Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Paula Petti is active.

Publication


Featured researches published by Paula Petti.


International Journal of Radiation Oncology Biology Physics | 1997

Radiosurgery for brain metastases: Relationship of dose and pattern of enhancement to local control

Cheng-Ying Shiau; Penny K. Sneed; Hui-Kuo G. Shu; Kathleen R. Lamborn; Michael W. McDermott; Susan M. Chang; Peter Nowak; Paula Petti; Vernon Smith; Lynn Verhey; Maria Ho; Elaine Park; William M. Wara; Philip H. Gutin; David A. Larson

PURPOSE This study aimed to analyze dose, initial pattern of enhancement, and other factors associated with freedom from progression (FFP) of brain metastases after radiosurgery (RS). METHODS AND MATERIALS All brain metastases treated with gamma-knife RS at the University of California, San Francisco, from 1991 to 1994 were reviewed. Evaluable lesions were those with follow-up magnetic resonance or computed tomographic imaging. Actuarial FFP was calculated using the Kaplan-Meier method, measuring FFP from the date of RS to the first imaging study showing tumor progression. Controlled lesions were censored at the time of the last imaging study. Multivariate analyses were performed using a stepwise Cox proportional hazards model. RESULTS Of 261 lesions treated in 119 patients, 219 lesions in 100 patients were evaluable. Major histologies included adenocarcinoma (86 lesions), melanoma (77), renal cell carcinoma (21), and carcinoma not otherwise specified (17). The median prescribed RS dose was 18.5 Gy (range, 10-22) and the median tumor volume was 1.3 ml (range, 0.02-30.9). The initial pattern of contrast enhancement was homogeneous in 68% of lesions, heterogeneous in 12%, and ring-enhancing in 19%. The actuarial FFP was 82% at 6 months and 77% at 1 year for all lesions, and 93 and 90%, respectively, for 145 lesions receiving > or = 18 Gy. Multivariate analysis showed that longer FFP was significantly associated with higher prescribed RS dose, a homogeneous pattern of contrast enhancement, and a longer interval between primary diagnosis and RS. Adjusted for these factors, adenocarcinomas had longer FFP than melanomas. No significant differences in FFP were noted among lesions undergoing RS for recurrence after prior radiotherapy (119 lesions), RS alone as initial treatment (45), or RS boost (55). CONCLUSION A minimum prescribed radiosurgical dose > or = 18 Gy yields excellent local control of brain metastases. The influence of pattern of enhancement on local control, a new finding in this retrospective analysis, needs to be confirmed.


International Journal of Radiation Oncology Biology Physics | 2001

Dose conformity of gamma knife radiosurgery and risk factors for complications

Lynn Verhey; Vernon Smith; Paula Petti; Kathleen R. Lamborn; David A. Larson; William M. Wara; Michael W. McDermott; Penny K. Sneed

PURPOSE To quantitatively evaluate dose conformity achieved using Gamma Knife radiosurgery, compare results with those reported in the literature, and evaluate risk factors for complications. METHODS AND MATERIALS All lesions treated at our institution with Gamma Knife radiosurgery from May 1993 (when volume criteria were routinely recorded) through December 1998 were reviewed. Lesions were excluded from analysis for reasons listed below. Conformity index (the ratio of prescription volume to target volume) was calculated for all evaluable lesions and for lesions comparable to those reported in the literature on conformity of linac radiosurgery. Univariate Cox regression models were used to test for associations between treatment parameters and toxicity. RESULTS Of 1612 targets treated in 874 patients, 274 were excluded, most commonly for unavailability of individual prescription volume data because two or more lesions were included within the same dose matrix (176 lesions), intentional partial coverage for staged treatment of large arteriovenous malformations (AVMs) (33 lesions), and missing target volume data (26 lesions). The median conformity indices were 1.67 for all 1338 evaluable lesions and 1.40-1.43 for lesions comparable to two linac radiosurgery series that reported conformity indices of 1.8 and 2.7, respectively. Among all 651 patients evaluable for complications, there were one Grade 5, eight Grade 4, and 27 Grade 3 complications. Increased risk of toxicity was associated with larger target volume, maximum lesion diameter, prescription volume, or volume of nontarget tissue within the prescription volume. CONCLUSIONS Gamma Knife radiosurgery achieves much more conformal dose distributions than those reported for conventional linac radiosurgery and somewhat more conformal dose distributions than sophisticated linac radiosurgery techniques. Larger target, nontarget, or prescription volumes are associated with increased risk of toxicity.


International Journal of Radiation Oncology Biology Physics | 1996

15 years experience with helium ion radiotherapy for uveal melanoma

Joseph R. Castro; Devron H. Char; Paula Petti; Inder K. Daftari; Jeanne M. Quivey; Rajindar P. Singh; Eleanor A. Blakely; Theodore L. Phillips

PURPOSE To review the long-term experience of helium ion therapy as a therapeutic alternative to enucleation for uveal melanoma, particularly with respect to survival, local control, and morbidity. METHODS AND MATERIALS 347 patients with uveal melanoma were treated with helium ion RT from 1978-1992. A nonrandomized dose-searching study was undertaken, with doses progressively reduced from 80 GyE in five fractions to 48 GyE in four fractions, given in 3-15 days, mean of 7 days. RESULTS Local control was achieved in 96% of patients, with no difference in the rate of local control being seen at 80, 70, 60, or 50 GyE in five fractions. At the lowest dose level of 48 GyE in four fractions, the local control rate fell to 87%. Fifteen of 347 patients (4%) had local regrowth in the eye requiring enucleation (12 patients), laser (1 patient) or reirradiation (2 patients). The time of appearance of local regrowth ranged from 4 months to 5 years posttreatment, with 85% occurring within 3 years. Of the 347 patients, 208 are alive as of May 1, 1997. The median follow up of all patients is 8.5 years, range 1-17 years. Kaplan-Maier (K-M) survival is 80% at 5 years, 76% at 10 years, and 72% at 15 years posttreatment. Patients with tumors not involving the ciliary body have a 15-year K-M survival of 80%. The results for patients whose tumors involved the ciliary body are poor, with a 15-year K-M survival of 43%. Seventy-five percent of patients with tumors at least 3.0 mm from the fovea and optic nerve, and initial ultrasound height less than 6.0 mm, retained vision of 20/200 or better posttreatment. Patients with tumors larger than 6 mm in thickness, or with tumors lying close to the optic nerve or fovea, have a reduced chance of retaining useful vision. The enucleation rate is 19%, 3% for local failure and 16% because of complications of the helium RT, particularly neovascular glaucoma, which occurred in 35% of patients. CONCLUSIONS Local control and retention of the eye are excellent. Complications of therapy reduce vision and eye preservation. Twenty-four percent of patients manifested distant metastases 6 to 146 months posttreatment, mean of 43 months, median of 36 months. Late-appearing distant metastases do not appear to be caused by persistent tumor in the eye. The risk of metastases is high for patients with tumors greater than 7 mm in initial ultrasound height (37%), anterior tumors involving the ciliary body (47%), and in those with local failure (53%). Patients with tumors not involving the ciliary body and initial dimensions less than 10 mm had only an 8% chance of death from melanoma. A search for effective adjuvant therapy is needed for patients at high risk of metastases (large tumors, ciliary body involved, local regrowth in eye).


Journal of Neurosurgery | 2009

Radiosurgery for malignant meningioma: results in 22 patients

Steven G. Ojemann; Penny K. Sneed; David A. Larson; Philip H. Gutin; Mitchel S. Berger; Lynn Verhey; Vernon Smith; Paula Petti; William M. Wara; Elaine Park; Michael W. McDermott

The purpose of this paper was to note a potential source of error in magnetic resonance (MR) imaging. Magnetic resonance images were acquired for stereotactic planning for GKS of a vestibular schwannoma in a female patient. The images were acquired using three-dimensional sequence, which has been shown to produce minimal distortion effects. The images were transferred to the planning workstation, but the coronal images were rejected. By examination of the raw data and reconstruction of sagittal images through the localizer side plate, it was clearly seen that the image of the square localizer system was grossly distorted. The patient was returned to the MR imager for further studies and a metal clasp on her brassiere was identified as the cause of the distortion.A-60-year-old man with medically intractable left-sided maxillary division trigeminal neuralgia had severe cardiac disease, was dependent on an internal defibrillator and could not undergo magnetic resonance imaging. The patient was successfully treated using computerized tomography (CT) cisternography and gamma knife radiosurgery. The patient was pain free 2 months after GKS. Contrast cisternography with CT scanning is an excellent alternative imaging modality for the treatment of patients with intractable trigeminal neuralgia who are unable to undergo MR imaging.The authors describe acute deterioration in facial and acoustic neuropathies following radiosurgery for acoustic neuromas. In May 1995, a 26-year-old man, who had no evidence of neurofibromatosis Type 2, was treated with gamma knife radiosurgery (GKS; maximum dose 20 Gy and margin dose 14 Gy) for a right-sided intracanalicular acoustic tumor. Two days after the treatment, he developed headache, vomiting, right-sided facial weakness, tinnitus, and right hearing loss. There was a deterioration of facial nerve function and hearing function from pretreatment values. The facial function worsened from House-Brackmann Grade 1 to 3. Hearing deteriorated from Grade 1 to 5. Magnetic resonance (MR) images, obtained at the same time revealed an obvious decrease in contrast enhancement of the tumor without any change in tumor size or peritumoral edema. Facial nerve function improved gradually and increased to House-Brackmann Grade 2 by 8 months post-GKS. The tumor has been unchanged in size for 5 years, and facial nerve function has also been maintained at Grade 2 with unchanged deafness. This is the first detailed report of immediate facial neuropathy after GKS for acoustic neuroma and MR imaging revealing early possibly toxic changes. Potential explanations for this phenomenon are presented.In clinical follow-up studies after radiosurgery, imaging modalities such as computerized tomography (CT) and magnetic resonance (MR) imaging are used. Accurate determination of the residual lesion volume is necessary for realistic assessment of the effects of treatment. Usually, the diameters rather than the volume of the lesion are measured. To determine the lesion volume without using stereotactically defined images, the software program VOLUMESERIES has been developed. VOLUMESERIES is a personal computer-based image analysis tool. Acquired DICOM CT scans and MR image series can be visualized. The region of interest is contoured with the help of the mouse, and then the system calculates the volume of the contoured region and the total volume is given in cubic centimeters. The defined volume is also displayed in reconstructed sagittal and coronal slices. In addition, distance measurements can be performed to measure tumor extent. The accuracy of VOLUMESERIES was checked against stereotactically defined images in the Leksell GammaPlan treatment planning program. A discrepancy in target volumes of approximately 8% was observed between the two methods. This discrepancy is of lesser interest because the method is used to determine the course of the target volume over time, rather than the absolute volume. Moreover, it could be shown that the method was more sensitive than the tumor diameter measurements currently in use. VOLUMESERIES appears to be a valuable tool for assessing residual lesion volume on follow-up images after gamma knife radiosurgery while avoiding the need for stereotactic definition.This study was conducted to evaluate the geometric distortion of angiographic images created from a commonly used digital x-ray imaging system and the performance of a commercially available distortion-correction computer program. A 12 x 12 x 12-cm wood phantom was constructed. Lead shots, 2 mm in diameter, were attached to the surfaces of the phantom. The phantom was then placed inside the angiographic localizer. Cut films (frontal and lateral analog films) of the phantom were obtained. The films were analyzed using GammaPlan target series 4.12. The same procedure was repeated with a digital x-ray imaging system equipped with a computer program to correct the geometric distortion. The distortion of the two sets of digital images was evaluated using the coordinates of the lead shots from the cut films as references. The coordinates of all lead shots obtained from digital images and corrected by the computer program coincided within 0.5 mm of those obtained from cut films. The average difference is 0.28 mm with a standard deviation of 0.01 mm. On the other hand, the coordinates obtained from digital images with and without correction can differ by as much as 3.4 mm. The average difference is 1.53 mm, with a standard deviation of 0.67 mm. The investigated computer program can reduce the geometric distortion of digital images from a commonly used x-ray imaging system to less than 0.5 mm. Therefore, they are suitable for the localization of arteriovenous malformations and other vascular targets in gamma knife radiosurgery.


International Journal of Radiation Oncology Biology Physics | 1993

Charged particle irradiation of sacral chordomas

Robin Schoenthaler; Joseph R. Castro; Paula Petti; Kari Baken-Brown; Theodore L Hillips

PURPOSE The purpose of this report is determine the impact of charged particle irradiation at Lawrence Berkeley Laboratory (LBL) in treating patients with sacral chordomas. Overall survival, local control, complications, and predictive parameters are analyzed. METHODS AND MATERIALS Fourteen patients with sacral chordomas were treated with the charged particles helium and neon between 1977 and 1989. The median dose was 7565 cGyE and the median follow up is 5 years. All patients were treated post-operatively; ten had gross residual disease. RESULTS Kaplan-Meier survival at 5 years is 85%. Overall 5-year local control is 55%. A trend to improved local control at 5 years was seen in patients treated with neon when compared to patients treated with helium (62% vs 34%), in patients following complete resection versus patients with gross residual tumor (75% vs 40%), and in patients who had treatment courses under 73 days (61% vs 21%). Distant metastases were seen in two patients (14%). No patient developed neurologic sequelae or pain syndromes. One previously irradiated patient required colostomy, one patient had delayed wound healing following a negative post-radiation biopsy, and one patient developed a second malignancy. There were no genitourinary complications. CONCLUSION Our experience indicates that post-operative charged particle irradiation of sacral chordomas appears to result in reasonable local control and survival with acceptable risk, and that additional evaluation on the use of heavy charged particles is warranted.


Technology in Cancer Research & Treatment | 2007

Image-Guided Robotic Stereotactic Body Radiotherapy for Benign Spinal Tumors: The University of California San Francisco Preliminary Experience

A Sahgal; Dean Chou; Christopher P. Ames; Lijun Ma; Kathleen R. Lamborn; Kim Huang; Cynthia H. Chuang; Ashley H. Aiken; Paula Petti; Phil Weinstein; David A. Larson

We evaluate our preliminary experience using the Cyberknife® Radiosurgery System in treating benign spinal tumors. A retrospective review of 16 consecutively treated patients, comprising 19 benign spinal tumors, was performed. Histologic types included neurofibroma [11], chordoma [4], hemangioma [2], and meningioma [2]. Three patients had Neurofibromatosis Type 1 (NF1). Only one tumor, recurrent chordoma, had been previously irradiated, and as such not considered in the local failure analysis. Local failure, for the remaining 18 tumors, was based clinically on symptom progression and/or tumor enlargement based on imaging. Indications for spine stereotactic body radiotherapy (SBRT) consisted of either adjuvant to subtotal resection (5/19), primary treatment alone (12/19), boost following external beam radiotherapy (1/19), and salvage following previous radiation (1/19). Median tumor follow-up is 25 months (2–37), and one patient (with NF1) died at 12 months from a stroke. The median total dose, number of fractions, and prescription isodose was 21 Gy (10–30 Gy), 3 fx (1–5 fx), 80% (42–87%). The median tumor volume was 7.6 cc (0.2–274.1 cc). The median V100 (volume V receiving 100% of the prescribed dose) and maximum tumor dose was 95% (77–100%) and 26.7 Gy (15.4–59.7 Gy), respectively. Three tumors progressed at 2, 4, and 36 months post-SR (n=18). Two tumors were neurofibromas (both in NF1 patients), and the third was an intramedullary hemangioblastoma. Based on imaging, two tumors had MRI documented progression, three had regressed, and 13 were unchanged (n=18). With short follow-up, local control following Cyberknife spine SBRT for benign spinal tumors appear acceptable.


International Journal of Radiation Oncology Biology Physics | 1997

Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

Inder K. Daftari; Devron H. Char; Lynn J. Verhey; Joseph R. Castro; Paula Petti; William J. Meecham; Stewart Kroll; Eleanor A. Blakely

PURPOSE The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. METHODS AND MATERIALS 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. RESULTS NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. CONCLUSION The development of NVG after helium-ion irradiation is correlated to the amount of lens, anterior chamber in the treatment field, tumor height, proximity to the fovea, history of diabetes, and the development of vitreous hemorrhage. Although the influence of the higher LET deposition of helium-ions is unclear, this study suggests that by reducing the dose to the anterior segment of the eye may reduce the NVG complications. Based on this retrospective analysis of LBNL patients, we have implemented techniques to reduce the amount of the anterior segment receiving a high dose in our new series of patients treated with protons using the cyclotron at the UC Davis Crocker Nuclear Laboratory (CNL).


International Journal of Radiation Oncology Biology Physics | 2003

Comparison of intensity-modulated radiosurgery with gamma knife radiosurgery for challenging skull base lesions.

Andrea Pirzkall; Mark Carol; P. Xia; Vernon Smith; William M. Wara; Paula Petti; Lynn Verhey; Penny K. Sneed

PURPOSE To quantitatively compare intensity-modulated radiosurgery (IMRS) using 3-mm mini-multileaf collimation with gamma knife radiosurgery (GKRS) plans for irregularly shaped skull base lesions in direct proximity to organs at risk (OAR). METHODS AND MATERIALS Ten challenging skull base lesions originally treated with GKRS were selected for comparison with IMRS using inverse treatment planning and 3-mm mini-multileaf collimation operating in step-and-shoot delivery mode. The lesions ranged in volume from 1.6 to 32.2 cm(3) and were treated with 9-20 GK isocenters (mean 13.2). The IMRS plans were designed with the intent to, at minimum, match the GKRS plans with regard to OAR sparing and target coverage. For each case, IMRS plans were generated using 9 coplanar, 11 equally spaced noncoplanar, and 11 OAR-avoidant noncoplanar beams; the best of these approaches with respect to target conformality, sparing of OAR, and maintaining coverage was selected for comparison with the original GKRS plan. RESULTS Assuming no patient motion or setup error, IMRS provided comparable target coverage and sparing of OAR and an improved conformity index at the prescription isodose contour but sometimes less conformity at lower isodose contours compared with the actual GKRS plan. All IMRS plans produced less target dose heterogeneity and shorter estimated treatment times compared with the GKRS plans. CONCLUSION Compared with GKRS for complex skull base lesions, IMRS plans using a 3-mm mini-multileaf collimator achieved comparable or sometimes improved target coverage, conformity, and critical structure sparing with shorter estimated treatment times.


International Journal of Radiation Oncology Biology Physics | 1992

Charged particle radiotherapy of paraspinal tumors.

Valerie Nowakowski; Joseph R. Castro; Paula Petti; J.M. Collier; Inder K. Daftari; David K. Ahn; Grant E. Gauger; Philip H. Gutin; David E. Linstadt; Theodore L. Phillips

Between 1976 and 1987, 52 patients with tumors adjacent to and/or involving the cervical, thoracic, or lumbar spinal cord were treated with charged particles at the University of California Lawrence Berkeley Laboratory. The histologies included chordoma and chondrosarcoma (24 pts), other bone and soft tissue sarcoma (14 pts), and metastatic or unusual histology tumors (14 pts). Radiation doses ranged from 29 to 80 Gray-equivalent (GyE), with a median dose of 70 GyE. Twenty-one patients received a portion of their treatment with photons. Median followup was 28 months. For 36 previously untreated patients, local control was achieved in 21/36 patients and the 3-year actuarial survival was 61%. Of 16 patients treated for recurrent disease, 7/16 were locally controlled and the 3-year actuarial survival was 51%. For patients treated for chordoma and chondrosarcoma, probability of local control was influenced by tumor volume (less than 100 cc or greater than 150 cc) and whether disease was recurrent or previously untreated. Complications occurred in 6/52 patients, including one spinal cord injury, one cauda equina and one brachial plexus injury, and three instances of skin or subcutaneous fibrosis. Charged particle radiotherapy can safely deliver high tumor doses to paraspinal tumors with good local control.


Medical Physics | 2007

Effects of residual target motion for image-tracked spine radiosurgery

Cynthia H. Chuang; A Sahgal; Letitia Lee; David A. Larson; Kim Huang; Paula Petti; Lynn Verhey; Lijun Ma

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties (-1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

Collaboration


Dive into the Paula Petti's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lynn Verhey

University of California

View shared research outputs
Top Co-Authors

Avatar

Lijun Ma

University of California

View shared research outputs
Top Co-Authors

Avatar

Vernon Smith

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Philip H. Gutin

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge