Olivier Delémont
University of Lausanne
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Olivier Delémont.
Forensic Science International | 2010
Olivier Ribaux; Amélie Baylon; Claude Roux; Olivier Delémont; Eric Lock; Christian Zingg; Pierre Margot
Forensic science is generally defined as the application of science to address questions related to the law. Too often, this view restricts the contribution of science to one single process which eventually aims at bringing individuals to court while minimising risk of miscarriage of justice. In order to go beyond this paradigm, we propose to refocus the attention towards traces themselves, as remnants of a criminal activity, and their information content. We postulate that traces contribute effectively to a wide variety of other informational processes that support decision making in many situations. In particular, they inform actors of new policing strategies who place the treatment of information and intelligence at the centre of their systems. This contribution of forensic science to these security oriented models is still not well identified and captured. In order to create the best condition for the development of forensic intelligence, we suggest a framework that connects forensic science to intelligence-led policing (part I). Crime scene attendance and processing can be envisaged within this view. This approach gives indications about how to structure knowledge used by crime scene examiners in their effective practice (part II).
Forensic Science International | 2010
Olivier Ribaux; Amélie Baylon; Eric Lock; Olivier Delémont; Claude Roux; Christian Zingg; Pierre Margot
A better integration of the information conveyed by traces within intelligence-led framework would allow forensic science to participate more intensively to security assessments through forensic intelligence (part I). In this view, the collection of data by examining crime scenes is an entire part of intelligence processes. This conception frames our proposal for a model that promotes to better use knowledge available in the organisation for driving and supporting crime scene examination. The suggested model also clarifies the uncomfortable situation of crime scene examiners who must simultaneously comply with justice needs and expectations, and serve organisations that are mostly driven by broader security objectives. It also opens new perspective for forensic science and crime scene investigation, by the proposal to follow other directions than the traditional path suggested by dominant movements in these fields.
Forensic Science International | 2015
Natacha Gentile; Rolf T. W. Siegwolf; Pierre Esseiva; Sean Doyle; Kurt Zollinger; Olivier Delémont
Isotope ratio mass spectrometry (IRMS) has been used in numerous fields of forensic science in a source inference perspective. This review compiles the studies published on the application of isotope ratio mass spectrometry (IRMS) to the traditional fields of forensic science so far. It completes the review of Benson et al. [1] and synthesises the extent of knowledge already gathered in the following fields: illicit drugs, flammable liquids, human provenancing, microtraces, explosives and other specific materials (packaging tapes, safety matches, plastics, etc.). For each field, a discussion assesses the state of science and highlights the relevance of the information in a forensic context. Through the different discussions which mark out the review, the potential and limitations of IRMS, as well as the needs and challenges of future studies are emphasized. The paper elicits the various dimensions of the source which can be obtained from the isotope information and demonstrates the transversal nature of IRMS as a tool for source inference.
Forensic Science International | 2011
Natacha Gentile; Luc Besson; Diego Pazos; Olivier Delémont; Pierre Esseiva
The flourishing number of publications on the use of isotope ratio mass spectrometry (IRMS) in forensic science denotes the enthusiasm and the attraction generated by this technology. IRMS has demonstrated its potential to distinguish chemically identical compounds coming from different sources. Despite the numerous applications of IRMS to a wide range of forensic materials, its implementation in a forensic framework is less straightforward than it appears. In addition, each laboratory has developed its own strategy of analysis on calibration, sequence design, standards utilisation and data treatment without a clear consensus. Through the experience acquired from research undertaken in different forensic fields, we propose a methodological framework of the whole process using IRMS methods. We emphasize the importance of considering isotopic results as part of a whole approach, when applying this technology to a particular forensic issue. The process is divided into six different steps, which should be considered for a thoughtful and relevant application. The dissection of this process into fundamental steps, further detailed, enables a better understanding of the essential, though not exhaustive, factors that have to be considered in order to obtain results of quality and sufficiently robust to proceed to retrospective analyses or interlaboratory comparisons.
Environmental Science & Technology | 2014
Frederic Been; Luca Rossi; Christophe Ort; Serge Rudaz; Olivier Delémont; Pierre Esseiva
Fluctuations in ammonium (NH4+), measured as NH4-N loads using an ion-selective electrode installed at the inlet of a sewage treatment plant, showed a distinctive pattern which was associated to weekly (i.e., commuters) and seasonal (i.e., holidays) fluctuations of the population. Moreover, population size estimates based on NH4-N loads were lower compared to census data. Diurnal profiles of benzoylecgonine (BE) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) were shown to be strongly correlated to NH4-N. Characteristic patterns, which reflect the prolonged nocturnal activity of people during the weekend, could be observed for BE, cocaine, and a major metabolite of MDMA (i.e., 4-hydroxy-3-methoxymethamphetamine). Additional 24 h composite samples were collected between February and September 2013. Per-capita loads (i.e., grams per day per 1000 inhabitants) were computed using census data and NH4-N measurements. Normalization with NH4-N did not modify the overall pattern, suggesting that the magnitude of fluctuations in the size of the population is negligible compared to those of illicit drug loads. Results show that fluctuations in the size of the population over longer periods of time or during major events can be monitored using NH4-N loads: either using raw NH4-N loads or population size estimates based on NH4-N loads, if information about site-specific NH4-N population equivalents is available.
Drug and Alcohol Dependence | 2016
Frederic Been; Lubertus Bijlsma; Lisa Benaglia; Jean Daniel Berset; A.M. Botero-Coy; Sara Castiglioni; Ludwig Kraus; Frank Zobel; Michael P Schaub; Alexander Bücheli; Félix Hernández; Olivier Delémont; Pierre Esseiva; Christoph Ort
BACKGROUND Wastewater analysis is an innovative approach that allows monitoring illicit drug use at the community level. This study focused on investigating geographical differences in drug consumption by comparing epidemiological, crime and wastewater data. METHODS Wastewater samples were collected in 19 cities across Germany and Switzerland during one week, covering a population of approximately 8.1 million people. Self-report data and consumption offences for the investigated areas were used for comparison and to investigate differences between the indicators. RESULTS Good agreement between data sources was observed for cannabis and amphetamine-type stimulants, whereas substantial discrepancies were observed for cocaine. In Germany, an important distinction could be made between Berlin, Dortmund and Munich, where cocaine and particularly amphetamine were more prevalent, and Dresden, where methamphetamine consumption was clearly predominant. Cocaine consumption was relatively homogenous in the larger urban areas of Switzerland, although prevalence and offences data suggested a more heterogeneous picture. Conversely, marked regional differences in amphetamine and methamphetamine consumption could be highlighted. CONCLUSIONS Combining the available data allowed for a better understanding of the geographical differences regarding prevalence, typology and amounts of substances consumed. For cannabis and amphetamine-type stimulants, the complementarity of survey, police and wastewater data could be highlighted, although notable differences could be identified when considering more stigmatised drugs (i.e. cocaine and heroin). Understanding illicit drug consumption at the national scale remains a difficult task, yet this research illustrates the added value of combining complementary data sources to obtain a more comprehensive and accurate picture of the situation.
Forensic Science International | 2009
Federica Bonadio; Pierre Margot; Olivier Delémont; Pierre Esseiva
A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 degrees C for 15 min, followed by extraction at 80 degrees C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.
Drug and Alcohol Dependence | 2015
Frederic Been; Lisa Benaglia; Sonia Lucia; Jean-Pierre Gervasoni; Pierre Esseiva; Olivier Delémont
BACKGROUND The need to contextualise wastewater-based figures about illicit drug consumption by comparing them with other indicators has been stressed by numerous studies. The objective of the present study was to further investigate the possibility of combining wastewater data to conventional statistics to assess the reliability of the former method and obtain a more balanced picture of illicit drug consumption in the investigated area. METHODS Wastewater samples were collected between October 2013 and July 2014 in the metropolitan area of Lausanne (226,000 inhabitants), Switzerland. Methadone, its metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), the exclusive metabolite of heroin, 6-monoacetylmorphine (6-MAM), and morphine loads were used to estimate the amounts of methadone and heroin consumed. RESULTS Methadone consumption estimated from EDDP was in agreement with the expectations. Heroin estimates based on 6-MAM loads were inconsistent. Estimates obtained from morphine loads, combined to prescription/sales data, were in agreement with figures derived from syringe distribution data and general population surveys. CONCLUSIONS The results obtained for methadone allowed assessing the reliability of the selected sampling strategy, supporting its ability to capture the consumption of a small cohort (i.e., 743 patients). Using morphine as marker, in combination with prescription/sales data, estimates in accordance with other indicators about heroin use were obtained. Combining different sources of data allowed strengthening the results and suggested that the different indicators (i.e., administration route, average dosage and number of consumers) contribute to depict a realistic representation of the phenomenon in the investigated area. Heroin consumption was estimated to approximately 13 gd ay(-1) (118 g day(-1) at street level).
Forensic Science International | 2008
Federica Bonadio; Pierre Margot; Olivier Delémont; Pierre Esseiva
Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.
Analytical and Bioanalytical Chemistry | 2013
Natacha Gentile; Michel J. Rossi; Olivier Delémont; Rolf T. W. Siegwolf
AbstractLittle attention has been paid so far to the influence of the chemical nature of the substance when measuring δ15N by elemental analysis (EA)–isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2—two ammonium sulphates [(NH4)2SO4]—and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards. FigureControl chart of the δ15N value of IAEA-N1, IAEA-NO-3 and NH4NO3 analysed a) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 18 s/20 s), b) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 0 s/2 s and 5 s/7 s), c) without oxygen injection (analytical cycle 70 s, sample start and stop at 18 s/20 s).