Richard A. Schatz
Scripps Health
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Richard A. Schatz.
The New England Journal of Medicine | 1994
David L. Fischman; Martin B. Leon; Donald S. Baim; Richard A. Schatz; M. Savage; Ian M. Penn; Katherine M. Detre; Lisa Veltri; Donald R. Ricci; Masakiyo Nobuyoshi; Michael W. Cleman; Richard R. Heuser; David Almond; Paul S. Teirstein; R. David Fish; Antonio Colombo; Jeffrey A. Brinker; Jeffrey W. Moses; Alex Shaknovich; John W. Hirshfeld; Stephen Bailey; Stephen G. Ellis; Randal Rake; Sheldon Goldberg
BACKGROUND Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. METHODS We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. RESULTS The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P < 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P < 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). CONCLUSIONS In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
The New England Journal of Medicine | 1997
Paul S. Teirstein; Vincent Massullo; Shirish Jani; Jeffrey J. Popma; Gary S. Mintz; Robert J. Russo; Richard A. Schatz; Erminia M. Guarneri; Stephen Steuterman; Nancy B. Morris; Martin B. Leon; Prabhakar Tripuraneni
BACKGROUND In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis. METHODS Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months. RESULTS Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P= 0.01). There were no apparent complications of the treatment. CONCLUSIONS In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis.
European Heart Journal | 2008
Matthew J. Price; Sarah Endemann; Raghava R. Gollapudi; Rafael Valencia; Curtiss T. Stinis; Justin P. Levisay; Alissa Ernst; Neil Sawhney; Richard A. Schatz; Paul S. Teirstein
AIMS The aim of this study was to determine whether platelet reactivity on clopidogrel therapy, as measured by a point-of-care platelet function assay, is associated with thrombotic events after percutaneous coronary intervention (PCI) with drug-eluting stents (DESs). METHODS AND RESULTS Platelet reactivity on clopidogrel (post-treatment reactivity) was measured with the VerifyNow P2Y12 assay (Accumetrics Inc., San Diego, CA, USA) in 380 patients undergoing PCI with sirolimus-eluting stents. Receiver-operating characteristic curve analysis was used to derive the optimal cut-off value for post-treatment reactivity in predicting 6 month out-of-hospital cardiovascular (CV) death, non-fatal MI, or stent thrombosis. The mean post-treatment reactivity was 184 +/- 85 PRU (P2Y12 reaction units). The optimal cut-off for the combined endpoint was a post-treatment reactivity > or =235 PRU [area under the curve 0.711 (95% confidence interval 0.529-0.893), P = 0.03], which was similar to the threshold of the upper tertile (231 PRU). Patients with post-treatment reactivity greater than the cut-off value had significantly higher rates of CV death (2.8 vs. 0%, P = 0.04), stent thrombosis (4.6 vs. 0%, P = 0.004), and the combined endpoint (6.5 vs. 1.0%, P = 0.008). CONCLUSION High post-treatment platelet reactivity measured with a point-of-care platelet function assay is associated with post-discharge events after PCI with DES, including stent thrombosis. Investigation of alternative clopidogrel dosing regimens to reduce ischaemic events in high-risk patients identified by this assay is warranted.
Circulation | 2007
Douglas W. Losordo; Richard A. Schatz; Christopher J. White; James E. Udelson; Vimal Veereshwarayya; Michelle Durgin; Kian Keong Poh; Robert Weinstein; Marianne Kearney; Muqtada Chaudhry; Aaron Burg; Liz Eaton; Lindsay Heyd; Tina Thorne; Leon Shturman; Peter Hoffmeister; Ken Story; Victor Zak; Douglas Dowling; Jay H. Traverse; Rachel E. Olson; Janice Flanagan; Donata Sodano; Toshinori Murayama; Atsuhiko Kawamoto; Kengo Kusano; Jill Wollins; Frederick G.P. Welt; Pinak B. Shah; Peter Soukas
Background— A growing population of patients with coronary artery disease experiences angina that is not amenable to revascularization and is refractory to medical therapy. Preclinical studies have indicated that human CD34+ stem cells induce neovascularization in ischemic myocardium, which enhances perfusion and function. Methods and Results— Twenty-four patients (19 men and 5 women aged 48 to 84 years) with Canadian Cardiovascular Society class 3 or 4 angina who were undergoing optimal medical treatment and who were not candidates for mechanical revascularization were enrolled in a double-blind, randomized (3:1), placebo-controlled dose-escalating study. Patients received granulocyte colony-stimulating factor 5 &mgr;g · kg−1 · d−1 for 5 days with leukapheresis on the fifth day. Selection of CD34+ cells was performed with a Food and Drug Administration–approved device. Electromechanical mapping was performed to identify ischemic but viable regions of myocardium for injection of cells (versus saline). The total dose of cells was distributed in 10 intramyocardial, transendocardial injections. Patients were required to have an implantable cardioverter-defibrillator or to temporarily wear a LifeVest wearable defibrillator. No incidence was observed of myocardial infarction induced by mobilization or intramyocardial injection. The intramyocardial injection of cells or saline did not result in cardiac enzyme elevation, perforation, or pericardial effusion. No incidence of ventricular tachycardia or ventricular fibrillation occurred during the administration of granulocyte colony-stimulating factor or intramyocardial injections. One patient with a history of sudden cardiac death/ventricular tachycardia/ventricular fibrillation had catheter-induced ventricular tachycardia during mapping that required cardioversion. Serious adverse events were evenly distributed. Efficacy parameters including angina frequency, nitroglycerine usage, exercise time, and Canadian Cardiovascular Society class showed trends that favored CD34+ cell–treated patients versus control subjects given placebo. Conclusions— A randomized trial of intramyocardial injection of autologous CD34+ cells in patients with intractable angina was completed that provides evidence for feasibility, safety, and bioactivity. A larger phase IIb study is currently under way to further evaluate this therapy.
Circulation | 2002
Douglas W. Losordo; Peter R. Vale; Robert C. Hendel; Charles E. Milliken; F. David Fortuin; Nancie Cummings; Richard A. Schatz; Takayuki Asahara; Jeffrey M. Isner; Richard E. Kuntz
Background—This phase 1/2 study investigated the safety of percutaneous catheter-based gene transfer of naked plasmid DNA encoding for vascular endothelial growth factor 2 (phVEGF2) to left ventricular (LV) myocardium in a prospective, randomized, double-blind, placebo-controlled, dose-escalating study of inoperable patients with class III or IV angina. Methods and Results—A steerable deflectable 8F catheter with a 27-gauge needle at its distal tip was advanced percutaneously to the endocardial surface of the LV in 19 patients (age, 61±2 years) with chronic myocardial ischemia who were not candidates for conventional revascularization. Patients were randomized in a double-blind fashion to receive 6 injections (total volume, 6.0 mL) of placebo or phVEGF2 in doses of 200 &mgr;g (n=9), 800 &mgr;g (n=9), or 2000 &mgr;g (n=1) guided by LV electromechanical (NOGA) mapping with a gene-to-placebo ratio of 2:1. A total of 114 LV injections were delivered and caused no hemodynamic alterations, sustained ventricular arrhythmias, ECG evidence of infarction, or ventricular perforation. End-point analysis at 12 weeks disclosed a statistically significant improvement in Canadian Cardiovascular Society (CCS) angina class in phVEGF2-treated versus placebo-treated patients (−1.3 versus −0.1, P =0.04). Remaining efficacy end points—including change in exercise duration (91.8 versus 3.9 seconds), functional improvement by ≥2 CCS classes (9 of 12 versus 1 of 6), and Seattle Angina Questionnaire data—all showed strong trends favoring efficacy of phVEGF2 versus placebo treatment. Conclusions—This phase 1/2, double-blind, randomized trial provides preliminary data that support safety of phVEGF2 catheter-mediated myocardial gene transfer. The statistically significant reduction in anginal class and strong positive trends for remaining end points suggest that a larger phase 2/3 trial is warranted.
Circulation Research | 2011
Douglas W. Losordo; Timothy D. Henry; Charles J. Davidson; Joon Sup Lee; Marco A. Costa; Theodore A. Bass; Farrell O. Mendelsohn; F. David Fortuin; Carl J. Pepine; Jay H. Traverse; David Amrani; Bruce M. Ewenstein; Norbert Riedel; Kenneth Story; Kerry Barker; Thomas J. Povsic; Robert A. Harrington; Richard A. Schatz
Rationale: A growing number of patients with coronary disease have refractory angina. Preclinical and early-phase clinical data suggest that intramyocardial injection of autologous CD34+ cells can improve myocardial perfusion and function. Objective: Evaluate the safety and bioactivity of intramyocardial injections of autologous CD34+ cells in patients with refractory angina who have exhausted all other treatment options. Methods and Results: In this prospective, double-blind, randomized, phase II study (ClinicalTrials.gov identifier: NCT00300053), 167 patients with refractory angina received 1 of 2 doses (1×105 or 5×105 cells/kg) of mobilized autologous CD34+ cells or an equal volume of diluent (placebo). Treatment was distributed into 10 sites of ischemic, viable myocardium with a NOGA mapping injection catheter. The primary outcome measure was weekly angina frequency 6 months after treatment. Weekly angina frequency was significantly lower in the low-dose group than in placebo-treated patients at both 6 months (6.8±1.1 versus 10.9±1.2, P=0.020) and 12 months (6.3±1.2 versus 11.0±1.2, P=0.035); measurements in the high-dose group were also lower, but not significantly. Similarly, improvement in exercise tolerance was significantly greater in low-dose patients than in placebo-treated patients (6 months: 139±151 versus 69±122 seconds, P=0.014; 12 months: 140±171 versus 58±146 seconds, P=0.017) and greater, but not significantly, in the high-dose group. During cell mobilization and collection, 4.6% of patients had cardiac enzyme elevations consistent with non-ST segment elevation myocardial infarction. Mortality at 12 months was 5.4% in the placebo-treatment group with no deaths among cell-treated patients. Conclusions: Patients with refractory angina who received intramyocardial injections of autologous CD34+ cells (105 cells/kg) experienced significant improvements in angina frequency and exercise tolerance. The cell-mobilization and -collection procedures were associated with cardiac enzyme elevations, which will be addressed in future studies.
Circulation | 2000
Paul S. Teirstein; Vincent Massullo; Shirish Jani; Jeffrey J. Popma; Robert J. Russo; Richard A. Schatz; Erminia M. Guarneri; Stephen Steuterman; Kathleen Sirkin; David Cloutier; Martin B. Leon; Prabhakar Tripuraneni
BACKGROUND Although several early trials indicate treatment of restenosis with radiation therapy is safe and effective, the long-term impact of this new technology has been questioned. The objective of this report is to document angiographic and clinical outcome 3 years after treatment of restenotic stented coronary arteries with catheter-based (192)Ir. METHODS AND RESULTS A double-blind, randomized trial compared (192)Ir with placebo sources in patients with previous restenosis after coronary angioplasty. Over a 9-month period, 55 patients were enrolled; 26 were randomized to (192)Ir and 29 to placebo. At 3-year follow-up, target-lesion revascularization was significantly lower in the (192)Ir group (15. 4% versus 48.3%; P<0.01). The dichotomous restenosis rate at 3-year follow-up was also significantly lower in (192)Ir patients (33% versus 64%; P<0.05). In a subgroup of patients with 3-year angiographic follow-up not subjected to target-lesion revascularization by the 6-month angiogram, the mean minimal luminal diameter between 6 months and 3 years decreased from 2.49+/-0.81 to 2.12+/-0.73 mm in (192)Ir patients but was unchanged in placebo patients. CONCLUSIONS The early clinical benefits observed after treatment of coronary restenosis with (192)Ir appear durable at late follow-up. Angiographic restenosis continues to be significantly reduced in (192)Ir-treated patients, but a small amount of late loss was observed between the 6-month and 3-year follow-up time points. No events occurred in the (192)Ir group to suggest major untoward effects of vascular radiotherapy. At 3-year follow-up, vascular radiotherapy continues to be a promising new treatment for restenosis.
Journal of the American College of Cardiology | 1994
Michael P. Savage; David L. Fischman; Richard A. Schatz; Paul S. Teirstein; Martin B. Leon; Donald S. Baim; Stephen G. Ellis; Eric J. Topol; John W. Hirshfeld; Michael W. Cleman; Maurice Buchbinder; Steven R. Bailey; Richard R. Heuser; Craig M. Walker; R. Charles Curry; Sharon Gebhardt; Randal Rake; Sheldon Goldberg
Objectives. The purpose of this study was to examine the long-term clinical and angiographic outcome after coronary implantation. Background. Previous reports haw shown a discordance between the excellent initial angiographic results and subsequent adverse clinical events after coronary artery stenting. Methods. Single Palmaz-Schatz stents were electively implanted in the native coronary arteries of 300 consecutive patients. Angiograms were obtained at baseline, after balloon angioplasty, after stent implantation and at 6 months after implantation. Films were analyzed by a panel of engiographers utilizing en automated edge detection program, Clinical events, including death, myocardial infarction, coronary bypass surgery and repeat angioplasty, were recorded for 1 year. Results. Although there were no acute in-laboratory vessel closures, stent thrombosis occurred in 14 patients (4.7%) at a mean ±SD of 5 ± 3 days after implantation. Two hundred fifty-eight (90%) of 286 eligible patients had follow-up angiography at 6.1 ± 2.2 months after stent implantation. Minimal lumen diameter increased from 0.80 ± 039 mm at baseline to 1.65 +- 0.51 mm after angioplasty and further increased to 2.55 ± 0.49 mm after stent placement (p = 0.0001). At follow-up there was a 0.85-mm late loss in lumen diameter, with a final minimal lumen diameter at 6 months of 1.70 ± 0.71 mm. Restenosis, defined as ≥ 50% diameter stenosis at follow-up, occurred in 14% of patients with previously untreated lesions and in 39% of patients with previous angioplasty (p < 0.001). Clinical events after 1 year for the entire group of 300 patients included death in 0.7%, myocardial infarction in 3.7%, bypass grafting in 8% and repeat angioplasty in 13%. Freedom from any adverse clinical event was 80% for all treated patients and 87% for those with previously untreated lesions. Conclusions. Elective use of this balloon-expandable stent in the native coronary circulation is associated with a low restenosis rate by quantitative angiography in previously untreated lesions and a favorable clinical outcome with an excellent event-free survival rate at 1 year.
American Journal of Cardiology | 1993
Donald S. Baim; Marc J. Levine; Martin Leon; Sally Levine; Steven G. Ellis; Richard A. Schatz
Abstract Coronary stenting was introduced in the hope of improving both the short- and long-term results of conventional balloon angioplasty. 1 Nearly 2,000 patients have been treated with the balloon expandable Palmaz-Schatz stent in the United States since 1988, with a 98% acute placement success and minimal residual stenosis. 2 Acute closure of the stent has been rare, but subacute thrombotic occlusion has been reported within the first several weeks after stent placement in almost 3% of patients, despite an anticoagulant program including aspirin, dipyridamole and Coumadin ™ . The incidence of subsequent restenosis varies with the size, location and number of stents placed, but ≥20% of successfully stented patients show angiographic evidence of restenosis 6 months after stent placement. 3,4 Despite the well-recognized incidence of in-stent restenosis, however, there have been no formal reports outlining how this type of lesion responds to various management alternatives — in particular to repeat dilatation.
Journal of the American College of Cardiology | 1995
S. Chiu Wong; Donald S. Baim; Richard A. Schatz; Paul S. Teirstein; Spencer B. King; R.Charles Curry; Richard R. Heuser; Stephen G. Ellis; Michael W. Cleman; Paul Overlie; John W. Hirshfeld; Craig M. Walker; Frank Litvack; Jeffrey A. Brinker; Maurice Buchbinder; Sheldon Goldberg; Ya Chien Chuang; Martin B. Leon
OBJECTIVES This study reports the multicenter registry experience evaluating the safety and efficacy of the Palmaz-Schatz stent in the treatment of saphenous vein graft disease. BACKGROUND Saphenous vein graft angioplasty is associated with frequent periprocedural complications and a high frequency of restenosis. Stent implantation has been shown to reduce restenosis, with improved long-term outcomes in the treatment of native coronary artery disease. Preliminary experience with stent placement in the treatment of saphenous vein graft lesions has been favorable. METHODS Twenty U.S. investigator sites enrolled a total of 589 symptomatic patients (624 lesions) for treatment of focal vein graft stenoses between January 1990 and April 1992. Follow-up angiography was performed at 6 months, and the clinical course of all study patients was prospectively collected at regular intervals for up to 12 months. RESULTS Stent delivery was successful in 98.8% of cases, and the procedural success rate was 97.1%. The lesion diameter stenosis decreased from 82 +/- 12% (mean +/- SD) before to 6.6 +/- 10.2% after treatment. Major in-hospital complications occurred in 17 patients (2.9%); stent thrombosis was found in 8 (1.4%); and major vascular or bleeding complications were noted in 83 (14.3%). Six-month angiographic follow-up revealed an overall restenosis rate (> or = 50% diameter stenosis) of 29.7%. Multivariate logistic regression analysis indicated that 1) restenotic lesions, 2) smaller reference vessel size, 3) history of diabetes mellitus, and 4) higher percent poststent diameter stenosis were independent predictors of restenosis. The 12-month actuarial event-free survival was 76.3%. CONCLUSIONS Stent implantation in patients with focal saphenous vein graft lesions can be achieved with a high rate of procedural success, acceptable major complications, reduced angiographic restenosis and favorable late clinical outcome compared with historical balloon angioplasty control series. The rigorous anticoagulation regimen after stent placement results in more frequent vascular and other bleeding complications. Future randomized studies comparing standard balloon angioplasty with stent implantation are warranted to properly assess the full impact of stent placement in the treatment of saphenous vein graft lesions.