Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where R.M.D. Meek is active.

Publication


Featured researches published by R.M.D. Meek.


Journal of Bone and Joint Surgery-british Volume | 2011

The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement

R.M.D. Meek; T. Norwood; R. Smith; Ivan J. Brenkel; Colin R. Howie

Peri-prosthetic fracture after joint replacement in the lower limb is associated with significant morbidity. The primary aim of this study was to investigate the incidence of peri-prosthetic fracture after total hip replacement (THR) and total knee replacement (TKR) over a ten-year period using a population-based linked dataset. Between 1 April 1997 and 31 March 2008, 52,136 primary THRs, 8726 revision THRs, 44,511 primary TKRs, and 3222 revision TKRs were performed. Five years post-operatively, the rate of fracture was 0.9% after primary THR, 4.2% after revision THR, 0.6% after primary TKR and 1.7% after revision TKR. Comparison of survival analysis for all primary and revision arthroplasties showed peri-prosthetic fractures were more likely in females, patients aged > 70 and after revision arthroplasty. Female patients aged > 70 should be warned of a significantly increased risk of peri-prosthetic fracture after hip or knee replacement. The use of adjuvant medical treatment to reduce the effect of peri-prosthetic osteoporosis may be a direction of research for these patients.


Journal of Bone and Joint Surgery-british Volume | 2011

Lower rates of dislocation with increased femoral head size after primary total hip replacement: A FIVE-YEAR ANALYSIS OF NHS PATIENTS IN ENGLAND

Simon S. Jameson; D. Lees; Philip James; Ignacio Serrano-Pedraza; Paul Partington; Scott D. Muller; R.M.D. Meek; M. R. Reed

Increased femoral head size may reduce dislocation rates following total hip replacement. The National Joint Registry for England and Wales has highlighted a statistically significant increase in the use of femoral heads ≥ 36 mm in diameter from 5% in 2005 to 26% in 2009, together with an increase in the use of the posterior approach. The aim of this study was to determine whether rates of dislocation have fallen over the same period. National data for England for 247 546 procedures were analysed in order to determine trends in the rate of dislocation at three, six, 12 and 18 months after operation during this time. The 18-month revision rates were also examined. Between 2005 and 2009 there were significant decreases in cumulative dislocations at three months (1.12% to 0.86%), six months (1.25% to 0.96%) and 12 months (1.42% to 1.11%) (all p < 0.001), and at 18 months (1.56% to 1.31%) for the period 2005 to 2008 (p < 0.001). The 18-month revision rates did not significantly change during the study period (1.26% to 1.39%, odds ratio 1.10 (95% confidence interval 0.98 to 1.24), p = 0.118). There was no evidence of changes in the coding of dislocations during this time. These data have revealed a significant reduction in dislocations associated with the use of large femoral head sizes, with no change in the 18-month revision rate.


Journal of Bone and Joint Surgery-british Volume | 2010

Electrocautery of the patellar rim in primary total knee replacement: beneficial or unnecessary?

S. Gupta; A. Augustine; L. Horey; R.M.D. Meek; M. G. Hullin; A. Mohammed

The management of the patella during total knee replacement is controversial. In some studies the absence of patellar resurfacing results in residual anterior knee pain in over 10% of patients. One form of treatment which may be used in an endeavour to reduce this is circumferential patellar rim electrocautery. This is believed to partially denervate the patella. However, there is no evidence of the efficacy of this procedure, nor do we know if it results in harm. A retrospective comparative cohort study was performed of 192 patients who had undergone a primary total knee replacement with the porous coated Low Contact Stress rotating platform prosthesis without patellar resurfacing between 2003 and 2007. In 98 patients circumferential electrocautery of the patellar rim was performed and in 94 patients it was not. The two groups were matched for gender and age. The general Oxford Knee Score and the more specific patellar score for anterior knee pain were used to assess patient outcomes a minimum of two years post-operatively. No statistically significant differences were noted between the groups for either scoring system (p = 0.41 and p = 0.87, respectively). Electrocautery of the patella rim did not improve the outcome scores after primary total knee replacement in our patients.


Bone and Joint Research | 2014

Practical considerations for volumetric wear analysis of explanted hip arthroplasties

Dj Langton; R. P. Sidaginamale; James P. Holland; David J. Deehan; T. J. Joyce; A. V. F. Nargol; R.M.D. Meek; James Lord

Objectives Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena. Methods We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study. Results Various scanning parameters including point pitch, maximum point to point distance, the number of scanning contours or the total number of points had no clinically relevant effect on volumetric wear calculations. Gravimetric testing showed that material loss can be calculated to provide clinically relevant degrees of accuracy. Conclusions Prosthetic surfaces can be analysed accurately and rapidly with currently available technologies. Given these results, we believe that routine analysis of explanted hip components would be a feasible and logical extension to National Joint Registries. Cite this article: Bone Joint Res 2014;3:60–8.


Bone and Joint Research | 2013

Reducing surgical site infection in arthroplasty of the lower limb: A multi-disciplinary approach

R. Johnson; Simon S. Jameson; R. D. Sanders; N. J. Sargant; S. D. Muller; R.M.D. Meek; M. R. Reed

Objectives To review the current best surgical practice and detail a multi-disciplinary approach that could further reduce joint replacement infection. Methods Review of relevant literature indexed in PubMed. Results Surgical site infection is a major complication following arthroplasty. Despite its rarity in contemporary orthopaedic practice, it remains difficult to treat and is costly in terms of both patient morbidity and long-term health care resources. Conclusions Emphasis on education of patients and all members of the health-care team and raising awareness in how to participate in preventative efforts is imperative.


Scottish Medical Journal | 2009

Direct to Consumer Advertising via the Internet, a Study of Hip Resurfacing

B Ogunwale; Jon Clarke; David Young; A. Mohammed; Sanjeev Patil; R.M.D. Meek

Background and Aims With increased use of the internet for health information and direct to consumer advertising from medical companies, there is concern about the quality of information available to patients. The aim of this study was to examine the quality of health information on the internet for hip resurfacing. Methods An assessment tool was designed to measure quality of information. Websites were measured on credibility of source; usability; currentness of the information; content relevance; content accuracy/completeness and disclosure/bias. Each website assessed was given a total score, based on number of scores achieved from the above categories websites were further analysed on author, geographical origin and possession of an independent credibility check. Results There was positive correlation between the overall score for the website and the score of each website in each assessment category. Websites by implant companies, doctors and hospitals scored poorly. Websites with an independent credibility check such as Health on the Net (HoN) scored twice the total scores of websites without. Conclusions Like other internet health websites, the quality of information on hip resurfacing websites is variable. This study highlights methods by which to assess the quality of health information on the internet and advocates that patients should look for a statement of an “independent credibility check” when searching for information on hip resurfacing.


Journal of Bone and Joint Surgery-british Volume | 2015

Inactivation of micro-organisms isolated from infected lower limb arthroplasties using high-intensity narrow-spectrum (HINS) light

S. Gupta; Michelle Maclean; J.G. Anderson; S.J. MacGregor; R.M.D. Meek; M.H. Grant

High-intensity narrow-spectrum (HINS) light is a novel violet-blue light inactivation technology which kills bacteria through a photodynamic process, and has been shown to have bactericidal activity against a wide range of species. Specimens from patients with infected hip and knee arthroplasties were collected over a one-year period (1 May 2009 to 30 April 2010). A range of these microbial isolates were tested for sensitivity to HINS-light. During testing, suspensions of the pathogens were exposed to increasing doses of HINS-light (of 123mW/cm(2) irradiance). Non-light exposed control samples were also used. The samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration. Complete inactivation (greater than 4-log10 reduction) was achieved for all of the isolates. The typical inactivation curve showed a slow initial reaction followed by a rapid period of inactivation. The doses of HINS-light required ranged between 118 and 2214 J/cm(2). Gram-positive bacteria were generally found to be more susceptible than Gram-negative. As HINS-light uses visible wavelengths, it can be safely used in the presence of patients and staff. This unique feature could lead to its possible use in the prevention of infection during surgery and post-operative dressing changes. Cite this article: Bone Joint J 2015;97-B:283-8.


Journal of Bone and Joint Surgery-british Volume | 2011

A randomised study of peri-prosthetic bone density after cemented versus trabecular fixation of a polyethylene acetabular component

K. Periasamy; W. S. Watson; A. Mohammed; H. Murray; B. Walker; S. Patil; R.M.D. Meek

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation. Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry. We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion.


Journal of Bone and Joint Surgery-british Volume | 2017

A comparison study of stem taper material loss at similar and mixed metal head-neck taper junctions

Dj Langton; R. P. Sidaginamale; T. J. Joyce; R.M.D. Meek; J. G. Bowsher; David J. Deehan; A. V. F. Nargol; James P. Holland

Aims We sought to determine whether cobalt‐chromium alloy (CoCr) femoral stem tapers (trunnions) wear more than titanium (Ti) alloy stem tapers (trunnions) when used in a large diameter (LD) metal‐on‐metal (MoM) hip arthroplasty system. Patients and Methods We performed explant analysis using validated methodology to determine the volumetric material loss at the taper surfaces of explanted LD CoCr MoM hip arthroplasties used with either a Ti alloy (n = 28) or CoCr femoral stem (n = 21). Only 12/14 taper constructs with a rough male taper surface and a nominal included angle close to 5.666° were included. Multiple regression modelling was undertaken using taper angle, taper roughness, bearing diameter (horizontal lever arm) as independent variables. Material loss was mapped using a coordinate measuring machine, profilometry and scanning electron microscopy. Results After adjustment for other factors, CoCr stem tapers were found to have significantly greater volumetric material loss than the equivalent Ti stem tapers. Conclusion When taper junction damage is identified during revision of a LD MoM hip, it should be suspected that a male taper composed of a standard CoCr alloy has sustained significant changes to the taper cone geometry which are likely to be more extensive than those affecting a Ti alloy stem.


Annals of medicine and surgery | 2014

Intraoperative cell salvage in revision hip surgery.

J.M. Herd; J.J. Joseph; M. McGarvey; Penelope M. Tsimbouri; A. Bennett; R.M.D. Meek; A. Morrison

Allogenic blood is a finite resource, with associated risks. Previous studies show intraoperative cell salvage (ICS) can reduce allogenic transfusion rates in orthopaedic surgery. However, there are concerns regarding efficacy and cost-effectiveness of ICS. This study was carried out to review ICS use in revision hip arthroplasty. All patients who underwent ICS and re-infusion between 2008 and 2010 in the Southern General Hospital (SGH) were audited. The fall in haemoglobin (Hb), volume of blood re-infused and postoperative allogenic transfusion rates were recorded. This group was compared to a similar SGH cohort who underwent surgery by the same surgeons between 2006 and 2008, and a pre-2005 control group where no ICS was used. The proportion of patients receiving a postoperative allogenic transfusion fell by 55% in the 2008–2010 ICS cohort compared with the control, and by 40% compared with the previous ICS group. In both instances, there was a statistically significant (p < 0.001) reduction in mean units transfused per patient; in the 2008–2010 ICS cohort, a mean of 0.8 units was used per patient, while 1.4 were used in the 2006–2008 cohort. 3.5 units were used in the control group. There was no statistically significant difference in age or preoperative Hb between the groups, or in length of hospital stay. In this study, ICS has been shown to be effective in reducing rates and volume of postoperative allogenic transfusion in patients undergoing revision hip surgery at the SGH. However, further work is needed to establish the effect of changing anaesthetic technique on postoperative allogenic transfusion rates.

Collaboration


Dive into the R.M.D. Meek's collaboration.

Top Co-Authors

Avatar

M.H. Grant

University of Strathclyde

View shared research outputs
Top Co-Authors

Avatar

H.M. Murray

Southern General Hospital

View shared research outputs
Top Co-Authors

Avatar

Sanjeev Patil

Southern General Hospital

View shared research outputs
Top Co-Authors

Avatar

J.G. Anderson

University of Strathclyde

View shared research outputs
Top Co-Authors

Avatar

Jon Clarke

Golden Jubilee National Hospital

View shared research outputs
Top Co-Authors

Avatar

M. R. Reed

Northumbria Healthcare NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S.J. MacGregor

University of Strathclyde

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge