Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where P. Foladori is active.

Publication


Featured researches published by P. Foladori.


Water intelligence online | 2010

Sludge Reduction Technologies in Wastewater Treatment Plants

P. Foladori; Gianni Andreottola; G. Ziglio

Sludge Reduction Technologies in Wastewater Treatment Plants is a review of the sludge reduction techniques integrated in wastewater treatment plants with detailed chapters on the most promising and most widespread techniques. The aim of the book is to update the international community on the current status of knowledge and techniques in the field of sludge reduction. It will provide a comprehensive understanding of the following issues in sludge reduction: This book will be essential reading for managers and technical staff of wastewater treatment plants as well as graduate students and post-graduate specialists. ISBN: 9781843392781 (Print) ISBN: 9781780401706 (eBook)


Water Research | 2002

Assessment of activated sludge viability with flow cytometry

G. Ziglio; Gianni Andreottola; Silvia Barbesti; Giorgio Boschetti; Laura Bruni; P. Foladori; Roberta Villa

The aim of the study was to evaluate the applicability of fluorescent dyes and multiparameter flow cytometry for the rapid and direct viability/activity assessment of activated sludge samples taken from wastewater treatment plants. Viability and activity of the biomass were estimated respectively through cellular membrane integrity, staining with SYBR Green I and Propidium Iodide, and through fluorogenic dyes capable of detecting enzymatic activity, as FDA and BCECF-AM. A procedure has been developed to disaggregate sludge flocs before dyes staining and cytometric analysis. The developed procedure allows a high recovery of bacteria with good accuracy and repeatability, and minimize the damage of the cells suspension obtained from the disaggregation of the flocs. These measurements were applied to estimate the two main parameters required to define the biological activated sludge process: the endogenous decay rate and the specific growth rate in exponential phase with high F/M ratio. Oxygen utilization rate measurements (OUR) were conducted to conventionally monitor the activity of the biomass. The preliminary data are encouraging and support the possibility to investigate bacteria dynamics on wastewater treatment plants.


Water Research | 2010

Direct quantification of bacterial biomass in influent, effluent and activated sludge of wastewater treatment plants by using flow cytometry

P. Foladori; Laura Bruni; S. Tamburini; G. Ziglio

A rapid multi-step procedure, potentially amenable to automation, was proposed for quantifying viable and active bacterial cells, estimating their biovolume using flow cytometry (FCM) and to calculate their biomass within the main stages of a wastewater treatment plant: raw wastewater, settled wastewater, activated sludge and effluent. Fluorescent staining of bacteria using SYBR-Green I + Propidium Iodide (to discriminate cell integrity or permeabilisation) and BCECF-AM (to identify enzymatic activity) was applied to count bacterial cells by FCM. A recently developed specific procedure was applied to convert Forward Angle Light Scatter measured by FCM into the corresponding bacterial biovolume. This conversion permits the calculation of the viable and active bacterial biomass in wastewater, activated sludge and effluent, expressed as Volatile Suspended Solids (VSS) or particulate Chemical Oxygen Demand (COD). Viable bacterial biomass represented only a small part of particulate COD in raw wastewater (4.8 +/- 2.4%), settled wastewater (10.7 +/- 3.1%), activated sludge (11.1 +/- 2.1%) and effluent (3.2 +/- 2.2%). Active bacterial biomass counted for a percentage of 30-47% of the viable bacterial biomass within the stages of the wastewater treatment plant.


Water Research | 2008

Use of silica microspheres having refractive index similar to bacteria for conversion of flow cytometric forward light scatter into biovolume

P. Foladori; A. Quaranta; G. Ziglio

This research describes an alternative approach for the rapid conversion of flow cytometric Forward Angle Light Scattering (FALS) into bacterial biovolume. The Rayleigh-Gans theory was considered for explaining the main parameters affecting FALS intensity: sensitivity analysis of the model was carried out, taking into account the parameters characteristic of bacterial cells and characteristics of the flow cytometer. For particles with size in the typical range of bacteria, the FALS intensity is affected mainly by volume and refractive index of bacterial cells and is approximately independent of the shape of the cells. The proposed conversion from FALS intensity into bacterial biovolume is based on a calibration curve determined by using silica microspheres having relative refractive index as far as possible similar to that of bacteria. The approach was validated for two different flow cytometers (the first equipped with an arc lamp and the second with a laser) by comparing the biovolume distribution obtained from FALS conversion with the biovolume measured conventionally under epifluorescence microscopy. The specific case of bacteria taken from a WWTP was addressed. Compared to the time-consuming conventional microscopic approach, the application of FALS for sizing bacterial biovolume could be a very promising tool being completed in few minutes, simultaneously to the enumeration of bacteria during the flow cytometric analysis.


Water Research | 2010

Bacteria permeabilisation and disruption caused by sludge reduction technologies evaluated by flow cytometry

P. Foladori; S. Tamburini; L. Bruni

Technologies proposed in the last decades for the reduction of the sludge production in wastewater treatment plants and based on the mechanism of cell lysis-cryptic growth (physical, mechanical, thermal, chemical, oxidative treatments) have been widely investigated at lab-, pilot- and, in some cases, at full-scale but the effects on cellular lysis have not always been demonstrated in depth. The research presented in this paper aims to investigate how these sludge reduction technologies affect the integrity and permeabilization of bacterial cells in sludge using flow cytometry (FCM), which permits the rapid and statistically accurate quantification of intact, permeabilised or disrupted bacteria in the sludge using a double fluorescent DNA-staining instead of using conventional methods like plate counts and microscope. Physical/mechanical treatments (ultrasonication and high pressure homogenisation) caused moderate effects on cell integrity and caused significant cell disruption only at high specific energy levels. Conversely, thermal treatment caused significant damage of bacterial membranes even at moderate temperatures (45-55 °C). Ozonation significantly affected cell integrity, even at low ozone dosages, below 10 mgO(3)/gTSS, causing an increase of permeabilised and disrupted cells. At higher ozone dosages the compounds solubilised after cell lysis act as scavengers in the competition between soluble compounds and (particulate) bacterial cells. An original aspect of this paper, not yet reported in the literature, is the comparison of the effects of these sludge reduction technologies on bacterial cell integrity and permeabilization by converting pressure, temperature and ozone dosage to an equivalent value of specific energy. Among these technologies, comparison of the applied specific energy demonstrates that achieving the complete disruption of bacterial cells is not always economically advantageous because excessive energy levels may be required.


Bioresource Technology | 2013

Recirculation or artificial aeration in vertical flow constructed wetlands: A comparative study for treating high load wastewater

P. Foladori; Jenny Ruaben; Angela R.C. Ortigara

Vertical subsurface-flow constructed wetlands at pilot-scale have been applied to treat high hydraulic and organic loads by implementing the following configurations: (1) intermittent recirculation of the treated wastewater from the bottom to the top of the bed, (2) intermittent artificial aeration supplied at the bottom of the bed and (3) the combination of both. These configurations were operated with a saturated bottom layer for a 6h-treatment phase, followed by a free drainage phase prior to a new feeding. COD removal efficiency was 85-90% in all the configurations and removed loads were 54-70 gCOD m(-2)d(-1). The aerated and recirculated wetland resulted in a higher total nitrogen removal (8.6 gN m(-2)d(-1)) due to simultaneous nitrification/denitrification, even in the presence of intermittent aeration (6.8 Nm(3)m(-2)d(-1)). The extra investment needed for implementing aeration/recirculation would be compensated for by a reduction of the surface area per population equivalent, which decreased to 1.5m(2)/PE.


Applied and Environmental Microbiology | 2004

Effects of the Metalloid Oxyanion Tellurite (TeO32−) on Growth Characteristics of the Phototrophic Bacterium Rhodobacter capsulatus

Roberto Borghese; Francesca Borsetti; P. Foladori; G. Ziglio; Davide Zannoni

ABSTRACT This work examines the effects of potassium tellurite (K2TeO3) on the cell viability of the facultative phototroph Rhodobacter capsulatus. There was a growth mode-dependent response in which cultures anaerobically grown in the light tolerate the presence of up to 250 to 300 μg of tellurite (TeO32−) per ml, while dark-grown aerobic cells were inhibited at tellurite levels as low as 2 μg/ml. The tellurite sensitivity of aerobic cultures was evident only for growth on minimal salt medium, whereas it was not seen during growth on complex medium. Notably, through the use of flow cytometry, we show that the cell membrane integrity was strongly affected by tellurite during the early growth phase (≤50% viable cells); however, at the end of the growth period and in parallel with massive tellurite intracellular accumulation as elemental Te0 crystallites, recovery of cytoplasmic membrane integrity was apparent (≥90% viable cells), which was supported by the development of a significant membrane potential (Δψ = 120 mV). These data are taken as evidence that in anaerobic aquatic habitats, the facultative phototroph R. capsulatus might act as a natural scavenger of the highly soluble and toxic oxyanion tellurite.


Water Science and Technology | 2009

Biological treatment of winery wastewater: an overview.

Gianni Andreottola; P. Foladori; G. Ziglio

The treatment of winery wastewater can realised using several biological processes based both on aerobic or anaerobic systems using suspended biomass or biofilms. Several systems are currently offered by technology providers and current research envisages the availability of new promising technologies for winery wastewater treatment. The present paper intends to present a brief state of the art of the existing status and advances in biological treatment of winery wastewater in the last decade, considering both lab, pilot and full-scale studies. Advantages, drawbacks, applied organic loads, removal efficiency and emerging aspects of the main biological treatments were considered and compared. Nevertheless in most treatments the COD removal efficiency was around 90-95% (remaining COD is due to the un-biodegradable soluble fraction), the applied organic loads are very different depending on the applied technology, varying for an order of magnitude. Applied organic loads are higher in biofilm systems than in suspended biomass while anaerobic biofilm processes have the smaller footprint but in general a higher level of complexity.


Journal of Environmental Science and Health Part A-toxic\/hazardous Substances & Environmental Engineering | 2003

Upgrading of a Small Overloaded Activated Sludge Plant Using a MBBR System

Gianni Andreottola; P. Foladori; G. Gatti; P. Nardelli; M. Pettena; M. Ragazzi

Abstract The aim of this research was the application of a biofilm system for the upgrading of a full-scale overloaded activated sludge MWWTP using the MBBR (Moving Bed Biofilm Reactor) technology. The choice of this fixed biomass system appeared appropriate because it offers several advantages including good potential in nitrification process, easiness of management and above all, the possibility to use the existing tank with very few modifications. MBBR system counts only few full-scale plants in Italy at the moment, thus a pilot-scale experimentation was preliminarily carried out. The acquired parameters were used for the full-scale MWWTP upgrading. The upgrading of the activated sludge reactor in the MBBR system has given (1) a relevant increase in the flowrate treated up to 60%; (2) a good efficiency in organic carbon removal and nitrification, equal to 88% and 90% respectively, with HRTs of 5.5–7 h; (3) the overcoming of the hydraulic overload of the secondary settler, applying a lamellar settler. It was observed a good correlation between the results obtained at pilot-scale and those observed in the full-scale plant.


Water Science and Technology | 2012

Influence of high organic loads during the summer period on the performance of hybrid constructed wetlands (VSSF + HSSF) treating domestic wastewater in the Alps region

P. Foladori; A. R. C. Ortigara; J. Ruaben; Gianni Andreottola

One of the limits for the application of constructed wetlands (CWs) in mountain regions (such as the Alps) is associated with the considerable land area requirements. In some mountain areas, the treatment of domestic wastewater at popular tourist destinations is particularly difficult during the summer, when the presence of visitors increases hydraulic and organic loads. This paper aims to evaluate whether a hybrid CW plant designed on the basis of the resident population only, can treat also the additional load produced by the floating population during the tourist period (summer, when temperatures are favourable for biological treatment), without a drastic decrease of efficiency and without clogging problems. The research was carried out by considering two operational periods: the first one was based on literature indications (3.2 m(2)/PE in the VSSF unit) and the second one assumed higher hydraulic and organic loads (1.3 m(2)/PE in the VSSF unit). The removal efficiency in the hybrid CW system decreased slightly from 94 to 88% for COD removal and from 78 to 75% for total N removal, even after applying a double hydraulic (from 55 to 123 L m(-2) d(-1)) and organic load (from 37 to 87 g COD m(-2) d(-1) and from 4.4 to 10.3 g TKN m(-2) d(-1)). The results showed that in the summer period the application of high loads did not affect the efficiency of the hybrid CW plant significantly, suggesting that it is possible to refer the CW design to the resident population only, with subsequent considerable savings in superficial area.

Collaboration


Dive into the P. Foladori's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge