Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ralph Blumhardt is active.

Publication


Featured researches published by Ralph Blumhardt.


Circulation | 1985

Comparative effects of volume loading, dobutamine, and nitroprusside in patients with predominant right ventricular infarction.

Louis J. Dell'Italia; Mark R. Starling; Ralph Blumhardt; John C. Lasher; Robert A. O'Rourke

To assess the value of volume loading and to determine the relative efficacy of dobutamine compared with nitroprusside therapy in acute right ventricular infarction (RVMI), 13 patients with clinical, hemodynamic, and radionuclide angiographic evidence of RVMI were evaluated. In 10 patients who had an initial pulmonary arterial wedge pressure less than 18 mm Hg, volume loading did not improve cardiac index (1.9 +/- 0.5 [SD] to 2.1 +/- 0.4 liters/min/m2), despite significant increases in mean right atrial pressure (11 +/- 2 to 15 +/- 2 mm Hg, p less than .001) and pulmonary arterial wedge pressure (10 +/- 4 to 15 +/- 2 mm Hg, p less than .001). Nine patients received dobutamine or nitroprusside in random order, while hemodynamic measurements and radionuclide angiograms were obtained simultaneously. Compared with nitroprusside, dobutamine produced a statistically significant increase in cardiac index (2.0 +/- 0.4 to 2.7 +/- 0.5 vs 2.1 +/- 0.4 to 2.3 +/- 0.5 liters/min/m2, p less than .001), stroke volume index (29 +/- 6 to 36 +/- 8 vs 29 +/- 6 to 30 +/- 6 ml/m2, p = .02), and right ventricular ejection fraction (30 +/- 8% to 42 +/- 7% vs 34 +/- 8% to 37 +/- 4%, p less than .01) by two-way analysis of variance. We conclude that volume loading does not improve cardiac index in patients with acute RVMI despite a rise in cardiac filling pressures and that infusion of dobutamine, after appropriate volume loading, produces a significant improvement in cardiac index and right ventricular ejection fraction over those after infusion of nitroprusside.


International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology | 1992

A simple method for producing a technetium-99m-labeled liposome which is stable In Vivo

William T. Phillips; Alan S. Rudolph; Beth Goins; James H. Timmons; Robert Klipper; Ralph Blumhardt

A new method for labelling preformed liposomes with technetium-99m (99mTc) has been developed which is simple to perform and stable in vivo. Previous 99mTc-liposome labels have had variable labeling efficiencies and stability. This method consistently achieves high labeling efficiencies (greater than 90%) with excellent stability. A commercially available radiopharmaceutical kit--hexamethylpropyleneamine oxime (HM-PAO)--is reconstituted with 99mTcO4- and then incubated with preformed liposomes that encapsulate glutathione. The incubation takes only 30 min at room temperature. Liposomes that co-encapsulate other proteins such as hemoglobin or albumin, in addition to glutathione, also label with high efficiency. Both in vitro and in vivo studies indicate good stability of this label. Rabbit images show significant spleen and liver uptake at 2 and 20 h after liposome infusion without visualization of thyroid, stomach or bladder activity. This labeling method can be used to study the biodistribution of a wide variety of liposome preparations that are being tested as novel drug delivery systems. This method of labeling liposomes with 99mTc may also have applications in diagnostic imaging.


Circulation | 1987

Hemodynamically important right ventricular infarction: follow-up evaluation of right ventricular systolic function at rest and during exercise with radionuclide ventriculography and respiratory gas exchange.

Louis J. Dell'Italia; N J Lembo; Mark R. Starling; Michael H. Crawford; R. S. Simmons; John C. Lasher; Ralph Blumhardt; J. Lancaster; Robert A. O'Rourke

The prognosis and recovery of right ventricular systolic function in patients with hemodynamically documented right ventricular myocardial infarction (RVMI) is unclear. Therefore 27 patients who met hemodynamic criteria for RVMI were followed for at least 1 year. Four patients died within 1 year and 23 survived. Postmortem examination performed in three of the four patients showed extensive infarction of the right and left ventricles. Survivors underwent early and late follow-up resting radionuclide ventriculograms and late exercise studies. During long-term follow-up (1 to 4 years) resting radionuclide ventriculography demonstrated a significant improvement in right ventricular ejection fraction (30 +/- 7% to 43 +/- 8%; p less than .001) and right ventricular wall motion index (2.2 +/- 0.4 to 1.5 +/- 0.5; p less than .001) in 18 patients who survived longer than 1 year. Fourteen of these patients underwent upright bicycle exercise while off beta-blocking drugs and peak radionuclide ejection fraction was acquired after anaerobic threshold was achieved. Right ventricular ejection fraction increased significantly from 41 +/- 10% to 47 +/- 12% (p less than .001), as did the left ventricular ejection fraction (55 +/- 15% to 60 +/- 12%; p less than .05). The direction and magnitude of change of the right ventricular ejection fraction correlated significantly with the left ventricular ejection fraction (r = .82, p less than .02). Deviations from this correlation occurred in patients who had a decreased forced expiratory volume in 1 sec and an abnormal ventilatory reserve during exercise.(ABSTRACT TRUNCATED AT 250 WORDS)


Circulation | 1985

Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography.

L J Dell'Italia; Mark R. Starling; Richard A. Walsh; F R Badke; John C. Lasher; Ralph Blumhardt

To determine the accuracy of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volumes, we initially studied 14 postmortem human right ventricular casts by water displacement and biplane cineventriculography. Biplane cineventriculographic right ventricular cast volumes, calculated by a modification of Simpsons rule algorithm, correlated well with right ventricular cast volumes measured by water displacement (r = .97, y = 8 + 0.88x, SEE = 6 ml). Moreover, the mean volumes obtained by both methods were no different (73 +/- 28 vs 73 +/- 25 ml). Subsequently, we studied 16 patients by both biplane cineventriculography and equilibrium radionuclide angiography. The uncorrected radionuclide right ventricular volumes were calculated by normalizing background corrected end-diastolic and end-systolic counts from hand-drawn regions of interest obtained by phase analysis for cardiac cycles processed, frame rate, and blood sample counts. Attenuation correction was performed by a simple geometric method. The attenuation-corrected radionuclide right ventricular end-diastolic volumes correlated with the cineventriculographic end-diastolic volumes (r = .91, y = 3 + 0.92x, SEE = 27 ml). Similarly, the attenuation-corrected radionuclide right ventricular end-systolic volumes correlated with the cineventriculographic end-systolic volumes (r = .93, y = - 1 + 0.91x, SEE = 16 ml). Also, the mean attenuation-corrected radionuclide end-diastolic and end-systolic volumes were no different than the average cineventriculographic end-diastolic and end-systolic volumes (160 +/- 61 and 83 +/- 44 vs 170 +/- 61 and 86 +/- 43 ml, respectively). Comparison of the uncorrected and attenuation-corrected radionuclide right ventricular volumes demonstrated narrower 95% confidence intervals for the attentuation-corrected right ventricular volume determinations over a wide range of cineventriculographic volumes. Thus we conclude that: (1) attenuation-corrected radionuclide right ventricular end-diastolic and end-systolic volumes compare closely with those obtained by a cast-validated biplane cineventriculographic method and (2) attenuation-corrected radionuclide right ventricular volumes correspond more closely to determinations of biplane cineventriculographic right ventricular volumes and are thus likely to be more accurate than uncorrected radionuclide right ventricular volumes.


Nuclear Medicine and Biology | 2001

Evaluation of [99mTc] liposomes as lymphoscintigraphic agents: comparison with [99mTc] sulfur colloid and [99mTc] human serum albumin

William T. Phillips; Trevor Andrews; Ho Ling Liu; Robert Klipper; Alfred J. Landry; Ralph Blumhardt; Beth Goins

Abstract This study investigates the use of [ 99m Tc] liposomes for the detection of sentinel lymph nodes. A variety of [ 99m Tc] liposome formulations were compared with common lymphoscintigraphic agents including [ 99m Tc] regular-sulfur colloid (SC), [ 99m Tc] 0.22 μ-filtered-SC, [ 99m Tc] reduced heating time 0.22 μ-filtered-SC, and [ 99m Tc] human serum albumin (HSA) in rabbits. Images were acquired for the first 60 minutes and at 24 hours, followed by tissue biodistribution study. All agents except [ 99m Tc] regular SC demonstrated good migration from the injection site. Agents were retained in the popliteal node at 24 hours to varying degrees as follows: both [ 99m Tc] filtered SC preparations > [ 99m Tc] regular SC > [ 99m Tc] liposomes > [ 99m Tc] HSA. [ 99m Tc] liposome imaging can be used to develop novel liposome compositions with improved lymph node diagnostic and drug delivery characteristics.


Investigative Radiology | 1984

Enhanced drug retention in VX2 tumors by use of degradable starch microspheres.

Lars E. Lorelius; Anthony R. Benedetto; Ralph Blumhardt; Harold V. Gaskill; Jack L. Lancaster; H. Stridbeck

Twenty-nine rabbits with 12- to 14-day-old VX2 tumors in the hind leg were injected intraarterially with technetium-99m (99mTc) DTPA and various combinations of biodegradable starch microspheres, Spherex (Pharmacia, Sweden), to evaluate the efficacy of the microspheres in enhancing tumor retention of 99mTc DTPA. A gamma camera and nuclear medicine computer were used to generate time activity curves of 99mTc DTPA concentration in the tumors. Blood flow to the tumor and various muscles was also measured at intervals by left ventricular injection of 15 micron radiolabeled plastic microspheres. Ninety minutes following the administration of 99mTc DTPA, specimens from the tumor, plasma and different muscles were counted in a NaI well counter connected to a multichannel analyzer. When biodegradable microspheres mixed with 99mTc DTPA were injected and followed by a slow infusion of plain starch microspheres, the 99mTc DTPA was retained in the tumor at concentrations up to 11 times that seen when 99mTc DTPA alone was injected; the corresponding biological half-time was 13 times longer than control values. Additionally, the degree of drug retention was inversely related to blood flow, with retention increasing as blood flow decreased. The results have possible applications to the use of biodegradable microspheres in the intraarterial delivery of chemotherapeutic agents to solid tumors.


Endocrine-related Cancer | 2014

Current controversies in the initial post-surgical radioactive iodine therapy for thyroid cancer: a narrative review

Ralph Blumhardt; Ely A Wolin; William T. Phillips; Umber A. Salman; Ronald C. Walker; Brendan C. Stack; Darlene Metter

Differentiated thyroid cancer (DTC) is the most common endocrine malignancy and the fifth most common cancer in women. DTC therapy requires a multimodal approach, including surgery, which is beyond the scope of this paper. However, for over 50 years, the post-operative management of the DTC post-thyroidectomy patient has included radioactive iodine (RAI) ablation and/or therapy. Before 2000, a typical RAI post-operative dose recommendation was 100 mCi for remnant ablation, 150 mCi for locoregional nodal disease, and 175-200 mCi for distant metastases. Recent recommendations have been made to decrease the dose in order to limit the perceived adverse effects of RAI including salivary gland dysfunction and inducing secondary primary malignancies. A significant controversy has thus arisen regarding the use of RAI, particularly in the management of the low-risk DTC patient. This debate includes the definition of the low-risk patient, RAI dose selection, and whether or not RAI is needed in all patients. To allow the reader to form an opinion regarding post-operative RAI therapy in DTC, a literature review of the risks and benefits is presented.


Medical Physics | 1997

Rapid objective measurement of gamma camera resolution using statistical moments

Trish A. Hander; Jack L. Lancaster; David T. Kopp; John C. Lasher; Ralph Blumhardt; Peter T. Fox

An easy and rapid method for the measurement of the intrinsic spatial resolution of a gamma camera was developed. The measurement is based on the first and second statistical moments of regions of interest (ROIs) applied to bar phantom images. This leads to an estimate of the modulation transfer function (MTF) and the full-width-at-half-maximum (FWHM) of a line spread function (LSF). Bar phantom images were acquired using four large field-of-view (LFOV) gamma cameras (Scintronix, Picker, Searle, Siemens). The following factors important for routine measurements of gamma camera resolution with this method were tested: ROI placement and shape, phantom orientation, spatial sampling, and procedural consistency. A 0.2% coefficient of variation (CV) between repeat measurements of MTF was observed for a circular ROI. The CVs of less than 2% were observed for measured MTF values for bar orientations ranging from -10 degrees to +10 degrees with respect to the x and y axes of the camera acquisition matrix. A 256 x 256 matrix (1.6 mm pixel spacing) was judged sufficient for routine measurements, giving an estimate of the FWHM to within 0.1 mm of manufacturer-specified values (3% difference). Under simulated clinical conditions, the variation in measurements attributable to procedural effects yielded a CV of less than 2% in newer generation cameras. The moments method for determining MTF correlated well with a peak-valley method, with an average difference of 0.03 across the range of spatial frequencies tested (0.11-0.17 line pairs/mm, corresponding to 4.5-3.0 mm bars). When compared with the NEMA method for measuring intrinsic spatial resolution, the moments method was found to be within 4% of the expected FWHM.


Clinical Nuclear Medicine | 1987

Value of tomographic thallium-201 imaging in patients with chest pain following coronary artery bypass grafting

Mark R. Starling; Richard A. Walsh; Gregory J. Dehmer; John C. Lasher; Ralph Blumhardt

To determine whether thallium-201 washout profile analysis can detect regional myocardial ischemia caused by coronary artery bypass graft occlusion or progression of disease in nonbypassed coronary arteries, 19 consecutive patients with chest pain following bypass grafting were evaluated with coronary arteriography and thallium-201 scintigraphy. Twenty of the 55 coronary artery regions were perfused by an occluded bypass graft or a significantly stenosed (≥70% diameter narrowing) nonbypassed coronary artery, while 35 coronary regions were perfused by patent bypass grafts or insignificantly diseased coronary arteries. The tomographic thallium-201 washout profile results correlated with the bypass graft and coronary arteriographic findings (k = 0.67, P < 0.001). The sensitivity of tomographic thallium-201 washout profile abnormalities for arteriographic abnormalities was 75%, while the specificity was 86%. The authors conclude that tomographic thallium-201 washout profile analysis may be very useful in the evaluation of patients with chest pain following coronary artery bypass grafting by detecting regional myocardial ischemia caused by occlusion of specific bypass grafts or progression of disease in nonbypassed coronary arteries.


Abdominal Imaging | 1984

Patterns of intestinal activity with Meckel's scintigraphy

Ralph Blumhardt; Gerald W. Growcock; Michael F. Hartshorne; John C. Lasher; Anthony R. Benedetto; Steven R. Bunker

Three patterns of intestinal activity were noted in a review of 64 patients studied with Tc-99m sodium pertechnetate for suspected Meckels diverticulum: no bowel activity seen (37.5%), bowel activity visualized after stomach activity (39.1%), and diffuse bowel activity seen simultaneously with stomach activity (23.4%). The latter pattern, which is relatively common, could mask a true Meckels diverticulum and lead to either a false-negative or indeterminate diagnosis. A series of 10 dogs was also studied to evaluate the effects of fasting and feeding on the intestinal pattern. No definite relationship was observed.

Collaboration


Dive into the Ralph Blumhardt's collaboration.

Top Co-Authors

Avatar

William T. Phillips

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

John C. Lasher

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

Jack L. Lancaster

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert Klipper

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

Beth Goins

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

Richard A. Walsh

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Alan S. Rudolph

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Michael F. Hartshorne

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

Darlene Metter

University of Texas Health Science Center at San Antonio

View shared research outputs
Researchain Logo
Decentralizing Knowledge