Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Patrick Donzeau-Gouge is active.

Publication


Featured researches published by Patrick Donzeau-Gouge.


The New England Journal of Medicine | 2012

Registry of transcatheter aortic-valve implantation in high-risk patients

Martine Gilard; Hélène Eltchaninoff; Bernard Iung; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lievre; Alain Prat; Emmanuel Teiger; Thierry Lefèvre; Dominique Himbert; Didier Tchetche; Didier Carrié; Bernard Albat; Alain Cribier; Gilles Rioufol; Arnaud Sudre; Didier Blanchard; Frederic Collet; Pierre Dos Santos; Nicolas Meneveau; Ashok Tirouvanziam; Christophe Caussin; Philippe Guyon; Jacques Boschat; Frédéric Collart; Remi Houel; Stephane Delpine

BACKGROUND Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).


European Heart Journal | 2011

Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry

Hélène Eltchaninoff; Alain Prat; Martine Gilard; Alain Leguerrier; Didier Blanchard; Gerard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Pascal Gueret

AIMS Transcatheter aortic valve implantation is a therapeutic alternative for high-surgical-risk patients with severe symptomatic aortic stenosis. Two models of prosthesis are currently commercialized in France, which can be implanted either via a transarterial or a transapical approach. The aim of the study was to evaluate in a national French registry the early safety and efficacy of transcatheter aortic valve replacement (AVR) using either the Edwards SAPIEN™ or CoreValve™ in high-surgical-risk patients with severe aortic stenosis. METHODS AND RESULTS The multicentre national registry was conducted in 16 centres between February 2009 and June 2009, under the authority of the French Societies of Cardiology and Thoracic and Cardio-Vascular Surgery. The primary endpoint was mortality at 1 month. Two hundred and forty-four high-surgical-risk patients (logistic EuroSCORE ≥20%, STS ≥10%, or contra-indication to AVR) were enrolled. Mean age was 82 ± 7 years and 43.9% were female. Edwards SAPIEN and CoreValve were implanted in 68 and 32% of patients, respectively. The approaches used were transarterial (transfemoral: 66%; subclavian: 5%) or transapical in 29%. Device success rate was 98.3% and 30-day mortality was 12.7%. Severe complications included stroke (3.6%), tamponade (2%), acute coronary occlusion (1.2%), and vascular complications (7.3%). Pacemaker was required in 11.8%. At 1 month, 88% of patients were in NYHA class II or less. CONCLUSION This prospective registry reflects the real-life experience of transcatheter aortic valve implantation in high-risk elderly patients in France. The early results are satisfactory in terms of feasibility, short-term haemodynamic and functional improvement, and safety. Longer term follow-up will be further assessed.


Jacc-cardiovascular Interventions | 2011

Transfemoral aortic valve implantation new criteria to predict vascular complications.

Kentaro Hayashida; Thierry Lefèvre; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Darren Mylotte; Jhonathan Uribe; Arnaud Farge; Patrick Donzeau-Gouge; Erik Bouvier; Bertrand Cormier; Marie-Claude Morice

OBJECTIVES This study sought to evaluate the incidence, impact, and predictors of vascular complications in transcatheter aortic valve implantation (TAVI). BACKGROUND Vascular complications increase morbidity and mortality in transfemoral TAVI; however, there remains a paucity of data describing these serious events. METHODS We performed a prospective cohort study of 130 consecutive transfemoral TAVI recipients. Vascular complications were defined by the Valve Academic Research Consortium (VARC) criteria. The ratio of the sheath outer diameter (in millimeters) to the minimal femoral artery diameter (in millimeters) defined the sheath to femoral artery ratio (SFAR). RESULTS In our cohort of elderly patients (83.3 ± 5.9 years), the logistic EuroScore was 25.8% ± 11.9%. The Edwards valve was used in 102 cases (18- to 24-F) and the CoreValve in 27 (18-F). The minimal femoral artery diameter was 8.17 ± 1.14 mm, and the calcification (0 to 3) and tortuosity scores (0 to 3) were 0.58 ± 0.72 and 0.28 ± 0.53, respectively. The mean sheath diameter was 8.10 ± 0.82 mm, and the mean SFAR was 0.99 ± 0.16. Vascular complications occurred in 27.6% (VARC major: 17.3%, minor: 10.2%), and major vascular complications predicted 30-day mortality (22.7% vs. 7.6%, p = 0.049). The SFAR (hazard ratio [HR]: 186.20, 95% confidence interval [CI]: 4.41 to 7,855.11), center experience (HR: 3.66, 95% CI: 1.17 to 11.49), and femoral calcification (HR: 3.44, 95% CI: 1.16 to 10.17) predicted major complications by multivariate analysis. An SFAR threshold of 1.05 (area under the curve = 0.727) predicted a higher rate of VARC major complications (30.9% vs. 6.9%, p = 0.001) and 30-day mortality (18.2% vs. 4.2%, p = 0.016). CONCLUSIONS Vascular complications in transfemoral TAVI are relatively frequent. VARC major vascular complications increase 30-day mortality and are predicted by experience, femoral calcification, and SFAR. Routine application of SFAR will improve patient selection for transfemoral TAVI and may improve outcome.


The Journal of Physiology | 2001

Cyclic GMP regulation of the L-type Ca2+ channel current in human atrial myocytes

Grégoire Vandecasteele; Ignacio Verde; Catherine Rücker-Martin; Patrick Donzeau-Gouge; Rodolphe Fischmeister

The regulation of the L‐type Ca2+ current (ICa) by intracellular cGMP was investigated in human atrial myocytes using the whole‐cell patch‐clamp technique. Intracellular application of 0.5 μm cGMP produced a strong stimulation of basal ICa (+64 ± 5%, n= 60), whereas a 10‐fold higher cGMP concentration induced a 2‐fold smaller increase (+36 ± 8%, n= 35). The biphasic response of ICa to cGMP was not mimicked by the cGMP‐dependent protein kinase (PKG) activator 8‐bromoguanosine 3′,5′ cyclic monophosphate (8‐bromo‐cGMP, 0.5 or 5 μm), and was not affected by the PKG inhibitor KT 5823 (100 nm). In contrast, cGMP stimulation of ICa was abolished by intracellular perfusion with PKI (10 μm), a selective inhibitor of the cAMP‐dependent protein kinase (PKA). Selective inhibition of the cGMP‐inhibited phosphodiesterase (PDE3) by extracellular cilostamide (100 nm) strongly enhanced basal ICa in control conditions (+78 ± 13%, n= 7) but had only a marginal effect in the presence of intracellular cGMP (+22 ± 7% in addition to 0.5 μm cGMP, n= 11; +20 ± 22% in addition to 5 μm cGMP, n= 7). Application of erythro‐9‐[2‐hydroxy‐3‐nonyl]adenine (EHNA, 30 μm), a selective inhibitor of the cGMP‐stimulated phosphodiesterase (PDE2), fully reversed the secondary inhibitory effect of 5 μm cGMP on ICa (+99 ± 16% stimulation, n= 7). Altogether, these data indicate that intracellular cGMP regulates basal ICa in human atrial myocytes in a similar manner to NO donors. The effect of cGMP involves modulation of the cAMP level and PKA activity via opposite actions of the nucleotide on PDE2 and PDE3.


Journal of the American College of Cardiology | 2012

Sex-related differences in clinical presentation and outcome of transcatheter aortic valve implantation for severe aortic stenosis.

Kentaro Hayashida; Marie-Claude Morice; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Arnaud Farge; Patrick Donzeau-Gouge; Erik Bouvier; Bertrand Cormier; Thierry Lefèvre

OBJECTIVES The purpose of this study was to clarify the impact of sex-related differences in transcatheter aortic valve implantation (TAVI) for high-risk patients with severe aortic stenosis. BACKGROUND Although TAVI is becoming a mature technique, the impact of sex differences remains unclear. METHODS The TAVI patients were included prospectively in a dedicated database from October 2006. The proportion of women (n = 131) was similar to that of men (n = 129). The Edwards valve (85.4%) and CoreValve (14.6%) were used through the transfemoral (65.0%), subclavian (3.1%), or transapical (31.9%) approach. All events were defined according to Valve Academic Research Consortium criteria. RESULTS Age was similar (83.1 ± 6.3 years), but women had less coronary and peripheral disease, less previous cardiac surgery, higher ejection fraction, and lower EuroSCORE (European System for Cardiac Operative Risk Evaluation [22.3 ± 9.0% vs. 26.2 ± 13.0%, p = 0.005]). Minimal femoral size (7.74 ± 1.03 mm vs. 8.55 ± 1.34 mm, p < 0.001), annulus size (20.9 ± 1.4 vs. 22.9 ± 1.7 mm, p < 0.001), and valve size (23.9 ± 1.6 mm vs. 26.3 ± 1.5 mm, p < 0.001) were smaller in women. Device success was similar (90.8% vs. 88.4%, p = 0.516) despite more frequent iliac complications (9.0% vs. 2.5%, p = 0.030). Residual mean aortic pressure gradient (11.6 ± 4.9 vs. 10.9 ± 4.9, p = 0.279) was also similar. The 1-year survival rate was higher for women, 76% (95% confidence interval: 72% to 80%), than for men, 65% (95% confidence interval: 60% to 69%); and male sex (hazard ratio: 1.62, 95% confidence interval: 1.03 to 2.53, p = 0.037) was identified as a predictor of midterm mortality by Cox regression analysis. CONCLUSIONS Female sex is associated with better baseline clinical characteristics and improved survival, and is identified as a predictor of midterm survival after TAVI.


Jacc-cardiovascular Interventions | 2012

Impact of post-procedural aortic regurgitation on mortality after transcatheter aortic valve implantation

Kentaro Hayashida; Thierry Lefèvre; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Erik Bouvier; Arnaud Farge; Patrick Donzeau-Gouge; Bertrand Cormier; Marie Claude Morice

OBJECTIVES The goal of the study was to clarify the impact of post-procedural aortic regurgitation (post-AR) grade 2/4 on clinical outcomes. BACKGROUND Post-AR >2/4 is known to be associated with poor short- to midterm outcome after transcatheter aortic valve implantation (TAVI). METHODS We compared clinical outcomes in 400 consecutive TAVI recipients according to post-AR grade: grade 0 or 1 (group 1 = 74.8%), grade 2 (group 2 = 22.2%), or grade 3 or 4 (group 3 = 3.0%). RESULTS The mean age was similar in the 3 groups (83.4 ± 6.1 years) as was the logistic EuroSCORE (22.5 ± 11.4%, 24.5 ± 11.6%, and 21.5 ± 9.4%, p = 0.28) and annulus size (22.0 ± 1.8, 22.2 ± 2.1, and 22.5 ± 2.1 mm, p = 0.53). The Edwards valve was most frequently used in group 1 compared with groups 2 and 3 (89.3%, 78.7%, and 83.3%, p = 0.03), and the implanted valve size was similar in all groups (25.6 ± 2.0, 25.4 ± 2.2, and 25.5 ± 2.2 mm, respectively, p = 0.69). Post-dilation was required more frequently in group 3 (4.7%, 24.1%, and 50.0%, respectively, p < 0.01). Post-procedural increase in mitral regurgitation was in line with the post-AR grade (0.78 ± 0.73, 1.22 ± 0.80, and 1.89 ± 0.78, respectively, p < 0.01). Despite the absence of difference in 30-day mortality, longer-term outcome was significantly poorer in patients with AR grade 2 than in those with AR grade 0 or 1 (log-rank p < 0.01), albeit better than in patients with AR grade 3 or 4 (p = 0.04), regardless of TAVI type and left ventricular function. Post-AR ≥2/4 was also identified as an independent predictor of mid- to long-term mortality (hazard ratio: 1.68, 95% confidence interval: 1.21 to 1.44, p < 0.01). CONCLUSIONS Post-AR grade 2/4 after TAVI is associated with worse outcome compared with grade 0 or 1. Careful valve selection and post-dilation when required to avoid post-AR grade 2 may contribute to improved clinical outcome after TAVI.


Circulation | 2014

Postprocedural Aortic Regurgitation in Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Replacement Procedures Analysis of Predictors and Impact on Long-Term Mortality: Insights From the FRANCE2 Registry

Eric Van Belle; Francis Juthier; Sophie Susen; André Vincentelli; Bernard Iung; Jean Dallongeville; Hélène Eltchaninoff; Marc Laskar; Pascal Leprince; Michel Lievre; Carlo Banfi; Jean-Luc Auffray; Cedric Delhaye; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Alain Leguerrier; Alain Prat; Martine Gilard; Emmanuel Teiger

Background— Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results— TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P=0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery (P=0.04), larger aortic annulus (P=0.0004), and smaller prosthesis diameter (P=0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery(P=0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P=0.0001) and SE-TAVR (hazard ratio=2.11; P=0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions— Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.Background— Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results— TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions— Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2. # CLINICAL PERSPECTIVE {#article-title-26}


Heart | 2014

Predictive factors of early mortality after transcatheter aortic valve implantation: individual risk assessment using a simple score

Bernard Iung; Cédric Laouénan; Dominique Himbert; Hélène Eltchaninoff; Karine Chevreul; Patrick Donzeau-Gouge; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lievre; Alain Prat; Emmanuel Teiger; Marc Laskar; Alec Vahanian; Martine Gilard

Objective Decision making for intervention in symptomatic aortic stenosis should balance the risks of surgery and of transcatheter aortic valve implantation (TAVI). We identified the factors associated with early mortality after TAVI and aimed to develop and validate a simple risk score. Methods A population of 3833 consecutive patients was randomly split into two cohorts comprising 2552 and 1281 patients, used respectively to develop and validate a scoring system predicting 30-day or in-hospital mortality. Results TAVI was performed using the Edwards Sapien prosthesis in 2551 (66.8%) patients and the Medtronic Corevalve in 1270 (33.2%). Approach was transfemoral in 2801 (73.4%) patients, transapical in 678 (17.8%), subclavian in 219 (5.7%) and other in 117 (3.1%). Early mortality was 10.0% (382 patients). A multivariate logistic model identified the following predictive factors of early mortality: age ≥90 years, body mass index <30 Kg/m2, New York Heart Association class IV, pulmonary hypertension, critical haemodynamic state, ≥2 pulmonary oedemas during the last year, respiratory insufficiency, dialysis and transapical or other (transaortic and transcarotid) approaches. A 21-point predictive score was derived. C-index was 0.67 for the score in the development cohort and 0.59 in the validation cohort. There was a good concordance between predicted and observed 30-day mortality rates in the development and validation cohorts. Conclusions Early mortality after TAVI is mainly related to age, the severity of symptoms, comorbidities and transapical approach. A simple score can be used to predict early mortality after TAVI. The moderate discrimination is however a limitation for the accurate identification of high-risk patients.


Circulation-cardiovascular Interventions | 2013

Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis

Kentaro Hayashida; Erik Bouvier; Thierry Lefèvre; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Yusuke Watanabe; Arnaud Farge; Patrick Donzeau-Gouge; Bertrand Cormier; Marie Claude Morice

Background—Bicuspid aortic valve (BAV) is regarded as a relative contraindication to transcatheter aortic valve implantation attributable to the risk of uneven expansion of the bioprosthesis. The purpose of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation in patients with BAV. Methods and Results—Of 470 patients included in our prospective transcatheter aortic valve implantation database (October 2006–January 2012), 229 consecutive patients undergoing both echocardiography and multidetector computed tomography were analyzed. We compared clinical outcomes in patients with vs patients without BAV. In this series of 229 patients, BAV was detected by multidetector computed tomography in 21 patients (9.2%). BAV was identified by transthoracic and transoesophagal echocardiography in only 9 of these 21 patients. Patients were 83.1±6.6 years old, and European system for cardiac operative risk evaluation score was 20.0%±11.4%. The BAV group was similar to the non-BAV group except for diabetes mellitus (4.8% vs 24.0%; P=0.05). The aortic annulus diameter in BAV patients was not significantly larger by multidetector computed tomography (24.7±3.0 vs 23.7±1.9 mm; P=0.07). The CoreValve was used more frequently in the BAV group (47.6% vs 16.3%; P=0.002). There was no significant difference in device success (100% vs 92.8%; P=0.37), risk of annulus rupture (0% vs 1.4%; P=1.00), or valve migration (0% vs 1.4%; P=1.00) in BAV patients compared with non-BAV patients. Postprocedural mean gradient (10.0±3.4 vs 9.7±4.1 mm Hg; P=0.58), aortic regurgitation ≥2 of 4 (19.0% vs 14.9%; P=0.54), 30-day mortality (4.8% vs 8.2%; P=1.00), and 30-day combined safety end point (14.3% vs 13.5%; P=1.00) were also similar in both groups. Conclusions—In selected BAV patients, transcatheter aortic valve implantation may be associated with low complication rate, efficacy, and acceptable outcomes similar to those in non-BAV patients.


Circulation-cardiovascular Interventions | 2014

Clinical Outcomes and Safety of Transfemoral Aortic Valve Implantation Under General Versus Local Anesthesia Subanalysis of the French Aortic National CoreValve and Edwards 2 Registry

Atsushi Oguri; Masanori Yamamoto; Gauthier Mouillet; Martine Gilard; Marc Laskar; Hélène Eltchaninoff; Jean Fajadet; Bernard Iung; Patrick Donzeau-Gouge; Pascal Leprince; Alain Leguerrier; Alain Prat; Michel Lievre; Karine Chevreul; Jean-Luc Dubois-Randé; Romain Chopard; Eric Van Belle; Toshiaki Otsuka; Emmanuel Teiger

Background—Transcatheter aortic valve implantation (TAVI) performed under local anesthesia (LA) is becoming increasingly common. We aimed to compare the clinical outcomes in patients who underwent transfemoral-TAVI under general anesthesia (GA) and LA. Methods and Results—Data from 2326 patients in the French Aortic National CoreValve and Edwards 2 (FRANCE 2) registry who underwent transfemoral-TAVI were analyzed. During the study period, the percentage of LA procedures increased gradually from 14% in January 2010 to 59% in October 2011. The clinical outcomes for GA (n=1377) and LA (n=949) were compared. Numerous baseline characteristics differed between the 2 groups, and the use of transesophageal echocardiographic guidance was more common in GA than in LA (76.3% versus 16.9%; P<0.001). Device success and cumulative 30-day survival rates were similar in the 2 groups (97.6% versus 97.0%; P=0.41 and 91.6% versus 91.3%; P=0.69, respectively), whereas the incidence of postprocedural aortic regurgitation≥mild was significantly lower in GA than in LA (15.0% versus 19.1%; P=0.015). The groups were also analyzed using a propensity-matching model, including transesophageal echocardiographic usage (GA [n=401] versus LA [n=401]). This model indicated that there were no significant differences between the 2 groups in the rates of 30-day survival (GA [91.4%] versus LA [89.3%]; P=0.27] and postprocedural aortic regurgitation≥mild (GA [12.7%] versus LA [16.2%]; P=0.19). Conclusions—The less invasive transfemoral-TAVI under LA is preferred in clinical settings and seems to be acceptable; however, the higher incidence of postprocedural aortic regurgitation is emphasized. Therapeutic efforts should be made to reduce such complications during transfemoral-TAVI under LA.

Collaboration


Dive into the Patrick Donzeau-Gouge's collaboration.

Top Co-Authors

Avatar

Thierry Lefèvre

Cardiovascular Institute of the South

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Erik Bouvier

Cardiovascular Institute of the South

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jean Fajadet

Charles University in Prague

View shared research outputs
Top Co-Authors

Avatar

Bernard Chevalier

Erasmus University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Thomas Hovasse

Guy's and St Thomas' NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge