device. The EmboTrap thrombectomy system features an inner stent channel with an outer stent trap design that may potentially reduce the risk of distal clot fragmentation during clot removal. We tested the hypothesis that distal emboli to both the same and new territory generated during mechanical thrombectomy are a function of device design. Methods: EmboTrap and Solitaire thrombectomy were conducted in an in vitro model system that mimicked a middle-cerebral artery (MCA) occlusion within a complete circle of Willis vascular replica and a contrast-enhanced clot analog. Emboli generated during the procedure with a size >1,000 μm were collected and measured with calipers. The Coulter principle was used to characterize emboli with a size between 200 and 1,000 µm. Results: EmboTrap thrombectomy resulted in a significant reduction in the risk of large emboli (>1,000 μm) formation as compared to first-generation stent retriever thrombectomy (p = 0.031, Fisher exact test). The majority of emboli >1,000 μm (∼80%) were found in the MCA, regardless of device type. There was no significant difference between the EmboTrap and Solitaire in 200 to 1,000 μm emboli formation (p = 0.89, Mann-Whitney test). When combining all emboli in the most dangerous range (>200 μm), EmboTrap offered a size reduction of emboli (p = 0.022). Conclusion: The risk of distal embolization can be altered with improved stent retriever design. When encountering fragment-prone clots, EmboTrap thrombectomy may lower the risk of distal embolization.


Journal of NeuroInterventional Surgery | 2018

Phosphorylcholine surface modified flow diverter associated with reduced intimal hyperplasia

Jildaz Caroff; Takamitsu Tamura; R King; Pedro Lylyk; E Langan; Olivia W Brooks; Frédéric Clarençon; John Wainwright; Laurent Spelle; M Marosfoi; Matthew J. Gounis; Ajit S. Puri

Background Optical coherence tomography (OCT) is a high-resolution, intra-vascular diagnostic technique widely used for the characterization of vascular pathologies and optimization of stent implantation during percutaneous coronary intervention. OCT was used to investigate the in vivo vascular response to a new phosphorylcholine surface modified flow diverter (sPED). Methods In an in vivo rabbit aneurysmal model, we used two different types of flow diverters (classic Pipeline – cPED; and sPED) with or without dual antiplatelet therapy (four groups, n=10 per group). OCT cross-sectional area measurements were compared with histology in all animals. Neointimal hyperplasia (NIH) ratio was compared between OCT and histology at five different levels for each stent. The severity of NIH was also compared between the different stents, antiplatelet protocols, and vessel locations. Results OCT was used to calculate in-stent hyperplasia in 227 different locations corresponding to histology sections. OCT measurement strongly correlated with gold standard histology (r2=0.83; slope=0.988; P<0.0001). sPED had significantly less in-stent NIH than non-treated flow diverters (mean percent of lumen reduction 5.7% for sPED versus 8.9% for cPED; P<0.0001). The NIH ratio was slightly higher with dual antiplatelet therapy (DAPT) (NIH ratio=7.9% with DAPT versus 6.8% without DAPT; P<0.05). Complete and near complete occlusion rates of the aneurysms were not different with the cPED or sPED. Conclusion OCT is a promising technique for immediate and long-term evaluation of flow diverter stent treatments. In an animal model, phosphorylcholine surface modified flow diverters induces less NIH after stent implant without reducing aneurysm occlusion rates.


Journal of NeuroInterventional Surgery | 2018

Communicating malapposition of flow diverters assessed with optical coherence tomography correlates with delayed aneurysm occlusion

R King; Olivia W Brooks; E Langan; Jildaz Caroff; Frédéric Clarençon; Takamitsu Tamura; John Wainwright; Matthew J. Gounis; Miklós Marosfői; Ajit S. Puri

Background Optical coherence tomography (OCT) is a high resolution intravascular imaging method that allows visualization of flow diverter struts and the vessel wall. In this study, malapposition of the flow diverter that continues into the neck of the aneurysm, named communicating malapposition (CM), was investigated as a potential factor for delayed aneurysm healing. Methods 40 New Zealand White rabbits underwent elastase induced aneurysm creation, and were subsequently assigned to one of four treatment groups based on flow diverter type and administration of antiplatelet therapy. All animals underwent post device deployment balloon angioplasty and subsequent OCT to assess device/vessel apposition. The incidence of CM seen on OCT was assessed with a binary scoring system: 0–CM present; 1–CM absent. At 30 days, DSA was acquired to assess aneurysm healing. Aneurysm healing on terminal DSA was measured using a previously developed 5 point scale, with a score of 3 or 4 considered a positive outcome. Results All animals were grouped into a single cohort for analysis as no difference in the rate of CM or healing was seen in the four treatment groups. Significant interaction between the absence of CM and a positive outcome was confirmed by Fisher exact test (P=0.0034). Angioplasty was shown to treat 33% of the cases of CM seen at implant, and these treated cases overwhelmingly had a positive outcome (P<0.001). Conclusion The use of OCT to assess CM of flow diverters has been shown to be predictive of the 30 day healing rate of an animal model of aneurysms.


Journal of NeuroInterventional Surgery | 2018

Development of a high resolution MRI intracranial atherosclerosis imaging phantom

Ju Yu Chueh; Kajo van der Marel; Matthew J. Gounis; Todd LeMatty; Truman R. Brown; Sameer A. Ansari; Timothy J. Carroll; Amanda K. W. Buck; Xiaohong Joe Zhou; A. Rano Chatterjee; R King; Hui Mao; Shaokuan Zheng; Olivia W Brooks; Jeff W. Rappleye; Richard H. Swartz; Edward Feldmann; Tanya N. Turan

Background and purpose Currently, there is neither a standard protocol for vessel wall MR imaging of intracranial atherosclerotic disease (ICAD) nor a gold standard phantom to compare MR sequences. In this study, a plaque phantom is developed and characterized that provides a platform for establishing a uniform imaging approach for ICAD. Materials and methods A patient specific injection mold was 3D printed to construct a geometrically accurate ICAD phantom. Polyvinyl alcohol hydrogel was infused into the core shell mold to form the stenotic artery. The ICAD phantom incorporated materials mimicking a stenotic vessel and plaque components, including fibrous cap and lipid core. Two phantoms were scanned using high resolution cone beam CT and compared with four different 3 T MRI systems across eight different sites over a period of 18 months. Inter-phantom variability was assessed by lumen dimensions and contrast to noise ratio (CNR). Results Quantitative evaluation of the minimum lumen radius in the stenosis showed that the radius was on average 0.80 mm (95% CI 0.77 to 0.82 mm) in model 1 and 0.77 mm (95% CI 0.74 to 0.81 mm) in model 2. The highest CNRs were observed for comparisons between lipid and vessel wall. To evaluate manufacturing reproducibility, the CNR variability between the two models had an average absolute difference of 4.31 (95% CI 3.82 to 5.78). Variation in CNR between the images from the same scanner separated by 7 months was 2.5–6.2, showing reproducible phantom durability. Conclusions A plaque phantom composed of a stenotic vessel wall and plaque components was successfully constructed for multicenter high resolution MRI standardization.


Neurosurgery | 2018

Robotic Assisted MRI-Guided Interventional Interstitial MR Guided Focused Ultrasound Ablation in a Swine Model

Jacquelyn MacDonell; Niravkumar A. Patel; Gregory S. Fischer; E. Clif Burdette; Jiang Qian; Vaibhav Chumbalkar; Goutam Ghoshal; Tamas Heffter; Emery Williams; Matthew J. Gounis; R King; Juliette Thibodeau; Gene Bogdanov; Olivia W Brooks; E Langan; Roy Hwang; Julie G. Pilitsis

BACKGROUND Ablative lesions are current treatments for epilepsy and brain tumors. Interstitial magnetic resonance (MR) guided focused ultrasound (iMRgFUS) may be an alternate ablation technique which limits thermal tissue charring as compared to laser therapy (LITT) and can produce larger ablation patterns nearer the surface than transcranial MR guided focused ultrasound (tcMRgFUS). OBJECTIVE To describe our experience with interstitial focused ultrasound (iFUS) ablations in swine, using MR-guided robotically assisted (MRgRA) delivery. METHODS In an initial 3 animals, we optimized the workflow of the robot in the MR suite and made modifications to the robotic arm to allow range of motion. Then, 6 farm pigs (4 acute, 2 survival) underwent 7 iMRgFUS ablations using MRgRA. We altered dosing to explore differences between thermal dosing in brain as compared to other tissues. Imaging was compared to gross examination. RESULTS Our work culminated in adjustments to the MRgRA, iMRgFUS probes, and dosing, culminating in 2 survival surgeries; swine had ablations with no neurological sequelae at 2 wk postprocedure. Immediately following iMRgFUS therapy, diffusion-weighted imaging, and T1 weighted MR were accurate reflections of the ablation volume. T2 and fluid-attenuated inversion-recovery (FLAIR) images were accurate reflections of ablation volume 1-wk postprocedure. CONCLUSION We successfully performed MRgRA iFUS ablation in swine and found intraoperative and postoperative imaging to correlate with histological examination. These data are useful to validate our system and to guide imaging follow-up for thermal ablation lesions in brain tissue from our therapy, tcMRgFUS, and LITT.


NeuroImage | 2018

A stereotaxic breed-averaged, symmetric T2w canine brain atlas including detailed morphological and volumetrical data sets

Björn Nitzsche; Johannes Boltze; Eberhard Ludewig; Thomas Flegel; Martin J. Schmidt; Johannes Seeger; Henryk Barthel; Olivia W Brooks; Matthew J. Gounis; Michael Hubert Stoffel; Sabine Schulze

Abstract Stereotaxic systems and automatic tissue segmentation routines enable neuronavigation as well as reproducible processing of neuroimage datasets. Such systems have been developed for humans, non‐human‐primates, sheep, and rodents, but not for dogs. Although dogs share important neurofunctional and ‐anatomical features with humans, and in spite of their importance in translational neuroscience, little is known about the variability of the canine brain morphology and, possibly related, function. Moreover, we lack templates, tissue probability maps (TPM), and stereotaxic brain labels for implementation in standard software utilities such as Statistical Parametric Mapping (SPM). Hence, objective and reproducible, image‐based investigations are currently impeded in dogs. We have created a detailed stereotaxic reference frame for dogs including TPM and tissue labels, enabling inter‐individual and cross‐study neuroimage analysis. T2w datasets were acquired from 16 neurologically inconspicuous dogs of different breeds by 3T MRI. The datasets were averaged after initial preprocessing using linear and nonlinear registration algorithms as implemented in SPM8. TPM for gray (GM) and white matter (WM) as well as cerebrospinal fluid (CSF) were created. Different cortical, subcortical, medullary, and CSF regions were manually labeled to create a spatial binary atlas being aligned with the template. A proof‐of‐concept for automatic determination of morphological and volumetrical characteristics was performed using additional canine datasets (n = 64) including a subgroup of laboratory beagles (n = 24). Overall, 21 brain regions were labeled using the segmented tissue classes of the brain template. The proof‐of‐concept trial revealed excellent suitability of the created tools for image processing and subsequent analysis. There was high intra‐breed variability in frontal lobe and hippocampus volumes, and noticeable inter‐breed corpus callosum volume variation. The T2w brain template provides important, breed‐averaged canine brain anatomy features in a spatial standard coordinate system. TPM allows automatic tissue segmentation using SPM and enables unbiased automatic image processing or morphological characterization in different canine breeds. The reported volumetric and morphometric results may serve as a starting point for further research aimed at in vivo analysis of canine brain anatomy and function. Graphical abstract Figure. No Caption available. HighlightsA breed‐averaged MR template, probability map and 21 labels (n = 16) for dogs were established.Post‐processing were validated for various dog breeds including laboratory beagle.Mean brain tissue and label volumes were given for n = 64 dogs.Frontal lobe and hippocampus volumes are highly variable in laboratory beagle.The inter‐breed corpus callosum volume varys noticeable.

Collaboration


Dive into the Olivia W Brooks's collaboration.

Top Co-Authors

Avatar

Matthew J. Gounis

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

R King

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Ajit S. Puri

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

M Marosfoi

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

E Langan

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Frédéric Clarençon

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Ju-Yu Chueh

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Takamitsu Tamura

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Kajo van der Marel

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge