Featured researches published by Rupak K. Banerjee.


Nephrology Dialysis Transplantation | 2011

Severe venous neointimal hyperplasia prior to dialysis access surgery

Timmy Lee; Vibha Chauhan; Mahesh Krishnamoorthy; Yang Wang; Lois J. Arend; Meenakshi J. Mistry; Mahmoud El-Khatib; Rupak K. Banerjee; Rino Munda; Prabir Roy-Chaudhury

BACKGROUND Venous neointimal hyperplasia is the most common cause of arteriovenous (AV) fistula and graft dysfunction following dialysis access surgery. However, the pathogenetic impact of pre-existing venous neointimal hyperplasia at the time of AV access creation on final clinical success is currently unknown in the setting of advanced chronic kidney disease (CKD) and end-stage renal disease (ESRD) patients. The aim of this study was to perform a detailed histological, morphometric, and immunohistochemical analysis of vein specimens in advanced CKD and ESRD patients collected at the time of new vascular access placement. METHODS Vein samples from 12 patients were collected at the time of AV access creation near the site of AV anastomosis. Histological, immunohistochemistry and morphometric studies were performed on these vein samples. RESULTS Examination of the tissue specimens obtained at the time of surgery showed neointimal hyperplasia in 10 of 12 specimens, ranging from minimal to very severe. The majority of cells within the neointima were myofibroblasts with a minority of contractile smooth muscle cells present. CONCLUSION Our work represents a detailed description of the morphometric and cellular phenotypic lesions present in the veins of CKD and ESRD patients, prior to dialysis access placement. These studies (i) suggest the future possibility of a new predictive marker (pre-existing venous neointimal hyperplasia) for AV dialysis access dysfunction and (ii) open the door for the future development of novel local therapies for optimization of the venous substrate on which the dialysis access is created.


Nephrology Dialysis Transplantation | 2009

Cellular phenotypes in human stenotic lesions from haemodialysis vascular access

Prabir Roy-Chaudhury; Yang Wang; Mahesh Krishnamoorthy; Jianhua Zhang; Rupak K. Banerjee; Rino Munda; Sue Heffelfinger; Lois J. Arend

BACKGROUND Haemodialysis vascular access dysfunction (due to venous stenosis and thrombosis) is a leading cause of hospitalization and morbidity. The aim of the current study was to identify the specific cell types present within stenotic tissue samples from patients with AV fistula and graft failure. METHODS Discarded tissue segments were collected from the stenotic portions (usually near the graft-vein anastomosis or the AV anastomosis) of 23 dialysis grafts and 20 AV fistulae, and examined for expression of smooth muscle alpha actin, desmin, vimentin and a macrophage marker. RESULTS The majority of cells within the venous neointima (both grafts and fistulae) were myofibroblasts, with a smaller number of desmin positive smooth muscle cells. The graft neointima had a similar cellular phenotype, albeit without any desmin positive contractile smooth muscle cells. The majority of cells within the PTFE graft material were macrophages. Analysis of sequential sections revealed the presence of fibroblasts within the venous neointima and intragraft region. CONCLUSIONS Our results demonstrate that contractile smooth muscle cells, myofibroblasts, fibroblasts and macrophages all play a role in the pathogenesis of dialysis access dysfunction (grafts and fistulae). Targeting these specific cell types might result in the development of novel therapeutic paradigms for haemodialysis vascular access dysfunction.


Physics in Medicine and Biology | 2007

HIFU procedures at moderate intensities : effect of large blood vessels

Prasanna Hariharan; Matthew R. Myers; Rupak K. Banerjee

A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is based upon the linearized KZK equation and the bioheat equation in tissue. In the blood vessel the momentum and energy equations are satisfied. The model is first validated in a tissue phantom, to verify the absence of bubble formation and nonlinear effects. Temperature rise and lesion-volume calculations are then shown for different beam locations and orientations relative to a large vessel. Both single and multiple ablations are considered. Results show that when the vessel is located within about a beam width (few mm) of the ultrasound beam, significant reduction in lesion volume is observed due to blood flow. However, for gaps larger than a beam width, blood flow has no major effect on the lesion formation. Under the clinically representative conditions considered, the lesion volume is reduced about 40% (relative to the no-flow case) when the beam is parallel to the blood vessel, compared to about 20% for a perpendicular orientation. Procedures involving multiple ablation sites are affected less by blood flow than single ablations. The model also suggests that optimally focused transducers can generate lesions that are significantly larger (>2 times) than the ones produced by highly focused beams.


Annals of Biomedical Engineering | 2003

A Computational Model of Direct Interstitial Infusion of Macromolecules into the Spinal Cord

Malisa Sarntinoranont; Rupak K. Banerjee; Russell R. Lonser; Paul F. Morrison

AbstractConvection-enhanced interstitial infusion can deliver macromolecular drugs to large tissue volumes of the central nervous system. To characterize infusion into the spinal cord, an image-based three-dimensional finite element model of the rat spinal cord was developed. The model incorporated convection and diffusion through white and gray matter, including anisotropic transport due to alignment of white matter tracts. Spatial and temporal distribution of the marker substance albumin within the interstitial space was determined. Consistent with previous experiments, predicted distribution was highly anisotropic. Infusing into the dorsal column, albumin was primarily confined to white matter with limited penetration into adjacent gray matter. Distribution was determined primarily by the ratio of fiber-parallel to fiber-perpendicular hydraulic conductivity tensor components (kwm-z/kwm-x), the ratio of transverse white and gray matter hydraulic conductivity (kwm-x/kgm), and tissue porosity. Fits to previous experimental measures of axial and transverse spread, distribution volume, and protein recovery yielded an optimum kwm-z/kwm-x of approximately 20 at 0.1 μl/min. kwm-x/kgm of 100 was sufficient to match experimental transverse distribution data. Best fits to data at 0.1 μl/min were achieved by porosities characteristic of moderate edema (e.g., 0.26). Distribution also varied with catheter placement with more medial placement resulting in greater distribution volumes.


Kidney International | 2008

Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula

Mahesh Krishnamoorthy; Rupak K. Banerjee; Yang Wang; Jianhua Zhang; Abhijit Sinha Roy; Saeb F. Khoury; Lois J. Arend; S.M. Rudich; Prabir Roy-Chaudhury

Venous stenosis is a significant problem in arteriovenous fistulae, likely due to anatomical configuration and wall shear stress profiles. To identify linkages between wall shear stress and the magnitude and pattern of vascular stenosis, we produced curved and straight fistulae in a pig model. A complete wall stress profile was calculated for the curved configuration and correlated with luminal stenosis. Computer modeling techniques were then used to derive a wall shear stress profile for the straight arteriovenous fistula. Differences in the wall shear stress profile of the curved and straight fistula were then related to histological findings. There was a marked inverse correlation between the magnitude of wall shear stress within different regions of the curved arteriovenous fistula and luminal stenosis in these same regions. There were also significantly greater differences in wall shear stress between the outer and inner walls of the straight as compared to curved arteriovenous fistula, which translated into a more eccentric histological pattern of intima-media thickening. Our results suggest a clear linkage between anatomical configuration, wall shear stress profiles, and the pattern of luminal stenosis and intima-media thickening in a pig model of arteriovenous fistula stenosis. These results suggest that fistula failure could be reduced by using computer modeling prior to surgical placement to alter the anatomical and, consequently, the wall shear stress profiles in an arteriovenous fistula.


Journal of Biomechanical Engineering-transactions of The Asme | 2000

Physiological flow simulation in residual human stenoses after coronary angioplasty.

Rupak K. Banerjee; Lloyd H. Back; Martin R. Back; Young I. Cho

To evaluate the local hemodynamic implications of coronary artery balloon angioplasty, computational fluid dynamics (CFD) was applied in a group of patients previously reported by [Wilson et al. (1988), 77, pp. 873-885] with representative stenosis geometry post-angioplasty and with measured values of coronary flow reserve returning to a normal range (3.6 +/- 0.3). During undisturbed flow in the absence of diagnostic catheter sensors within the lesions, the computed mean pressure drop delta p was only about 1 mmHg at basal flow, and increased moderately to about 8 mmHg for hyperemic flow. Corresponding elevated levels of mean wall shear stress in the midthroat region of the residual stenoses, which are common after angioplasty procedures, increased from about 60 to 290 dynes/cm2 during hyperemia. The computations (Ree approximately equal to 100-400; alpha e = 2.25) indicated that the pulsatile flow field was principally quasi-steady during the cardiac cycle, but there was phase lag in the pressure drop-mean velocity (delta p - u) relation. Time-averaged pressure drop values, delta p, were about 20 percent higher than calculated pressure drop values, delta ps, for steady flow, similar to previous in vitro measurements by Cho et al. (1983). In the throat region, viscous effects were confined to the near-wall region, and entrance effects were evident during the cardiac cycle. Proximal to the lesion, velocity profiles deviated from parabolic shape at lower velocities during the cardiac cycle. The flow field was very complex in the oscillatory separated flow reattachment region in the distal vessel where pressure recovery occurred. These results may also serve as a useful reference against catheter-measured pressure drops and velocity ratios (hemodynamic endpoints) and arteriographic (anatomic) endpoints post-angioplasty. Some comparisons to previous studies of flow through stenoses models are also shown for perspective purposes.


Biomedical Engineering Online | 2008

Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study

Rupak K. Banerjee; Koustubh D. Ashtekar; Tarek Helmy; Mohamed Effat; Lloyd H. Back; Saeb F. Khoury

BackgroundThe severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses.MethodsThree models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (η) was calculated as the ratio of pressure recovery coefficient and the area blockage.ResultsThe mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (~80%) area stenosis, which is between moderate (~65%) and severe (~90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 ± 3.3 to 287 ± 52, n = 3, p < 0.01) and mean η decreased (0.54 ± 0.04 to 0.37 ± 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion.ConclusionThe wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.


Journal of Biomechanics | 2009

Influence of coronary collateral flow on coronary diagnostic parameters: An in vitro study

Srikara V. Peelukhana; Lloyd H. Back; Rupak K. Banerjee

Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered. This effect of downstream collaterals on different diagnostic parameters is studied using a physiological representative in vitro coronary flow-loop. The three diagnostic parameters tested are fractional flow reserve (FFR), lesion flow coefficient (LFC), and pressure drop coefficient (CDP). The latter two were discussed in recent publications by our group (Banerjee et al., 2007, 2008, 2009). They are evaluated for three different severities of stenosis and tested for possible misinterpretation in the presence of variable collateral flows. Pressure and flow are measured with and without downstream collaterals. The diagnostic parameters are then calculated from these readings. In the case of intermediate stenosis (80% area blockage), FFR and LFC increased from 0.74 to 0.77 and 0.58 to 0.62, respectively, for no collateral to fully developed collateral flow. Also, CDP decreased from 47 to 42 for no collateral to fully developed collateral flow. These changes in diagnostic parameters might lead to erroneous postponement of coronary intervention. Thus, variability in diagnostic parameters for the same stenosis might lead to misinterpretation of stenosis severity in the presence of operating downstream collaterals.


Journal of Biomechanics | 2011

Influence of arterial wall-stenosis compliance on the coronary diagnostic parameters

Bhaskar Chandra Konala; Ashish Das; Rupak K. Banerjee

Functional diagnostic parameters such as Fractional Flow Reserve (FFR), which is calculated from pressure measurements across stenosed arteries, are often used to determine the functional severity of coronary artery stenosis. This study evaluated the effect of arterial wall-stenosis compliance, with limiting scenarios of stenosis severity, on the diagnostic parameters. The diagnostic parameters considered in this study include an established index, FFR and two recently developed parameters: Pressure Drop Coefficient (CDP) and Lesion Flow Coefficient (LFC). The parameters were assessed for rigid artery (RR; signifying high plaque elasticity), compliant artery with calcified plaque (CC; intermediate plaque elasticity) and compliant artery with smooth muscle cell proliferation (CS; low plaque elasticity), with varying degrees of epicardial stenosis. A hyperelastic Mooney-Rivlin model was used to model the arterial wall and plaque materials. Blood was modeled as a shear thinning, non-Newtonian fluid using the Carreau model. The arterial wall compliance was evaluated using the finite element method. The present study found that, with an increase in stenosis severity, FFR decreased whereas CDP and LFC increased. The cutoff value of 0.75 for FFR was observed at 78.7% area stenosis for RR, whereas for CC and CS the cutoff values were obtained at higher stenosis severities of 81.3% and 82.7%, respectively. For a fixed stenosis, CDP value decreased and LFC value increased with a decrease in plaque elasticity (RR to CS). We conclude that the differences in diagnostic parameters with compliance at intermediate stenosis (78.7-82.7% area blockage) could lead to misinterpretation of the stenosis severity.


American Journal of Physiology-heart and Circulatory Physiology | 2011

Influence of heart rate on fractional flow reserve, pressure drop coefficient, and lesion flow coefficient for epicardial coronary stenosis in a porcine model

Kranthi K. Kolli; Rupak K. Banerjee; Srikara V. Peelukhana; Tarek Helmy; Massoud A. Leesar; Imran Arif; Eric W. Schneeberger; Dwight Hand; Paul Succop; William Gottliebson; Mohamed Effat

A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.

Collaboration


Dive into the Rupak K. Banerjee's collaboration.

Top Co-Authors

Avatar

Lloyd H. Back

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mohamed Effat

University of Cincinnati

View shared research outputs
Top Co-Authors

Avatar

Matthew R. Myers

Center for Devices and Radiological Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tarek Helmy

University of Cincinnati

View shared research outputs
Top Co-Authors

Avatar

Prasanna Hariharan

Food and Drug Administration

View shared research outputs
Top Co-Authors

Avatar

Massoud A. Leesar

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

William Gottliebson

Cincinnati Children's Hospital Medical Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge