Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sandrine Pascal is active.

Publication


Featured researches published by Sandrine Pascal.


Journal of Astronomical Telescopes, Instruments, and Systems | 2015

Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph

Hajime Sugai; Naoyuki Tamura; Hiroshi Karoji; Atsushi Shimono; Naruhisa Takato; Masahiko Kimura; Youichi Ohyama; Akitoshi Ueda; Hrand Aghazarian; Marcio Vital de Arruda; Robert H. Barkhouser; C. L. Bennett; Steve Bickerton; Alexandre Bozier; David F. Braun; Khanh Bui; Christopher M. Capocasale; Michael A. Carr; Bruno Castilho; Yin-Chang Chang; Hsin-Yo Chen; Richard C. Y. Chou; Olivia R. Dawson; Richard G. Dekany; Eric M. Ek; Richard S. Ellis; Robin J. English; Didier Ferrand; Décio Ferreira; Charles D. Fisher

Abstract. The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38  μm to 1.26  μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71  μm to 0.89  μm will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.


Proceedings of SPIE | 2016

The E-ELT first light spectrograph HARMONI: capabilities and modes

Niranjan Thatte; Fraser Clarke; Ian Bryson; Hermine Shnetler; Matthias Tecza; Thierry Fusco; Roland Bacon; Johan Richard; Evencio Mediavilla; Benoit Neichel; S. Arribas; B. García-Lorenzo; C. J. Evans; Alban Remillieux; Kacem El Madi; José Miguel Herreros; Dave Melotte; K. O'Brien; Ian Tosh; J. Vernet; P. L. Hammersley; Derek Ives; Gert Finger; Ryan C. W. Houghton; D. Rigopoulou; J. Lynn; Jamie R. Allen; Simon Zieleniewski; Sarah Kendrew; Vanessa Ferraro-Wood

HARMONI is the E-ELT’s first light visible and near-infrared integral field spectrograph. It will provide four different spatial scales, ranging from coarse spaxels of 60 × 30 mas best suited for seeing limited observations, to 4 mas spaxels that Nyquist sample the diffraction limited point spread function of the E-ELT at near-infrared wavelengths. Each spaxel scale may be combined with eleven spectral settings, that provide a range of spectral resolving powers (R ~3500, 7500 and 20000) and instantaneous wavelength coverage spanning the 0.5 – 2.4 μm wavelength range of the instrument. In autumn 2015, the HARMONI project started the Preliminary Design Phase, following signature of the contract to design, build, test and commission the instrument, signed between the European Southern Observatory and the UK Science and Technology Facilities Council. Crucially, the contract also includes the preliminary design of the HARMONI Laser Tomographic Adaptive Optics system. The instrument’s technical specifications were finalized in the period leading up to contract signature. In this paper, we report on the first activity carried out during preliminary design, defining the baseline architecture for the system, and the trade-off studies leading up to the choice of baseline.


Proceedings of SPIE | 2016

Prime Focus Spectrograph (PFS) for the Subaru telescope: overview, recent progress, and future perspectives

Naoyuki Tamura; Naruhisa Takato; Atsushi Shimono; Yuki Moritani; Kiyoto Yabe; Yuki Ishizuka; Akitoshi Ueda; Yukiko Kamata; Hrand Aghazarian; S. Arnouts; Gabriel Barban; Robert H. Barkhouser; Renato C. Borges; David F. Braun; Michael A. Carr; Pierre-Yves Chabaud; Yin-Chang Chang; Hsin-Yo Chen; Masashi Chiba; Richard C. Y. Chou; You-Hua Chu; Judith G. Cohen; Rodrigo P. de Almeida; Antonio Cesar de Oliveira; Ligia Souza de Oliveira; Richard G. Dekany; Kjetil Dohlen; Jesulino Bispo dos Santos; Leandro H. dos Santos; Richard S. Ellis

PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6 - 2.7Å. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.


Proceedings of SPIE | 2014

The near infrared camera for the Subaru Prime Focus Spectrograph

Stephen A. Smee; James E. Gunn; Mirek Golebiowski; Robert H. Barkhouser; S. Vives; Sandrine Pascal; Michael A. Carr; Stephen C. Hope; Craig Loomis; Murdock Hart; Hajime Sugai; Naoyuki Tamura; Atsushi Shimono

We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 μm. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 μm. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 µm pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 μm cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 μm. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector. The camera optics and detector are packaged in a cryostat and cooled by two Stirling cycle cryocoolers. The first corrector element serves as the vacuum window, while the second element is thermally isolated and floats cold. An assembly constructed primarily of silicon carbide is used to mount the Mangin mirror, and to support the detector and field flattener. Thermal isolation between the cold optics and warm ambient surroundings is provided by G10 supports, multi-layer insulation, and the vacuum space within the cryostat. In this paper we describe the detailed design of the PFS NIR camera and discuss its predicted optical, thermal, and mechanical performance.


Proceedings of SPIE | 2014

Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

Hajime Sugai; Naoyuki Tamura; Hiroshi Karoji; Atsushi Shimono; Naruhisa Takato; Masahiko Kimura; Youichi Ohyama; Akitoshi Ueda; Hrand Aghazarian; Marcio Vital de Arruda; Robert H. Barkhouser; C. L. Bennett; Steve Bickerton; Alexandre Bozier; David F. Braun; Khanh Bui; Christopher M. Capocasale; Michael A. Carr; Bruno Castilho; Yin-Chang Chang; Hsin-Yo Chen; Richard C. Y. Chou; Olivia R. Dawson; Richard G. Dekany; Eric M. Ek; Richard S. Ellis; Robin J. English; Didier Ferrand; Décio Ferreira; Charles D. Fisher

The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 μm to 1.26 μm, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 μm to 0.89 μm also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts (SuMIRe) project, while Hyper Suprime-Cam (HSC) works on the imaging part. HSC’s excellent image qualities have proven the high quality of the Wide Field Corrector (WFC), which PFS shares with HSC. The PFS collaboration has succeeded in the project Preliminary Design Review and is now in a phase of subsystem Critical Design Reviews and construction. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated microlens is glued to each fiber tip. The microlenses are molded glass, providing uniform lens dimensions and a variety of refractive-index selection. After successful production of mechanical and optical samples, mass production is now complete. Following careful investigations including Focal Ratio Degradation (FRD) measurements, a higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. After evaluating the statistics of positioning accuracies, collision avoidance software, and interferences (if any) within/between electronics boards, mass production will commence. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. All optical glass blanks are now being polished. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms. The active damping system against cooler vibration has been proven to work as predicted, and spectrographs have been designed to avoid small possible residual resonances.


Proceedings of SPIE | 2016

Final design of the grism cryogenic mount for the Euclid-NISP mission

Christelle Rossin; A. Costille; A. Caillat; Sandrine Pascal; Patrice Sanchez; Benjamin Foulon; S. Vives; Lorenzo Zavattini; Andrea Moroni; Paolo Radaelli

The grism mount design for the Euclid-NISP mission was studied to maintain optical performances and alignment at cryogenic temperature, and to survive to launch vibrations. An Invar mount with strong weight-relief bonded to the Silica grism through tangential blades has been designed. In spring 2015 we proceeded to thermal cycling and vibration tests to successfully qualify the Grism Engineering Model in the Euclid space environment. Thanks to detailed Finite Element analyses, we correlated simulations and tests. Now that phase C began, we are manufacturing the Engineering and Qualification Model and the four Flight Models. Thus, random coupled analyses of the grisms on the complete wheel assembly and impact of interface preloads on the grism behavior have also been studied.


Proceedings of SPIE | 2014

Bulk silica transmission grating made by reactive ion etching for NIR space instruments

A. Caillat; Sandrine Pascal; Stéphane Tisserand; Kjetil Dohlen; R. Grange; Vincent Sauget; Sophie Gautier

A GRISM, made of a grating on a prism, allow combining image and spectroscopy of the same field of view with the same optical system and detector, thus simplify instrument concept. New GRISM designs impose technical specifications difficult to reach with classical grating manufacturing processes: large useful aperture (>100mm), low groove frequency (<30g/mm), small blaze angle (<3°) and, last but not least, line curvature allowing wavefront corrections. In addition, gratings are commonly made of resin which may not be suitable to withstand the extreme space environment. Therefore, in the frame of a R&D project financed by the CNES, SILIOS Technologies developed a new resin-free grating manufacturing process and realized a first 80mm diameter prototype optically tested at LAM. We present detailed specifications of this resin-free grating, the manufacturing process, optical setups and models for optical performance verification and very encouraging results obtained on the first 80mm diameter grating prototype: >80% transmitted efficiency, <30nm RMS wavefront error, groove shape and roughness very close to theory and uniform over the useful aperture.


arXiv: Instrumentation and Methods for Astrophysics | 2018

Opto-mechanical designs for the HARMONI adaptive optics systems

Kjetil Dohlen; Kacem El Hadi; Sandrine Pascal; Pascal Vola; M. Llored; Tim Morris; Ariadna Calcines-Rosario; A. Costille; Benoit Neichel; Jean-François Sauvage; Thierry Fusco; Niranjan Thatte; Fraser Clarke; Ian Bryson; Hermine Schnetler; Javier Piqueras Lopez; Marc Dubbeldam

HARMONI is a visible and near-infrared integral field spectrograph equipped with two complementary adaptive optics systems, fully integrated within the instrument. A Single Conjugate AO (SCAO) system offers high performance for a limited sky coverage and a Laser Tomographic AO (LTAO) system provides AO correction with a very high sky-coverage. While the deformable mirror performing real-time correction of the atmospheric disturbances is located within the telescope itself, the instrument contains a suite of state-of-the-art and innovative wavefront sensor systems. Laser guide star sensors (LGSS) are located at the entrance of the instrument and fed by a dichroic beam splitter, while the various natural guide star sensors for LTAO and SCAO are located close to the science focal plane. We present opto-mechanical architecture and design at PDR level for these wavefront sensor systems.


Ground-based and Airborne Instrumentation for Astronomy VII | 2018

SUBARU prime focus spectrograph integration and performance at LAM

Fabrice Madec; Kjetil Dohlen; Arnaud Le Fur; Mohamed Belhadi; Sandrine Pascal; David Le Mignant; Rudy Barette; M. Jaquet; P. Blanchard; Stephen A. Smee; James Edward Gunn; Ligia Souza de Oliveira; Décio Ferreira; Naoyuki Tamura; Craig Loomis; Mirek Golebiowski; Murdock Hart; Atsushi Shimono; Philippe Balard; Florence roman; Joël Le Merrer; M. Llored; Lapère Vincent; Jean-François Gabriel; Anny Oliveira

The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project for Subaru telescope includes four identical spectrograph modules fed by 600 fibers each. This paper presents the integration, alignment and test procedures for the first spectrograph module composed by an optical entrance unit that creates a collimated beam and distributes the light to three channels, two visible and one near infrared. In particular, we present the performance of the single Red channel module. Firstly, we report on the measured optical performance: optical quality and ghost analysis. We also report on the thermal performance of the visible camera cryostat. Finally, we describe the software used to control and monitor the instrument.


International Conference on Space Optics — ICSO 2016 | 2017

EUCLID/NISP GRISM qualification model AIT/AIV campaign: optical, mechanical, thermal and vibration tests

A. Caillat; A. Costille; Sandrine Pascal; C. Rossin; S. Vives; B. Foulon; P. Sanchez; Nikos Karafolas; Bruno Cugny; Zoran Sodnik

Dark matter and dark energy mysteries will be explored by the Euclid ESA M-class space mission which will be launched in 2020. Millions of galaxies will be surveyed through visible imagery and NIR imagery and spectroscopy in order to map in three dimensions the Universe at different evolution stages over the past 10 billion years. The massive NIR spectroscopic survey will be done efficiently by the NISP instrument thanks to the use of grisms (for “Grating pRISMs”) developed under the responsibility of the LAM. In this paper, we present the verification philosophy applied to test and validate each grism before the delivery to the project. The test sequence covers a large set of verifications: optical tests to validate efficiency and WFE of the component, mechanical tests to validate the robustness to vibration, thermal tests to validate its behavior in cryogenic environment and a complete metrology of the assembled component. We show the test results obtained on the first grism Engineering and Qualification Model (EQM) which will be delivered to the NISP project in fall 2016.

Collaboration


Dive into the Sandrine Pascal's collaboration.

Top Co-Authors

Avatar

A. Caillat

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar

Kjetil Dohlen

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar

S. Vives

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar

A. Costille

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Benoit Neichel

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge