Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where P.W. Wenham is active.

Publication


Featured researches published by P.W. Wenham.


European Journal of Vascular and Endovascular Surgery | 1998

Common iliac artery aneurysms in patients with abdominal aortic aneurysms

M. P. Armon; P.W. Wenham; Simon C. Whitaker; R.H.S. Gregson; Brian R. Hopkinson

OBJECTIVES To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. METHODS Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. RESULTS The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. CONCLUSIONS The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.


Journal of Vascular Surgery | 1997

Early results of endovascular aortic aneurysm surgery with aortouniiliac graft, contralateral iliac occlusion, and femorofemoral bypass

S.W. Yusuf; Simon C. Whitaker; Timothy A.M. Chuter; K. Ivancev; D. M. Baker; R.H.S. Gregson; William Tennant; P.W. Wenham; Brian R. Hopkinson

PURPOSE The aim of this study was to evaluate the feasibility of endovascular aortic aneurysm repair with use of an aortouniiliac graft secured with self-expanding (Gianturco) stents. METHODS Thirty patients with a median age of 72 years (age range, 52 to 86 years) and aneurysm diameter of 6.0 cm (range, 4.0 to 9.0 cm) were treated with an aortouniiliac endovascular graft. Of these 30 procedures, 28 were carried out electively and two as emergencies for leaking aneurysm. Of the 30 patients, 21 (70%) were considered to be at high risk for open surgery. A modified Gianturco stent, Dacron graft, and Wallstent were used for these procedures. RESULTS Endovascular repair was successfully carried out in 25 of 30 (83.3%) patients. All these patients were mobile and had resumed a normal diet within 48 hours of the procedure. The overall 30-day mortality rate was two in 30 (6.6%), but it was one in 28 (3.5%) for the elective cases; all deaths occurred in the group at high risk for surgery. Other complications encountered within 30 days of procedure included myocardial infarction in one patient, pneumonia in two patients, homonymous quadrantanopia in one patient, and colonic ischemia in one patient, giving an overall morbidity rate of four in 30 (13.3%). At a median follow-up of 4 months (range, 1 to 13 months), 27 of 30 (90%) patients remain alive and well. CONCLUSION Endovascular aortouniiliac repair of abdominal aortic aneurysm with Gianturco stent is feasible in both elective and emergency situations. It appears to be minimally traumatic, and the majority of patients deemed to be at high risk for open surgery can safely undergo endovascular repair. However, data on more patients with longer follow-up is required to determine its role in the management of abdominal aortic aneurysm.


The Lancet | 1994

Transfemoral endoluminal repair of abdominal aortic aneurysm with bifurcated graft

S.W. Yusuf; D. M. Baker; Simon C. Whitaker; P.W. Wenham; Brian R. Hopkinson; Timothy A.M. Chuter

Traditional open repair of abdominal aortic aneurysm has disadvantages. We present our experience of transfemoral endoluminal repair with a bifurcated graft system. 29 patients with aortic aneurysm over 5.5 cm in diameter and 1 with a 3.2 cm aneurysm and bilateral iliac stenosis were assessed; 5 were suitable for the procedure. The operation was successful in all the patients, without haemodynamic compromise or major complications. This technique has the potential to reduce morbidity and mortality from abdominal aortic aneurysm. Further modifications are required to make it applicable to most aneurysms.


Journal of Endovascular Therapy | 2003

Long-Term Renal Function following Endovascular Aneurysm Repair with Infrarenal and Suprarenal Aortic Stent-Grafts

Pierre Alric; Robert J. Hinchliffe; Marie-Christine Picot; Bruce Braithwaite; Shane T. MacSweeney; P.W. Wenham; Brian R. Hopkinson

Purpose: To determine in a retrospective analysis the incidence of renal impairment (RI) following endovascular repair (EVR) of abdominal aortic aneurysm (AAA), to assess the morbidity and mortality in endograft patients with preoperative RI, and to examine the impact of suprarenal stent-grafts on renal function. Methods: From March 1994 to October 2001, 315 AAA patients (289 men; mean age 72.4±7.0 years) undergoing EVR were entered prospectively into a vascular registry. The patients received either an in-house custom-made stent-graft or one of several commercially made devices implanted with infrarenal or suprarenal fixation. Renal function was monitored by serum creatinine measurements prior to discharge and at 3, 6, and 12 months and annually thereafter. Preoperative RI was defined as a serum creatinine > 130 μmol/L and/or long-term dialysis. Postoperative RI referred to a >20% increase in the serum creatinine over baseline. Additional deterioration of renal function in patients with preoperative RI was referred to as postoperatively worsened RI. Results: Of the 315 patients treated, 220 (69.8%) were considered high risk (ruptured AAA or ASA grade III or IV). Sixty-nine (21.9%) patients had preoperative RI (6 [1.9%] on preoperative dialysis). A suprarenal stent-graft was used in 169 (53.7%) patients and infrarenal stent-graft in the remaining 146 (46.3%). The mean follow-up was 30.1 ±22.7 months. Postoperative RI occurred in 53 (16.8%) patients (24 [7.6%] transient, 29 [9.2%] persistent). Patients with preoperative RI had a significantly higher incidence of postoperatively worsened RI (37.7% versus 11.0%, p<0.0001) and a higher mortality related to RI (7.2% versus 1.6%, p=0.02). Suprarenal fixation had no influence on the incidence of RI, on perioperative mortality, or on mortality related to RI. The only significant predictive factor of postoperative RI was preoperative RI (risk ratio 5.09, 95% CI 2.38 to 10.87, p=0.0001). Conclusions: Endovascular AAA repair may lead to persistent postoperative RI in nearly 10% of cases, especially in patients with preoperative RI. Suprarenal stent-graft fixation does not seem to have any deleterious effect on renal function. Further long-term studies are required to confirm the innocuous nature of transrenal stent placement.


Journal of Vascular Surgery | 2003

Durability of femorofemoral bypass grafting after aortouniiliac endovascular aneurysm repair

Robert J. Hinchliffe; Pierre Alric; P.W. Wenham; Brian R. Hopkinson

INTRODUCTION Endovascular aneurysm repair (EVAR) with aortouniiliac prostheses extends the morphologic range of aneurysms that can be treated and is potentially a more rapid and simple operation than bifurcated endovascular repair. It may, however, be limited by durability of the femorofemoral extra-anatomic bypass graft required to revascularize the contralateral lower limb. Previous studies of femorofemoral bypass grafts were performed almost exclusively in patients with occlusive disease. An 8-year single center experience with use of the femorofemoral bypass graft in aneurysmal disease is reported. METHODS All patients undergoing EVAR with an aortouniiliac endovascular stent graft over eight years (1994-2002) at a single institution were included in a retrospective study. Patient data were collected from a prospectively maintained local endovascular database. All patients gave informed consent and were part of an endovascular program approved by the local ethics committee. RESULTS Over the 8 years, 231 patients underwent EVAR with an aortouniiliac endovascular stent-graft. Median follow-up was 22 months. Localized wound complications were observed in 25 patients (11%). Cumulative 3-year patency rate for the femorofemoral bypass graft was 91%. At the end of 5 years 83% of grafts remained patent. CONCLUSIONS The femorofemoral bypass graft used during EVAR with aortouniliac stent grafts offers encouraging medium and long-term patency. When graft occlusion occurs, it is usually directly attributable to inadequate inflow from the endovascular stent graft itself or to endoluminal damage of the external iliac artery. Awareness and early detection of stent-graft distortion or complications in the external iliac artery may result in improved patency rates.


Journal of Endovascular Therapy | 1997

Influence of Abdominal Aortic Aneurysm Size on the Feasibility of Endovascular Repair

M. P. Armon; S. Waquar Yusuf; Simon C. Whitaker; R.H.S. Gregson; P.W. Wenham; Brian R. Hopkinson

PURPOSE To assess the effect of abdominal aortic aneurysm (AAA) size on overall aneurysm morphology with special attention to possible relationships among various anatomic variables that determine the feasibility of endovascular repair. METHODS One hundred sixty-eight patients were assessed with spiral computed tomographic angiography to measure the length and diameter of the AAA, the proximal neck, and the common iliac arteries. Anatomic variables were correlated with aneurysm size using Spearmans rank order correlation coefficients (rS); comparisons among small, intermediate, and large aneurysms were made using the Chi-square test. RESULTS Correlations between aneurysm size and the anatomic variables above were weak. The strongest association was between aneurysm size and aortic length (rS = 0.41, p < 0.001). Subgroup analysis showed no difference in proximal neck length, neck diameter, or overall suitability for endovascular repair between aneurysms greater or smaller than 5.5-cm diameter. However, significantly more short (< 1.5 cm), wide (> 3 cm), and hence, unsuitable proximal necks were found in patients with aneurysms > 7 cm in diameter (chi 2 = 7.8, p < 0.01). CONCLUSIONS Shortening and widening of the proximal neck seems to increase with aneurysm size but only after the aneurysm expands beyond 7 cm in diameter. Aneurysms with diameters in the 4.5- to 5.5-cm range are no more suitable for endovascular repair than those between 5.5 and 7 cm. The lack of any significant correlation between anatomic variables emphasizes the need for accurate preoperative assessment of the anatomy of each individual patient before endovascular repair.


Journal of Endovascular Therapy | 2002

The Zenith Aortic Stent-Graft: A 5-Year Single-Center Experience

Pierre Alric; Robert J. Hinchliffe; Shane T. MacSweeney; P.W. Wenham; Simon C. Whitaker; Brian R. Hopkinson

Purpose: To evaluate the efficacy and midterm results of the Zenith stent-graft in the treatment of abdominal aortic aneurysms (AAA). Methods: Since March 1994, 364 patients have undergone endovascular repair of infrarenal AAA. Of the 94 who were treated with the Zenith stent-graft from 1996 to 2002, 88 patients (82 men; mean age 72.6 ± 6.5 years, range 47–88) with at least 6-month follow-up were analyzed. Sixty-one (69.3%) patients were considered at high risk for intervention; 7 ruptured AAAs were treated emergently. In all, 68 (77.3%) bifurcated stent-grafts (including 18 TriFab systems) and 20 aortomonoiliac configurations were used. Cumulative data on endoleak, migration, secondary procedures, and survival were evaluated with Kaplan-Meier analyses. Results: Implantation success was 97.7%; 2 (2.3%) access-related failures were converted to open repair (1 immediate, 1 at 3 months). There were 3 (3.4%) graft limb thromboses (2 immediate, 1 late), 3 (3.4%) cases of colon ischemia due to embolization in 1 and hypogastric artery occlusion in 2, and 1 (1.1%) renal infarction due to embolism. Three (3.4%) patients died within 30 days. Eleven (12.5%) endoleaks and 1 (1.1%) late endograft migration were recorded. The 5-year cumulative endoleak and migration rates were 15% and 7%, respectively. Sixty-three (71.6%) patients did not present any complication related to the repair during a mean follow-up of 20.6 ± 14.9 months (range 6–68); notably, no complications were associated with the 18 TriFab systems. Six (6.8%) secondary procedures were performed (31% 5-year cumulative secondary procedural rate). All 6 (6.8%) aneurysm-related deaths (the 3 perioperative, 2 from late AAA rupture, and 1 during a secondary procedure) and 14 of 18 (20.4%) non-aneurysm—related deaths occurred in high-risk patients; the 5-year cumulative survival rates were 57% for any death and 92% for aneurysm-related deaths. Conclusions: The Zenith stent-graft appears both safe and effective in terms of midterm outcome of endovascular aortic aneurysm repair.


Journal of Vascular Surgery | 1998

Early complications of femorofemoral crossover bypass grafts after aorta uni-iliac endovascular repair of abdominal aortic aneurysms

S.R. Walker; Bruce Braithwaite; William Tennant; Shane T. MacSweeney; P.W. Wenham; Brian R. Hopkinson

OBJECTIVE The following procedures are the 3 main methods of endovascular repair (EVR) of abdominal aortic aneurysms (AAA): aorto-aortic bypass grafting, bifurcated bypass grafting, and aorta uni-iliac grafts. The latter method has the potential disadvantage of requiring an extra anatomic graft (ie, a femorofemoral crossover bypass graft) to maintain contralateral pelvic and limb perfusion. The aim of this study was to assess the complications associated with the femorofemoral crossover bypass graft after aorta uni-iliac EVR of AAA. METHOD A prospective review was conducted of the complications attributable to the femorofemoral crossover bypass graft in 136 patients who underwent EVR of AAA with an aorta uni-iliac device. RESULTS During a median follow-up of 7 months (range, 0 to 36 months), 4 patients had superficial wound infections that required antibiotic treatment and 2 patients had bypass graft infections. Nine hematomas developed: 7 (5%) groin hematomas (6 in patients with Dacron bypass grafts), 1 scrotal hematoma, and 1 perigraft hematoma. One bypass graft thrombus developed. CONCLUSION The femorofemoral crossover bypass graft is a safe and a durable component of EVR of AAA with an aorta uni-iliac device. The results are similar to those with bifurcated devices.


Journal of Endovascular Surgery | 1998

Spiral CT angiography versus aortography in the assessment of aortoiliac length in patients undergoing endovascular abdominal aortic aneurysm repair.

M. P. Armon; Simon C. Whitaker; R.H.S. Gregson; P.W. Wenham; Brian R. Hopkinson

Purpose: To compare measurements of aortoiliac length obtained with spiral computed tomographic angiography (CTA) and aortography in patients undergoing endovascular aneurysm repair. Methods: The distances from the lower-most renal artery to the aortic bifurcation and from the aortic bifurcation to the common iliac artery (CIA) bifurcation were measured using both CTA and aortography in 108 patients with abdominal aortic aneurysms. Results: The level of agreement between CTA and aortography was high, with 69% of aortic and 76% of iliac measurements within 1 cm and > 90% within 2 cm of each other. Mean differences were −0.35 ± 1.20 cm and 0.25 ± 1.10 cm, respectively, for aortic and iliac lengths. Aortography overestimated renal artery to aortic bifurcation length in comparison to CTA (p = 0.003), particularly in patients with large aneurysms (> 6.5 cm) and lumen diameters > 4.5 cm (p < 0.0001). Measurements of CIA length were shorter by aortography than CTA (p = 0.02). Conclusions: There is a high level of agreement between CTA and aortography in the measurement of aortoiliac length, but aortography overestimates renal artery to aortic bifurcation length in patients with large-diameter aneurysms and wide aneurysm lumens. CTA is sufficiently accurate in the majority of cases to be used as the sole basis for the construction of endovascular grafts.


European Journal of Vascular and Endovascular Surgery | 1997

The anatomy of abdominal aortic aneurysms: Implications for sizing of endovascular grafts

M. P. Armon; S.W. Yusuf; Simon C. Whitaker; R.H.S. Gregson; P.W. Wenham; Brian R. Hopkinson

OBJECTIVE To determine the full range of aorto-iliac anatomy of patients with abdominal aortic aneurysms (AAAs) and thence the range of endovascular graft sizes required to deal with the majority of AAAs. DESIGN Analysis of preoperative spiral CT measurements. MATERIALS One hundred and sixty-eight patients with AAAs. METHODS Multiplanar reconstruction measurements were taken of proximal aortic neck diameter and length, lowermost renal artery to the aortic bifurcation distance and length and diameter of common iliac arteries. Based on these measurements a range of graft sizes that would fit the majority of AAAs was determined. RESULTS Ranges of anatomical variables were as follows: proximal aortic neck diameter 18-30 mm, renal artery to aortic bifurcation distance 93-210 mm, common iliac artery length 13-108 mm, common iliac artery diameter 6-67 mm. Over 750 graft sizes would be required to cover all anatomical combinations using a one-piece aorto-uni-iliac graft. CONCLUSION A wide variety of aorto-iliac anatomy exists in patients with AAAs. The large number of graft sizes required to deal with the majority of AAAs makes the production of one-piece endovascular grafts commercially impractical. A proposed two-piece modular graft would allow the majority of AAAs to be treated using only 16 graft sizes.

Collaboration


Dive into the P.W. Wenham's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S.W. Yusuf

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar

R.H.S. Gregson

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar

G.S. Makin

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar

M. P. Armon

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

D. M. Baker

University of Nottingham

View shared research outputs
Researchain Logo
Decentralizing Knowledge