Paula C.A.G. Pinto
University of Porto
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Paula C.A.G. Pinto.
Analytica Chimica Acta | 2011
Cristina I.C. Silvestre; Paula C.A.G. Pinto; Marcela A. Segundo; M. Lúcia M.F.S. Saraiva; José L. F. C. Lima
Sequential injection analysis systems have been extensively exploited in the last decades for the implementation of enzyme based assays aiming the evaluation of enzyme activity or the determination of specific analytes. The most prominent aspects of the automation of enzymatic assays in these systems are discussed in this review. Special attention is devoted to the mode of enzyme manipulation in homogeneous or heterogeneous media and to the comparison with batch and flow injection enzyme methodologies. The possibility of implementing strategies for the enhancement of selectivity in specific determinations is also addressed. The more recent trends in this field are discussed focusing mainly on the miniaturization resorting to the lab-on valve platform as well as on the bead injection concept.
Ecotoxicology and Environmental Safety | 2012
Paula C.A.G. Pinto; Susana P.F. Costa; José L. F. C. Lima; M. Lúcia M.F.S. Saraiva
An automated high-throughput Vibrio fischeri assay was developed and further applied to the evaluation of ionic liquids (ILs) (eco)toxicity. The assay was based on the reduction of bacterial bioluminescence in the presence of test compounds and the results were presented as EC(50). The assays were performed with eight commercially available ILs with distinct cationic head groups, alkyl side chains and anions. EC(50) values between 6.5 and 691.9 mmol L(-1) were obtained for the tested ILs, being hmim [Cl] the most toxic and bmim [Cl] the less toxic ones, confirming the influence of the different structural elements. Moreover, all the tested ILs exhibited a (eco)toxicity lower than Cu(II), used as a positive control during the optimization and analysis steps. The automated assay assured the precise control of the contact time between V. fischeri and test compound by means of a simple protocol that guaranteed adequate aspiration and handling of the solutions as well as the precise implementation of a computer controlled stop period. Furthermore, a significant reduction of the assay costs was achieved through automation mainly by a drastic reduction of the volume of bacterial suspension and test compound. The methodology was validated by comparison with a microplate assay; it was stated that the results, obtained after a 3min contact time, changed proportionally relatively to Cu(II) in both assays. This confirmed the applicability of the methodology as an (eco)toxicity screening assay, with reduction of time and increase of robustness and repeatability (n=10; rsd<1.1%). It is expected that due to its simplicity and reduced cost the developed assay can be integrated in the early stage of development of new compounds as a rapid screening test.
Journal of Hazardous Materials | 2015
Susana P.F. Costa; Paula C.A.G. Pinto; Rui A. S. Lapa; M. Lúcia M.F.S. Saraiva
A fully automated Vibrio fischeri methodology based on sequential injection analysis (SIA) has been developed. The methodology was based on the aspiration of 75 μL of bacteria and 50 μL of inhibitor followed by measurement of the luminescence of bacteria. The assays were conducted for contact times of 5, 15, and 30 min, by means of three mixing chambers that ensured adequate mixing conditions. The optimized methodology provided a precise control of the reaction conditions which is an asset for the analysis of a large number of samples. The developed methodology was applied to the evaluation of the impact of a set of ionic liquids (ILs) on V. fischeri and the results were compared with those provided by a conventional assay kit (Biotox(®)). The collected data evidenced the influence of different cation head groups and anion moieties on the toxicity of ILs. Generally, aromatic cations and fluorine-containing anions displayed higher impact on V. fischeri, evidenced by lower EC50. The proposed methodology was validated through statistical analysis which demonstrated a strong positive correlation (P>0.98) between assays. It is expected that the automated methodology can be tested for more classes of compounds and used as alternative to microplate based V. fischeri assay kits.
New Journal of Chemistry | 2013
Paula C.A.G. Pinto; Diogo Ribeiro; Ana Azevedo; Vanessa Dela Justina; Edite Cunha; Katharina Bica; Maria Vasiloiu; M. Lúcia M.F.S. Saraiva
This work is based on the evaluation of the protein binding affinity, partition coefficients (with a biomimetic membrane) and surfactant properties of three pharmaceutically active ionic liquids based on the salicylate anion. Fluorescence spectroscopy was used for the evaluation of the binding of ionic liquids to human serum albumin and for the determination of critical micelle concentrations. Partition coefficients were determined using micelles of hexadecylphosphocholine and UV-Vis derivative spectroscopy. The results indicate that all the compounds bind strongly and spontaneously to human serum albumin and exhibit the ability to form micelles. The determined partition coefficients were up to 6 times higher than those of the starting materials, evidencing that the ionic liquid form has greater affinity for the lipid phase than the inorganic salt form of salicylate. Generally, the studied salicylate ionic liquids exhibit an interesting pharmaceutical profile presenting favorable properties regarding the incorporation of the compounds in antimicrobial pharmaceutical formulations. It was evidenced that the tested ionic liquids can exert direct effects on cell membranes as indicated by their surfactant properties and high ability to partition to hydrophobic environments.
Chemsuschem | 2017
Susana P.F. Costa; Ana Azevedo; Paula C.A.G. Pinto; M. Lúcia M.F.S. Saraiva
This Review aims to integrate the most recent and pertinent data available on the (bio)degradability and toxicity of ionic liquids for global and critical analysis and on the conscious use of these compounds on a large scale thereafter. The integrated data will enable focus on the recognition of toxicophores and on the way the community has been dealing with them, with the aim to obtain greener and safer ionic liquids. Also, an update of the most recent biotic and abiotic methods developed to overcome some of these challenging issues will be presented. The review structure aims to present a potential sequence of events that can occur upon discharging ionic liquids into the environment and the potential long-term consequences.
Journal of Hazardous Materials | 2014
Susana P.F. Costa; Vanessa Dela Justina; Katharina Bica; Maria Vasiloiu; Paula C.A.G. Pinto; M. Lúcia M.F.S. Saraiva
The toxicity of 16 pharmaceutical active ionic liquids (IL-APIs) was evaluated by automated approaches based on sequential injection analysis (SIA). The implemented bioassays were centered on the inhibition of human carboxylesterase 2 and Vibrio fischeri, in the presence of the tested compounds. The inhibitory effects were quantified by calculating the inhibitor concentration required to cause 50% of inhibition (EC50). The EC50 values demonstrated that the cetylpyridinium group was one of the most toxic cations and that the imidazolium group was the less toxic. The obtained results provide important information about the safety of the studied IL-APIs and their possible use as pharmaceutical drugs. The developed automated SIA methodologies are robust screening bioassays, and can be used as a generic tools to identify the (eco)toxicity of the structural elements of ILs, contributing to a sustainable development of drugs.
Analytica Chimica Acta | 2015
Marieta L.C. Passos; Paula C.A.G. Pinto; João L.M. Santos; M. Lúcia M.F.S. Saraiva; André R.T.S. Araujo
Nanoparticles (NPs) exhibit a number of distinctive and entrancing properties that explain their ever increasing application in analytical chemistry, mainly as chemosensors, signaling tags, catalysts, analytical signal enhancers, reactive species generators, analyte recognition and scavenging/separation entities. The prospect of associating NPs with automated flow-based analytical is undoubtedly a challenging perspective as it would permit confined, cost-effective and reliable analysis, within a shorter timeframe, while exploiting the features of NPs. This article aims at examining state-of-the-art on continuous flow analysis and microfluidic approaches involving NPs such as noble metals (gold and silver), magnetic materials, carbon, silica or quantum dots. Emphasis is devoted to NP format, main practical achievements and fields of application. In this context, the functionalization of NPs with distinct chemical species and ligands is debated in what concerns the motivations and strengths of developed approaches. The utilization of NPs to improve detectors performance in electrochemical application is out of the scope of this review. The works discussed in this review were published in the period of time comprised between the years 2000 and 2013.
Talanta | 2009
Elane Santos da Boa Morte; Maria das Graças Andrade Korn; M. Lúcia M.F.S. Saraiva; José L. F. C. Lima; Paula C.A.G. Pinto
The present work describes the development of a fast and robust sequential injection fluorimetric procedure for the determination of Sn in juices of canned fruits. The developed automatic methodology is based on the complexation of Sn with 8-hydroxyquinoline-5-sulfonic acid (HQSA) to form a fluorimetric product (lambda(exc)=354 nm; lambda(em)=510 nm). The influence of dimethylsulfoxide (DMSO) and cetylpyridinium bromide (CPB) on the sensitivity of the fluorimetric determination was evaluated. Linear calibration plots were obtained for Sn concentrations between 1 and 10 mg L(-1), with a detection limit of 0.38 mg L(-1). In each analytical cycle 0.006 mg of HQSA and 0.47 mg of CPB were consumed and 1.5 mL of effluent was generated. The developed methodology was applied to the determination of Sn in juices of canned fruits and the results complied with those furnished by an electrothermal atomic absorption spectrometry comparison procedure, with relative deviations lower than 5.2%. The automatic procedure exhibited good precision (R.S.D.<1.4%) and the sampling rate was about 70 determinations per hour.
Talanta | 2006
Paula C.A.G. Pinto; M. Lúcia M.F.S. Saraiva; João L.M. Santos; José L. F. C. Lima
A sequential injection analysis (SIA) methodology for the fluorimetric determination of aminocaproic acid in pharmaceutical formulations is proposed. The developed analytical procedure is based on the derivatisation reaction of the aminocaproic primary amine with o-phthalaldehyde (OPA) and N-acetylcysteine (NAC) and fluorimetric detection of the formed product (lambda(ex)=350 nm; lambda(em)=450 nm). The implementation of a SIA flow system allowed for the development of a simple, fast and versatile automated methodology, which exhibits evident advantages regarding the US Pharmacopoeia 24 (USP 24) reference procedure. By combining the SIA time-based sample insertion with a subsequent zone sampling approach, which permitted to select for detection of a well-defined sample zone, it was possible to implement an on-line dilution strategy that enabled the expansion of the analytical working range of the methodology, and thus its application in dissolution studies, without manifold re-configuration. Linear calibration plots were obtained for aminocaproic acid concentrations up to 6 x 10(-5)mol l(-1). The developed methodology exhibit a good precision, with a R.S.D.<2.0% (n=15) and the detection limit was 2.5 x 10(-7)mol l(-1). The obtained results complied with those furnished by the reference procedure with a relative deviation lower than 1.2%. No interference was found.
Talanta | 2005
Eftychia-Pavlina Zisiou; Paula C.A.G. Pinto; M. Lúcia M.F.S. Saraiva; Christophe Siquet; José L. F. C. Lima
A sensitive sequential injection analysis (SIA) methodology for the fluorimetric determination of naproxen is proposed. The developed automatic analytical procedure is based on the complexation of naproxen with beta-cyclodextrin (beta-CD) yielding an enhanced fluorimetric signal (lambda(ex)=280nm, lambda(em)=356nm). Linear calibration plots were obtained for naproxen concentrations up to 1x10(-5)moll(-1). The developed methodology exhibited a good precision, with a R.S.D.<2.1% (n=15). The detection limit of the determination was 1.9x10(-7)moll(-1) with a sampling rate of about 70h(-1). The automatic method was applied to the determination of naproxen in pharmaceutical formulations. The obtained results were compared with those furnished by the reference procedure and the relative deviations were lower than 3.6%. No interference was found from the excipients usually used in solid pharmaceutical formulations.