Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Panos Papaspyridakos is active.

Publication


Featured researches published by Panos Papaspyridakos.


Journal of Dental Research | 2012

Success Criteria in Implant Dentistry: A Systematic Review

Panos Papaspyridakos; Chun-Jung Chen; M. Singh; Hans-Peter Weber; German O. Gallucci

The purpose of this study was to examine the most frequently used criteria to define treatment success in implant dentistry. An electronic MEDLINE/PubMED search was conducted to identify randomized controlled trials and prospective studies reporting on outcomes of implant dentistry. Only studies conducted with roughened surface implants and at least five-year follow-up were included. Data were analyzed for success at the implant level, peri-implant soft tissue, prosthetics, and patient satisfaction. Most frequently reported criteria for success at the implant level were mobility, pain, radiolucency, and peri-implant bone loss (> 1.5 mm), and for success at the peri-implant soft-tissue level, suppuration, and bleeding. The criteria for success at the prosthetic level were the occurrence of technical complications/prosthetic maintenance, adequate function, and esthetics during the five-year period. The criteria at patient satisfaction level were discomfort and paresthesia, satisfaction with appearance, and ability to chew/taste. Success in implant dentistry should ideally evaluate a long-term primary outcome of an implant-prosthetic complex as a whole.


International Journal of Oral & Maxillofacial Implants | 2014

Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis.

Panos Papaspyridakos; Chun-Jung Chen; Sung-Kiang Chuang; Hans-Peter Weber

PURPOSE To report on the effect of immediate implant loading with fixed prostheses compared to early and conventional loading on implant and prosthesis survival, failure, and complications. MATERIALS AND METHODS An electronic and manual search was conducted to identify randomized controlled clinical trials (RCTs) as well as prospective and retrospective studies involving rough surface implants and implant fixed complete dental prostheses for edentulous patients. RESULTS The 62 studies that fulfilled the inclusion criteria featured 4 RCTs, 2 prospective case-control studies, 34 prospective cohort studies, and 22 retrospective cohort studies. These studies yielded data from 2,695 patients (2,757 edentulous arches) with 13,653 implants. Studies were grouped according to the loading protocol applied; 45 studies reported on immediate loading, 8 on early loading, and 11 on conventional loading. For the immediate loading protocol with flap surgery, the implant and prosthesis survival rates ranged from 90.1% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). When immediate loading was combined with guided flapless implant placement, the implant survival rates ranged from 90% to 99.4%. For the early loading protocol, the implant and prosthesis survival rates ranged from 94.74% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). For the conventional loading protocol, the implant and prosthesis survival rates ranged from 94.95% to 100% and 87.5% to 100%, respectively (range of follow-up, 2 to 15 years). No difference was identified between maxilla and mandible. CONCLUSIONS When selecting cases carefully and using dental implants with a rough surface, immediate loading with fixed prostheses in edentulous patients results in similar implant and prosthesis survival and failure rates as early and conventional loading. For immediate loading, most of the studies recommended a minimal insertion torque of 30 Ncm. The estimated 1-year implant survival was above 99% with all three loading protocols. Caution is necessary when interpreting these results, as there are many confounding factors that affect treatment outcomes with each of the loading protocols.


International Journal of Oral & Maxillofacial Implants | 2014

Consensus Statements and Clinical Recommendations for Implant Loading Protocols

German O. Gallucci; Goran I. Benic; Steven E. Eckert; Panos Papaspyridakos; Martin Schimmel; Alexander Schrott; Hans-Peter Weber

No abstract available.


International Journal of Oral & Maxillofacial Implants | 2014

Accuracy of implant impressions for partially and completely edentulous patients: a systematic review

Panos Papaspyridakos; Chun-Jung Chen; German O. Gallucci; Asterios Doukoudakis; Hans-Peter Weber; Vasileios Chronopoulos

PURPOSE To compare the accuracy of digital and conventional impression techniques for partially and completely edentulous patients and to determine the effect of different variables on the accuracy outcomes. MATERIALS AND METHODS An electronic and manual search was conducted to identify studies reporting on the accuracy of implant impressions. Pooled data were descriptively analyzed. Factors affecting the accuracy were identified, and their impact on accuracy outcomes was assessed. RESULTS The 76 studies that fulfilled the inclusion criteria featured 4 clinical studies and 72 in vitro studies. Studies were grouped according to edentulism; 41 reported on completely edentulous and 35 on partially edentulous patients. For completely edentulous patients, most in vitro studies and all three clinical studies demonstrated better accuracy with the splinted vs the nonsplinted technique (15 studies, splint; 1, nonsplint; 9, no difference). One clinical study and half of the in vitro studies reported better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 10, no difference). For partially edentulous patients, one clinical study and most in vitro studies showed better accuracy with the splinted vs the nonsplinted technique (8 studies, splint; 2, nonsplint; 3, no difference). The majority of in vitro studies showed better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 7, no difference), but the only clinical study reported no difference. CONCLUSION The splinted impression technique is more accurate for both partially and completely edentulous patients. The open-tray technique is more accurate than the closed-tray for completely edentulous patients, but for partially edentulous patients there seems to be no difference. The impression material (polyether or polyvinylsiloxane) has no effect on the accuracy. The implant angulation affects the accuracy of implant impressions, while there are insufficient studies for the effect of implant connection type. Further accuracy studies are needed regarding digital implant impressions.


Clinical Oral Implants Research | 2016

Digital versus conventional implant impressions for edentulous patients: accuracy outcomes

Panos Papaspyridakos; German O. Gallucci; Chun-Jung Chen; Stijn Hanssen; Ignace Naert; Bart Vandenberghe

PURPOSE To compare the accuracy of digital and conventional impression techniques for completely edentulous patients and to determine the effect of different variables on the accuracy outcomes. MATERIALS AND METHODS A stone cast of an edentulous mandible with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level impressions. Digital impressions (n = 10) were taken with an intraoral optical scanner (TRIOS, 3shape, Denmark) after connecting polymer scan bodies. For the conventional polyether impressions of the master cast, a splinted and a non-splinted technique were used for implant-level and abutment-level impressions (4 cast groups, n = 10 each). Master casts and conventional impression casts were digitized with an extraoral high-resolution scanner (IScan D103i, Imetric, Courgenay, Switzerland) to obtain digital volumes. Standard tessellation language (STL) datasets from the five groups of digital and conventional impressions were superimposed with the STL dataset from the master cast to assess the 3D (global) deviations. To compare the master cast with digital and conventional impressions at the implant level, analysis of variance (ANOVA) and Scheffes post hoc test was used, while Wilcoxons rank-sum test was used for testing the difference between abutment-level conventional impressions. RESULTS Significant 3D deviations (P < 0.001) were found between Group II (non-splinted, implant level) and control. No significant differences were found between Groups I (splinted, implant level), III (digital, implant level), IV (splinted, abutment level), and V (non-splinted, abutment level) compared with the control. Implant angulation up to 15° did not affect the 3D accuracy of implant impressions (P > 0.001). CONCLUSION Digital implant impressions are as accurate as conventional implant impressions. The splinted, implant-level impression technique is more accurate than the non-splinted one for completely edentulous patients, whereas there was no difference in the accuracy at the abutment level. The implant angulation up to 15° did not affect the accuracy of implant impressions.


Clinical Implant Dentistry and Related Research | 2014

Implant and Prosthodontic Survival Rates with Implant Fixed Complete Dental Prostheses in the Edentulous Mandible after at Least 5 Years: A Systematic Review

Panos Papaspyridakos; Muizzaddin Mokti; Chun-Jung Chen; Goran I. Benic; German O. Gallucci; Vasileios Chronopoulos

BACKGROUND The treatment of mandibular edentulism with implant fixed complete dental prostheses (IFCDPs) is a routinely used treatment option. PURPOSE The study aims to report the implant and prosthodontic survival rates associated with IFCDPs for the edentulous mandible after an observation period of a minimum 5 years. MATERIALS AND METHODS An electronic MEDLINE/PubMED search was conducted to identify randomized controlled clinical trials and prospective studies with IFCDPs for the edentulous mandible. Clinical studies with at least 5-year follow-up were selected. Pooled data were statistically analyzed and cumulative implant- and prosthesis survival rates were calculated by meta-analysis, regression, and chi-square statistics. Implant-related and prosthesis-related factors were identified and their impact on survival rates was assessed. RESULTS Seventeen prospective studies, including 501 patients and 2,827 implants, were selected for meta-analysis. The majority of the implants (88.5% of all placed implants) had been placed in the interforaminal area. Cumulative implant survival rates for rough surface ranged from 98.42% (95% confidence interval [CI]: 97.98-98.86) (5 years) to 96.86% (95% CI: 96.00-97.73) (10 years); smooth surface implant survival rates ranged from 98.93% (95% CI: 98.38-99.49) (5 years) to 97.88% (95% CI: 96.78-98.98) (10 years). The prosthodontic survival rates for 1-piece IFCDPs ranged from 98.61% (95% CI: 97.80-99.43) (5 years) to 97.25% (95% CI: 95.66-98.86) (10 years). CONCLUSION Treatment with mandibular IFCDPs yields high implant and prosthodontic survival rates (more than 96% after 10 years). Rough surface implants exhibited cumulative survival rates similar to the smooth surface ones (p > .05) in the edentulous mandible. The number of supporting implants and the antero-posterior implant distribution had no influence (p > .05) on the implant survival rate. The prosthetic design and veneering material, the retention type, and the loading protocol (delayed, early, and immediate) had no influence (p > .05) on the prosthodontic survival rates.


Journal of Prosthetic Dentistry | 2012

Flapless CAD/CAM-guided surgery for staged transition from failing dentition to complete arch implant rehabilitation: a 3-year clinical report.

Panos Papaspyridakos; George Shelby White; Kunal Lal

The transition of patients from failing dentition to complete arch implant rehabilitation often requires that the patient be rendered edentulous and has to wear a complete removable dental prosthesis for varying periods of time. This is objectionable to many patients. A staged treatment approach allows a fixed interim restoration, patient comfort, and prosthodontic control throughout the rehabilitation process. CAD/CAM-guided flapless implant surgery has the advantage of prosthetically driven implant placement and minimal postoperative sequelae. A patient with a failing dentition was treated with this combined protocol and was followed up for 3 years after loading. Implant and prosthesis survival rates were 100%, with no technical complications encountered up to the last recall. The purpose of this clinical report is to describe a combination of CAD/CAM-guided flapless surgery and a staged treatment approach, thereby giving the patient a tooth-supported or implant-supported fixed interim prosthesis during the entire rehabilitation process. The various surgical, laboratory, and prosthetic stages are illustrated for the complete arch prosthetic rehabilitation, and the 3-year follow-up outcome is reported.


Journal of Esthetic and Restorative Dentistry | 2010

Immediate Loading of the Maxilla with Prefabricated Interim Prosthesis Using Interactive Planning Software, and CAD/CAM Rehabilitation with Definitive Zirconia Prosthesis: 2‐Year Clinical Follow‐up

Panos Papaspyridakos; Kunal Lal

UNLABELLED Immediate loading in implant dentistry has provided several advantages for both patients and clinicians. Recent advances in computer-aided design/computer-aided manufacturing (CAD/CAM) technology, medical imaging and rapid prototyping have added to the armamentarium of implant dentistry in terms of efficiency, accuracy and predictability. Rapid prototyping and CAD/CAM technology are used to fabricate stereolithographic surgical templates for flapless implant placement. In addition to that, this technology is also used for the fabrication of zirconia frameworks. The zirconia-based implant restorations are gaining popularity in implant prosthodontics combining esthetic properties with strength and biocompatibility. The purpose of this article is to illustrate the steps for implant rehabilitation of the edentulous maxilla with zirconia prosthesis and report the 2-year clinical follow-up of novel technological advances in surgical placement, provisionalization and fabrication of a definitive restoration. CLINICAL SIGNIFICANCE A comprehensive approach to full mouth implant rehabilitation using cutting edge technology is illustrated in a simplified manner.


International Journal of Prosthodontics | 2013

Effect of misfit of cement-retained implant single crowns on crestal bone changes.

Chun-Jung Chen; Panos Papaspyridakos; Kevin Guze; Medha Singh; Hans-Peter Weber; German O. Gallucci

The purpose of this clinical study was to compare peri-implant crestal bone levels between misfitting (overhanging/open margin) cement-retained implant single crowns (SCs) vs accurately fitted implant SCs. Seventeen subjects were divided into two groups: test group (misfitting crowns, n = 10) and control group (accurately fitted crowns, n = 7). Crestal bone level changes were assessed using digital software. The average differences in mean bone loss within and between the two groups were statistically significant. Cement-retained implant SCs with marginal misfit resulted in more crestal bone loss than accurately fitted crowns after a mean of 3 years in function.


Journal of Esthetic and Restorative Dentistry | 2017

Digital Workflow for Fixed Implant Rehabilitation of an Extremely Atrophic Edentulous Mandible in Three Appointments

Panos Papaspyridakos; Neha Rajput; Yukio Kudara; Hans-Peter Weber

OBJECTIVE To present a rationale to reduce treatment complexity, number of surgeries, and overall treatment time for patients with extreme mandibular ridge deficiency. CLINICAL CONSIDERATIONS A 67-year-old fully edentulous male presented with a chief complaint of poor retention and stability of the mandibular complete denture with consequent discomfort and inability to chew. A novel 3-appointment protocol from guided implant placement to definitive prosthesis delivery was implemented. At the first appointment, a guided surgery protocol with the All-on-4 concept was used in the mandible. Implant placement was followed by immediate loading with a fixed provisional prosthesis providing the patient with immediate function. Final impression, cast verification and articulation, determination of VDO, and interocclusal records were obtained in the same appointment. In the second appointment, the framework try-in was performed and a pick-up impression was taken after a new CR record. The third appointment included the delivery of the final screw-retained, one-piece, full-arch prosthesis opposed by a maxillary complete denture. CONCLUSION This expedited protocol allows for implant placement with a surgical template generated from preoperative virtual planning of the implants and the CAD/CAM prosthodontic rehabilitation using a digital workflow. The patient was satisfied with the esthetic and functional outcome and was enrolled into a 6-month recall program. CLINICAL SIGNIFICANCE This article describes an expedited protocol illustrating a digital workflow for full arch implant rehabilitation of the extremely atrophic mandible. Flapless implant placement with a surgical template generated from virtual planning was followed by immediate loading with a fixed prosthesis. Digital impression/digitization of the working cast and CAD/CAM technology were used to mill the definitive prosthesis. From guided surgery to the definitive rehabilitation only three appointments were necessary. This digital workflow can enhance patient acceptance and comfort and serve as an alternative treatment in the indicated clinical scenario. (J Esthet Restor Dent 29:178-188, 2017).

Collaboration


Dive into the Panos Papaspyridakos's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carlo Ercoli

University of Rochester

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge