Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Peijun Lü is active.

Publication


Featured researches published by Peijun Lü.


Computer Methods and Programs in Biomedicine | 2009

Study on CAD&RP for removable complete denture

Yuchun Sun; Peijun Lü; Yong Wang

This study explored a method for fabricating removable complete denture aided by CAD&RP technology. 3D crossing section scanner and laser scanner were respectively applied to obtain the surface data of artificial teeth, edentulous models and rims made in clinic. The vertical and horizontal relations of models were recorded before scanning with a special device. A 3D graphic database of artificial teeth, which can be aligned with parameters, was established. Special CAD software developed by ourselves was applied to the 3D integrated design process including automatic setting up artificial teeth, semiautomatic designing aesthetic and individualized artificial gingiva and base plate, automatic constructing individualized virtual flasks according to the finished CAD digital models of removable complete denture. At last, 3DP technology was used to make the individualized physical flasks. In this study, AMT and classic denture materials were effectually combined to achieve making removable complete denture aided by CAD/RP technology.


RSC Advances | 2016

Nano hydroxyapatite particles promote osteogenesis in a three-dimensional bio-printing construct consisting of alginate/gelatin/hASCs

Xiao-Fei Wang; Peijun Lü; Yang Song; Yuchun Sun; Yu-Guang Wang; Yong Wang

To design a hydrogel material containing nano hydroxyapatite particles for three-dimensional (3D) bio-printing of human adipose-derived stem cells (hASCs) and to explore whether nano hydroxyapatite particles can promote osteogenic differentiation of a 3D bio-printing construct consisting of hASCs in vivo and in vitro. A 3D reticular printing structure was designed. Sodium alginate/gelatin/hASCs (AG group) was considered as the control group, and sodium alginate/gelatin/nano hydroxyapatite/hASCs (AGH group) was considered as the experimental group. Immunofluorescence microscopy was used to observe the cell viability and cell adhesion, and cell proliferation was analyzed by comparison of viable cell numbers in printed constructs at 1 day and 7 days after printing. After 14 days of osteogenic induction for the AG group and AGH group, real-time quantitative PCR and immunofluorescence were used to analyse the expression of the osteogenesis-related genes Runt-related transcription factor 2 (RUNX2), osterix (OSX), and osteocalcin (OCN). New bone formation in printed constructs was observed using micro-CT, HE staining, Masson trichrome staining, and OCN immunohistochemical staining 8 weeks after being implanted. The cells in the AG group and AGH group were evenly distributed in the 3D printed constructs. The number of viable cells and cell viability both in the AG group and AGH group at 7 days after printing were higher than those at 1 day after printing (p < 0.05); however, the difference between the AG group and AGH group was not significant. At 14 days after osteogenic induction in vitro, real-time PCR results showed that the expression of osteogenesis-related genes in the AGH OM group was significantly higher than that in the AGH PM group, AG PM group, and AG OM group (p < 0.05). At 8 weeks after bio-printed construct implantation, the results of micro-CT, HE staining, Masson trichrome staining, and OCN immunohistochemical staining showed that the new bone formation in the AGH group was higher than that in the AG group (p < 0.05). The in vivo and in vitro results demonstrated that nano hydroxyapatite particles dispersed in a sodium alginate/gelatin matrix could promote osteogenic differentiation of hASCs in a 3D bio-printed construct, and this scaffold material could be considered to repair large bone tissue defects.


PLOS ONE | 2015

A Method of Three-Dimensional Recording of Mandibular Movement Based on Two-Dimensional Image Feature Extraction.

Fusong Yuan; Huaxin Sui; Zhongke Li; Huifang Yang; Peijun Lü; Yong Wang; Yuchun Sun

Background and Objective To develop a real-time recording system based on computer binocular vision and two-dimensional image feature extraction to accurately record mandibular movement in three dimensions. Methods A computer-based binocular vision device with two digital cameras was used in conjunction with a fixed head retention bracket to track occlusal movement. Software was developed for extracting target spatial coordinates in real time based on two-dimensional image feature recognition. A plaster model of a subject’s upper and lower dentition were made using conventional methods. A mandibular occlusal splint was made on the plaster model, and then the occlusal surface was removed. Temporal denture base resin was used to make a 3-cm handle extending outside the mouth connecting the anterior labial surface of the occlusal splint with a detection target with intersecting lines designed for spatial coordinate extraction. The subjects head was firmly fixed in place, and the occlusal splint was fully seated on the mandibular dentition. The subject was then asked to make various mouth movements while the mandibular movement target locus point set was recorded. Comparisons between the coordinate values and the actual values of the 30 intersections on the detection target were then analyzed using paired t-tests. Results The three-dimensional trajectory curve shapes of the mandibular movements were consistent with the respective subject movements. Mean XYZ coordinate values and paired t-test results were as follows: X axis: -0.0037 ± 0.02953, P = 0.502; Y axis: 0.0037 ± 0.05242, P = 0.704; and Z axis: 0.0007 ± 0.06040, P = 0.952. The t-test result showed that the coordinate values of the 30 cross points were considered statistically no significant. (P<0.05) Conclusions Use of a real-time recording system of three-dimensional mandibular movement based on computer binocular vision and two-dimensional image feature recognition technology produced a recording accuracy of approximately ± 0.1 mm, and is therefore suitable for clinical application. Certainly, further research is necessary to confirm the clinical applications of the method.


Journal of Biomedical Optics | 2015

Femtosecond laser ablation of dentin and enamel: relationship between laser fluence and ablation efficiency

Hu Chen; Jing Liu; Hong Li; Wenqi Ge; Yuchun Sun; Yong Wang; Peijun Lü

Abstract. The objective was to study the relationship between laser fluence and ablation efficiency of a femtosecond laser with a Gaussian-shaped pulse used to ablate dentin and enamel for prosthodontic tooth preparation. A diode-pumped thin-disk femtosecond laser with wavelength of 1025 nm and pulse width of 400 fs was used for the ablation of dentin and enamel. The laser spot was guided in a line on the dentin and enamel surfaces to form a groove-shaped ablation zone under a series of laser pulse energies. The width and volume of the ablated line were measured under a three-dimensional confocal microscope to calculate the ablation efficiency. Ablation efficiency for dentin reached a maximum value of 0.020  mm3/J when the laser fluence was set at 6.51  J/cm2. For enamel, the maximum ablation efficiency was 0.009  mm3/J at a fluence of 7.59  J/cm2. Ablation efficiency of the femtosecond laser on dentin and enamel is closely related to the laser fluence and may reach a maximum when the laser fluence is set to an appropriate value.


Journal of Biomedical Optics | 2015

Surface roughness and wettability of dentin ablated with ultrashort pulsed laser

Jing Liu; Peijun Lü; Yuchun Sun; Yong Wang

Abstract. The aim of this study was to evaluate the surface roughness and wettability of dentin following ultrashort pulsed laser ablation with different levels of fluence and pulse overlap (PO). Twenty-five extracted human teeth crowns were cut longitudinally into slices of approximately 1.5-mm thick and randomly divided into nine groups of five. Samples in groups 1 to 8 were ablated with an ultrashort pulsed laser through a galvanometric scanning system. Samples in group 9 were prepared using a mechanical rotary instrument. The surface roughness of samples from each group was then measured using a three-dimensional profile measurement laser microscope, and wettability was evaluated by measuring the contact angle of a drop of water on the prepared dentin surface using an optical contact angle measuring device. The results showed that both laser fluence and PO had an effect on dentin surface roughness. Specifically, a higher PO decreased dentin surface roughness and reduced the effect of high-laser fluence on decreasing the surface roughness in some groups. Furthermore, all ablated dentin showed a contact angle of approximately 0 deg, meaning that laser ablation significantly improved wettability. Adjustment of ultrashort pulsed laser parameters can, therefore, significantly alter dentin surface roughness and wettability.


international conference on imaging systems and techniques | 2013

Evaluation of the accuracy of three-dimensional reconstruction of edentulous model jaw relation based on dental articulator positioning

Yuchun Sun; Hong Li; Fusong Yuan; Yijiao Zhao; Peijun Lü; Yong Wang

A dental articulator and three-dimensional (3D) scanner were utilized to reconstruct the spatial relationship between upper and lower edentulous jaw gypsum models made from five patients. The 7-axis Faro Edge contact measurement system was used to evaluate the vertical and horizontal distances between jaws. Paired t-test results of vertical distance (0.089±0.428 mm) and horizontal distance (-0.082±0.221 mm) between points on the jaws showed no significant differences (P>0.05). One-Way ANOVA of the same measurement data for the five models also showed no significant differences (P>0.05). With an error of less than 0.1 mm, these measurements met clinical requirements. In conclusion, 3D reconstruction of edentulous jaw gypsum models with accurate jaw relation was made possible by scanning the models in centric relation on a dental articulator.


Archive | 2009

Complete denture designing and manufacturing method based on CAD/RP technology

Peijun Lü; Yong Wang; Yuchun Sun


International Journal of Oral Science | 2013

Accuracy evaluation of a new three-dimensional reproduction method of edentulous dental casts, and wax occlusion rims with jaw relation

Fusong Yuan; Yuchun Sun; Yong Wang; Peijun Lü


Optics and Laser Technology | 2014

Effects of Yb:KYW thin-disk femtosecond laser ablation on enamel surface roughness

Jing Liu; Yuchun Sun; Yong Wang; Peijun Lü


Lasers in Medical Science | 2015

Wettability of dentin after Yb:KYW thin-disk femtosecond ablation

Jing Liu; Peijun Lü; Yuchun Sun; Yong Wang

Collaboration


Dive into the Peijun Lü's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wenqi Ge

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge