P. Santos
University of Aveiro
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by P. Santos.
Journal of Biomechanics | 2013
Marco Soares dos Santos; Jorge Ferreira; A. Ramos; José A. Simões; Raul Morais; Nuno M. Silva; P. Santos; Múcio Silva Reis; Tâmara Rebecca Albuquerque de Oliveira
Instrumented hip implants were proposed as a method to monitor and predict the biomechanical and thermal environment surrounding such implants. Nowadays, they are being developed as active implants with the ability to prevent failures by loosening. The generation of electric energy to power active mechanisms of instrumented hip implants remains a question. Instrumented implants cannot be implemented without effective electric power systems. This paper surveys the power supply systems of seventeen implant architectures already implanted in-vivo, namely from instrumented hip joint replacements and instrumented fracture stabilizers. Only inductive power links and batteries were used in-vivo to power the implants. The energy harvesting systems, which were already designed to power instrumented hip implants, were also analyzed focusing their potential to overcome the disadvantages of both inductive-based and battery-based power supply systems. From comparative and critical analyses of the methods to power instrumented implants, one can conclude that: inductive powering and batteries constrain the full operation of instrumented implants; motion-driven electromagnetic energy harvesting is a promising method to power instrumented passive and active hip implants.
Expert Review of Medical Devices | 2014
Marco Soares dos Santos; Jorge Ferreira; A. Ramos; José Simões; Raul Morais; Nuno M. Silva; P. Santos; Manuel J. C. S. Reis; Tatiana Oliveira
This paper reviews instrumented hip joint replacements, instrumented femoral replacements and instrumented femoral fracture stabilizers. Examination of the evolution of such implants was carried out, including the detailed analysis of 16 architectures, designed by 8 research teams and implanted in 32 patients. Their power supply, measurement, communication, processing and actuation systems were reviewed, as were the tests carried out to evaluate their performance and safety. These instrumented implants were only designed to measure biomechanical and thermodynamic quantities in vivo, in order to use such data to conduct research projects and optimize rehabilitation processes. The most promising trend is to minimize aseptic loosening and/or infection following hip or femoral replacements or femoral stabilization procedures by using therapeutic actuators inside instrumented implants to apply controlled stimuli in the bone–implant interface.
Applied Physics Letters | 2014
P. Santos; José Coutinho; V.J.B. Torres; Mark Rayson; P.R. Briddon
While the contamination of solar silicon by fast diffusing transition metals can be now limited through gettering, much attention has been drawn to the slow diffusing species, especially the early 3d and 4d elements. To some extent, hydrogen passivation has been successful in healing many deep centers, including transition metals in Si. Recent deep-level transient spectroscopy (DLTS) measurements concerning hydrogen passivation of Ti revealed the existence of at least four electrical levels related to TiiHn in the upper-half of the gap. These findings challenge the existing models regarding both the current level assignment as well as the structure/species involved in the defects. We revisit this problem by means of density functional calculations and find that progressive hydrogenation of interstitial Ti is thermodynamically stable in intrinsic and n-doped Si. Full passivation may not be possible to attain in p-type Si as TiiH3 and TiiH4 are metastable against dissociation and release of bond-centered pr...
Journal of Biomechanics | 2012
M. Soares dos Santos; Jorge Ferreira; José A. Simões; Auristela Ramos; Raul Morais dos Santos; Nuno M. Silva; Múcio Silva Reis; P. Santos
More than 80% of failures following Total Hip Arthroplasty (THR) procedures are due to implant loosening, which is strongly related with weak osseointegration. Current instrumented prostheses were designed to store only physiologic data [Damm, 2010; Heinlein, 2009]. The design of failure detection systems for hip implants is been performed [Marschner, 2009; Alpuim., 2008]. The current methodology to optimize such implants collects real-time data from the internal environment of the implant and uses the information for the research of new designs, materials and surgical techniques [Stansfield, 2003; Dayton, 2005]. However, proposals that ensure long-term implant survival have not been reported yet. This paper proposes a new methodology to avoid irreversible aseptic loosening, which may prevent to a certain extent revision surgical procedures. Through remotely controlled and monitored osteoblast mechanical micro-stimulation, real-time supervision of the osteointegration process may be ensured through tools for telemedicine.
biomedical engineering systems and technologies | 2012
Marco Soares dos Santos; Jorge Ferreira; A. Ramos; Ricardo Pascoal; Raul Morais dos Santos; Nuno M. Silva; José A. Simões; Múcio Silva Reis; António Festas; P. Santos
The development of smart orthopaedic implants is being considered as an effective solution to ensure their everlasting life span. The availability of electric power to supply active mechanisms of smart prostheses has remained a critical problem. This paper reports the first implementation of a new concept of energy harvesting systems applied to hip prostheses: the multi-source generation of electric energy. The reliability of the power supply mechanisms is strongly increased with the application of this new concept. Three vibration-based harvesters, operating in true parallel to harvest energy during human gait, were implemented on a Metabloc TM hip prosthesis to validate the concept. They were designed to use the angular movements on the flexion-extension, abduction-adduction and inward-outward rotation axes, over the femoral component, to generate electric power. The performance of each generator was tested for different amplitudes and frequencies of operation. Electric power up to 55 μJ/s was harvested. The overall function of smart hip prostheses can remain performing even if two of the generators get damaged. Furthermore, they are safe and autonomous throughout the life span of the implant.
Journal of Applied Physics | 2018
P. Santos; José Coutinho; Sven Öberg
Controlling the contamination of silicon materials by iron, especially dissolved interstitial iron (Fe
international conference on biomedical electronics and devices | 2017
P. Santos; Valentina Vassilenko; Fábio Vasconcelos; Flávio Gil
_{\mathrm{i}}
international conference on mobile and ubiquitous systems: networking and services | 2015
P. Santos; Susana Sargento; José Maria Fernandes
), is a longstanding problem with recent developments and several open issues. Among these we have the question whether hydrogen can assist iron diffusion, or if significant amounts of substitutional iron (Fe
Solid State Phenomena | 2015
A.G. Marinopoulos; P. Santos; João A. P. Coutinho
_{\mathrm{s}}
Sensors and Actuators A-physical | 2011
Raul Morais; Nuno M. Silva; P. Santos; Clara Frias; Jorge Ferreira; A. Ramos; José A. Simões; J. Baptista; Manuel J. C. S. Reis
) can be created. Using density functional calculations we explore the structure, formation energies, binding energies, migration, and electronic levels of several FeH complexes in Si. We find that a weakly bound Fe