Nooranida Arifin
University of Malaya
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Nooranida Arifin.
Biomedical Engineering Online | 2014
Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Nooranida Arifin; Wan Abu Bakar Wan Abas
BackgroundGood prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems).MethodsAll the suspension systems were tested (tensile testing machine) in terms of the degree of the shear strength and the patient’s comfort. Nine transtibial amputees participated in this study. The patients were asked to use four different suspension systems. Afterwards, each participant completed a questionnaire for each system to evaluate their comfort. Furthermore, the systems were compared in terms of the cost.ResultsThe maximum tensile load that the new system could bear was 490 N (SD, 5.5) before the system failed. Pin/lock, magnetic and suction suspension systems could tolerate loads of580 N (SD, 8.5), 350.9 (SD, 7) and 310 N (SD, 8.4), respectively. Our subjects were satisfied with the new hook and loop system, particularly in terms of easy donning and doffing. Furthermore, the new system is considerably cheaper (35 times) than the current locking systems in the market.ConclusionsThe new suspension system could successfully retain the prosthesis on the residual limb as a good alternative for lower limb amputees. In addition, the new system addresses some problems of the existing systems and is more cost effective than its counterparts.
Journal of Applied Biomechanics | 2014
Nooranida Arifin; Noor Azuan Abu Osman; Wan Abu Bakar Wan Abas
The measurements of postural balance often involve measurement error, which affects the analysis and interpretation of the outcomes. In most of the existing clinical rehabilitation research, the ability to produce reliable measures is a prerequisite for an accurate assessment of an intervention after a period of time. Although clinical balance assessment has been performed in previous study, none has determined the intrarater test-retest reliability of static and dynamic stability indexes during dominant single stance. In this study, one rater examined 20 healthy university students (female=12, male=8) in two sessions separated by 7 day intervals. Three stability indexes--the overall stability index (OSI), anterior/posterior stability index (APSI), and medial/ lateral stability index (MLSI) in static and dynamic conditions--were measured during single dominant stance. Intraclass correlation coefficient (ICC), standard error measurement (SEM) and 95% confidence interval (95% CI) were calculated. Test-retest ICCs for OSI, APSI, and MLSI were 0.85, 0.78, and 0.84 during static condition and were 0.77, 0.77, and 0.65 during dynamic condition, respectively. We concluded that the postural stability assessment using Biodex stability system demonstrates good-to-excellent test-retest reliability over a 1 week time interval.
Biomedical Engineering Online | 2014
Nooranida Arifin; Noor Azuan Abu Osman; Sadeeq Ali; Wan Abu Bakar Wan Abas
BackgroundAchieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet.MethodsTen male below-knee amputees were instructed to stand quietly on the Biodex® balance platform while wearing solid ankle cushion heel (SACH), single axis (SA) and energy storage and release (ESAR) prosthetic foot under different visual input conditions (eyes-opened and eyes-closed). The overall stability index (OSI), anterior- posterior stability index (APSI), and medial-lateral stability index (MLSI) were computed. Perceived balance assessment of each foot was evaluated using Activities-specific Balance Confidence (ABC) score.ResultsThe findings highlights that SACH showed lowest overall stability index (indicating less body sway) during eyes-opened (OSI: SACH = 1.09, SA = 1.58, ESAR = 1.59) and SA showed lowest overall stability index during eyes-closed (OSI: SACH = 2.52, SA = 2.30, ESAR = 2.76) condition. However, overall stability indexes between foot types did not differ significantly during eyes-opened or eyes-closed (p = 0.651). There was a trend of instability which occurred more in medial-lateral compared to anterior-posterior direction for all foot types, with significant result in ESAR foot(eyes-opened: MLSI = 1.59, APSI = 0.65, p = 0.034; eyes-closed: MLSI = 2.76, APSI = 1.80, p = 0.017, respectively). When comparing between visual conditions, stability score was significantly higher during eyes-closed compared to eyes-opened situations for SACH and ESAR foot (eyes-closed vs opened; SACH OSI: 3.43 vs 1.71, p = 0.018 and MLSI: 3.43 vs 1.71, p = 0.018; ESAR OSI: 3.58 vs 1.86, p = 0.043 and APSI: 1.80 vs 0.65, p = 0.027).ConclusionsThe results of this study suggested postural steadiness in below-knee amputees was not affected by the types of prosthetic foot during quiet upright standing, but was significantly affected when visual cues was absent.
The Scientific World Journal | 2014
Nooranida Arifin; Noor Azuan Abu Osman; Sadeeq Ali; Hossein Gholizadeh; Wan Abu Bakar Wan Abas
Purpose. This study aimed to evaluate the effects of prosthetic foot types on the postural stability among transtibial amputees when standing on different support surfaces. Materials and Methods. The postural stability of 10 transtibial amputees wearing solid ankle cushion heel (SACH) foot, single-axis (SA) foot, and energy-saving and return (ESAR) foot was assessed. Results were compared with able-bodied participants. Anterior-posterior stability index (APSI), mediolateral stability index (MLSI), and overall stability index (OSI) were measured by computed posturography in an upright stance on firm, foam, and unstable support surfaces. Results. The mean OSI score of SACH foot was significantly lower than that of an ESAR foot when the participants were standing on a compliant surface. When compared to able-bodied group, MLSI score was significantly higher for each of the prosthetic foot groups while OSI score was significantly higher for ESAR foot only in foam condition. Conclusions. Differences between prosthetic foot types and groups (amputees versus able-bodied) can only be distinguished when individuals were standing on a compliant surface. Amputees exhibited an increased postural instability in the mediolateral direction than able-bodied individuals. Hence, the restoration of stability in the frontal plane and the enhancement of proprioception at the residual limb should be the basis of rehabilitation programs.
ieee region 10 conference | 2006
Fatimah Ibrahim; J. H. Chae; Nooranida Arifin; N. M. Zarmani; Jongman Cho
This study presents the analysis of surface electromyography (sEMG) of facial muscles in different age categories. The analysis was evaluated when the subjects performed the gripping oral exercise device in a static contraction. The sEMG measurements were taken at four positions; Orbicularis Oris Superiors Left (OOSL) and Right (OOSR), Orbicularis Oris Inferiors Left (OOIL) and Right (OOIR) using TeleMyo2400T. There are only 4 female subjects participated in the study which is divided into 2 Groups: Groups 1 and 2 with mean age of 47.5 and 23 years old, respectively. The findings indicate that the mean and median frequencies of sEMG activity recorded from both left and right of OOS and OOI muscles showed decreasing trend from the beginning until the end of the static contraction sessions. The power spectral density of sEMG signal on those muscles for both groups is in the range of 19 to 45 Hz
The Scientific World Journal | 2014
Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar bin Abd razak; Wan Abu Bakar Wan Abas
Purpose. This study aimed to compare the effect of satisfaction and perceived problems between Pelite, Dermo with shuttle lock, and Seal-In X5 liners on the transtibial amputees. Material and Methods. A total of thirty transtibial amputees (17 male, 13 female) volunteered to take part in this research. Two prostheses were fabricated for each participant. Prosthetic Evaluation Questionnaire (PEQ) was filled in by the participants with the three liners. Results. The statistics highlight that Dermo liner showed significantly higher score (P = 0.05) in walking, walking on uneven surfaces, stairs walking, fitting, donning/doffing, sitting, suspension, and overall satisfaction with Dermo liner compared with Seal-In X5 and Pelite liners. Overall satisfaction was 34% higher with Dermo liner than Seal-In X5 liner and 28% higher than Pelite liner. Participants reported less problems with Dermo liner and significant differences (P < 0.05) were recorded between the three liners in sweating, skin irritation, frustration, and pain compared with Seal-In X5 and Pelite liners. Conclusion. Participants experienced high level of satisfaction and practiced fewer problems with Dermo liner. These results showed that there is good indication to believe that Dermo liner might be a good choice for transtibial users and might help the clinicians and prosthetic practitioners in selection criteria of prosthetic liners.
The Malaysian journal of medical sciences | 2017
Nooranida Arifin; Hasif Rafidee Hasbollah; Muhammad Hafiz Hanafi; Al Hafiz Ibrahim; Wan Afezah Wan Abdul Rahman; Roslizawati Che Aziz
The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved.
Journal of Biomedical Optics | 2017
Ebrahim A. Al-Fakih; Nooranida Arifin; Gholamhossein Pirouzi; Faisal Rafiq Mahamd Adikan; Hanie Nadia Shasmin; Noor Azuan Abu Osman
This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputees simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputees satisfaction.
Prosthetics and Orthotics International | 2016
Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nooranida Arifin; Tze Yang Chung
Background: This article describes a total surface bearing prosthetic socket for a patient (25-year-old female) with a bulbous stump. Case Description and Methods: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure. Findings and Outcomes: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier. Conclusion: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait. Clinical relevance Proper socket design and suspension system based on the amputees’ need can facilitate rehabilitation process and lead to the amputee’s satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2015
Nooranida Arifin; Noor Azuan Abu Osman; Sadeeq Ali; Hossein Gholizadeh; Wan Abu Bakar Wan Abas
In recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex® Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior–posterior (APSI) and medial–lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°–5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%–94%) was significantly longer than the amputated limb (20%–6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomes produced by the BSS.