Sadeeq Ali
University of Malaya
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sadeeq Ali.
Biomedical Engineering Online | 2014
Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Nooranida Arifin; Wan Abu Bakar Wan Abas
BackgroundGood prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems).MethodsAll the suspension systems were tested (tensile testing machine) in terms of the degree of the shear strength and the patient’s comfort. Nine transtibial amputees participated in this study. The patients were asked to use four different suspension systems. Afterwards, each participant completed a questionnaire for each system to evaluate their comfort. Furthermore, the systems were compared in terms of the cost.ResultsThe maximum tensile load that the new system could bear was 490 N (SD, 5.5) before the system failed. Pin/lock, magnetic and suction suspension systems could tolerate loads of580 N (SD, 8.5), 350.9 (SD, 7) and 310 N (SD, 8.4), respectively. Our subjects were satisfied with the new hook and loop system, particularly in terms of easy donning and doffing. Furthermore, the new system is considerably cheaper (35 times) than the current locking systems in the market.ConclusionsThe new suspension system could successfully retain the prosthesis on the residual limb as a good alternative for lower limb amputees. In addition, the new system addresses some problems of the existing systems and is more cost effective than its counterparts.
Prosthetics and Orthotics International | 2012
Arezoo Eshraghi; Noor Azuan Abu Osman; Hossein Gholizadeh; Mohammad Taghi Karimi; Sadeeq Ali
Background: One of the main indicators of the suspension system efficiency in lower limb prostheses is vertical displacement or pistoning within the socket. Decreasing pistoning and introducing an effective system for evaluating pistoning could contribute to the amputees’ rehabilitation process. Objectives: The main objective of this study was to review existing research studies that examine the occurrence of pistoning in lower limb prosthesis with different techniques in static (standing) and dynamic (walking and jumping) positions. Study Design: Literature review. Methods: Keywords related to slippage, suspension, pistoning and vertical movement in lower limb prosthetics were used to search the literature available in PubMed, ScienceDirect, Web of Science and Google Scholar databases. Sixteen articles were selected for further analysis according to the selection criteria. Results: The following methods have been used to measure the occurrence of pistoning in prosthetic limbs: radiological methods, photographic technique, motion analysis system, sensor and spiral computerized tomography (CT). Pistoning was measured both in standing and walking. Conclusions: The results of this review reveal that further research is needed to develop and evaluate easy, accurate and safe methods of measuring pistoning. Future studies should provide a gold standard for the acceptable range of pistoning in a prosthetic socket. Clinical relevance This literature review contributes to a further understanding of lower limb prosthetic biomechanics by highlighting the strengths and weaknesses of the techniques that are currently available for evaluating the occurrence of pistoning in a prosthetic socket. It provides a useful overview of the current methods of measuring residual limb movements relative to the socket and liner, and will be of use for both practitioners and researchers in prosthetics and orthotics fields.
Clinical Biomechanics | 2012
Sadeeq Ali; Noor Azuan Abu Osman; Niyousha Mortaza; Arezoo Eshraghi; Hossein Gholizadeh; Wan Abu Bakar Wan Abas
BACKGROUND The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputees satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction. METHODS Nine unilateral transtibial amputees participated in the study. Two prostheses were fabricated for each amputee, one with the Seal-In liner and one with the Dermo liner. Interface pressure was measured at the anterior, posterior, medial and lateral regions during walking on the level ground. Each subject filled in a Prosthetic Evaluation Questionnaire (PEQ) regarding the satisfaction with the two liners. Findings The mean peak pressures with the Seal-In liner was 34.0% higher at the anterior, 24.0% higher at the posterior and 7.0% higher at the medial regions of the socket (P=0.008, P=0.046, P=0.025) than it was with the Dermo Liner. There were no significant differences in the mean peak pressures between the two liners at the lateral regions. In addition, significant difference was found between the two liners both for satisfaction and problems (P<0.05). Interpretation There was less interface pressure between the socket and the residual limb with the Dermo liner. The results indicated that the Dermo liner provides more comfort in the socket than the Seal-In liner.
Clinical Biomechanics | 2013
Arezoo Eshraghi; Noor Azuan Abu Osman; Hossein Gholizadeh; Sadeeq Ali; Stefan Saevarsson; Wan Abu Bakar Wan Abas
BACKGROUND Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS Twelve unilateral transtibial amputees participated in the study. The subjects walked on a level walkway at a self-selected speed. The resultant peak pressure with the three different suspension systems was recorded using F-socket transducers. FINDINGS There were significant statistical differences between the three studied suspension systems. Pair-wise analyses revealed that the mean peak pressure (kPa) was lower with the magnetic system than it was with the pin/lock system over the anterior and posterior aspects during one gait cycle (89.89 vs. 79.26 and 47.22 vs. 26.01, respectively). Overall, the average peak pressure values were higher with the Seal-In system than they were with the new magnetic lock and pin/lock system. INTERPRETATION The new magnetic system might reduce the pressure within the prosthetic socket in comparison to the pin/lock and Seal-In system during one gait cycle. This is particularly important during the swing phase of gait and may reduce the pain and discomfort at the distal residual limb in comparison to the pin/lock system.
Biomedical Engineering Online | 2013
Arezoo Eshraghi; Noor Azuan Abu Osman; Hossein Gholizadeh; Sadeeq Ali; Babak Shadgan
Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett’s initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case–control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.
Archives of Physical Medicine and Rehabilitation | 2013
Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Elham Sadat Yahyavi
OBJECTIVE To compare a seal-in liner with the common suction socket with regards to patient satisfaction and problems experienced with the prosthesis. DESIGN Retrospective survey. SETTING A medical and engineering research center and a department of biomechanical engineering. PARTICIPANTS Men (N=90) with traumatic transfemoral amputation who used both suspension systems participated in the study. INTERVENTION Two prosthetic suspension systems: a seal-in liner and common suction socket. MAIN OUTCOME MEASURES Two questionnaires were completed by each subject to evaluate their satisfaction and problems experienced with the 2 suspension systems. Satisfaction and problems with the prosthetic suspension systems were analyzed in terms of fitting, donning and doffing, sitting, walking, stair negotiation, appearance, sweating, wounds, pain, irritation, pistoning, edema, smell, sound, and durability. RESULTS The study revealed that the respondents were more satisfied with a seal-in liner with regards to fitting, sitting, and donning and doffing. Overall satisfaction increased with the use of a seal-in liner compared with the suction socket (P<.05). However, satisfaction with the prosthesis showed no significant differences in terms of walking (flat and uneven surfaces), appearance, and stair negotiation. Furthermore, problems experienced differed significantly between the 2 suspension systems (P<.05). Sweating, wounds, pain, irritation, pistoning, edema, smell, and sound were less problematic with the use of a seal-in liner, whereas durability was significantly better with the suction socket. CONCLUSIONS The results of the survey suggest that satisfaction and problems with prosthetic suspension in persons with transfemoral amputation can be improved with a seal-in liner compared with the suction socket, provided that the durability of the liner is enhanced.
The Scientific World Journal | 2014
Gh. Pirouzi; N. A. Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Hossein Gholizadeh; Wan Abu Bakar Wan Abas
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
Clinical Biomechanics | 2013
Sadeeq Ali; Noor Azuan Abu Osman; Arezoo Eshraghi; Hossein Gholizadeh; Nasrul Anwar bin Abd razak; Wan Abu Bakar Wan Abas
BACKGROUND Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems during stair ascent and descent, and to determine their satisfaction effects on users. METHODS Ten amputees with unilateral transtibial amputation participated in the study. Interface pressure was recorded with F-socket transducer (9811E) during stair ascent and descent at self-selected speed. Each participant filled in a questionnaire about satisfaction and problems encountered with the use of the two interface systems. FINDINGS The resultant mean peak pressure (kPa) was significantly lower for the Dermo interface system compared to that of the Seal-In X5 interface system at the anterior, posterior and medial regions during stair ascent (63.14 vs. 80.14, 63.14 vs. 90.44, 49.21 vs. 66.04, respectively) and descent (67.11 vs. 80.41, 64.12 vs. 88.24, 47.33 vs. 65.11, respectively). Significant statistical difference existed between the two interface systems in terms of satisfaction and problems encountered (P<0.05). INTERPRETATION The Dermo interface system caused less pressure within the prosthetic socket compared to the Seal-In X5 interface system during stair negotiation. The qualitative survey also showed that the prosthesis users experienced fewer problems and increased satisfaction with the Dermo interface system.
Archive | 2011
Hossein Gholizadeh; N. A. Abu Osman; Á. G. Lúðvíksdóttir; Mojtaba Kamyab; Arezoo Eshraghi; Sadeeq Ali; Wan Abu Bakar Wan Abas
The quality of suspension in lower limb prosthetics has significant role in amputee’s satisfaction. Good suspension lessens the pistoning movement of the residual limb inside the prosthetic socket. A number of methods are used for measuring pistoning; however most of them are difficult to be performed inside the prosthetic clinic and by every prosthetist. The purpose of this study was to introduce a new simple method for measuring pistoning in Transtibial prosthesis in static position. This method was developed in-house at Ossur for the first time. In this study we used this technique to measure pistoning between socket and liner in three subjects. The result showed that this method can be an alternative method for measuring pistoning. Moreover, that makes it simple for prosthetists to test pistoning in the clinic and is a safe method for the subject.
PLOS ONE | 2014
Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali
Background The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees’ gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees’ gait performance. Methodology/Principal Findings Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ) regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05). Evaluation of kinetic data and the subjects’ feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. Conclusion It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis. Trial Registration irct.ir IRCT2014012816395N1