Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Richard Su is active.

Publication


Featured researches published by Richard Su.


Biomaterials | 2010

Photoacoustic imaging of living mouse brain vasculature using hollow gold nanospheres

Wei Lu; Qian Huang; Geng Ku; Xiaoxia Wen; Min Zhou; Dmitry V. Guzatov; Peter Brecht; Richard Su; Alexander A. Oraevsky; Lihong V. Wang; Chun Li

Photoacoustic tomography (PAT) also referred to as optoacoustic tomography (OAT) is a hybrid imaging modality that employs nonionizing optical radiation and ultrasonic detection. Here, we describe the application of a new class of optical contrast agents based on mesoscopic hollow gold nanospheres (HAuNS) to PAT. HAuNS are approximately 40 nm in diameter with a hollow interior and consist of a thin gold wall. They display strong resonance absorption tuned to the near-infrared (NIR) range, with an absorption peak at 800 nm, whose photoacoustic efficiency is significantly greater than that of blood. Following surface conjugation with thiolated poly(ethylene glycol), the pegylated HAuNS (PEG-HAuNS) had distribution and elimination half-lives of 1.38 +/- 0.38 and 71.82 +/- 30.46 h, respectively. Compared with PAT images based on the intrinsic optical contrast in nude mice, the PAT images acquired within 2 h after intravenous administration of PEG-HAuNS showed the brain vasculature with greater clarity and detail. The image depicted brain blood vessels as small as approximately 100 mum in diameter using PEG-HAuNS as contrast agents. Preliminary results showed no acute toxicity to the liver, spleen, or kidneys in mice following a single imaging dose of PEG-HAuNS. Our results indicate that PEG-HAuNS are promising contrast agents for PAT, with high spatial resolution and enhanced sensitivity.


Journal of Biomedical Optics | 2009

Whole-body three-dimensional optoacoustic tomography system for small animals

Hans-Peter Brecht; Richard Su; Matthew P. Fronheiser; Sergey A. Ermilov; André Conjusteau; Alexander A. Oraevsky

We develop a system for three-dimensional whole-body optoacoustic tomography of small animals for applications in preclinical research. The tomographic images are obtained while the objects of study (phantoms or mice) are rotated within a sphere outlined by a concave arc-shaped array of 64 piezocomposite transducers. Two pulsed lasers operating in the near-IR spectral range (755 and 1064 nm) with an average pulsed energy of about 100 mJ, a repetition rate of 10 Hz, and a pulse duration of 15 to 75 ns are used as optical illumination sources. During the scan, the mouse is illuminated orthogonally to the array with two wide beams of light from a bifurcated fiber bundle. The system is capable of generating images of individual organs and blood vessels through the entire body of a mouse with spatial resolution of approximately 0.5 mm.


IEEE Transactions on Medical Imaging | 2011

An Imaging Model Incorporating Ultrasonic Transducer Properties for Three-Dimensional Optoacoustic Tomography

Kun Wang; Sergey A. Ermilov; Richard Su; Hans-Peter Brecht; Alexander A. Oraevsky; Mark A. Anastasio

Optoacoustic tomography (OAT) is a hybrid imaging modality that combines the advantages of optical and ultrasound imaging. Most existing reconstruction algorithms for OAT assume that the ultrasound transducers employed to record the measurement data are point-like. When transducers with large detecting areas and/or compact measurement geometries are utilized, this assumption can result in conspicuous image blurring and distortions in the reconstructed images. In this work, a new OAT imaging model that incorporates the spatial and temporal responses of an ultrasound transducer is introduced. A discrete form of the imaging model is implemented and its numerical properties are investigated. We demonstrate that use of the imaging model in an iterative reconstruction method can improve the spatial resolution of the optoacoustic images as compared to those reconstructed assuming point-like ultrasound transducers.


Physics in Medicine and Biology | 2012

Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography

Kun Wang; Richard Su; Alexander A. Oraevsky; Mark A. Anastasio

Iterative image reconstruction algorithms for optoacoustic tomography (OAT), also known as photoacoustic tomography, have the ability to improve image quality over analytic algorithms due to their ability to incorporate accurate models of the imaging physics, instrument response and measurement noise. However, to date, there have been few reported attempts to employ advanced iterative image reconstruction algorithms for improving image quality in three-dimensional (3D) OAT. In this work, we implement and investigate two iterative image reconstruction methods for use with a 3D OAT small animal imager: namely a penalized least-squares (PLS) method employing a quadratic smoothness penalty and a PLS method employing a total variation norm penalty. The reconstruction algorithms employ accurate models of the ultrasonic transducer impulse responses. Experimental data sets are employed to compare the performances of the iterative reconstruction algorithms to that of a 3D filtered backprojection (FBP) algorithm. By the use of quantitative measures of image quality, we demonstrate that the iterative reconstruction algorithms can mitigate image artifacts and preserve spatial resolution more effectively than FBP algorithms. These features suggest that the use of advanced image reconstruction algorithms can improve the effectiveness of 3D OAT while reducing the amount of data required for biomedical applications.


Journal of Biomedical Optics | 2010

Real-time optoacoustic monitoring and three-dimensional mapping of a human arm vasculature

Matthew P. Fronheiser; Sergey A. Ermilov; Hans-Peter Brecht; André Conjusteau; Richard Su; Ketan Mehta; Alexander A. Oraevsky

We present our findings from a real-time laser optoacoustic imaging system (LOIS). The system utilizes a Q-switched Nd:YAG laser; a standard 128-channel ultrasonic linear array probe; custom electronics and custom software to collect, process, and display optoacoustic (OA) images at 10 Hz. We propose that this system be used during preoperative mapping of forearm vessels for hemodialysis treatment. To demonstrate the real-time imaging capabilities of the system, we show OA images of forearm vessels in a volunteer and compare our results to ultrasound images of the same region. Our OA images show blood vessels in high contrast. Manipulations with the probe enable us to locate and track arteries and veins of a forearm in real time. We also demonstrate the ability to combine a series of OA image slices into a volume for spatial representation of the vascular network. Finally, we use frame-by-frame analysis of the recorded OA video to measure dynamic changes of the crossection of the ulnar artery.


Photons Plus Ultrasound: Imaging and Sensing 2009 | 2009

Development of laser optoacoustic and ultrasonic imaging system for breast cancer utilizing handheld array probes

Sergey A. Ermilov; Matthew P. Fronheiser; Hans Peter Brecht; Richard Su; André Conjusteau; Ketan Mehta; Pamela M Otto; Alexander A. Oraevsky

We describe two laser optoacoustic imaging systems for breast cancer detection based on arrays of acoustic detectors operated manually in a way similar to standard ultrasonic breast imaging. The systems have the advantages of standard light illumination (regardless of the interrogated part of the breast), the ability to visualize any part of the breast, and convenience in operation. The first system could work in both ultrasonic and optoacoustic mode, and was developed based on a linear ultrasonic breast imaging probe with two parallel rectangular optical bundles. We used it in a pilot clinical study to provide for the first time demonstration that the boundaries of the tumors visualized on the optoacoustic and ultrasonic images matched. Such correlation of coregistered images proves that the objects on both images represented indeed the same tumor. In the optoacoustic mode we were also able to visualize blood vessels located in the neighborhood of the tumor. The second system was proposed as a circular array of acoustic transducers with an axisymmetric laser beam in the center. It was capable of 3D optoacoustic imaging with minimized optoacoustic artifacts caused by the distribution of the absorbed optical energy within the breast tissue. The distribution of optical energy absorbed in the bulk tissue of the breast was removed from the image by implementing the principal component analysis on the measured signals. The computer models for optoacoustic imaging using these two handheld probes were developed. The models included three steps: (1) Monte Carlo simulations of the light distribution within the breast tissue, (2) generation of optoacoustic signals by convolving N-shaped pressure signals from spherical voxels with the shape of individual transducers, and (3) back-projecting processed optoacoustic signals onto spherical surfaces for image reconstruction. Using the developed models we demonstrated the importance of the included spatial impulse response of the optoacoustic imaging system.


Journal of Biomedical Optics | 2010

Optoacoustic imaging of the prostate: development toward image-guided biopsy.

Mohammad A. Yaseen; Sergey A. Ermilov; Hans-Peter Brecht; Richard Su; André Conjusteau; Matthew P. Fronheiser; Brent Bell; Massoud Motamedi; Alexander A. Oraevsky

Optoacoustic (OA) tomography has demonstrated utility in identifying blood-rich malignancies in breast tissue. We describe the development and characterization of a laser OA imaging system for the prostate (LOIS-P). The system consists of a fiber-coupled Q-switched laser operating at 757 nm, a commercial 128-channel ultrasonic probe, a digital signal processor, and software that uses the filtered radial back-projection algorithm for image reconstruction. The system is used to reconstruct OA images of a blood-rich lesion induced in vivo in a canine prostate. OA images obtained in vivo are compared to images acquired using ultrasound, the current gold standard for guiding biopsy of the prostate. Although key structural features such as the urethra could be identified with both imaging techniques, a bloody lesion representing a highly vascularized tumor could only be clearly identified in OA images. The advantages and limitations of both forward and backward illumination modes are also evaluated by collecting OA images of phantoms simulating blood vessels within tissue. System resolution is estimated to be 0.2 mm in the radial direction of the acoustic array. The minimum detectable pressure signal is 1.83 Pa. Our results encourage further development toward a dual-modality OA/ultrasonic system for prostate imaging and image-guided biopsy.


Photoacoustics | 2015

Melanin nanoparticles as a novel contrast agent for optoacoustic tomography.

Anton Liopo; Richard Su; Alexander A. Oraevsky

We describe the synthesis and characterization of melanin-like nanoparticles (MNP) as novel contrast agents for optoacoustic tomography. Good dispersion stability of high concentration MNPs in different biological media was achieved with thiol-terminated methoxy-poly(ethylene glycol), which can be used for further functional conjugation. MNP-PEG were found biocompatible with human MCF-7 and 3T3 cells. Cell toxicity of MNPs was found lower than that of gold nanorods for concentrations that provide equal optical absorbance. Optoacoustic tomography images were obtained with Laser Optoacoustic Imaging System (LOIS-3D) from tubes filled with contrast agents and live mice. Imaging of tubes permitted verification of the system resolution <300 μm and sensitivity Δμa=0.03/cm under safe laser fluence of 20 mJ/cm2. Water suspensions of MNP demonstrated optoacoustic efficiency that is about equal to that of gold nanorods under conditions of equal optical absorption. We conclude that MNPs have the potential for biomedical imaging applications as optoacoustic contrast agents.


Journal of Biomedical Optics | 2012

Three-dimensional optoacoustic imaging as a new noninvasive technique to study long-term biodistribution of optical contrast agents in small animal models

Richard Su; Sergey A. Ermilov; Anton Liopo; Alexander A. Oraevsky

Abstract. We used a 3-D optoacoustic (OA) tomography system to create maps of optical absorbance of mice tissues contrasted with gold nanorods (GNRs). Nude mice were scanned before and after injection of GNRs at time periods varying from 1 to 192 h. Synthesized GNRs were purified from hexadecyltrimethylammonium bromide and coated with polyethylene glycol (PEG) to obtain GNR-PEG complexes suitable for in vivo applications. Intravenous administration of purified GNR-PEG complexes resulted in enhanced OA contrast of internal organs and blood vessels compared to the same mouse before injection of the contrast agent. Maximum enhancement of the OA images was observed 24 to 48 h postinjection, followed by a slow clearance trend for the remaining part of the studied period (eight days). We demonstrate that OA imaging with two laser wavelengths can be used for noninvasive, long-term studies of biological distribution of contrast agents.


Review of Scientific Instruments | 2009

Measurement of the spectral directivity of optoacoustic and ultrasonic transducers with a laser ultrasonic source

André Conjusteau; Sergey A. Ermilov; Richard Su; Hans-Peter Brecht; Matthew P. Fronheiser; Alexander A. Oraevsky

Comprehensive characterization of wideband ultrasonic transducers and specifically optoacoustic detectors is achieved through the analysis of their frequency response as a function of the incident angle. The tests are performed under well-defined, repeatable operating conditions. Backillumination of a blackened, acoustically matched planar surface with a short laser pulse creates an acoustic impulse which is used as a wideband ultrasonic source. Upon illumination with a short laser pulse, the bandwidth of our source shows a -6 dB point of 12 MHz and a low-frequency roll-off around 300 kHz. Using proprietary software, we examine thoroughly the planarity of the emitted wave front within a specified amplitude cutoff and phase incoherence. Analysis of the angular dependence of the frequency response yields invaluable directivity information about the detector under study: a necessary component toward accurate optoacoustic image reconstruction and quantitative tomography. The laser ultrasonic source we developed is the main feature of our directivity measurement setup. Due to its simplicity, it can easily be adapted to various calibration devices. This paper focuses on the development and characterization of the flatness and the bandwidth of our wideband ultrasonic source.

Collaboration


Dive into the Richard Su's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

André Conjusteau

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Mark A. Anastasio

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Anton Liopo

University of Texas Medical Branch

View shared research outputs
Top Co-Authors

Avatar

Kun Wang

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fatima Anis

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pamela M Otto

University of Texas Health Science Center at San Antonio

View shared research outputs
Researchain Logo
Decentralizing Knowledge