Publication


Featured researches published by Srinivasan Vedantham.


Medical Physics | 2000

Full breast digital mammography with an amorphous silicon‐based flat panel detector: Physical characteristics of a clinical prototype

Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Douglas Albagli; Sung Han; Eric J. Tkaczyk; Cynthia Elizabeth Landberg; Beale Opsahl-Ong; Paul R. Granfors; Ilias Levis; Carl J. D'Orsi; R. Edward Hendrick

The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.


Academic Radiology | 2000

Comparison of tomosynthesis methods used with digital mammography

Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Stephen J. Glick; Carl J. D'Orsi; Stephen P. Baker; Richard L. Webber

RATIONALE AND OBJECTIVES The authors performed this study to investigate the potential applicability of tomosynthesis to digital mammography. Four methods of tomosynthesis-tuned aperture computed tomography (TACT)-backprojection, TACT-iterative restoration, iterative reconstruction with expectation maximization, and Bayesian smoothing-were compared to planar mammography and analyzed in terms of their contrast-detail characteristics. Specific comparisons between the tomosynthesis methods were not attempted in this study. MATERIALS AND METHODS A full-field, amorphous, silicon-based, flat-panel digital mammographic system was used to obtain planar and tomosynthesis projection images. A composite tomosynthesis phantom with a centrally located contrast-detail insert was used as the object of interest. The total exposure for multiple views with tomosynthesis was always equal to or less than that for the planar technique. Algorithms were used to reconstruct the object from the acquired projections. RESULTS Threshold contrast characteristics with all tomosynthesis reconstruction methods were significantly better than those with planar mammography, even when planar mammography was performed at more than twice the exposure level. Reduction of out-of-plane structural components was observed in all the tomosynthesis methods analyzed. CONCLUSION The contrast-detail trends of all the tomosynthesis methods analyzed in this study were better than those of planar mammography. Further optimization of the algorithms could lead to better image reconstruction, which would improve visualization of valuable diagnostic information.


Medical Physics | 2006

Computation of the glandular radiation dose in digital tomosynthesis of the breast

Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J. D'Orsi; Andrew Karellas

Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (DgN) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the DgN to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammographic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided.


Medical Physics | 2008

Breast cancer imaging: A perspective for the next decade

Andrew Karellas; Srinivasan Vedantham

Breast imaging is largely indicated for detection, diagnosis, and clinical management of breast cancer and for evaluation of the integrity of breast implants. In this work, a prospective view of techniques for breast cancer detection and diagnosis is provided based on an assessment of current trends. The potential role of emerging techniques that are under various stages of research and development is also addressed. It appears that the primary imaging tool for breast cancer screening in the next decade will be high-resolution, high-contrast, anatomical x-ray imaging with or without depth information. MRI and ultrasonography will have an increasingly important adjunctive role for imaging high-risk patients and women with dense breasts. Pilot studies with dedicated breast CT have demonstrated high-resolution three-dimensional imaging capabilities, but several technological barriers must be overcome before clinical adoption. Radionuclide based imaging techniques and x-ray imaging with intravenously injected contrast offer substantial potential as a diagnostic tools and for evaluation of suspicious lesions. Developing optical and electromagnetic imaging techniques hold significant potential for physiologic information and they are likely to be of most value when integrated with or adjunctively used with techniques that provide anatomic information. Experimental studies with breast specimens suggest that phase-sensitive x-ray imaging techniques can provide edge enhancement and contrast improvement but more research is needed to evaluate their potential role in clinical breast imaging. From the technological perspective, in addition to improvements within each modality, there is likely to be a trend towards multi-modality systems that combine anatomic with physiologic information. We are also likely to transition from a standardized screening, where all women undergo the same imaging exam (mammography), to selection of a screening modality or modalities based an individual-risk or other classification.


Medical Physics | 2007

Scatter radiation in digital tomosynthesis of the breast

Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J. D'Orsi; Andrew Karellas

Digital tomosynthesis of the breast is being investigated as one possible solution to the problem of tissue superposition present in planar mammography. This imaging technique presents various advantages that would make it a feasible replacement for planar mammography, among them similar, if not lower, radiation glandular dose to the breast; implementation on conventional digital mammography technology via relatively simple modifications; and fast acquisition time. One significant problem that tomosynthesis of the breast must overcome, however, is the reduction of x-ray scatter inclusion in the projection images. In tomosynthesis, due to the projection geometry and radiation dose considerations, the use of an antiscatter grid presents several challenges. Therefore, the use of postacquisition software-based scatter reduction algorithms seems well justified, requiring a comprehensive evaluation of x-ray scatter content in the tomosynthesis projections. This study aims to gain insight into the behavior of x-ray scatter in tomosynthesis by characterizing the scatter point spread functions (PSFs) and the scatter to primary ratio (SPR) maps found in tomosynthesis of the breast. This characterization was performed using Monte Carlo simulations, based on the Geant4 toolkit, that simulate the conditions present in a digital tomosynthesis system, including the simulation of the compressed breast in both the cranio-caudal (CC) and the medio-lateral oblique (MLO) views. The variation of the scatter PSF with varying tomosynthesis projection angle, as well as the effects of varying breast glandular fraction and x-ray spectrum, was analyzed. The behavior of the SPR for different projection angle, breast size, thickness, glandular fraction, and x-ray spectrum was also analyzed, and computer fit equations for the magnitude of the SPR at the center of mass for both the CC and the MLO views were found. Within mammographic energies, the x-ray spectrum was found to have no appreciable effect on the scatter PSF and on the SPR. Glandular fraction and compressed breast size were found to have a small effect, while compressed breast thickness and projection angle, as expected, introduced large variations in both the scatter PSF and SPR. The presence of the breast support plate and the detector cover plate in the simulations introduced important effects on the SPR, which are also relevant to the scatter content in planar mammography.


Medical Physics | 2000

Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Ilias Levis; Michel Sayag; Robert Kleehammer; Robert Heidsieck; Carl J. D'Orsi

The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-illuminated 61 x 61 mm CCD operating at a pixel pitch of 30 microns. Objective criteria such as modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), and noise equivalent quanta (NEQ) were employed for this evaluation. The results demonstrated a limiting spatial resolution (10% MTF) of 10 cy/mm. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 40% at close to zero spatial frequency at an exposure of 8.2 mR, and decreases to approximately 28% at a low exposure of 1.1 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.


Radiology | 2015

Digital Breast Tomosynthesis: State of the Art

Srinivasan Vedantham; Andrew Karellas; Gopal Vijayaraghavan; Daniel B. Kopans

This topical review on digital breast tomosynthesis (DBT) is provided with the intent of describing the state of the art in terms of technology, results from recent clinical studies, advanced applications, and ongoing efforts to develop multimodality imaging systems that include DBT. Particular emphasis is placed on clinical studies. The observations of increase in cancer detection rates, particularly for invasive cancers, and the reduction in false-positive rates with DBT in prospective trials indicate its benefit for breast cancer screening. Retrospective multireader multicase studies show either noninferiority or superiority of DBT compared with mammography. Methods to curtail radiation dose are of importance. (©) RSNA, 2015.


Medical Physics | 2004

Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan

Cascaded linear systems based modeling techniques have been used in the past to predict important system parameters that have a direct impact on image quality. Such models are also useful in optimizing system parameters to improve image quality. In this work, detailed analysis of a solid-state fluoroscopic imaging system intended for high-resolution angiography is presented with the use of such a model. The imaging system analyzed through this model uses four 8 x 8 cm three-side buttable interlined charge-coupled devices (CCDs) specifically designed for high-resolution angiography and tiled in a seamless fashion to achieve a field of view (FOV) of 16 x 16 cm. Larger FOVs can be achieved by tiling more CCDs in a similar manner. The system employs a CsI:Tl scintillator coupled to the CCDs by straight (nontapering) fiberoptics and can potentially be operated in 78, 156, or 234 microm pixel pitch modes. The system parameters analyzed through this model include presampling modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). The results of the simulations performed indicate that DQE(0) in excess of 0.6 is achievable, with the imager operating at 156 microm pixel pitch, 30 frames/s, and employing a 450-microm-thick CsI:Tl scintillator, even at a low fluoroscopic exposure rate of 1 microR/frame. Further, at a nominal fluoroscopic exposure rate of 2.5 microR/frame there was no noticeable degradation of the DQE even at the 78 microm pixel pitch mode suggesting that it is feasible to perform high-resolution angiography hitherto unattainable in clinical practice.


Arteriosclerosis, Thrombosis, and Vascular Biology | 2011

Human Aldose Reductase Expression Accelerates Atherosclerosis in Diabetic Apolipoprotein E−/− Mice

Srinivasan Vedantham; Hye-Lim Noh; Radha Ananthakrishnan; Ni Son; Kellie Hallam; Yunying Hu; Shuiquing Yu; Xiaoping Shen; Rosa Rosario; Yan Lu; Thyyar M. Ravindranath; Konstantinos Drosatos; Lesley Ann Huggins; Ann Marie Schmidt; Ira J. Goldberg; Ravichandran Ramasamy

Objective—There are several pathways that mediate the aberrant metabolism of glucose and that might induce greater vascular damage in the setting of diabetes. The polyol pathway mediated by aldose reductase (AR) has been postulated to be one such pathway. However, it has been reported that AR reduces toxic lipid aldehydes and, under some circumstances, might be antiatherogenic. Methods and Results—Atherosclerosis development was quantified in 2 lines of transgenic mice expressing human AR (hAR) crossed on the apolipoprotein E knockout background. The transgenes were used to increase the normally low levels of this enzyme in wild-type mice. Both generalized hAR overexpression and hAR expression via the Tie 2 promoter increased lesion size in streptozotocin diabetic mice. In addition, pharmacological inhibition of AR reduced lesion size. Conclusion—Although in some settings AR expression might reduce levels of toxic aldehydes, transgenic expression of this enzyme within the artery wall leads to greater atherosclerosis.


Medical Imaging 2002: Physics of Medical Imaging | 2002

Investigation of optimal kVp settings for CT mammography using a flat-panel imager

Stephen J. Glick; Srinivasan Vedantham; Andrew Karellas

Detection of lesions in planar mammograms is a difficult task, predominantly due to the masking effect of superimposed parenchymal breast patterns. Tomographic imaging of the breast can provide image slices through the breast, possibly reducing this masking effect. In recent years, there has been interest in developing CT mammography using flat-panel digital detectors in a truncated cone-beam geometry. In this study, we have developed a framework for determining optimal design and acquisition parameters for such a CT mammographic system. The ideal observer SNR is used as a figure-of-merit, under the assumptions that the imaging system is linear and shift-invariant, and that the noise is stationary. The ideal observer calculation uses mathematical models of signal and noise propagation through the flat-panel detector, and realistic models of the lesion detection task in breast imaging. It is used to investigate optimal kVp settings of a tungsten anode spectra for CT imaging of the uncompressed breast, given the constraint of an average glandular dose approximately equivalent to that of a two-view planar mammography study. It is observed that modeling a realistic mammographic background structure into the detection task can affect the optimal kVp settings suggested by the ideal observer SNR. Since the exposure/view in flat-panel CT mammography is considerably lower than for planar mammography, it is observed that electronic additive noise can also affect the optimal kVp setting. In general, the optimal kVp settings for the tungsten anode spectra studied here were in the range of 30-50 kVp.

Collaboration


Dive into the Srinivasan Vedantham's collaboration.

Top Co-Authors

Avatar

Andrew Karellas

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Linxi Shi

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge