Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Philipp Jungebluth is active.

Publication


Featured researches published by Philipp Jungebluth.


The Lancet | 2008

Clinical transplantation of a tissue-engineered airway

Paolo Macchiarini; Philipp Jungebluth; Tetsuhiko Go; M. Adelaide Asnaghi; Louisa Rees; Tristan A Cogan; Amanda L. Dodson; Jaume Martorell; Silvia Bellini; Pier Paolo Parnigotto; Sally C. Dickinson; Anthony P. Hollander; Sara Mantero; Maria Teresa Conconi; Martin A. Birchall

BACKGROUND The loss of a normal airway is devastating. Attempts to replace large airways have met with serious problems. Prerequisites for a tissue-engineered replacement are a suitable matrix, cells, ideal mechanical properties, and the absence of antigenicity. We aimed to bioengineer tubular tracheal matrices, using a tissue-engineering protocol, and to assess the application of this technology in a patient with end-stage airway disease. METHODS We removed cells and MHC antigens from a human donor trachea, which was then readily colonised by epithelial cells and mesenchymal stem-cell-derived chondrocytes that had been cultured from cells taken from the recipient (a 30-year old woman with end-stage bronchomalacia). This graft was then used to replace the recipients left main bronchus. FINDINGS The graft immediately provided the recipient with a functional airway, improved her quality of life, and had a normal appearance and mechanical properties at 4 months. The patient had no anti-donor antibodies and was not on immunosuppressive drugs. INTERPRETATION The results show that we can produce a cellular, tissue-engineered airway with mechanical properties that allow normal functioning, and which is free from the risks of rejection. The findings suggest that autologous cells combined with appropriate biomaterials might provide successful treatment for patients with serious clinical disorders.


The Lancet | 2011

Tracheobronchial transplantation with a stem-cell-seeded bioartificial nanocomposite: a proof-of-concept study

Philipp Jungebluth; Evren Alici; Silvia Baiguera; Katarina Le Blanc; Pontus Blomberg; Béla Bozóky; Claire Crowley; Oskar Einarsson; Karl-Henrik Grinnemo; Tomas Gudbjartsson; Sylvie Le Guyader; Gert Henriksson; Ola Hermanson; Jan Erik Juto; Bertil Leidner; Tobias Lilja; Jan Liska; Tom Luedde; Vanessa Lundin; Guido Moll; Bo Nilsson; Christoph Roderburg; Staffan Strömblad; Tolga Sutlu; Ana I. Teixeira; Emma Watz; Alexander M. Seifalian; Paolo Macchiarini

BACKGROUND Tracheal tumours can be surgically resected but most are an inoperable size at the time of diagnosis; therefore, new therapeutic options are needed. We report the clinical transplantation of the tracheobronchial airway with a stem-cell-seeded bioartificial nanocomposite. METHODS A 36-year-old male patient, previously treated with debulking surgery and radiation therapy, presented with recurrent primary cancer of the distal trachea and main bronchi. After complete tumour resection, the airway was replaced with a tailored bioartificial nanocomposite previously seeded with autologous bone-marrow mononuclear cells via a bioreactor for 36 h. Postoperative granulocyte colony-stimulating factor filgrastim (10 μg/kg) and epoetin beta (40,000 UI) were given over 14 days. We undertook flow cytometry, scanning electron microscopy, confocal microscopy epigenetics, multiplex, miRNA, and gene expression analyses. FINDINGS We noted an extracellular matrix-like coating and proliferating cells including a CD105+ subpopulation in the scaffold after the reseeding and bioreactor process. There were no major complications, and the patient was asymptomatic and tumour free 5 months after transplantation. The bioartificial nanocomposite has patent anastomoses, lined with a vascularised neomucosa, and was partly covered by nearly healthy epithelium. Postoperatively, we detected a mobilisation of peripheral cells displaying increased mesenchymal stromal cell phenotype, and upregulation of epoetin receptors, antiapoptotic genes, and miR-34 and miR-449 biomarkers. These findings, together with increased levels of regenerative-associated plasma factors, strongly suggest stem-cell homing and cell-mediated wound repair, extracellular matrix remodelling, and neovascularisation of the graft. INTERPRETATION Tailor-made bioartificial scaffolds can be used to replace complex airway defects. The bioreactor reseeding process and pharmacological-induced site-specific and graft-specific regeneration and tissue protection are key factors for successful clinical outcome. FUNDING European Commission, Knut and Alice Wallenberg Foundation, Swedish Research Council, StratRegen, Vinnova Foundation, Radiumhemmet, Clinigene EU Network of Excellence, Swedish Cancer Society, Centre for Biosciences (The Live Cell imaging Unit), and UCL Business.


The Lancet | 2014

The first tissue-engineered airway transplantation: 5-year follow-up results

Alessandro Gonfiotti; Massimo Osvaldo Jaus; Daniel Barale; Silvia Baiguera; Camilla E. Comin; Federico Lavorini; Giovanni A. Fontana; Oriol Sibila; Giovanni Rombolà; Philipp Jungebluth; Paolo Macchiarini

BACKGROUND In 2008, the first transplantation of a tissue-engineered trachea in a human being was done to replace an end-staged left main bronchus with malacia in a 30-year-old woman. We report 5 year follow-up results. METHODS The patient was followed up approximately every 3 months with multidetector CT scan and bronchoscopic assessment. We obtained mucosal biopsy samples every 6 months for histological, immunohistochemical, and electron microscopy assessment. We also assessed quality of life, respiratory function, cough reflex test, and production and specificity of recipient antibodies against donor human leucocyte antigen. FINDINGS By 12 months after transplantation, a progressive cicatricial stenosis had developed in the native trachea close to the tissue-engineered trachea anastomosis, which needed repeated endoluminal stenting. However, the tissue-engineered trachea itself remained open over its entire length, well vascularised, completely re-cellularised with respiratory epithelium, and had normal ciliary function and mucus clearance. Lung function and cough reflex were normal. No stem-cell-related teratoma formed and no anti-donor antibodies developed. Aside from intermittent bronchoscopic interventions, the patient had a normal social and working life. INTERPRETATION These clinical results provide evidence that a tissue-engineering strategy including decellularisation of a human trachea, autologous epithelial and stem-cell culture and differentiation, and cell-scaffold seeding with a bioreactor is safe and promising. FUNDING European Commission, Knut and Alice Wallenberg Foundation, Swedish Research Council, ALF Medicine.


Journal of extracellular vesicles | 2015

Extracellular vesicle in vivo biodistribution is determined by cell source, route of administration and targeting

Oscar P. B. Wiklander; Joel Z. Nordin; Aisling O'Loughlin; Ylva Gustafsson; Giulia Corso; Imre Mäger; Pieter Vader; Yi Lee; Helena Sork; Yiqi Seow; Nina Heldring; Lydia Alvarez-Erviti; C. I. Edvard Smith; Katarina Le Blanc; Paolo Macchiarini; Philipp Jungebluth; Matthew J.A. Wood; Samir El Andaloussi

Extracellular vesicles (EVs) have emerged as important mediators of intercellular communication in a diverse range of biological processes. For future therapeutic applications and for EV biology research in general, understanding the in vivo fate of EVs is of utmost importance. Here we studied biodistribution of EVs in mice after systemic delivery. EVs were isolated from 3 different mouse cell sources, including dendritic cells (DCs) derived from bone marrow, and labelled with a near-infrared lipophilic dye. Xenotransplantation of EVs was further carried out for cross-species comparison. The reliability of the labelling technique was confirmed by sucrose gradient fractionation, organ perfusion and further supported by immunohistochemical staining using CD63-EGFP probed vesicles. While vesicles accumulated mainly in liver, spleen, gastrointestinal tract and lungs, differences related to EV cell origin were detected. EVs accumulated in the tumour tissue of tumour-bearing mice and, after introduction of the rabies virus glycoprotein-targeting moiety, they were found more readily in acetylcholine-receptor-rich organs. In addition, the route of administration and the dose of injected EVs influenced the biodistribution pattern. This is the first extensive biodistribution investigation of EVs comparing the impact of several different variables, the results of which have implications for the design and feasibility of therapeutic studies using EVs.


The Journal of Thoracic and Cardiovascular Surgery | 2010

Both epithelial cells and mesenchymal stem cell-derived chondrocytes contribute to the survival of tissue-engineered airway transplants in pigs.

Tetsuhiko Go; Philipp Jungebluth; Silvia Baiguero; Adelaide Asnaghi; Jaume Martorell; Helmut Ostertag; Sara Mantero; Martin A. Birchall; Augustinus Bader; Paolo Macchiarini

OBJECTIVE We sought to determine the relative contributions of epithelial cells and mesenchymal stem cell-derived chondrocytes to the survival of tissue-engineered airway transplants in pigs. METHODS Nonimmunogenic tracheal matrices were obtained by using a detergent-enzymatic method. Major histocompatibility complex-unmatched animals (weighing 65 +/- 4 kg) were divided into 4 groups (each n = 5), and 6 cm of their tracheas were orthotopically replaced with decellularized matrix only (group I), decellularized matrix with autologous mesenchymal stem cell-derived chondrocytes externally (group II), decellularized matrix with autologous epithelial cells internally (group III), or decellularized matrix with both cell types (group IV). Autologous cells were recovered, cultured, and expanded. Mesenchymal stem cells were differentiated into chondrocytes by using growth factors. Both cell types were seeded simultaneously with a dual-chamber bioreactor. Animals were not immunosuppressed during the entire study. Biopsy specimens and blood samples were taken from recipients continuously, and animals were observed for a maximum of 60 days. RESULTS Matrices were completely covered with both cell types within 72 hours. Survival of the pigs was significantly affected by group (P < .05; group I, 11 +/- 2 days; group II, 29 +/- 4 days; group III, 34 +/- 4 days; and group IV, 60 +/- 1 days). Cause of death was a combination of airway obstruction and infection (group I), mainly infection (group II), or primarily stenosis (group III). However, pigs in group IV were alive, with no signs of airway collapse or ischemia and healthy epithelium. There were no clinical, immunologic, or histologic signs of rejection despite the lack of immunosuppression. CONCLUSIONS We confirm the clinical potential of autologous cell- and tissue-engineered tracheal grafts, and suggest that the seeding of both epithelial and mesenchymal stem cell-derived chondrocytes is necessary for optimal graft survival.


Clinical Pharmacology & Therapeutics | 2012

Tissue‐Engineered Airway: A Regenerative Solution

Philipp Jungebluth; Guido Moll; Silvia Baiguera; Paolo Macchiarini

The use of synthetic degradable or permanent polymers and biomaterials has not yet helped to achieve successful clinical whole‐airway replacement. A novel, clinically successful approach involves tissue engineering (TE) replacement using three‐dimensional biologic scaffolds composed of allogeneic extracellular scaffolds derived from nonautologous sources and recellularized with autologous stem cells or differentiated cells. In this paper, we discuss this novel approach and review information that can lead to a better understanding of stem cell recruitment and/or mobilization and site‐specific tissue protection, which can be pharmacologically boosted in humans.


Biomaterials | 2012

The concept of in vivo airway tissue engineering.

Philipp Jungebluth; Augustinus Bader; Silvia Baiguera; Susanne Möller; Massimo Osvaldo Jaus; Mei Ling Lim; Kaj Fried; Kristín Rós Kjartansdóttir; Tetsuhiko Go; Heike Nave; Wolfgang Harringer; Vanessa Lundin; Ana I. Teixeira; Paolo Macchiarini

We investigated whether decellularized pig tracheas could regenerate in vivo, without being recellularized before transplantation, using the own body as bioreactor. Decellularized pig tracheal scaffolds were intraoperative conditioned with mononuclear cells and growth and differentiation factors. During the postoperative period, the in situ regeneration was boosted by administering bioactive molecules to promote peripheral mobilization and differentiation of stem/progenitor cells and ultimately the regenerative process. Results revealed, after 2 weeks, a nearly normal trachea, with respiratory epithelium and a double-banded cartilage but without any mechanical differences compared to the native tissue. The growth factor administration resulted in a mobilization of progenitor and stem cells into the peripheral circulation and in an up-regulation of anti-apoptotic genes. Isolated stem/progenitor cells could be differentiated in vitro into several cell types, proving their multipotency. We provide evidence that the own body can be used as bioreactor to promote in vivo tissue engineering replacement. Moreover, we demonstrated the beneficial effect of additional pharmaceutical intervention for an improved engraftment of the transplant.


Biomaterials | 2012

Biomechanical and angiogenic properties of tissue-engineered rat trachea using genipin cross-linked decellularized tissue

Johannes C. Haag; Silvia Baiguera; Philipp Jungebluth; Daniel Barale; Costantino Del Gaudio; Francesca Castiglione; Alessandra Bianco; Camilla E. Comin; Domenico Ribatti; Paolo Macchiarini

In this study, the obtainment and characterization of decellularized rat tracheal grafts are described. The detergent-enzymatic method, already used to develop bioengineered pig and human trachea scaffolds, has been applied to rat tracheae in order to obtain airway grafts suitable to be used to improve our knowledge on the process of tissue-engineered airway transplantation and regeneration. The results demonstrated that, after 9 detergent-enzymatic cycles, almost complete decellularized tracheae, retaining the hierarchical and mechanical properties of the native tissues with strong in vivo angiogenic characteristics, could be obtained. Moreover, to improve the mechanical properties of decellularized tracheae, genipin is here considered as a naturally derived cross-linking agent. The results demonstrated that the treatment increased mechanical properties, in term of secant modulus, without neither altering the pro-angiogenic properties of decellularized airway matrices or eliciting an in vivo inflammatory response.


Biomaterials | 2012

Viability and proliferation of rat MSCs on adhesion protein-modified PET and PU scaffolds

Ylva Gustafsson; Johannes C. Haag; Philipp Jungebluth; Vanessa Lundin; Mei Ling Lim; Silvia Baiguera; Fatemeh Ajalloueian; Costantino Del Gaudio; Alessandra Bianco; Guido Moll; Sebastian Sjöqvist; Greg Lemon; Ana I. Teixeira; Paolo Macchiarini

In 2011, the first in-man successful transplantation of a tissue engineered trachea-bronchial graft, using a synthetic POSS-PCU nanocomposite construct seeded with autologous stem cells, was performed. To further improve this technology, we investigated the feasibility of using polymers with a three dimensional structure more closely mimicking the morphology and size scale of native extracellular matrix (ECM) fibers. We therefore investigated the in vitro biocompatibility of electrospun polyethylene terephthalate (PET) and polyurethane (PU) scaffolds, and determined the effects on cell attachment by conditioning the fibers with adhesion proteins. Rat mesenchymal stromal cells (MSCs) were seeded on either PET or PU fiber-layered culture plates coated with laminin, collagen I, fibronectin, poly-D-lysine or gelatin. Cell density, proliferation, viability, morphology and mRNA expression were evaluated. MSC cultures on PET and PU resulted in similar cell densities and amounts of proliferating cells, with retained MSC phenotype compared to data obtained from tissue culture plate cultures. Coating the scaffolds with adhesion proteins did not increase cell density or cell proliferation. Our data suggest that both PET and PU mats, matching the dimensions of ECM fibers, are biomimetic scaffolds and, because of their high surface area-to-volume provided by the electrospinning procedure, makes them per se suitable for cell attachment and proliferation without any additional coating.


Biomaterials | 2014

Biomechanical and biocompatibility characteristics of electrospun polymeric tracheal scaffolds.

Fatemeh Ajalloueian; Mei Ling Lim; Greg Lemon; Johannes C. Haag; Ylva Gustafsson; Sebastian Sjöqvist; Antonio Beltrán-Rodríguez; Costantino Del Gaudio; Silvia Baiguera; Alessandra Bianco; Philipp Jungebluth; Paolo Macchiarini

The development of tracheal scaffolds fabricated based on electrospinning technique by applying different ratios of polyethylene terephthalate (PET) and polyurethane (PU) is introduced here. Prior to clinical implantation, evaluations of biomechanical and morphological properties, as well as biocompatibility and cell adhesion verifications are required and extensively performed on each scaffold type. However, the need for bioreactors and large cell numbers may delay the verification process during the early assessment phase. Hence, we investigated the feasibility of performing biocompatibility verification using static instead of dynamic culture. We performed bioreactor seeding on 3-dimensional (3-D) tracheal scaffolds (PET/PU and PET) and correlated the quantitative and qualitative results with 2-dimensional (2-D) sheets seeded under static conditions. We found that an 8-fold reduction for 2-D static seeding density can essentially provide validation on the qualitative and quantitative evaluations for 3-D scaffolds. In vitro studies revealed that there was notably better cell attachment on PET sheets/scaffolds than with the polyblend. However, the in vivo outcomes of cell seeded PET/PU and PET scaffolds in an orthotopic transplantation model in rodents were similar. They showed that both the scaffold types satisfied biocompatibility requirements and integrated well with the adjacent tissue without any observation of necrosis within 30 days of implantation.

Collaboration


Dive into the Philipp Jungebluth's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alessandra Bianco

University of Rome Tor Vergata

View shared research outputs
Top Co-Authors

Avatar

Costantino Del Gaudio

University of Rome Tor Vergata

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge