Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Paulo G. Coelho is active.

Publication


Featured researches published by Paulo G. Coelho.


PLOS ONE | 2014

Nanometer Scale Titanium Surface Texturing Are Detected by Signaling Pathways Involving Transient FAK and Src Activations

Willian Fernando Zambuzzi; Estevam A. Bonfante; Ryo Jimbo; Mariko Hayashi; Martin Andersson; Gutemberg Gomes Alves; Esther Rieko Takamori; Paulo José I. Beltrão; Paulo G. Coelho; José Mauro Granjeiro

Background It is known that physico/chemical alterations on biomaterial surfaces have the capability to modulate cellular behavior, affecting early tissue repair. Such surface modifications are aimed to improve early healing response and, clinically, offer the possibility to shorten the time from implant placement to functional loading. Since FAK and Src are intracellular proteins able to predict the quality of osteoblast adhesion, this study evaluated the osteoblast behavior in response to nanometer scale titanium surface texturing by monitoring FAK and Src phosphorylations. Methodology Four engineered titanium surfaces were used for the study: machined (M), dual acid-etched (DAA), resorbable media microblasted and acid-etched (MBAA), and acid-etch microblasted (AAMB). Surfaces were characterized by scanning electron microscopy, interferometry, atomic force microscopy, x-ray photoelectron spectroscopy and energy dispersive X-ray spectroscopy. Thereafter, those 4 samples were used to evaluate their cytotoxicity and interference on FAK and Src phosphorylations. Both Src and FAK were investigated by using specific antibody against specific phosphorylation sites. Principal Findings The results showed that both FAK and Src activations were differently modulated as a function of titanium surfaces physico/chemical configuration and protein adsorption. Conclusions It can be suggested that signaling pathways involving both FAK and Src could provide biomarkers to predict osteoblast adhesion onto different surfaces.


Advances in Dental Research | 2016

A Critical Perspective on Mechanical Testing of Implants and Prostheses

Estevam A. Bonfante; Paulo G. Coelho

The degree of interplay among variables in dental implant treatment presents a challenge to randomized clinical trials attempting to answer questions in a timely, unbiased, and economically feasible fashion. Further adding complexity to the different scenarios is the varied implant designs and related bone response, area of implantation, implant bulk material, restoration, abutments and related screws, fixation mode (screwed, fixed, or a combination), and horizontal implant-abutment matching geometry. This article critically appraises the most common mechanical testing methods used to characterize the implant-prostheses complex. It attempts to provide insight into the process of construction of an informed database of clinically relevant questions regarding preclinical evaluation of implant biomechanics and failure mechanisms. The use of single load to failure, fatigue life, fatigue limit, and step-stress accelerated life testing is discussed with emphasis on their deliverables, weaknesses, and strengths. Fractographic analysis and challenges in the correlation between laboratory- and in-service-produced failures of dental ceramics, resin composites, and titanium are introduced. In addition, examples are presented of mechanical characterization studies used in our laboratory to assess some implant-supported rehabilitation variables.


JCI insight | 2017

Store-operated Ca2+ entry controls ameloblast cell function and enamel development

Miriam Eckstein; Martin Vaeth; Cinzia Fornai; Manikandan Vinu; Timothy G. Bromage; Meerim K. Nurbaeva; Jessica L. Sorge; Paulo G. Coelho; Youssef Idaghdour; Stefan Feske; Rodrigo S. Lacruz

Loss-of-function mutations in stromal interaction molecule 1 (STIM1) impair the activation of Ca2+ release-activated Ca2+ (CRAC) channels and store-operated Ca2+ entry (SOCE), resulting in a disease syndrome called CRAC channelopathy that is characterized by severe dental enamel defects. The cause of these enamel defects has remained unclear given a lack of animal models. We generated Stim1/2K14cre mice to delete STIM1 and its homolog STIM2 in enamel cells. These mice showed impaired SOCE in enamel cells. Enamel in Stim1/2K14cre mice was hypomineralized with decreased Ca content, mechanically weak, and thinner. The morphology of SOCE-deficient ameloblasts was altered, showing loss of the typical ruffled border, resulting in mislocalized mitochondria. Global gene expression analysis of SOCE-deficient ameloblasts revealed strong dysregulation of several pathways. ER stress genes associated with the unfolded protein response were increased in Stim1/2-deficient cells, whereas the expression of components of the glutathione system were decreased. Consistent with increased oxidative stress, we found increased ROS production, decreased mitochondrial function, and abnormal mitochondrial morphology in ameloblasts of Stim1/2K14cre mice. Collectively, these data show that loss of SOCE in enamel cells has substantial detrimental effects on gene expression, cell function, and the mineralization of dental enamel.


International Journal of Periodontics & Restorative Dentistry | 2016

Clinical Comparison of At-Home and In-Office Dental Bleaching Procedures: A Randomized Trial of a Split-Mouth Design.

Lucas Silveira Machado; Rodolfo Bruniera Anchieta; Paulo Henrique dos Santos; André Luiz Fraga Briso; Nick Tovar; Malvin N. Janal; Paulo G. Coelho; Renato Herman Sundfeld

The objective of this split-mouth clinical study was to compare a combination of in-office and at-home dental bleaching with at-home bleaching alone. Two applications of in-office bleaching were performed, with one appointment per week, using 38% hydrogen peroxide. At-home bleaching was performed with or without in-office bleaching using 10% carbamide peroxide in a custom-made tray every night for 2 weeks. The factor studied was the bleaching technique on two levels: Technique 1 (in-office bleaching combined with home bleaching) and Technique 2 (home bleaching only). The response variables were color change, dental sensitivity, morphology, and surface roughness. The maxillary right and left hemiarches of the participants were submitted to in-office placebo treatment and in-office bleaching, respectively (Phase 1), and at-home bleaching (Phase 2) treatment was performed on both hemiarches, characterizing a split-mouth design. Enamel surface changes and roughness were analyzed with scanning electron microscopy and optical interferometry using epoxy replicas. No statistically significant differences were observed between the bleaching techniques for either the visual or the digital analyses. There was a significant difference in dental sensitivity when both dental bleaching techniques were used, with in-office bleaching producing the highest levels of dental sensitivity after the baseline. Microscopic analysis of the morphology and roughness of the enamel surface showed no significant changes between the bleaching techniques. The two techniques produced similar results in color change, and the combination technique produced the highest levels of sensitivity. Neither technique promoted changes in morphology or surface roughness of enamel.


Operative Dentistry | 2017

Microcomputed tomography evaluation of polymerization shrinkage of class i flowable resin composite restorations

Camila S. Sampaio; K. J. Chiu; E. Farrokhmanesh; Malvin N. Janal; Regina Maria Puppin-Rontani; Marcelo Giannini; Estevam A. Bonfante; Paulo G. Coelho; Ronaldo Hirata

The present study aimed to characterize the pattern and volume of polymerization shrinkage of flowable resin composites, including one conventional, two bulk fill, and one self-adhesive. Standardized class I preparations (2.5 mm depth × 4 mm length × 4 mm wide) were performed in 24 caries-free human third molars that were randomly divided in four groups, according to the resin composite and adhesive system used: group 1 = Permaflo + Peak Universal Bond (PP); group 2 = Filtek Bulk Fill + Scotchbond Universal (FS); group 3 = Surefil SDR + XP Bond (SX); and group 4 = Vertise flow self-adhering (VE) (n=6). Each tooth was scanned three times using a microcomputed tomography (μCT) apparatus. The first scan was done after the cavity preparation, the second after cavity filling with the flowable resin composite before curing, and the third after it was cured. The μCT images were imported into three-dimensional rendering software, and volumetric polymerization shrinkage percentage was calculated for each sample. Data were submitted to one-way analysis of variance and post hoc comparisons. No significant difference was observed among PP, FS, and VE. SX bulk fill resin composite presented the lowest values of volumetric shrinkage. Shrinkage was mostly observed along the occlusal surface and part of the pulpal floor. In conclusion, polymerization shrinkage outcomes in a 2.5-mm deep class I cavity were material dependent, although most materials did not differ. The location of shrinkage was mainly at the occlusal surface.


Journal of The Mechanical Behavior of Biomedical Materials | 2016

Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep

Bradley Lahens; Rodrigo Neiva; Nick Tovar; Adham M. Alifarag; Ryo Jimbo; Estevam A. Bonfante; Michelle Bowers; Marla Cuppini; Helora Freitas; Lukasz Witek; Paulo G. Coelho

A bone drilling concept, namely osseodensification, has been introduced for the placement of endosteal implants to increase primary stability through densification of the osteotomy walls. This study investigated the effect of osseodensification on the initial stability and early osseointegration of conical and parallel walled endosteal implants in low density bone. Five male sheep were used. Three implants were inserted in the ilium, bilaterally, totaling 30 implants (n=15 conical, and n=15 parallel). Each animal received 3 implants of each type, inserted into bone sites prepared as follows: (i) regular-drilling (R: 2mm pilot, 3.2mm, and 3.8mm twist drills), (ii) clockwise osseodensification (CW), and (iii) counterclockwise (CCW) osseodensification drilling with Densah Bur (Versah, Jackson, MI, USA): 2.0mm pilot, 2.8mm, and 3.8mm multi-fluted burs. Insertion torque as a function of implant type and drilling technique, revealed higher values for osseodensification relative to R-drilling, regardless of implant macrogeometry. A significantly higher bone-to-implant contact (BIC) for both osseodensification techniques (p<0.05) was observed compared to R-drilling. There was no statistical difference in BIC as a function of implant type (p=0.58), nor in bone-area-fraction occupancy (BAFO) as a function of drilling technique (p=0.22), but there were higher levels of BAFO for parallel than conic implants (p=0.001). Six weeks after surgery, new bone formation along with remodeling sites was observed for all groups. Bone chips in proximity with the implants were seldom observed in the R-drilling group, but commonly observed in the CW, and more frequently under the CCW osseodensification technique. In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods.


Implant Dentistry | 2015

Surface characterization and in vivo evaluation of dual Acid-etched and grit-blasted/acid-etched implants in sheep.

Daniel Yoo; Charles Marin; Gileade Freitas; Nick Tovar; Estevam A. Bonfante; Hellen S. Teixeira; Malvin N. Janal; Paulo G. Coelho

Purpose:Dual acid-etching is widely used to modify dental implant topography and enhance early bone healing. This study evaluated the histomorphometric, biomechanical, and histological bone response to acid-etched (AA) in comparison with grit-blasted/acid-etched (GB) and machined control (C) implants within sites of relatively low-bone remodeling rates. Materials and Methods:Implant surface topography was evaluated by scanning electron microscopy and optical interferometry (IFM). Six adult male sheep (n = 6) received 72 Ti-6Al-4V implants (n = 24 per surface) in both ilium (n = 12 per bone bilaterally). The implants remained for 3 and 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Biomechanical analysis consisted of torque-to-interface failure. Results:IFM analysis showed the highest average surface roughness for GB and the highest density of summits and developed surface area percentage (P < 0.01) for AA. No difference was observed in BAFO for all groups in 3 and 6 weeks. Increased BIC and torque resistance were observed for AA implants at both time points after implantation. Conclusions:Overall, improved bone-to-implant response was observed for the AA implant surface.


Journal of Prosthodontics | 2018

Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs

Dimorvan Bordin; Lukasz Witek; Vinicius P. Fardin; Estevam A. Bonfante; Paulo G. Coelho

PURPOSE To evaluate the reliability of narrow diameter dental implants (NDIs) with similar macrogeometry and 3 implant-abutment connection designs. MATERIALS AND METHODS Eighty-four NDIs (3.5 × 10 mm) were selected and divided into 4 groups (n = 21/group) according to implant-abutment connection design, as follows: EH - external hexagon, IH - internal hexagon, IC - internal conical, and IC-M - internal conical connected to a monolithic titanium abutment. Identical abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. Use of level probability Weibull curves, and reliability for a mission of 50,000 cycles at 75 N and 200 N were calculated. RESULTS The beta (β) values were: 1.48 for IC, 1.40 for IC-M, 8.54 for EH, and 1.98 for IH, indicating that damage accumulation was an acceleration factor for failure of all groups. At 75 N the probability of survival was not significantly different between groups. A decrease in reliability was observed for all groups at 200 N with no significant differences between IC (81.71%) and IC-M (94.28%), or between EH and IH (0%) which presented the lowest values. EH failures were primarily restricted to the screw, while IH involved screw and implant fracture. IC and IC-M were restricted to prosthetic failures (fracture and bending). CONCLUSIONS Narrow implants with external or internal hexagon connections presented the lowest reliability at high loads compared to internal conical connections. Failure modes differed among connections.


ACS Nano | 2017

Exosomes Mediate Epithelium-Mesenchyme Crosstalk in Organ Development

Nan Jiang; Lusai Xiang; Ling He; Guodong Yang; Jinxuan Zheng; Chenglin Wang; Yimei Zhang; Sainan Wang; Yue Zhou; Tzong-Jen Sheu; Jia Qian Wu; Kenian Chen; Paulo G. Coelho; Nicky M. Tovar; Shin Hye Kim; Mo Chen; Yan Heng Zhou; Jeremy J. Mao

Organ development requires complex signaling by cells in different tissues. Epithelium and mesenchyme interactions are crucial for the development of skin, hair follicles, kidney, lungs, prostate, major glands, and teeth. Despite myriad literature on cell-cell interactions and ligand-receptor binding, the roles of extracellular vesicles in epithelium-mesenchyme interactions during organogenesis are poorly understood. Here, we discovered that ∼100 nm exosomes were secreted by the epithelium and mesenchyme of a developing tooth organ and diffused through the basement membrane. Exosomes were entocytosed by epithelium or mesenchyme cells with preference by reciprocal cells rather than self-uptake. Exosomes reciprocally evoked cell differentiation and matrix synthesis: epithelium exosomes induce mesenchyme cells to produce dentin sialoprotein and undergo mineralization, whereas mesenchyme exosomes induce epithelium cells to produce basement membrane components, ameloblastin and amelogenenin. Attenuated exosomal secretion by Rab27a/b knockdown or GW4869 disrupted the basement membrane and reduced enamel and dentin production in organ culture and reduced matrix synthesis and the size of the cervical loop, which harbors epithelium stem cells, in Rab27aash/ash mutant mice. We then profiled exosomal constituents including miRNAs and peptides and further crossed all epithelium exosomal miRNAs with literature-known miRNA Wnt regulators. Epithelium exosome-derived miR135a activated Wnt/β-catenin signaling and escalated mesenchymal production of dentin matrix proteins, partially reversible by Antago-miR135a attenuation. Our results suggest that exosomes may mediate epithelium-mesenchyme crosstalk in organ development, suggesting that these vesicles and/or the molecular contents they are transporting may be interventional targets for treatment of diseases or regeneration of tissues.


International Journal of Oral & Maxillofacial Implants | 2016

Biomechanical, Biologic, and Clinical Outcomes of Undersized Implant Surgical Preparation: A Systematic Review

Michele Stocchero; Marco Toia; Denis Cecchinato; Jonas P. Becktor; Paulo G. Coelho; Ryo Jimbo

PURPOSE To compile the current evidence on biomechanical, biologic, and clinical outcomes of undersized surgical preparation protocols in dental implant surgery. MATERIALS AND METHODS An electronic search using three different databases (PubMed, Web of Science, and Cochrane Library) and a manual hand search were performed including in vitro, animal, and clinical studies published prior to October 2015. Studies in which an undersized drilling protocol was compared with a nonundersized drilling protocol were included. RESULTS From an initial selection of 1,655 titles, 29 studies met the inclusion criteria, including 14 biomechanical, 7 biologic, 6 biologic and biomechanical, and 2 clinical. Due to methodologic variation, meta-analysis was not performed. Several studies showed that implants inserted with an undersized drilling approach reached a significantly higher insertion torque value than conventional drilling in low-density substrates, while this effect is less evident if a thick cortical layer is present. Similar results in terms of boneto-implant contact (BIC) were achieved in the longer term between implants inserted with undersized and nonundersized protocols. Results in the short term were inconclusive. Clinical studies did not show negative outcomes for undersized drilling, although clinical evidence was sparse. No data are available on marginal bone loss. CONCLUSION From the biomechanical standpoint, an undersized drilling protocol is effective in increasing insertion torque in low-density bone. Biologic response in long-term healing after undersized implant placement is comparable to that in the nonundersized surgical drilling protocol. Clinical studies indicate that performing an undersized drilling protocol on low-density bone is a safe procedure; however, more extensive studies are needed to confirm these data.

Collaboration


Dive into the Paulo G. Coelho's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge