Paul S. Teirstein
Scripps Health
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Paul S. Teirstein.
The New England Journal of Medicine | 1994
David L. Fischman; Martin B. Leon; Donald S. Baim; Richard A. Schatz; M. Savage; Ian M. Penn; Katherine M. Detre; Lisa Veltri; Donald R. Ricci; Masakiyo Nobuyoshi; Michael W. Cleman; Richard R. Heuser; David Almond; Paul S. Teirstein; R. David Fish; Antonio Colombo; Jeffrey A. Brinker; Jeffrey W. Moses; Alex Shaknovich; John W. Hirshfeld; Stephen Bailey; Stephen G. Ellis; Randal Rake; Sheldon Goldberg
BACKGROUND Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. METHODS We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. RESULTS The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P < 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P < 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). CONCLUSIONS In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
The New England Journal of Medicine | 2012
Susheel Kodali; Mathew R. Williams; Craig R. Smith; Lars G. Svensson; John G. Webb; Raj Makkar; Gregory P. Fontana; Todd M. Dewey; Vinod H. Thourani; Augusto D. Pichard; Michael P. Fischbein; Wilson Y. Szeto; Scott Lim; Kevin L. Greason; Paul S. Teirstein; S. Chris Malaisrie; Pamela S. Douglas; Rebecca T. Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J. Akin; William N. Anderson; Martin B. Leon; Trial Investigators
BACKGROUND The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).
JAMA | 2011
Matthew J. Price; Peter B. Berger; Paul S. Teirstein; Jean-François Tanguay; Dominick J. Angiolillo; Douglas Spriggs; Sanjeev Puri; Mark Robbins; Kirk N. Garratt; Olivier F. Bertrand; Michael E. Stillabower; Joseph Aragon; David E. Kandzari; Curtiss T. Stinis; Michael S. Lee; Steven V. Manoukian; Christopher P. Cannon; Nicholas J. Schork; Eric J. Topol
CONTEXT High platelet reactivity while receiving clopidogrel has been linked to cardiovascular events after percutaneous coronary intervention (PCI), but a treatment strategy for this issue is not well defined. OBJECTIVE To evaluate the effect of high-dose compared with standard-dose clopidogrel in patients with high on-treatment platelet reactivity after PCI. DESIGN, SETTING, AND PATIENTS Randomized, double-blind, active-control trial (Gauging Responsiveness with A VerifyNow assay-Impact on Thrombosis And Safety [GRAVITAS]) of 2214 patients with high on-treatment reactivity 12 to 24 hours after PCI with drug-eluting stents at 83 centers in North America between July 2008 and April 2010. INTERVENTIONS High-dose clopidogrel (600-mg initial dose, 150 mg daily thereafter) or standard-dose clopidogrel (no additional loading dose, 75 mg daily) for 6 months. MAIN OUTCOME MEASURES The primary end point was the 6-month incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. The key safety end point was severe or moderate bleeding according to the Global Utilization of Streptokinase and t-PA for Occluded Coronary Arteries (GUSTO) definition. A key pharmacodynamic end point was the rate of persistently high on-treatment reactivity at 30 days. RESULTS At 6 months, the primary end point had occurred in 25 of 1109 patients (2.3%) receiving high-dose clopidogrel compared with 25 of 1105 patients (2.3%) receiving standard-dose clopidogrel (hazard ratio [HR], 1.01; 95% confidence interval [CI], 0.58-1.76; P = .97). Severe or moderate bleeding was not increased with the high-dose regimen (15 [1.4%] vs 25 [2.3%], HR, 0.59; 95% CI, 0.31-1.11; P = .10). Compared with standard-dose clopidogrel, high-dose clopidogrel provided a 22% (95% CI, 18%-26%) absolute reduction in the rate of high on-treatment reactivity at 30 days (62%; 95% CI, 59%-65% vs 40%; 95% CI, 37%-43%; P < .001). CONCLUSIONS Among patients with high on-treatment reactivity after PCI with drug-eluting stents, the use of high-dose clopidogrel compared with standard-dose clopidogrel did not reduce the incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00645918.
The New England Journal of Medicine | 1997
Paul S. Teirstein; Vincent Massullo; Shirish Jani; Jeffrey J. Popma; Gary S. Mintz; Robert J. Russo; Richard A. Schatz; Erminia M. Guarneri; Stephen Steuterman; Nancy B. Morris; Martin B. Leon; Prabhakar Tripuraneni
BACKGROUND In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis. METHODS Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months. RESULTS Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P= 0.01). There were no apparent complications of the treatment. CONCLUSIONS In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis.
The New England Journal of Medicine | 2001
Martin B. Leon; Paul S. Teirstein; Jeffrey W. Moses; Prabhakar Tripuraneni; Alexandra J. Lansky; Shirish Jani; S. Chiu Wong; David J. Fish; Stephen G. Ellis; David R. Holmes; Dean Kerieakes; Richard E. Kuntz
BACKGROUND Although the frequency of restenosis after coronary angioplasty is reduced by stenting, when restenosis develops within a stent, the risk of subsequent restenosis is greater than 50 percent. We report on a multicenter, double-blind, randomized trial of intracoronary radiation therapy for the treatment of in-stent restenosis. METHODS Of 252 eligible patients in whom in-stent restenosis had developed, 131 were randomly assigned to receive an indwelling intracoronary ribbon containing a sealed source of iridium-192, and 121 were assigned to receive a similar-appearing nonradioactive ribbon (placebo). RESULTS The primary end point, a composite of death, myocardial infarction, and the need for repeated revascularization of the target lesion during nine months of follow-up, occurred in 53 patients assigned to placebo (43.8 percent) and 37 patients assigned to iridium-192 (28.2 percent, P=0.02). However, the reduction in the incidence of major adverse cardiac events was determined solely by a diminished need for revascularization of the target lesion, not by reductions in the incidence of death or myocardial infarction. Late thrombosis occurred in 5.3 percent of the iridium-192 group, as compared with 0.8 percent of the placebo group (P=0.07), resulting in more late myocardial infarctions in the iridium-192 group (9.9 percent vs. 4.1 percent, P=0.09). Late thrombosis occurred in irradiated patients only after the discontinuation of oral antiplatelet therapy (with ticlopidine or clopidogrel) and only in patients who had received new stents at the time of radiation treatment. CONCLUSIONS Intracoronary irradiation with iridium-192 resulted in lower rates of clinical and angiographic restenosis, although it was also associated with a higher rate of late thrombosis, resulting in an increased risk of myocardial infarction. If the problem of late thrombosis within the stent can be overcome, intracoronary irradiation with iridium-192 may become a useful approach to the treatment of in-stent restenosis.
European Heart Journal | 2008
Matthew J. Price; Sarah Endemann; Raghava R. Gollapudi; Rafael Valencia; Curtiss T. Stinis; Justin P. Levisay; Alissa Ernst; Neil Sawhney; Richard A. Schatz; Paul S. Teirstein
AIMS The aim of this study was to determine whether platelet reactivity on clopidogrel therapy, as measured by a point-of-care platelet function assay, is associated with thrombotic events after percutaneous coronary intervention (PCI) with drug-eluting stents (DESs). METHODS AND RESULTS Platelet reactivity on clopidogrel (post-treatment reactivity) was measured with the VerifyNow P2Y12 assay (Accumetrics Inc., San Diego, CA, USA) in 380 patients undergoing PCI with sirolimus-eluting stents. Receiver-operating characteristic curve analysis was used to derive the optimal cut-off value for post-treatment reactivity in predicting 6 month out-of-hospital cardiovascular (CV) death, non-fatal MI, or stent thrombosis. The mean post-treatment reactivity was 184 +/- 85 PRU (P2Y12 reaction units). The optimal cut-off for the combined endpoint was a post-treatment reactivity > or =235 PRU [area under the curve 0.711 (95% confidence interval 0.529-0.893), P = 0.03], which was similar to the threshold of the upper tertile (231 PRU). Patients with post-treatment reactivity greater than the cut-off value had significantly higher rates of CV death (2.8 vs. 0%, P = 0.04), stent thrombosis (4.6 vs. 0%, P = 0.004), and the combined endpoint (6.5 vs. 1.0%, P = 0.008). CONCLUSION High post-treatment platelet reactivity measured with a point-of-care platelet function assay is associated with post-discharge events after PCI with DES, including stent thrombosis. Investigation of alternative clopidogrel dosing regimens to reduce ischaemic events in high-risk patients identified by this assay is warranted.
Circulation | 2005
Gregg W. Stone; Nicolaus Reifart; Issam Moussa; Angela Hoye; David A. Cox; Antonio Colombo; Donald S. Baim; Paul S. Teirstein; Bradley H. Strauss; Matthew R. Selmon; Gary S. Mintz; Osamu Katoh; Kazuaki Mitsudo; Takahiko Suzuki; Hideo Tamai; Eberhard Grube; Louis Cannon; David E. Kandzari; Mark Reisman; Robert S. Schwartz; Steven R. Bailey; George Dangas; Roxana Mehran; Alexander Abizaid; Jeffrey W. Moses; Martin B. Leon; Patrick W. Serruys
In Part I of this article, the definitions, prevalence, and clinical presentation of chronic total occlusions (CTOs) were reviewed, the histopathology of CTOs was examined, efforts to replicate human CTOs with experimental models were appraised, and the clinical relevance and rationale for CTO revascularization were evaluated.1 In Part II, we summarize the technical approach to and outcomes after percutaneous coronary intervention (PCI) of occluded coronary arteries, describe the novel devices and drugs approved and undergoing investigation for CTO recanalization, and conclude with practical perspectives on managing the patient with 1 or more chronic coronary occlusions. ### Patient Selection and Revascularization Strategies PCI of CTOs constitutes as many as 20% of all angioplasty procedures at selected centers,2 although a rate of &10% is more typical,3–6 suggesting that CTO angioplasty is attempted in 50 000 to 100 000 patients per year in the United States. Many more CTOs are present for which PCI is never attempted, representing one of the most common causes for referral to bypass surgery rather than PCI.6–8 Furthermore, a large proportion of patients with CTOs are managed medically, the prognosis of whom may vary depending on the extent of viable myocardium and ischemia, concomitant atherosclerosis in other coronary and noncoronary vascular territories, and other comorbid conditions. The decision to attempt PCI of a CTO (versus continued medical therapy or surgical revascularization) requires an individualized risk/benefit analysis, encompassing clinical, angiographic, and technical considerations. Clinically, the patient’s age, symptom severity, associated comorbidities (eg, diabetes mellitus and chronic renal insufficiency), and overall functional status are major determinants of treatment strategy. Angiographically, the extent and complexity of coronary artery disease (eg, single-vessel versus multivessel disease, single versus multiple total occlusions, likelihood for complete revascularization), left ventricular function, and the presence and degree of valvular heart disease should be considered. The technical probability of achieving …
The New England Journal of Medicine | 2015
Stephen G. Ellis; D. Christopher Metzger; Ronald P. Caputo; David G. Rizik; Paul S. Teirstein; Marc R. Litt; Annapoorna Kini; Ameer Kabour; Steven O. Marx; Jeffrey J. Popma; Robert McGreevy; Zhen Zhang; Charles A. Simonton; Gregg W. Stone
BACKGROUND In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. METHODS In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. RESULTS Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). CONCLUSIONS In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).
Circulation | 2001
Steven R. Steinhubl; J. David Talley; Gregory A. Braden; James E. Tcheng; Peter J. Casterella; David J. Moliterno; Frank I. Navetta; Peter B. Berger; Jeffrey J. Popma; George Dangas; Richard L. Gallo; David C. Sane; J.F. Saucedo; Gang Jia; A. Michael Lincoff; Pierre Theroux; David R. Holmes; Paul S. Teirstein
Background—The optimal level of platelet inhibition with a glycoprotein (GP) IIb/IIIa antagonist necessary to minimize thrombotic complications in patients undergoing a percutaneous coronary intervention (PCI) is currently unknown. Methods and Results—Five hundred patients undergoing a PCI with the planned use of a GP IIb/IIIa inhibitor had platelet inhibition measured at 10 minutes, 1 hour, 8 hours, and 24 hours after the initiation of therapy with the Ultegra Rapid Platelet Function Assay (Accumetrics). Major adverse cardiac events (MACEs: composite of death, myocardial infarction, and urgent target vessel revascularization) were prospectively monitored, and the incidence correlated with the measured level of platelet function inhibition at all time points. One quarter of all patients did not achieve ≥95% inhibition 10 minutes after the bolus and experienced a significantly higher incidence of MACEs (14.4% versus 6.4%, P =0.006). Patients whose platelet function was <70% inhibited at 8 hours after the start of therapy had a MACE rate of 25% versus 8.1% for those ≥70% inhibited (P =0.009). By multivariate analysis, platelet function inhibition ≥95% at 10 minutes after the start of therapy was associated with a significant decrease in the incidence of a MACE (odds ratio 0.46, 95% CI 0.22 to 0.96, P =0.04). Conclusions—Substantial variability in the level of platelet function inhibition is achieved with GP IIb/IIIa antagonist therapy among patients undergoing PCI. The level of platelet function inhibition as measured by a point-of-care assay is an independent predictor for the risk of MACEs after PCI.
Circulation | 2000
Paul S. Teirstein; Vincent Massullo; Shirish Jani; Jeffrey J. Popma; Robert J. Russo; Richard A. Schatz; Erminia M. Guarneri; Stephen Steuterman; Kathleen Sirkin; David Cloutier; Martin B. Leon; Prabhakar Tripuraneni
BACKGROUND Although several early trials indicate treatment of restenosis with radiation therapy is safe and effective, the long-term impact of this new technology has been questioned. The objective of this report is to document angiographic and clinical outcome 3 years after treatment of restenotic stented coronary arteries with catheter-based (192)Ir. METHODS AND RESULTS A double-blind, randomized trial compared (192)Ir with placebo sources in patients with previous restenosis after coronary angioplasty. Over a 9-month period, 55 patients were enrolled; 26 were randomized to (192)Ir and 29 to placebo. At 3-year follow-up, target-lesion revascularization was significantly lower in the (192)Ir group (15. 4% versus 48.3%; P<0.01). The dichotomous restenosis rate at 3-year follow-up was also significantly lower in (192)Ir patients (33% versus 64%; P<0.05). In a subgroup of patients with 3-year angiographic follow-up not subjected to target-lesion revascularization by the 6-month angiogram, the mean minimal luminal diameter between 6 months and 3 years decreased from 2.49+/-0.81 to 2.12+/-0.73 mm in (192)Ir patients but was unchanged in placebo patients. CONCLUSIONS The early clinical benefits observed after treatment of coronary restenosis with (192)Ir appear durable at late follow-up. Angiographic restenosis continues to be significantly reduced in (192)Ir-treated patients, but a small amount of late loss was observed between the 6-month and 3-year follow-up time points. No events occurred in the (192)Ir group to suggest major untoward effects of vascular radiotherapy. At 3-year follow-up, vascular radiotherapy continues to be a promising new treatment for restenosis.
Collaboration
Dive into the Paul S. Teirstein's collaboration.
University of Texas Health Science Center at San Antonio
View shared research outputs