Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Peter Herberts is active.

Publication


Featured researches published by Peter Herberts.


Journal of Bone and Joint Surgery, American Volume | 2002

The Swedish Total Hip Replacement Register

Henrik Malchau; Peter Herberts; Thomas Eisler; Göran Garellick; Peter Söderman

Epidemiology of Primary and Revision Total Hip Replacement Introduction he Swedish Total Hip Replacement Register was initiated in 1979. The mission of the Register is to improve the outcome of total hip replacement (THR). Information technology development has substantially facilitated the possibility of fulfilling this mission. During the past three years, almost all information exchange between the reporting units and the Register has been provided via the Internet. Feedback to and reports from the participating units are effected through a specific website (www.jru.orthop.gu.se). The importance of the Register and its effect on quality improvement over time have been well documented. The hypothesis for the project is that feedback of analyzed data stimulates the individual clinic to reflect and improve according to the principle of the good example. The clinical and socioeconomic effects of the past twenty years of Register work have been striking, and almost fifty quality registries have been started in different medical fields in Sweden during the last decade.


Acta Orthopaedica Scandinavica | 1993

Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990.

Henrik Malchau; Peter Herberts; Lennart Ahnfelt

A prospective, national multi-center study of all reoperations after total hip replacement (THR) was started by the Swedish Orthopedic Association in 1979. The material comprises all THR performed in Sweden, presently more than 10,000 yearly or 130 THR per 100,000 inhabitants; uncemented implants have been used in less than 2 percent. The main reasons for revision have been aseptic loosening 79 percent, infection 10 percent, technical error 6 percent, and dislocation 2 percent. The cumulative rate of revision for deep infection has dropped from 0.9 percent to < 0.5 percent for implants inserted 1979 and 1983, respectively. With the Charnley prosthesis as the gold, standard the performance of other prostheses was analyzed. Improved cementation techniques and anti-infection measures have continuously reduced the revision risk. The register demonstrates that the average orthopedic surgeon cannot match the results achieved by experts. However, the vast majority of THR, worldwide, are not performed by experts. Quality-assurance in this sector of orthopedics demands a continuous analysis of the outcome of these operations.


Acta Orthopaedica Scandinavica | 2000

Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases

Peter Herberts; Henrik Malchau

The Swedish Hip Register has defined the epidemiology of total hip replacement in Sweden. Most hip implants are fully cemented. Serious complications and rates of revision have declined significantly despite an increasing number of patients at risk. During the past 5 years, only 8-9% of hip replacements are revisions. Aseptic loosening with or without osteolysis is the major problem and constitutes 71% of the revisions, but the incidence had decreased three times during the past 15 years to less than 3% at 10 years. The effectiveness of the surgical technique is the most important factor for reducing the risk of revision because of aseptic loosening, but choice of implant is also important. In practice, total hip replacement in Sweden has improved, as judged by information from this Register about individualized patient risks, implant safety, and the greater efficacy of surgical and cementing techniques.


Clinical Orthopaedics and Related Research | 1997

Radiostereometry of Hip Prostheses: Review of Methodology and Clinical Results

Johan Kärrholm; Peter Herberts; Peter Hultmark; Henrik Malchau; Bo Nivbrant; Jonas Thanner

Radiostereometric analysis is a science that enables reliable measurements to be made from radiographs. The method involves several steps including insertion of spheric tantalum markers, radiographic examinations, measurements of radiographic films, and calculations of three-dimensional movements. The precision of the method corresponding to the 99% significance interval varies between 0.15 and 0.6 mm and 0.3 degree and 2 degrees when applied to total hip replacement depending on the technique used. Measurements of implant micromovement during 1 to 2 years after surgery have proved to be of value to predict later clinical failure because of aseptic loosening and revision. Subsidence of the femoral stem or proximal migration of the acetabular cup between 1 and 2 mm has indicated increased risk of early or intermediate term revisions in those prosthetic designs studied so far. Minimum early migration has been recorded for clinically well documented nonpolished stems and polyethylene cups, which probably is one explanation for their long term success. This small amount of early micromotion also has been found in porous coated and screw fixated press fit cups and all hydroxyapatite coated designs hitherto studied. As a first step in a clinical evaluation of new implants or surgical techniques, the predictive value of radiostereometric analysis measurements can be used to reduce the number of patients exposed to the potential risk of clinical failure.


Journal of Bone and Joint Surgery, American Volume | 2006

Three Hundred and Twenty-one Periprosthetic Femoral Fractures

Hans Lindahl; Göran Garellick; Hans Regnér; Peter Herberts; Henrik Malchau

BACKGROUND The purpose of this study was to determine the demographics, incidence, and results of treatment of periprosthetic fractures in a nationwide observational study. METHODS In the years 1999 and 2000, 321 periprosthetic fractures were reported to the Swedish National Hip Arthroplasty Register. All of the associated hospital records were collected. At the time of follow-up, the Harris hip score, a health-related quality-of-life measure (the EuroQol-5D [EQ-5D] index), and patient satisfaction were used as outcome measurements. A radiologist performed the radiographic evaluation. RESULTS Ninety-one patients, with a mean age of 73.8 years, sustained a fracture after one or several revision procedures, and 230 patients, with a mean age of 77.9 years, sustained a fracture after a primary total hip replacement. Minor trauma, including a fall to the floor, and a spontaneous fracture were the main etiologies for the injuries. A high number of patients had a loose stem at the time of the fracture (66% in the primary replacement group and 51% in the revision group). Eighty-eight percent of the fractures were classified as Vancouver type B; however, there was difficulty with preoperative categorization of the fractures radiographically. There was a high failure rate resulting in a low short to mid-term prosthetic survival rate. The sixty-six-month survival rate for the entire fracture group, with reoperation as the end point, was 74.8% +/- 5.0%. One factor associated with fracture risk was implant design. CONCLUSIONS On the basis of these findings, we believe that high-risk patients should have routine radiographic follow-up. Such a routine could identify a loose implant and make intervention possible before a fracture occurred. Furthermore, we recommend an exploration of the joint to test the stability of the implant in patients with a Vancouver type-B fracture in which the stability of the stem is uncertain.


Acta Orthopaedica Scandinavica | 1995

Accuracy of migration analysis in hip arthroplasty Digitized and conventional radiography, compared to radiostereometry in 51 patients

Henrik Malchau; Johan Kärrholm; Yu Xing Wang; Peter Herberts

We assessed the accuracy of migration measurements on conventional and digitized radiographs of total hip arthroplasties by comparing the results with radiostereometry (RSA). 4 stem and 3 acetabular designs were studied. 2 of the stem designs and 1 cup design were uncemented. 180 manual and 202 digitized measurements were done on 120 conventional radiographic examinations. The readings on digitized radiographs did not differ from the manual measurements on the same radiographs. A comparison of the measurements from plain radiographs and with RSA of the femoral stems revealed an accuracy (absolute mean + 2 SD) of between 3.9 and 12.3 mm, depending on the choice of landmarks. The greatest accuracy was obtained by using tantalum markers inserted into the greater or the lesser trochanter and the shoulder of the stem. The most medial point of the lesser trochanter proved to be the best bony landmark. Measurements, including both the center of the femoral head and the greater trochanter, were associated with poor accuracy. The accuracy as regards horizontal cup migration varied from 4.4 to 6.5 mm and the accuracy as regards vertical migration varied between 4.4 and 6.3 mm. The intraobserver error (2 SD) ranged from 1.6 mm to 5.6 mm, The corresponding figures for the inter-observer error were 2.6 mm and 6.6 mm, respectively. One of the cemented cup designs was associated with inferior accuracy. Stem design did not affect the accuracy.


Clinical Orthopaedics and Related Research | 1997

How outcome studies have changed total hip arthroplasty practices in Sweden.

Peter Herberts; Henrik Malchau

The Swedish Hip Registry has defined the epidemiology of total hip replacement in Sweden. Most hip implants are fully cemented. Serious complications and rates of revision associated with total hip replacement have declined significantly despite an increasing number of patients at risk. During the past 5 years only 9% to 10% of hip replacement procedures are revision procedures. Aseptic loosening with or without osteolysis is the major problem and constitutes 73% of the revisions, but the incidence has decreased four times during the past 15 years to less than 3% at 10 years. Even septic complications can be prevented effectively. Demographics are important because male gender and young age increase the risk for revision because of aseptic loosening. Young female patients with rheumatoid arthritis and male patients with a previous hip fracture have five times higher revision rates than elderly patients. The quality of the surgical technique is the most important factor for reducing the risk for revision because of aseptic loosening, but choice of implant is also important. The variations among hospitals in type of surgical technique used is big enough to cause a 100% difference in revision rate for aseptic loosening. Total hip replacement practice in Sweden has improved based on information from this Registry about individualized patient risks, implant safety, and the efficacy of improving surgical and cementing techniques.


Clinical Orthopaedics and Related Research | 2004

The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis

Georgios Digas; Johan Kärrholm; Jonas Thanner; Henrik Malchau; Peter Herberts

The annual wear rate in polyethylene articulations should be 0.1 mm or less to avoid future osteolysis. Highly cross-linked polyethylene shows an 80 to 90% wear reduction in hip simulator testing, but the clinical documentation of this new polyethylene is still inadequate. We evaluated the highly cross-linked polyethylene in two prospective randomized clinical studies. Thirty-two patients (12 men, 20 women; 64 hips) with a median age of 48 years (range, 29-70 years) with bilateral primary or secondary arthrosis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked polyethylene on one side and conventional polyethylene on the other. Twenty-seven patients in this study have passed 2 years followup. A further group, comprised of 60 patients (61 hips) with a median age of 55 years (range, 35-70 years), was randomized to receive either highly cross-linked polyethylene or conventional cemented all-polyethylene of the same design. Forty-nine of these 60 patients have been observed for 3 years. In both studies all patients received Spectron stems with 28-mm Co-Cr heads. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured in the supine position from the first postoperative week, whereas standing examinations were initiated 3 months after the operation. The penetration rate almost was identical in the study and control groups at 6 months after the operation. Thereafter, the penetration rate leveled out in the two groups with highly cross-linked polyethylene. At 2 years the highly cross-linked polyethylene liner showed 62% lower proximal penetration and 31% lower total (three-dimensional) penetration when the patients were examined in supine position. The highly crosslinked all-polyethylene cemented cups showed lower proximal penetration in both positions. The better wear performance of highly cross-linked polyethylene could increase the implant longevity. Longer followup is needed to evaluate if this new material is associated with less occurrence of osteolysis.


Journal of Biomechanics | 1991

BIOMECHANICAL MODEL OF THE HUMAN SHOULDER JOINT-II. THE SHOULDER RHYTHM

Christian Högfors; Bo Peterson; Göran Sigholm; Peter Herberts

A method to investigate the rhythm of the human shoulder, i.e. the interplay between the motion of constituent parts of the shoulder, has been devised and tested. The method is based upon numerical evaluation of low dose roentgenstereophotogrammetric motion pictures of subjects equipped with radiation dense implantations in the bones. Evaluation of the method shows that it may be used in determining motion patterns and that the employed interpolation techniques can be used to simulate motions not actually performed in the laboratory. The shoulder rhythm has been previously poorly investigated and quantified results published pertain to one plane only. Our results on motion patterns correlate with previous investigations. With this method, we show that the absolute position of the bones varies significantly between individuals while the relative displacement of the bones during motion exhibit similarities. In particular the results show that, under normal conditions, the individual rhythm is very stable and insensitive to small hand-loads.


Acta Orthopaedica | 2007

5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts

Background Laboratory tests and early clinical studies have shown that highly cross-linked polyethylene (PE) markedly improves wear resistance compared to conventional PE. We evaluated this type of PE in two randomized clinical studies using radiostereometric analysis (RSA). The 2- and 3-year follow-up of these studies have already been reported. We found a lower penetration rate for the highly cross-linked PE than for conventional PE. We now report the outcome after 5 years. Patients and methods 60 patients (61 hips) with a median age of 55 years were randomized to receive either highly cross-linked PE (Durasul) or conventional cemented all-polyethylene sockets of the same design. 55 patients (56 hips) were followed for 5 years. In the second study, 32 patients (64 hips) with a median age of 48 years and with bilateral primary or secondary osteoarthritis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked PE (Longevity) on one side and conventional PE on the other. 23 patients in this study have passed the 5-year follow-up. Results Bedding-in and creep for the Durasul all-PE was reached by 2 years, and by 1 year for the Longevity liners. In both control groups with conventional PE, this was reached by 6 months. The steady-state wear rate was close to zero in the two study groups and 0.06 mm/ year for the conventional PE in the two control groups. Interpretation We found that use of highly crosslinked PE instead of conventional PE reduced the wear by more than 95%, which supports continued use of this type of PE in young, active patients.

Collaboration


Dive into the Peter Herberts's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jonas Thanner

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Lars Carlsson

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lars Regnér

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Christer Strömberg

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Christian Högfors

Chalmers University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge