Ruan Fangming
Guizhou Normal University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ruan Fangming.
international symposium on electromagnetic compatibility | 2016
Ruan Fangming; Zhang Chao; Xiao Wenjun; Tian Maochao; David Pommerenke; Su Ming; Zhi Qi-Jun; Wang Heng; Wang Yi; Yang Xiaohong; Zhang Junhua; Li Sheng
A new measurement system has been created for investigation of non-contact electrostatic discharge(ESD). An automotive control section of gas pressure was designed to meet the requirement of the new invented ESD measurement system. Experiment result with the new ESD measurement system shown that gas pressure and relative humidity have distinctive effect on peak value, rise/fall time of discharge current. Some possible mechanism was discussed for the influence of gas pressure and relative humidity. On-off state of solenoid valve was decided once received feedback signal from sensor through applying PID algorithm to output PWM impulse. Desired stable value can be obtained and improved performance of the new ESD measurement system.
asia pacific conference on environmental electromagnetics | 2015
Liu Xiaoxiao; Ruan Fangming; Zhang Junhua; Tomasz Dlugosz; Xiao Wenjun; Xun Xiaoping; Yang Xiaohong; You Xiaojin; Jiang Yuanyuan; Chen Erpeng
Electrostatic Discharge (ESD) parameters of breakdown voltage, current, electric field, magnetic field, arc length, rise slope, shown distinctive variation because of effect from environment multiple factors of gas pressure, electrode speed to the target, temperature, humidity, type of gas. Measurement results have obviously low repeatability in non-contacted electrostatic discharge due to effect of surrounding multiple factors. Investigation of ESD parameter low repeatability were performed with methods of theory and experiment because of its much important theory and practice significance to understand ESD properties and to protect electronic systems from ESD harm. Discharge peak values variation caused by relative humidity were described and discussed. Analysis was given on possible mechanism of low repeatability of ESD parameters.
asia pacific conference on environmental electromagnetics | 2015
Fu Zhao; Qiu Yunfeng; Chen Huining; Xiao Wenjun; Ruan Fangming; Tomasz Dloguzs; Zhang Chao; Liu Xiaoxiao; Yang Xiaohong; Zhang Junhua; You Xiaojin; Jiang Yuanyuan; Gong Boxiang
Based on requirement of new invented ESD measurement system, detection design of humidity-controlled was proposed. Small gap electrostatic discharge (ESD) is greatly affected by factors of electrode moving speed and humidity and results in discrete characteristic of discharge parameters. Humidity test system design was given based on the STM32 in a sealed box with smart control PID algorithm. The design may promote investigation on the measurement system of multiple factor effect on discharge parameters, obtained a more convenience humidity control system.
Archive | 2013
Ruan Fangming; Yang Xiangdong; Li Zhanglun; Zhou Feng; Meng Yang; Wang Xiang
Chinese Journal of Radio Science | 2011
Ruan Fangming
international symposium on electromagnetic compatibility | 2017
Huang Jun; Ruan Fangming; Su Ming; Wang Heng; Yang Xiangdong; David Pommerenke
international symposium on electromagnetic compatibility | 2017
Lou Shichao; Cai Xiaobing; Ruan Fangming; Su Ming; Ji Qizheng; Wang Heng; Yang Xiangdong; Gao Zhiliang; David Pommerenke
IEEE Conference Proceedings | 2016
Lou Shichao; Ruan Fangming; Su Ming; Wang Tuo; Wang Heng; Xiao Wenjun; Zhi Qi-Jun
Dianbo Kexue Xuebao | 2016
Zhou Kui; Ruan Fangming; Zhang Jing; Su Ming; Wang Heng
Dianbo Kexue Xuebao | 2016
Zhou Kui; Ruan Fangming; Zhang Jing; Su Ming; Wang Heng