Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Peter J. Grahn is active.

Publication


Featured researches published by Peter J. Grahn.


Frontiers in Neuroscience | 2014

A neurochemical closed-loop controller for deep brain stimulation: toward individualized smart neuromodulation therapies

Peter J. Grahn; Grant W. Mallory; Obaid U. Khurram; B. Michael Berry; Jan T. Hachmann; Allan J. Bieber; Kevin E. Bennet; Hoon Ki Min; Su Youne Chang; Kendall H. Lee; J. L. Lujan

Current strategies for optimizing deep brain stimulation (DBS) therapy involve multiple postoperative visits. During each visit, stimulation parameters are adjusted until desired therapeutic effects are achieved and adverse effects are minimized. However, the efficacy of these therapeutic parameters may decline with time due at least in part to disease progression, interactions between the host environment and the electrode, and lead migration. As such, development of closed-loop control systems that can respond to changing neurochemical environments, tailoring DBS therapy to individual patients, is paramount for improving the therapeutic efficacy of DBS. Evidence obtained using electrophysiology and imaging techniques in both animals and humans suggests that DBS works by modulating neural network activity. Recently, animal studies have shown that stimulation-evoked changes in neurotransmitter release that mirror normal physiology are associated with the therapeutic benefits of DBS. Therefore, to fully understand the neurophysiology of DBS and optimize its efficacy, it may be necessary to look beyond conventional electrophysiological analyses and characterize the neurochemical effects of therapeutic and non-therapeutic stimulation. By combining electrochemical monitoring and mathematical modeling techniques, we can potentially replace the trial-and-error process used in clinical programming with deterministic approaches that help attain optimal and stable neurochemical profiles. In this manuscript, we summarize the current understanding of electrophysiological and electrochemical processing for control of neuromodulation therapies. Additionally, we describe a proof-of-principle closed-loop controller that characterizes DBS-evoked dopamine changes to adjust stimulation parameters in a rodent model of DBS. The work described herein represents the initial steps toward achieving a “smart” neuroprosthetic system for treatment of neurologic and psychiatric disorders.


Frontiers in Neuroscience | 2014

Restoration of motor function following spinal cord injury via optimal control of intraspinal microstimulation: toward a next generation closed-loop neural prosthesis.

Peter J. Grahn; Grant W. Mallory; B. Michael Berry; Jan T. Hachmann; Darlene A. Lobel; J. Luis Lujan

Movement is planned and coordinated by the brain and carried out by contracting muscles acting on specific joints. Motor commands initiated in the brain travel through descending pathways in the spinal cord to effector motor neurons before reaching target muscles. Damage to these pathways by spinal cord injury (SCI) can result in paralysis below the injury level. However, the planning and coordination centers of the brain, as well as peripheral nerves and the muscles that they act upon, remain functional. Neuroprosthetic devices can restore motor function following SCI by direct electrical stimulation of the neuromuscular system. Unfortunately, conventional neuroprosthetic techniques are limited by a myriad of factors that include, but are not limited to, a lack of characterization of non-linear input/output system dynamics, mechanical coupling, limited number of degrees of freedom, high power consumption, large device size, and rapid onset of muscle fatigue. Wireless multi-channel closed-loop neuroprostheses that integrate command signals from the brain with sensor-based feedback from the environment and the systems state offer the possibility of increasing device performance, ultimately improving quality of life for people with SCI. In this manuscript, we review neuroprosthetic technology for improving functional restoration following SCI and describe brain-machine interfaces suitable for control of neuroprosthetic systems with multiple degrees of freedom. Additionally, we discuss novel stimulation paradigms that can improve synergy with higher planning centers and improve fatigue-resistant activation of paralyzed muscles. In the near future, integration of these technologies will provide SCI survivors with versatile closed-loop neuroprosthetic systems for restoring function to paralyzed muscles.


Mayo Clinic Proceedings | 2017

Enabling Task-Specific Volitional Motor Functions via Spinal Cord Neuromodulation in a Human With Paraplegia

Peter J. Grahn; Igor A. Lavrov; Dimitry G. Sayenko; Meegan G. Van Straaten; Megan L. Gill; Jeffrey A. Strommen; Jonathan S. Calvert; Dina I. Drubach; Lisa A. Beck; Margaux B. Linde; Andrew R. Thoreson; Cesar Lopez; Aldo A. Mendez; Parag Gad; Yury Gerasimenko; V. Reggie Edgerton; Kristin D. Zhao; Kendall H. Lee

Abstract We report a case of chronic traumatic paraplegia in which epidural electrical stimulation (EES) of the lumbosacral spinal cord enabled (1) volitional control of task‐specific muscle activity, (2) volitional control of rhythmic muscle activity to produce steplike movements while side‐lying, (3) independent standing, and (4) while in a vertical position with body weight partially supported, voluntary control of steplike movements and rhythmic muscle activity. This is the first time that the application of EES enabled all of these tasks in the same patient within the first 2 weeks (8 stimulation sessions total) of EES therapy.


PLOS ONE | 2013

Large animal model for development of functional restoration paradigms using epidural and intraspinal stimulation.

Jan T. Hachmann; Ju Ho Jeong; Peter J. Grahn; Grant W. Mallory; Loribeth Q. Evertz; Allan J. Bieber; Darlene A. Lobel; Kevin E. Bennet; Kendall H. Lee; J. Luis Lujan

Restoration of movement following spinal cord injury (SCI) has been achieved using electrical stimulation of peripheral nerves and skeletal muscles. However, practical limitations such as the rapid onset of muscle fatigue hinder clinical application of these technologies. Recently, direct stimulation of alpha motor neurons has shown promise for evoking graded, controlled, and sustained muscle contractions in rodent and feline animal models while overcoming some of these limitations. However, small animal models are not optimal for the development of clinical spinal stimulation techniques for functional restoration of movement. Furthermore, variance in surgical procedure, targeting, and electrode implantation techniques can compromise therapeutic outcomes and impede comparison of results across studies. Herein, we present a protocol and large animal model that allow standardized development, testing, and optimization of novel clinical strategies for restoring motor function following spinal cord injury. We tested this protocol using both epidural and intraspinal stimulation in a porcine model of spinal cord injury, but the protocol is suitable for the development of other novel therapeutic strategies. This protocol will help characterize spinal circuits vital for selective activation of motor neuron pools. In turn, this will expedite the development and validation of high-precision therapeutic targeting strategies and stimulation technologies for optimal restoration of motor function in humans.


The Spine Journal | 2014

Implantation of cauda equina nerve roots through a biodegradable scaffold at the conus medullaris in rat

Peter J. Grahn; Sandeep Vaishya; Andrew M. Knight; Bingkun K. Chen; Ann M. Schmeichel; Bradford L. Currier; Robert J. Spinner; Michael J. Yaszemski; Anthony J. Windebank

BACKGROUND CONTEXT Traumatic injuries occurring at the conus medullaris of the spinal cord cause permanent damage both to the central nervous system and to the cauda equina nerve roots. PURPOSE This proof-of-concept study was to determine whether implanting the nerve roots into a biodegradable scaffold would improve regeneration after injury. METHODS All experimental works involving rats were performed according to the approved guidelines by the Mayo Clinic Institutional Animal Care and Use Committee. Surgical procedures were performed on 32 Sprague-Dawley rats. Four ventral cauda equina nerve roots were reimplanted either directly into the ventral cord stump or through a poly(lactic-co-glycolic acid) (PLGA) scaffold. These experimental groups were compared with a control group in which the nerves were inserted into a muscle fascia barrier that was placed between the spinal cord and the nerve roots. Animals were sacrificed at 4 weeks. RESULTS There was no difference in motor neuron counts in the spinal cord rostral to the injury in all treatment groups, implying equal potential for the regeneration into implanted nerve roots. One-way analysis of variance testing, with Tukey post hoc test, showed a statistically significant improvement in axon regeneration through the injury in the PLGA scaffold treatment group compared with the control (p<.05, scaffold n=11, control n=11). CONCLUSIONS This pilot study demonstrated that a PLGA scaffold improved regeneration of axons into peripheral nerve roots. However, the number of regenerating axons observed was limited and did not lead to functional recovery. Future experiments will employ a different scaffold material and possible growth factors or enzymes to increase axon populations.


Spine | 2016

MRI-Guided Stereotactic System for Delivery of Intraspinal Microstimulation.

Peter J. Grahn; Stephan J. Goerss; J. L. Lujan; Grant W. Mallory; Bruce A. Kall; Aldo A. Mendez; James K. Trevathan; Joel P. Felmlee; Kevin E. Bennet; Kendall H. Lee

Study Design. Laboratory/animal-based proof of principle study. Objective. To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. Summary of Background Data. Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. Methods. System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. Results. The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ± 0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. Conclusion. We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. Level of Evidence: N/A


Journal of Neurosurgery | 2015

Wireless control of intraspinal microstimulation in a rodent model of paralysis

Peter J. Grahn; Kendall H. Lee; Aimen Kasasbeh; Grant W. Mallory; Jan T. Hachmann; John R. Dube; Christopher J. Kimble; Darlene A. Lobel; Allan J. Bieber; Ju H o Jeong; Kevin E. Bennet; J. Luis Lujan

OBJECT Despite a promising outlook, existing intraspinal microstimulation (ISMS) techniques for restoring functional motor control after spinal cord injury are not yet suitable for use outside a controlled laboratory environment. Thus, successful application of ISMS therapy in humans will require the use of versatile chronic neurostimulation systems. The objective of this study was to establish proof of principle for wireless control of ISMS to evoke controlled motor function in a rodent model of complete spinal cord injury. METHODS The lumbar spinal cord in each of 17 fully anesthetized Sprague-Dawley rats was stimulated via ISMS electrodes to evoke hindlimb function. Nine subjects underwent complete surgical transection of the spinal cord at the T-4 level 7 days before stimulation. Targeting for both groups (spinalized and control) was performed under visual inspection via dorsal spinal cord landmarks such as the dorsal root entry zone and the dorsal median fissure. Teflon-insulated stimulating platinum-iridium microwire electrodes (50 μm in diameter, with a 30- to 60-μm exposed tip) were implanted within the ventral gray matter to an approximate depth of 1.8 mm. Electrode implantation was performed using a free-hand delivery technique (n = 12) or a Kopf spinal frame system (n = 5) to compare the efficacy of these 2 commonly used targeting techniques. Stimulation was controlled remotely using a wireless neurostimulation control system. Hindlimb movements evoked by stimulation were tracked via kinematic markers placed on the hips, knees, ankles, and paws. Postmortem fixation and staining of the spinal cord tissue were conducted to determine the final positions of the stimulating electrodes within the spinal cord tissue. RESULTS The results show that wireless ISMS was capable of evoking controlled and sustained activation of ankle, knee, and hip muscles in 90% of the spinalized rats (n = 9) and 100% of the healthy control rats (n = 8). No functional differences between movements evoked by either of the 2 targeting techniques were revealed. However, frame-based targeting required fewer electrode penetrations to evoke target movements. CONCLUSIONS Clinical restoration of functional movement via ISMS remains a distant goal. However, the technology presented herein represents the first step toward restoring functional independence for individuals with chronic spinal cord injury.


Mayo Clinic Proceedings | 2015

Optical Stimulation for Restoration of Motor Function After Spinal Cord Injury

Grant W. Mallory; Peter J. Grahn; Jan T. Hachmann; J. Luis Lujan; Kendall H. Lee

Spinal cord injury can be defined as a loss of communication between the brain and the body due to disrupted pathways within the spinal cord. Although many promising molecular strategies have emerged to reduce secondary injury and promote axonal regrowth, there is still no effective cure, and recovery of function remains limited. Functional electrical stimulation (FES) represents a strategy developed to restore motor function without the need for regenerating severed spinal pathways. Despite its technological success, however, FES has not been widely integrated into the lives of spinal cord injury survivors. In this review, we briefly discuss the limitations of existing FES technologies. Additionally, we discuss how optogenetics, a rapidly evolving technique used primarily to investigate select neuronal populations within the brain, may eventually be used to replace FES as a form of therapy for functional restoration after spinal cord injury.


Nature Medicine | 2018

Neuromodulation of lumbosacral spinal networks enables independent stepping after complete paraplegia

Megan L. Gill; Peter J. Grahn; Jonathan S. Calvert; Margaux B. Linde; Igor A. Lavrov; Jeffrey A. Strommen; Lisa A. Beck; Dimitry G. Sayenko; Meegan G. Van Straaten; Dina I. Drubach; Daniel D. Veith; Andrew R. Thoreson; Cesar Lopez; Yury Gerasimenko; V. Reggie Edgerton; Kendall H. Lee; Kristin D. Zhao

Spinal sensorimotor networks that are functionally disconnected from the brain because of spinal cord injury (SCI) can be facilitated via epidural electrical stimulation (EES) to restore robust, coordinated motor activity in humans with paralysis1–3. Previously, we reported a clinical case of complete sensorimotor paralysis of the lower extremities in which EES restored the ability to stand and the ability to control step-like activity while side-lying or suspended vertically in a body-weight support system (BWS)4. Since then, dynamic task-specific training in the presence of EES, termed multimodal rehabilitation (MMR), was performed for 43 weeks and resulted in bilateral stepping on a treadmill, independent from trainer assistance or BWS. Additionally, MMR enabled independent stepping over ground while using a front-wheeled walker with trainer assistance at the hips to maintain balance. Furthermore, MMR engaged sensorimotor networks to achieve dynamic performance of standing and stepping. To our knowledge, this is the first report of independent stepping enabled by task-specific training in the presence of EES by a human with complete loss of lower extremity sensorimotor function due to SCI.In a human subject with chronic paraplegia, a combination of epidural electrical stimulation and long-term rehabilitative training have culminated in the first report of unassisted, voluntary independent stepping in a paralyzed individual.


Frontiers in Neuroanatomy | 2017

The role of functional neuroanatomy of the lumbar spinal cord in effect of epidural stimulation

Carlos A. Cuellar; Aldo A. Mendez; Riazul Islam; Jonathan S. Calvert; Peter J. Grahn; Bruce E. Knudsen; Tuan Pham; Kendall H. Lee; Igor A. Lavrov

In this study, the neuroanatomy of the swine lumbar spinal cord, particularly the spatial orientation of dorsal roots was correlated to the anatomical landmarks of the lumbar spine and to the magnitude of motor evoked potentials during epidural electrical stimulation (EES). We found that the proximity of the stimulating electrode to the dorsal roots entry zone across spinal segments was a critical factor to evoke higher peak-to-peak motor responses. Positioning the electrode close to the dorsal roots produced a significantly higher impact on motor evoked responses than rostro-caudal shift of electrode from segment to segment. Based on anatomical measurements of the lumbar spine and spinal cord, significant differences were found between L1-L4 to L5-L6 segments in terms of spinal cord gross anatomy, dorsal roots and spine landmarks. Linear regression analysis between intersegmental landmarks was performed and L2 intervertebral spinous process length was selected as the anatomical reference in order to correlate vertebral landmarks and the spinal cord structures. These findings present for the first time, the influence of spinal cord anatomy on the effects of epidural stimulation and the role of specific orientation of electrodes on the dorsal surface of the dura mater in relation to the dorsal roots. These results are critical to consider as spinal cord neuromodulation strategies continue to evolve and novel spinal interfaces translate into clinical practice.

Collaboration


Dive into the Peter J. Grahn's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge