Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Omar Yassine is active.

Publication


Featured researches published by Omar Yassine.


Angewandte Chemie | 2016

H2S Sensors: Fumarate‐Based fcu‐MOF Thin Film Grown on a Capacitive Interdigitated Electrode

Omar Yassine; Osama Shekhah; Ayalew H. Assen; Youssef Belmabkhout; Khaled N. Salama; Mohamed Eddaoudi

Herein we report the fabrication of an advanced sensor for the detection of hydrogen sulfide (H2 S) at room temperature, using thin films of rare-earth metal (RE)-based metal-organic framework (MOF) with underlying fcu topology. This unique MOF-based sensor is made via the in situ growth of fumarate-based fcu-MOF (fum-fcu-MOF) thin film on a capacitive interdigitated electrode. The sensor showed a remarkable detection sensitivity for H2 S at concentrations down to 100 ppb, with the lower detection limit around 5 ppb. The fum-fcu-MOF sensor exhibits a highly desirable detection selectivity towards H2 S vs. CH4 , NO2 , H2 , and C7 H8 as well as an outstanding H2 S sensing stability as compared to other reported MOFs.


IEEE Sensors Journal | 2015

A Surface Acoustic Wave Passive and Wireless Sensor for Magnetic Fields, Temperature, and Humidity

Bodong Li; Omar Yassine; Jürgen Kosel

In this paper, we report an integrated single-chip surface acoustic wave sensor with the capability of measuring magnetic field, temperature, and humidity. The sensor is fabricated using a thermally sensitive LiNbO3 substrate, a humidity sensitive hydrogel coating, and a magnetic field sensitive impedance load. The sensor response to individually and simultaneously changing magnetic field, temperature and humidity is characterized by connecting a network analyzer directly to the sensor. Analytical models for each measurand are derived and used to compensate noise due to cross sensitivities. The results show that all three measurands can be monitored in parallel with sensitivities of 75 ppm/°C, 0.13 dB/%R.H. (at 50%R.H.), 0.18 dB/Oe and resolutions of 0.1 °C, 0.4%R.H., 1 Oe for temperature, humidity and magnetic field, respectively. A passive wireless measurement is also conducted on a current line using, which shows the sensors capability to measure both temperature and current signals simultaneously.


ACS Sensors | 2017

MOFs for the Sensitive Detection of Ammonia: Deployment of fcu-MOF Thin Films as Effective Chemical Capacitive Sensors

Ayalew H. Assen; Omar Yassine; Osama Shekhah; Mohamed Eddaoudi; Khaled N. Salama

This work reports on the fabrication and deployment of a select metal-organic framework (MOF) thin film as an advanced chemical capacitive sensor for the sensing/detection of ammonia (NH3) at room temperature. Namely, the MOF thin film sensing layer consists of a rare-earth (RE) MOF (RE-fcu-MOF) deposited on a capacitive interdigitated electrode (IDE). Purposely, the chemically stable naphthalene-based RE-fcu-MOF (NDC-Y-fcu-MOF) was elected and prepared/arranged as a thin film on a prefunctionalized capacitive IDE via the solvothermal growth method. Unlike earlier realizations, the fabricated MOF-based sensor showed a notable detection sensitivity for NH3 at concentrations down to 1 ppm, with a detection limit appraised to be around 100 ppb (at room temperature) even in the presence of humidity and/or CO2. Distinctly, the NDC-Y-fcu-MOF based sensor exhibited the required stability to NH3, in contrast to other reported MOFs, and a remarkable detection selectivity toward NH3 vs CH4, NO2, H2, and C7H8. The NDC-Y-fcu-MOF based sensor exhibited excellent performance for sensing ammonia for simulated breathing system in the presence of the mixture of carbon dioxide and/or humidity (water vapor), with no major alteration in the detection signal.


Biomicrofluidics | 2014

Isolation of cells for selective treatment and analysis using a magnetic microfluidic chip

Omar Yassine; Chinthaka P. Gooneratne; D. Abu Smara; Fuquan Li; Hanan Mohammed; J. Merzaban; Jürgen Kosel

This study describes the development and testing of a magnetic microfluidic chip (MMC) for trapping and isolating cells tagged with superparamagnetic beads (SPBs) in a microfluidic environment for selective treatment and analysis. The trapping and isolation are done in two separate steps; first, the trapping of the tagged cells in a main channel is achieved by soft ferromagnetic disks and second, the transportation of the cells into side chambers for isolation is executed by tapered conductive paths made of Gold (Au). Numerical simulations were performed to analyze the magnetic flux and force distributions of the disks and conducting paths, for trapping and transporting SPBs. The MMC was fabricated using standard microfabrication processes. Experiments were performed with E. coli (K12 strand) tagged with 2.8 μm SPBs. The results showed that E. coli can be separated from a sample solution by trapping them at the disk sites, and then isolated into chambers by transporting them along the tapered conducting paths. Once the E. coli was trapped inside the side chambers, two selective treatments were performed. In one chamber, a solution with minimal nutrition content was added and, in another chamber, a solution with essential nutrition was added. The results showed that the growth of bacteria cultured in the second chamber containing nutrient was significantly higher, demonstrating that the E. coli was not affected by the magnetically driven transportation and the feasibility of performing different treatments on selectively isolated cells on a single microfluidic platform.


Scientific Reports | 2016

Highly Efficient Thermoresponsive Nanocomposite for Controlled Release Applications

Omar Yassine; Amir Zaher; Er Qiang Li; Ahmed Alfadhel; Jose E. Perez; Mincho Kavaldzhiev; Maria F. Contreras; Sigurdur T. Thoroddsen; Niveen M. Khashab; Jürgen Kosel

Highly efficient magnetic release from nanocomposite microparticles is shown, which are made of Poly (N-isopropylacrylamide) hydrogel with embedded iron nanowires. A simple microfluidic technique was adopted to fabricate the microparticles with a high control of the nanowire concentration and in a relatively short time compared to chemical synthesis methods. The thermoresponsive microparticles were used for the remotely triggered release of Rhodamine (B). With a magnetic field of only 1 mT and 20 kHz a drug release of 6.5% and 70% was achieved in the continuous and pulsatile modes, respectively. Those release values are similar to the ones commonly obtained using superparamagnetic beads but accomplished with a magnetic field of five orders of magnitude lower power. The high efficiency is a result of the high remanent magnetization of the nanowires, which produce a large torque when exposed to a magnetic field. This causes the nanowires to vibrate, resulting in friction losses and heating. For comparison, microparticles with superparamagnetic beads were also fabricated and tested; while those worked at 73 mT and 600 kHz, no release was observed at the low field conditions. Cytotoxicity assays showed similar and high cell viability for microparticles with nanowires and beads.


Biomicrofluidics | 2015

A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve

Ying Yi; Amir Zaher; Omar Yassine; Jürgen Kosel; Ian G. Foulds

Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valves closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled.


IEEE Transactions on Magnetics | 2013

Selective Manipulation of Superparamagnetic Beads by a Magnetic Microchip

Chinthaka P. Gooneratne; Omar Yassine; Ioanna Giouroudi; Jürgen Kosel

In this paper, a magnetic microchip (MMC) is presented, to first trap and then selectively manipulate individual, superparamagnetic beads (SPBs) to another trapping site. Trapping sites are realized through soft magnetic micro disks made of Ni80Fe20, and SPB motion is controlled by current-carrying, tapered, conducting lines made of Au. The MMC was realized using standard microfabrication techniques and provides a cheap and versatile platform for microfluidic systems for cell manipulation.


Sensors | 2016

Nonlinear-Based MEMS Sensors and Active Switches for Gas Detection

Adam Bouchaala; Nizar Jaber; Omar Yassine; Osama Shekhah; Valeriya Chernikova; Mohamed Eddaoudi; Mohammad I. Younis

The objective of this paper is to demonstrate the integration of a MOF thin film on electrostatically actuated microstructures to realize a switch triggered by gas and a sensing algorithm based on amplitude tracking. The devices are based on the nonlinear response of micromachined clamped-clamped beams. The microbeams are coated with a metal-organic framework (MOF), namely HKUST-1, to achieve high sensitivity. The softening and hardening nonlinear behaviors of the microbeams are exploited to demonstrate the ideas. For gas sensing, an amplitude-based tracking algorithm is developed to quantify the captured quantity of gas. Then, a MEMS switch triggered by gas using the nonlinear response of the microbeam is demonstrated. Noise analysis is conducted, which shows that the switch has high stability against thermal noise. The proposed switch is promising for delivering binary sensing information, and also can be used directly to activate useful functionalities, such as alarming.


Journal of Materials Chemistry | 2018

Highly sensitive and selective SO2 MOF sensor: the integration of MFM-300 MOF as a sensitive layer on a capacitive interdigitated electrode

Valeriya Chernikova; Omar Yassine; Osama Shekhah; Mohamed Eddaoudi; Khaled N. Salama

We report on the fabrication of an advanced chemical capacitive sensor for the detection of sulfur dioxide (SO2) at room temperature. The sensing layer based on an indium metal–organic framework (MOF), namely MFM-300, is coated solvothermally on a functionalized capacitive interdigitated electrode. The fabricated sensor exhibits significant detection sensitivity to SO2 at concentrations down to 75 ppb, with the lower detection limit estimated to be around 5 ppb. The MFM-300 MOF sensor demonstrates highly desirable detection selectivity towards SO2vs. CH4, CO2, NO2 and H2, as well as an outstanding SO2 sensing stability.


ieee sensors | 2013

Integrated passive and wireless sensor for magnetic fields, temperature and humidity

Bodong Li; Omar Yassine; Jürgen Kosel

This paper presents a surface acoustic wave-based passive and wireless sensor that can measure magnetic field, temperature and humidity. A thin film giant magnetoimpedance sensor, a thermally sensitive LiNbO3 substrate and a humidity sensitive hydrogel are integrated together with a surface acoustic wave transducer to realize the multifunctional sensor. The device is characterized using a network analyzer under sequentially changing humidity, temperature and magnetic field conditions. The first hand results show the sensor response to all three sensing parameters with small temperature interference on the magnetic signals.

Collaboration


Dive into the Omar Yassine's collaboration.

Top Co-Authors

Avatar

Jürgen Kosel

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Khaled N. Salama

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Mohamed Eddaoudi

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Osama Shekhah

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Amir Zaher

University of British Columbia

View shared research outputs
Top Co-Authors

Avatar

Ayalew H. Assen

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Ahmed Alfadhel

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Bodong Li

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Xixiang Zhang

King Abdullah University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Youssef Belmabkhout

King Abdullah University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge