S. R. Lawrie
Rutherford Appleton Laboratory
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by S. R. Lawrie.
Review of Scientific Instruments | 2012
D. C. Faircloth; S. R. Lawrie; C. Gabor; Alan Letchford; M. O. Whitehead; T. Wood; M. Perkins
The aim of the front end test stand project is to demonstrate that chopped low energy H(-) beams of high quality can be produced. The beam line currently consists of the ion source, a 3 solenoid low energy beam transport and a suite of diagnostics. A brief status report of the radio frequency quadrupole is given. This paper details the work to optimize the ion source performance. A new high power pulsed discharge power supply with greater reliability has been developed to allow long term, stable operation at 50 Hz with a 60 A, 2.2 ms discharge pulse and up to 100 A at 1.2 ms. The existing extraction power supply has been modified to operate up to 22 kV. Results from optical spectroscopy measurements and their application to source optimization are summarized. Source emittances and beam currents of 60 mA are reported.
Review of Scientific Instruments | 2010
D. C. Faircloth; S. R. Lawrie; Alan Letchford; C. Gabor; P. Wise; M. O. Whitehead; T. Wood; M. Westall; D.J.S. Findlay; M. Perkins; P. Savage; D. A. Lee; J. K. Pozimski
The aim of the front end test stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a 60 mA Penning Surface Plasma Ion Source, a three solenoid low energy beam transport, a 3 MeV radio frequency quadrupole, a chopper, and a comprehensive suite of diagnostics. This paper details the design and initial performance of the ion source and the laser profile measurement system. Beam current, profile, and emittance measurements are shown for different operating conditions.
Review of Scientific Instruments | 2010
S. R. Lawrie; D. C. Faircloth; Alan Letchford; C. Gabor; J. K. Pozimski
In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H(-) ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.
NEGATIVE IONS, BEAMS AND SOURCES: Proceedings of the 1st International Symposium#N#on Negative Ions, Beams and Sources | 2009
S. R. Lawrie; Dan Faircloth; Alan Letchford; M. Westall; M. O. Whitehead; T. Wood; J. K. Pozimski
A full 3D electromagnetic finite element analysis and particle tracking study is undertaken of the ISIS Penning surface plasma H− ion source. The extraction electrode, 90° analysing magnet, post‐extraction acceleration gap and 700 mm of drift space have been modelled in CST Particle Studio 2008 to study the beam acceleration and transport at all points in the system. The analyzing magnet is found to have a sub‐optimal field index, causing beam divergence and contributing the beam loss. Different magnet pole piece geometries are modelled and the effects of space charge investigated. The best design for the analysing magnet involves a shallower intersection angle and larger separation of the pole faces. This provides radial focusing to the beam, leading to less collimation. Three new sets of magnet poles are manufactured and tested on the Ion Source Development Rig to compare with predictions.
Review of Scientific Instruments | 2014
S. R. Lawrie; Dan Faircloth; Alan Letchford; M. Perkins; M. O. Whitehead; T. Wood; C. Gabor; J. J. Back
The ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK uses a Penning surface plasma negative hydrogen ion source. Upgrade options for the ISIS accelerator system demand a higher current, lower emittance beam with longer pulse lengths from the injector. The Front End Test Stand is being constructed at RAL to meet the upgrade requirements using a modified ISIS ion source. A new 10% duty cycle 25 kV pulsed extraction power supply has been commissioned and the first meter of 3 MeV radio frequency quadrupole has been delivered. Simultaneously, a Vessel for Extraction and Source Plasma Analyses is under construction in a new laboratory at RAL. The detailed measurements of the plasma and extracted beam characteristics will allow a radical overhaul of the transport optics, potentially yielding a simpler source configuration with greater output and lifetime.
Review of Scientific Instruments | 2012
C. Gabor; J. J. Back; Dan Faircloth; Z. Izaola; S. R. Lawrie; Alan Letchford
The Front End Test Stand (FETS) is located at Rutherford Appleton Laboratory and aims for a high current, fast chopped 3 MeV H(-) ion beam suitable for future high power proton accelerators like ISIS upgrade. The main components of the front end are the Penning ion source, a low energy beam transport line, an radio-frequency quadrupole (RFQ) and a medium energy beam transport (MEBT) providing also a chopper section and rebuncher. FETS is in the stage of commissioning its low energy beam transport (LEBT) line consisting of three solenoids. The LEBT has to transport an H(-) high current beam (up to 60 mA) at 65 keV. This is the injection energy of the beam into the RFQ. The main diagnostics are slit-slit emittance scanners for each transversal plane. For optimizing the matching to the RFQ, experiments have been performed with a variety of solenoid settings to better understand the actual beam transport. Occasionally, source parameters such as extractor slit width and beam energy were varied as well. The paper also discusses simulations based on these measurements.
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES | 2011
Dan Faircloth; S. R. Lawrie; Alan Letchford; C. Gabor; M. O. Whitehead; T. Wood; M. Perkins
The aim of the Front End Test Stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a high power Penning Surface Plasma Ion Source, a 3 solenoid LEBT, a 3 MeV RFQ, a chopper and a comprehensive suite of diagnostics. This paper briefly outlines the status of the project, hardware installation and modifications. Results from experiments running the H− ion source at 2 ms pulse length are detailed: the discharge current is varied between 20 A and 50 A. The discharge repetition rate is varied between 12.5 and 50 Hz. Hydrogen and Caesium vapour flow rates are varied. The effect of electrode surface temperature and beam current droop are discussed. Peak beam currents of over 60 mA for 2 ms pulse length can be achieved. Normalised r.m.s emittances of 0.3 πmm.mrads at the exit of the LEBT are presented for different source conditions.
Review of Scientific Instruments | 2016
T. Wood; Dan Faircloth; S. R. Lawrie; Alan Letchford; M. O. Whitehead; T. Pike; M. Perkins
With the introduction of a new low energy beams group at ISIS, the decision was taken to expand the ion source area. This paper will explain what actions were taken, how this has improved the present working environment and how the space will be used to accommodate a medium energy beam transport (MEBT) section after the existing radio-frequency quadrupole. The MEBT will incorporate three 202.5 MHz re-bunching cavities and will achieve a transmission of 96% with minimal emittance growth.
Review of Scientific Instruments | 2016
S. R. Lawrie; Dan Faircloth; Alan Letchford; M. O. Whitehead; T. Wood
A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H(-) beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10(21) m(-3), whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.
Review of Scientific Instruments | 2010
C. Gabor; D. C. Faircloth; D. A. Lee; S. R. Lawrie; Alan Letchford; J. K. Pozimski
A front end is currently under construction consisting of a H(-) Penning ion source (65 keV, 60 mA), low energy beam transport (LEBT), and radio frequency quadrupole (3 MeV output energy) with a medium energy beam transport suitable for high power proton applications. Diagnostics can be divided either in destructive techniques such as beam profile monitor, pepperpot, slit-slit emittance scanner (preferably used during commissioning) or nondestructive, permanently installed devices such as photodetachment-based techniques. Another way to determine beam distributions is a scintillator with charge-coupled device camera. First experiments have been performed to control the beam injection into the LEBT. The influence of beam parameters such as particle energy and space-charge compensation on the two-dimensional distribution and profiles will be presented.