Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ron Neal is active.

Publication


Featured researches published by Ron Neal.


Review of Scientific Instruments | 2002

A high sensitivity refractometer based upon a long period grating Mach-Zehnder interferometer

Thomas D.P. Allsop; R. Reeves; David J. Webb; Ian Bennion; Ron Neal

A low cost interrogation scheme is demonstrated for a refractometer based on an in-line fiber long period grating (LPG) Mach–Zehnder interferometer. Using this interrogation scheme the minimum detectable change in refractive index of ?n ~ 1.8×10-6 is obtained, which is the highest resolution achieved using a fiber LPG device, and is comparable to precision techniques used in the industry including high performance liquid chromatography and ultraviolet spectroscopy.


IEEE Transactions on Instrumentation and Measurement | 2004

Bending and orientational characteristics of long period gratings written in D-shaped optical fiber [directional bend sensors]

Thomas D.P. Allsop; Andrew Gillooly; Vladimir Mezentsev; T. Earthgrowl-Gould; Ron Neal; David J. Webb; Ian Bennion

Long period gratings (LPGs) were written into a D-shaped single-mode fiber. These LPGs were subjected to a range of curvatures, and it was found that as curvature increased, there was increasingly strong coupling to certain higher order cladding modes without the usual splitting of the LPGs stopbands. A bend-induced stopband yielded a spectral sensitivity of 12.55 nm/spl middot/m for curvature and 2.2/spl times/10/sup -2/ nm/spl deg/C/sup -1/ for temperature. It was also found that the wavelength separation between adjacent bend-induced stopbands varied linearly as a function of curvature. Blue and red wavelength shifts of the stopbands were observed as the sensor was rotated around a fixed axis for a given curvature; thus, in principle, this sensor could be used to obtain bending and orientational information. The behavior of the stopbands was successfully modeled using a finite element approach.


Optics Express | 2011

Characterisation and performance of a Terfenol-D coated femtosecond laser inscribed optical fibre Bragg sensor with a laser ablated microslot for the detection of static magnetic fields

Graham N. Smith; Thomas D.P. Allsop; Kyriacos Kalli; Charalambos Koutsides; Ron Neal; Kate Sugden; Philip Culverhouse; Ian Bennion

We present a novel device for the characterisation of static magnetic fields through monitoring wavelength shifts of femtosecond inscribed fibre Bragg grating and micromachined slot, coated with Terfenol-D. The device was sensitive to static magnetic fields and can be used as a vectoral sensor for the detection of magnetic fields as low as 0.046 mT with a resolution of ± 0.3mT in transmission and ± 0.7mT in reflection. The use of a femtosecond laser to both inscribe the FBGs and micromachine the slot in a single stage prior to coating the device significantly simplifies the fabrication.


Applied Optics | 2007

Generation of infrared surface plasmon resonances with high refractive index sensitivity utilizing tilted fiber Bragg gratings

Thomas D.P. Allsop; Ron Neal; Saeed Rehman; David J. Webb; D.J. Mapps; Ian Bennion

We demonstrate the use of tilted fiber gratings to assist the generation of localized infrared surface plasmons with short propagation lengths and a sensitivity of dlambda/dn = 3,365 nm in the aqueous index regime. It was also found that the resonances could be spectrally tuned over 1,000 nm at the same spatial region with high coupling efficiency (in excess of 25 dB) by altering the polarization of the light illuminating the device.


Journal of The Optical Society of America B-optical Physics | 2008

Characterization of infrared surface plasmon resonances generated from a fiber-optical sensor utilizing tilted Bragg gratings

Thomas D.P. Allsop; Ron Neal; Saeed Rehman; David J. Webb; D.J. Mapps; Ian Bennion

We demonstrate the use of tilted fiber gratings to assist with the generation of infrared surface plasmons on a metal film coating the flat of a D-shaped fiber. The wavelength of the strong (>25 dB) resonance is tunable over similar to 1000 nm by adjusting the polarization state of the light and is highly sensitive to the refractive index of any aqueous medium surrounding the fiber (sensitivity= 3365 nm).


Applied Optics | 2009

Exploitation of multilayer coatings for infrared surface plasmon resonance fiber sensors

Thomas D.P. Allsop; Ron Neal; Chengbo Mou; Patrick R. Brown; Sayah Saied; Saeed Rehman; Kyriacos Kalli; David J. Webb; J.L. Sullivan; Desmond J. Mapps; Ian Bennion

We demonstrate surface plasmon resonance (SPR) fiber devices based upon ultraviolet inscription of a grating-type structure into both single-layered and multilayered thin films deposited on the flat side of a lapped D-shaped fiber. The single-layered devices were fabricated from germanium, while the multilayered ones comprised layers of germanium, silica, and silver. Some of the devices operated in air with high coupling efficiency in excess of 40 dB and an estimated index sensitivity of Delta lambda/Delta n=90 nm from 1 to 1.15 index range, while others provided an index sensitivity of Delta lambda/Delta n=6790 nm for refractive indices from 1.33 to 1.37.


Light-Science & Applications | 2016

Photonic gas sensors exploiting directly the optical properties of hybrid carbon nanotube localized surface plasmon structures

Thomas D.P. Allsop; Raz Arif; Ron Neal; Kyriacos Kalli; Vojtech Kundrát; Aleksey Rozhin; Phil F. Culverhouse; David J. Webb

We investigate the modification of the optical properties of carbon nanotubes (CNTs) resulting from a chemical reaction triggered by the presence of a specific compound (gaseous carbon dioxide (CO2)) and show this mechanism has important consequences for chemical sensing. CNTs have attracted significant research interest because they can be functionalized for a particular chemical, yielding a specific physical response which suggests many potential applications in the fields of nanotechnology and sensing. So far, however, utilizing their optical properties for this purpose has proven to be challenging. We demonstrate the use of localized surface plasmons generated on a nanostructured thin film, resembling a large array of nano-wires, to detect changes in the optical properties of the CNTs. Chemical selectivity is demonstrated using CO2 in gaseous form at room temperature. The demonstrated methodology results additionally in a new, electrically passive, optical sensing configuration that opens up the possibilities of using CNTs as sensors in hazardous/explosive environments.


IEEE Journal of Quantum Electronics | 2012

Formation and Characterization of Ultra-Sensitive Surface Plasmon Resonance Sensor Based Upon a Nano-Scale Corrugated Multi-Layered Coated D-Shaped Optical Fiber

Thomas D.P. Allsop; Ron Neal; Chengbo Mou; Kyriacos Kalli; Sayah Saied; Saeed Rehman; David J. Webb; Philip Culverhouse; J.L. Sullivan; Ian Bennion

We present experimental results on the performance of a series of coated, D-shaped optical fiber sensors that display high spectral sensitivities to external refractive index. Sensitivity to the chosen index regime and coupling of the fiber core mode to the surface plasmon resonance (SPR) is enhanced by using specific materials as part of a multi-layered coating. We present strong evidence that this effect is enhanced by post ultraviolet radiation of the lamellar coating that results in the formation of a nano-scale surface relief corrugation structure, which generates an index perturbation within the fiber core that in turn enhances the coupling. We have found reasonable agreement when we modeling the fiber device. It was found that the SPR devices operate in air with high coupling efficiency in excess of 40 dB with spectral sensitivities that outperform a typical long period grating, with one device yielding a wavelength spectral sensitivity of 12000 nm/RIU in the important aqueous index regime. The devices generate SPRs over a very large wavelength range, (visible to 2 μm) by alternating the polarization state of the illuminating light.


Measurement Science and Technology | 2010

Low refractive index gas sensing using a surface plasmon resonance fibre device

Thomas D.P. Allsop; Ron Neal; Edward Davies; Chengbo Mou; Peter Bond; Saeed Rehman; Kyriacos Kalli; David J. Webb; P. Calverhouse; Ian Bennion

A series of surface plasmonic fibre devices were fabricated using multiple coatings deposited on a lapped section of a single mode fibre. Coupling from the guided mode to surface plasmons was promoted following UV laser irradiation of the coated region through a phase mask, which generated a surface relief grating structure. The devices showed high spectral sensitivities and strong coupling for low refractive indices as compared to other grating-type fibre devices. The plasmonic devices were used to detect the variation in the refractive indices of alkane gases with measured wavelength and coupling sensitivity to index of 3400 nm RIU-1 and 8300 dB RIU-1, respectively. As a demonstration of the performance of these gas sensors, a minimum concentration of 2% by volume of butane in ethane was achieved.


Optics Express | 2013

Physical characteristics of localized surface plasmons resulting from nano-scale structured multi-layer thin films deposited on D-shaped optical fiber

Thomas D.P. Allsop; Ron Neal; Martin Dvorak; Kyriacos Kalli; Alex Rozhin; David J. Webb

Novel surface plasmonic optical fiber sensors have been fabricated using multiple coatings deposited on a lapped section of a single mode fiber. UV laser irradiation processing with a phase mask produces a nano-scaled surface relief grating structure resembling nano-wires. The resulting individual corrugations produced by material compaction are approximately 20 μm long with an average width at half maximum of 100 nm and generate localized surface plasmons. Experimental data are presented that show changes in the spectral characteristics after UV processing, coupled with an overall increase in the sensitivity of the devices to surrounding refractive index. Evidence is presented that there is an optimum UV dosage (48 joules) over which no significant additional optical change is observed. The devices are characterized with regards to change in refractive index, where significantly high spectral sensitivities in the aqueous index regime are found, ranging up to 4000 nm/RIU for wavelength and 800 dB/RIU for intensity.

Collaboration


Dive into the Ron Neal's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kyriacos Kalli

Higher Technical Institute of Cyprus

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge