Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert M. Sutherland is active.

Publication


Featured researches published by Robert M. Sutherland.


Medical Imaging 2007: Physics of Medical Imaging | 2007

Iodine contrast cone beam CT imaging of breast cancer

Larry Partain; Stavros Prionas; Edward J. Seppi; Gary Virshup; Gerhard Roos; Robert M. Sutherland; John M. Boone

An iodine contrast agent, in conjunction with an X-ray cone beam CT imaging system, was used to clearly image three, biopsy verified, cancer lesions in two patients. The lesions were approximately in the 10 mm to 6 mm diameter range. Additional regions were also enhanced with approximate dimensions down to 1 mm or less in diameter. A flat panel detector, with 194 μm pixels in 2 x 2 binning mode, was used to obtain 500 projection images at 30 fps with an 80 kVp X-ray system operating at 112 mAs, for an 8-9 mGy dose - equivalent to two view mammography for these women. The patients were positioned prone, while the gantry rotated in the horizontal plane around the uncompressed, pendant breasts. This gantry rotated 360 degrees during the patients 16.6 sec breath hold. A volume of 100 cc of 320 mg/ml iodine-contrast was power injected at 4 cc/sec, via catheter into the arm vein of the patient. The resulting 512 x 512 x 300 cone beam CT data set of Feldkamp reconstructed ~(0.3 mm)3 voxels were analyzed. An interval of voxel contrast values, characteristic of the regions with iodine contrast enhancement, were used with surface rendering to clearly identify up to a total of 13 highlighted volumes. This included the three largest lesions, that were previously biopsied and confirmed to be malignant. The other ten highlighted regions, of smaller diameters, are likely areas of increased contrast trapping unrelated to cancer angiogenesis. However the technique itself is capable of resolving lesions that small.


Archive | 2002

Method and system for monitoring breathing activity of a subject

Andrew G. Jeung; Hassan Mostafavi; Majid L. Riaziat; Robert M. Sutherland; George A. Zdasiuk


Archive | 2007

Contrast-enhanced cone beam X-ray imaging, evaluation, monitoring and treatment delivery

Larry Partain; Stavros Prionas; Edward J. Seppi; Robert M. Sutherland; David Humber; Hassan Mostafavi; Felix Fernando; John M. Boone


Archive | 2001

Multipurpose template and needles for the delivery and monitoring of multiple minimally invasive therapies

Majid L. Riaziat; George A. Zdasiuk; Robert M. Sutherland; Andrew G. Jeung; Steven Bandy


Archive | 2000

Radiation sensitive liposomes

David F. O'brien; Kathy A. Mcgovern; Bruce Bondurant; Robert M. Sutherland


Archive | 2002

Method and system for monitoring breathing activity of an infant

Andrew G. Jeung; Hassan Mostafavi; Majid L Riaziat; Robert M. Sutherland; G. Zdasiuk


Archive | 2003

Localization of a sensor device in a body

Robert M. Sutherland; G. Zdasiuk; Hassan Mostafavi


Archive | 2012

PREPARATIVE REGIMEN FOR ENGRAFTMENT, GROWTH AND DIFFERENTIATION OF NON-HEMATOPOEITIC CELLS IN VIVO AFTER TRANSPLANTATION

Chandan Guha; Robert M. Sutherland; Alan Alfieri; Jayanta Roy-Chowdury


Archive | 2008

Preparative regimen for engraftment, growth and differentiation of non-hematopoeitic cells in vivo

Chandan Guha; Robert M. Sutherland; Alan A. Alfieri; Jayanta Roy-Chowdury


International Journal of Radiation Oncology Biology Physics | 2006

Radiation-enhanced immune response to cancer : Workshop, anaheim, Ca, april 17, 2005

Robert M. Sutherland

Collaboration


Dive into the Robert M. Sutherland's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John M. Boone

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge