Priscila Fernanda da Silveira
Universidade Federal do Rio Grande do Sul
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Priscila Fernanda da Silveira.
Dental Traumatology | 2013
Priscila Fernanda da Silveira; Mariana Boessio Vizzotto; Gabriela Salatino Liedke; Heraldo Luis Dias da Silveira; Francisco Montagner; Heloísa Emília Dias da Silveira
OBJECTIVES This study compared the ability of conventional radiographic and cone beam computed tomography (CBCT) examinations to detect vertical root fractures (VRF) in teeth with or without root canal treatment and metallic posts. Furthermore, the influence of using different voxel sizes from CBCT images was assessed. METHODOLOGY Sixty single-rooted human teeth were randomly divided into two groups: experimental and control. Twenty teeth were endodontically prepared and obturated with gutta-percha, twenty had a metallic postcemented after the filling, and twenty had no preparation. The teeth from the experimental group were fractured. All teeth were radiographed with three different horizontal angles, and after, CBCT images were acquired following three protocols in which the variation was the voxel resolution (0.4, 0.3, and 0.2 mm). Three calibrated examiners assessed the images. RESULTS Chi-squared test showed no statistical difference among the images in detecting VRFs. The results of the diagnostic performance tests presented similar ability to detect VRFs when conventional radiographic examination was compared with 0.2 and 0.3-voxel CBCTs scans, in roots without endodontic treatment and metallic post. Moreover, specificity, sensitivity, and accuracy findings were similar for both 0.2 and 0.3-voxel resolution scans for teeth that are not root filled. However, it was observed that in teeth with root canal treatment and a post, the accuracy was higher when 0.2-mm voxel resolution was used. CONCLUSION The radiographic examination with horizontal angle variation should be encouraged as the first complementary approach to assess the presence of VRFs. If conventional imaging is not capable to provide adequate information, CBCT can be indicated if a root fracture is strongly suspected. The root condition should then guide the voxel resolution choice, selecting 0.3-voxel for not root filled teeth and 0.2-voxel for teeth with filling and/or a post.
Journal of Endodontics | 2014
Priscila Fernanda da Silveira; Mariana Boessio Vizzotto; Francisco Montagner; Heraldo Luis Dias da Silveira; Heloísa Emília Dias da Silveira
INTRODUCTION Studies to evaluate the diagnostic power of imaging examinations to detect root resorption have been based on simulations produced by burs. Standardized, round, and well-outlined access cavities do not reproduce the characteristics of physiological lesions and may facilitate diagnosis, masking the true accuracy of imaging techniques. A methodology to simulate internal root resorption by using acid demineralization was developed. METHODS Eleven extracted single-rooted teeth were mesiodistally sectioned into homologous halves. Root canals were labeled to ensure restricted and controlled action of fluids. The protocol was composed of 24-hour cycles (5% nitric acid for 12 hours, rinsing with deionized water, and 8% sodium hypochlorite for 10 minutes). At the end of each cycle 1 tooth was removed from treatment, defining an exposure time that cumulated to the last tooth. Electron microscopy imaging was assessed to determine lesion area and depth. RESULTS Minimum and maximum and areas and depths were 3.14 mm² and 10.34 mm² and 0.22 mm and 1.59 mm, respectively. Resorption simulated by the protocol proposed reproduced lesions of different sizes. CONCLUSIONS The irregular shape and larger diameter:depth ratio suggest that these lesions are more similar to in vivo internal root resorption, compared with bur-induced lesions.
Journal of Oral and Maxillofacial Radiology | 2014
Gainer R. Jasa; Mariana Boessio Vizzotto; Priscila Fernanda da Silveira; Heloísa Emília Dias da Silveira; Heraldo Luis Dias da Silveira; Leticia Ruhland Correa; Tabare Raveca
Aim: The aim of this study was to evaluate the use of lateral oblique radiography (LOR) at two different incidence angles for the bucco-lingual topographic localization of the mandibular canal with respect to the lower third molars. Materials And Method: A total of 24 dry jaws bearing at least one third molar were subject to LOR at vertical incidence angles of 0° and -30°. A trained and calibrated examiner measured the distance between the top of the mandibular canal to the most apical point of the third molar, using a digital calliper and individual light box for the radiographs. Based on the analysis of the two measurements (incidence angles of 0° and -30°) and considering the buccal object rule, the observer estimated the location of the mandibular canal, which was classified as lingual, central or buccal to the corresponding third molar. Results were compared with the computerized tomography images (gold standard). Results: The statistical analysis included sensitivity, specificity and accuracy tests. These results showed that LOR (0° e -30°) could be used to determine the bucco-lingual location of the mandibular canal with respect to the third molar. Conclusion: In spite of the magnification, LOR images demonstrated that the technique could be used for this study proposal.
Dentomaxillofacial Radiology | 2017
Michele Machado Vidor; Gabriela Salatino Liedke; Mariana Boessio Vizzotto; Heraldo Luis Dias da Silveira; Priscila Fernanda da Silveira; Cristiano W Araujo; Heloísa Emília Dias da Silveira
OBJECTIVES To analyze the diagnostic accuracy of conventional and digital radiographic images and the impact of digital filters in evaluating the bone-implant interface. METHODS Titanium implants were inserted into 74 fresh bovine ribs blocks, 37 fitting tight to the bone walls (simulating the existence of osseointegration) and 37 with a gap of 0.125 mm (simulating a failure in the osseointegration process). Periapical radiographs were taken with conventional film and two phosphor plate systems [VistaScan® (Dürr Dental, Bietigheim-Bissingen, Germany) and Express® (Instrumentarium, Tuusula, Finland)]. Digital radiographs were investigated with and without enhancement filters. Three blinded examiners assessed the images for the presence of juxtaposition in the bone-implant interface using a five-point Likert scale. Sensitivity, specificity and the area under the receiver-operating characteristic curve (AUC) and its 95% confidence interval (CI) were calculated for each variable. Intraexaminer and interexaminer agreements were analyzed using Kendalls concordance test. RESULTS Intraexaminer and interexaminer agreements were >0.80 for both digital and conventional images. Conventional radiographs (AUC = 0.963/CI = 0.891 to 0.993) and digital images with high enhancement filters such as Caries2 (AUC = 0.964/CI = 0.892 to 0.993), Endo (AUC = 0.952/CI = 0.875 to 0.988) and Sharpen3 (AUC = 0.894/CI = 0.801 to 0.954) showed the greatest accuracy for evaluating the bone-implant interface. Original images from both digital systems and the further enhancement filters tested showed low sensitivity for the diagnosis task tested. CONCLUSIONS Conventional radiographs or digital radiographs with high-pass filters could help enhance diagnosis on implant-bone interface.
European Journal of Orthodontics | 2018
Luize Severo Martins; Gabriela Salatino Liedke; Heraldo Luis Dias da-Silveira; Priscila Fernanda da Silveira; Nádia Assein Arús; E.M. Ongkosuwito; Mariana Boessio Vizzotto
Objectives No consensus exists on the assessment of airway in CBCT scans. Two-dimensional measures remain the standard in the cephalometric analysis. This research aimed to evaluate linear and area measurements in two-dimensional views from specific airway regions of interest and compare these to the correspondent volume in CBCT exams. Materials and Methods 250-selected CBCT scans were retrospectively analyzed. A trained and calibrated examiner performed the linear, area and volume measurements in specific sites for nasal cavity, nasopharynx and oropharynx compartments. Dolphin Software was used for the analysis. The correlations were performed using Pearson coefficient. Results The highest positive correlations were observed in the nasopharynx and oropharynx sagittal areas and the most constricted area in the oropharynx. Nasopharynx linear measures and nasopharynx coronal area did not present correlation with whole volume. Two-dimensional measurements in the soft palate (width and sagittal area) showed very low positive correlations. Although nasal cavity presented highest volume means, changes in oropharynx contributed more to variations in total volume, compared with the other two sections. Conclusion Airway sagittal areas, as well as the most constricted axial area in oropharynx remains a useful guide to correlate with airway volume in two-dimensional images.
Oral Radiology | 2015
Mariana Boessio Vizzotto; Priscila Fernanda da Silveira; Gabriela Salatino Liedke; Nádia Assein Arús; Francisco Montagner; Heraldo Luis Dias da Silveira; Heloísa Emília Dias da Silveira
ObjectivesThe use of cone-beam computed tomography (CBCT) in endodontics includes the assessment of endodontic pathologies, presurgical planning, and canal morphology. The performance of CBCT scans to observe pathologic conditions and anatomic structures in three-dimensional reconstructions has proven to be incredibly useful. The quality of the images, the conditions for their analysis, and the operator’s skill and care during the image acquisition strongly affect the incidence of diagnostic errors. In the same way, the validity of any test for diagnosis depends on its reliability. The purpose of this study was to assess the ability of three observers to accurately confirm the existence and absence of MB2 canals in human first upper molars with different root conditions.MethodsThree trained and calibrated dentists from a postgraduate program on oral and maxillofacial radiology were asked to identify MB2 canals in 82 extracted human first upper molars under different conditions depending on the MB1 root canal (non-filled, filled, and deobturated). Kappa values among the observers were obtained.ResultsThe agreement among the examiners ranged from 0.39 to 0.68. The kappa values were more impaired by the root condition than by the voxel size. Moreover, experience in CBCT image evaluation played a role in agreement among the examiners.ConclusionsThe results suggest that root condition and professional experience have more influence for agreement during MB2 diagnosis than voxel size.
Dental Press Endodontics | 2014
Lisangela da Silva; Priscila Fernanda da Silveira; Mariana Boessio Vizzotto; Gabriela Salatino Liedke; Heraldo Luis Dias da Silveira; Heloísa Emília Dias da Silveira
Introduction: Intraoral radiographs are an important investigative aid in the detection of endodontic injuries, including vertical root fractures (VRF). Objective: The objective of this study was to assess the capacity of orthogonal and angulated conventional as well as digital radiographs to detect VRF in teeth under different root conditions. Methods: Sixty teeth were divided into three groups according to the canal condition: non-filled, filled with gutta-percha and filled with gutta-percha and metallic post. Ten teeth in each group were artificially fractured, whereas teeth in the control group were not fractured. Orthogonal and horizontally angulated conventional film (Kodak) and digital phosphor plate (VistaScan Durr Dental) were used. Three blinded and calibrated observers carried out evaluations at four different time intervals. Modal values were used to calculate sensibility, specificity and accuracy. The area under the ROC curve (aucROC) and confidence intervals (CI) was used to compare the performance between radiographic systems, as well as the influence of combined angulated images. Results: Angulated radiographs showed larger aucROC for both conventional and digital images. CI revealed statistically significant differences between conventional orthogonal and digital angulated radiographs (CI: 0.403 – 0.697 and 0.767 – 0.967, respectively). Moreover, when only orthogonal incidences were considered, digital radiographs yielded better results than the conventional ones (CI: 0.403 – 0.697 and 0.622 – 0.878, respectively). Conclusion: The strong inclination towards yielding better diagnostic test results provided by digital radiographs suggests that the digital system using angulated projections is more appropriate to investigate VRF than the conventional one.
International Endodontic Journal | 2013
MarianaBoessio Vizzotto; Priscila Fernanda da Silveira; N. A. Arús; Francisco Montagner; B. P. F. A. Gomes; H. E. D. da Silveira
Journal of Prosthetic Dentistry | 2015
Gabriela Salatino Liedke; Rubens Spin-Neto; Mariana Boessio Vizzotto; Priscila Fernanda da Silveira; Heloísa Emília Dias da Silveira; Ann Wenzel
Oral Surgery, Oral Medicine, Oral Pathology, and Oral Radiology | 2015
Gabriela Salatino Liedke; Rubens Spin-Neto; Mariana Boessio Vizzotto; Priscila Fernanda da Silveira; Ann Wenzel; Heloísa Emília Dias da Silveira
Collaboration
Dive into the Priscila Fernanda da Silveira's collaboration.
Luciana Russowsky Bragagnolo Dutra
Universidade Federal do Rio Grande do Sul
View shared research outputs