Featured researches published by Sara Hartnell.


The New England Journal of Medicine | 2015

Home Use of an Artificial Beta Cell in Type 1 Diabetes

Hood Thabit; Martin Tauschmann; Janet Macdonald Allen; Lalantha Leelarathna; Sara Hartnell; Malgorzata E Wilinska; Carlo L. Acerini; Sibylle Dellweg; Carsten Benesch; Lutz Heinemann; Julia K. Mader; Manuel Holzer; Harald Kojzar; Jane Exall; James Yong; Jennifer Pichierri; Katharine Barnard; Craig Kollman; Peiyao Cheng; Peter C. Hindmarsh; Fiona Campbell; Sabine Arnolds; Thomas R. Pieber; Mark L. Evans; David B. Dunger; Roman Hovorka

BACKGROUND The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established. METHODS In two multicenter, crossover, randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents. RESULTS Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval [CI], 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, -11 mg per deciliter; 95% CI, -17 to -6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, -0.3%; 95% CI, -0.5 to -0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, -29 mg per deciliter; 95% CI, -39 to -20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic episodes occurred during the closed-loop phase when the closed-loop system was not in use. CONCLUSIONS Among patients with type 1 diabetes, 12-week use of a closed-loop system, as compared with sensor-augmented pump therapy, improved glucose control, reduced hypoglycemia, and, in adults, resulted in a lower glycated hemoglobin level. (Funded by the JDRF and others; AP@home04 and APCam08 ClinicalTrials.gov numbers, NCT01961622 and NCT01778348.).


Diabetes Care | 2014

Day and Night Home Closed-Loop Insulin Delivery in Adults With Type 1 Diabetes: Three-Center Randomized Crossover Study

Lalantha Leelarathna; Sibylle Dellweg; Julia K. Mader; Janet Macdonald Allen; Carsten Benesch; Werner Doll; Martin Ellmerer; Sara Hartnell; Lutz Heinemann; Harald Kojzar; Lucy Michalewski; Marianna Nodale; Hood Thabit; Malgorzata E Wilinska; Thomas R. Pieber; Sabine Arnolds; Mark L. Evans; Roman Hovorka

OBJECTIVE To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions. RESEARCH DESIGN AND METHODS Seventeen adults with type 1 diabetes on insulin pump therapy (means ± SD age 34 ± 9 years, HbA1c 7.6 ± 0.8%, and duration of diabetes 19 ± 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase. RESULTS During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61–79] vs. 62% [53–70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013). CONCLUSIONS Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.


The New England Journal of Medicine | 2016

Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes

Zoe A. Stewart; Malgorzata E Wilinska; Sara Hartnell; Rosemary C. Temple; Gerry Rayman; Katharine P. Stanley; David Simmons; Graham R. Law; Eleanor M. Scott; Roman Hovorka; Helen R. Murphy

BACKGROUND In patients with type 1 diabetes who are not pregnant, closed-loop (automated) insulin delivery can provide better glycemic control than sensor-augmented pump therapy, but data are lacking on the efficacy, safety, and feasibility of closed-loop therapy during pregnancy. METHODS We performed an open-label, randomized, crossover study comparing overnight closed-loop therapy with sensor-augmented pump therapy, followed by a continuation phase in which the closed-loop system was used day and night. Sixteen pregnant women with type 1 diabetes completed 4 weeks of closed-loop pump therapy (intervention) and sensor-augmented pump therapy (control) in random order. During the continuation phase, 14 of the participants used the closed-loop system day and night until delivery. The primary outcome was the percentage of time that overnight glucose levels were within the target range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]). RESULTS The percentage of time that overnight glucose levels were in the target range was higher during closed-loop therapy than during control therapy (74.7% vs. 59.5%; absolute difference, 15.2 percentage points; 95% confidence interval, 6.1 to 24.2; P=0.002). The overnight mean glucose level was lower during closed-loop therapy than during control therapy (119 vs. 133 mg per deciliter [6.6 vs. 7.4 mmol per liter], P=0.009). There were no significant differences between closed-loop and control therapy in the percentage of time in which glucose levels were below the target range (1.3% and 1.9%, respectively; P=0.28), in insulin doses, or in adverse-event rates. During the continuation phase (up to 14.6 additional weeks, including antenatal hospitalizations, labor, and delivery), glucose levels were in the target range 68.7% of the time; the mean glucose level was 126 mg per deciliter (7.0 mmol per liter). No episodes of severe hypoglycemia requiring third-party assistance occurred during either phase. CONCLUSIONS Overnight closed-loop therapy resulted in better glucose control than sensor-augmented pump therapy in pregnant women with type 1 diabetes. Women receiving day-and-night closed-loop therapy maintained glycemic control during a high proportion of the time in a period that encompassed antenatal hospital admission, labor, and delivery. (Funded by the National Institute for Health Research and others; Current Controlled Trials number, ISRCTN71510001.).


The Lancet Diabetes & Endocrinology | 2017

Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study

Lia Bally; Hood Thabit; Harald Kojzar; Julia K. Mader; Jehona Qerimi-Hyseni; Sara Hartnell; Martin Tauschmann; Janet M. Allen; Malgorzata E Wilinska; Thomas R. Pieber; Mark Lewis Evans; Roman Hovorka

Summary Background Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA1c below 7·5% (58 mmol/mol). Methods In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA1c below 7·5% from Addenbrookes Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2–4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2–4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9–10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT02727231, and is completed. Findings Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. One participant withdrew during the first closed-loop period because of dissatisfaction with study devices and glucose control. The proportion of time when sensor glucose concentration was in target range was 10·5 percentage points higher (95% CI 7·6–13·4; p<0·0001) during closed-loop delivery compared with usual pump therapy (65·6% [SD 8·1] when participants used usual pump therapy vs 76·2% [6·4] when they used closed-loop). Compared with usual pump therapy, closed-loop delivery also reduced the proportion of time spent in hypoglycaemia: the proportion of time with glucose concentration below 3·5 mmol/L was reduced by 65% (53–74, p<0·0001) and below 2·8 mmol/L by 76% (59–86, p<0·0001). No episodes of serious hypoglycaemia or other serious adverse events occurred. Interpretation Use of day-and-night hybrid closed-loop insulin delivery under unsupervised, free-living conditions for 4 weeks in adults with type 1 diabetes and HbA1c below 7·5% is safe and well tolerated, improves glucose control, and reduces hypoglycaemia burden. Larger and longer studies are warranted. Funding Swiss National Science Foundation (P1BEP3_165297), JDRF, UK National Institute for Health Research Cambridge Biomedical Research Centre, and Wellcome Strategic Award (100574/Z/12/Z).


Diabetes Care | 2016

Variability of Insulin Requirements Over 12 Weeks of Closed-Loop Insulin Delivery in Adults With Type 1 Diabetes.

Yue Ruan; Hood Thabit; Lalantha Leelarathna; Sara Hartnell; Malgorzata E. Willinska; Sibylle Dellweg; Carsten Benesch; Julia K. Mader; Manuel Holzer; Harald Kojzar; Mark L. Evans; Thomas R. Pieber; Sabine Arnolds; Roman Hovorka

OBJECTIVE To quantify variability of insulin requirements during closed-loop insulin delivery. RESEARCH DESIGN AND METHODS We retrospectively analyzed overnight, daytime, and total daily insulin amounts delivered during a multicenter closed-loop trial involving 32 adults with type 1 diabetes. Participants applied hybrid day-and-night closed-loop insulin delivery under free-living home conditions over 12 weeks. The coefficient of variation was adopted to measure variability of insulin requirements in individual subjects. RESULTS Data were analyzed from 1,918 nights, 1,883 daytime periods and 1,564 total days characterized by closed-loop use over 85% of time. Variability of overnight insulin requirements (mean [SD] coefficient of variation 31% [4]) was nearly twice as high as variability of total daily requirements (17% [3], P < 0.001) and was also higher than variability of daytime insulin requirements (22% [4], P < 0.001). CONCLUSIONS Overnight insulin requirements were significantly more variable than daytime and total daily amounts. This may explain why some people with type 1 diabetes report frustrating variability in morning glycemia.


The Lancet Diabetes & Endocrinology | 2017

Closed-loop insulin delivery in inpatients with type 2 diabetes: a randomised, parallel-group trial

Hood Thabit; Sara Hartnell; Janet M. Allen; Andrea Lake; Malgorzata E Wilinska; Yue Ruan; Mark L. Evans; Anthony P. Coll; Roman Hovorka

BACKGROUND We assessed whether fully closed-loop insulin delivery (the so-called artificial pancreas) is safe and effective compared with standard subcutaneous insulin therapy in patients with type 2 diabetes in the general ward. METHODS For this single-centre, open-label, parallel-group, randomised controlled trial, we enrolled patients aged 18 years or older with type 2 diabetes who were receiving insulin therapy. Patients were recruited from general wards at Addenbrookes Hospital, Cambridge, UK. Participants were randomly assigned (1:1) by a computer-generated minimisation method to receive closed-loop insulin delivery (using a model-predictive control algorithm to direct subcutaneous delivery of rapid-acting insulin analogue without meal-time insulin boluses) or conventional subcutaneous insulin delivery according to local clinical guidelines. The primary outcome was time spent in the target glucose concentration range of 5·6-10·0 mmol/L during the 72 h study period. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01774565. FINDINGS Between Feb 20, 2015, and March 24, 2016, we enrolled 40 participants, of whom 20 were randomly assigned to the closed-loop intervention group and 20 to the control group. The proportion of time spent in the target glucose range was 59·8% (SD 18·7) in the closed-loop group and 38·1% (16·7) in the control group (difference 21·8% [95% CI 10·4-33·1]; p=0·0004). No episodes of severe hypoglycaemia or hyperglycaemia with ketonaemia occurred in either group. One adverse event unrelated to study devices occurred during the study (gastrointestinal bleed). INTERPRETATION Closed-loop insulin delivery without meal-time boluses is effective and safe in insulin-treated adults with type 2 diabetes in the general ward. FUNDING Diabetes UK; European Foundation for the Study of Diabetes; JDRF; National Institute for Health Research Cambridge Biomedical Research Centre; Wellcome Trust.


Journal of diabetes science and technology | 2017

Closing the Loop in Adults, Children and Adolescents With Suboptimally Controlled Type 1 Diabetes Under Free Living Conditions: A Psychosocial Substudy

Katharine Barnard; Timothy Wysocki; Vanessa Ully; Julia K. Mader; Thomas R. Pieber; Hood Thabit; Martin Tauschmann; Lalantha Leelarathna; Sara Hartnell; Carlo L. Acerini; Malgorzata E. Wilinska; Sibylle Dellweg; Carsten Benesch; Sabine Arnolds; Manuel Holzer; Harald Kojzar; Fiona Campbell; James Yong; Jennifer Pichierri; Peter C. Hindmarsh; Lutz Heinemann; Mark L. Evans; Roman Hovorka

Objective: The objective was to explore psychosocial experiences of closed loop technology for adults, children, and adolescents with type 1 diabetes and their parents taking part in two multicenter, free-living, randomized crossover home studies. Methods: Participants using insulin pump therapy were randomized to either 12 weeks of automated closed-loop glucose control, then 12 weeks of sensor augmented insulin pump therapy (open loop), or vice versa. Closed loop was used for 24 hours by adults and overnight only by children and adolescents. Participants completed the Diabetes Technology Questionnaire (DTQ) periodically and shared their views in semistructured interviews. This analysis characterizes the impact of the technology, positive and negative aspects of living with the device, alongside participants’ expectations, hopes, and anxieties. Results: Participants were 32 adults, age 38.6 ± 9.6 years, 55% male, and 26 children, mean age 12 years (range 6-18 years), 54% male. DTQ results indicated moderately favorable impact of, and satisfaction with, both open and closed loop interventions, but little evidence of a comparative advantage of either. Key positive themes included perceived improved blood glucose control, improved general well-being, particularly on waking, improved sleep, reduced burden of diabetes, and visibility of data. Key negative themes included having to carry around the equipment and dislike of the pump and second cannula (ie, sensor) inserted. Conclusions: Overall, participants reported a positive experience of the closed loop technology. Results are consistent with previous research with size of equipment continuing to be a problem. Progress is being made in the usability of the closed-loop system.


Diabetic Medicine | 2015

Effectiveness of a multidisciplinary team approach to the prevention of readmission for acute glycaemic events

David Simmons; Sara Hartnell; J Watts; Candice Ward; Katy Davenport; E Gunn; Alison Jenaway

To describe the effect of a combined diabetes specialist/mental health team approach to prevent readmissions for acute glycaemic events among patients with diabetes.


Diabetes Care | 2018

Day-and-Night Closed-Loop Insulin Delivery in a Broad Population of Pregnant Women With Type 1 Diabetes: A Randomized Controlled Crossover Trial

Zoe A. Stewart; Malgorzata E Wilinska; Sara Hartnell; Leanne K. O’Neil; Gerry Rayman; Eleanor M. Scott; Katharine Barnard; Conor Farrington; Roman Hovorka; Helen R. Murphy

OBJECTIVE Despite advances in technology, optimal glucose control remains elusive and neonatal complications remain ubiquitous in type 1 diabetes (T1D) pregnancy. Our aim was to examine the safety, efficacy, and longer-term feasibility of day-and-night closed-loop insulin delivery. RESEARCH DESIGN AND METHODS We recruited 16 pregnant women (mean [SD]: age 32.8 [5.0] years, T1D duration 19.4 [10.2] years, HbA1c 8.0% [1.1], and BMI 26.6 [4.4] kg/m2) to an open-label, randomized, crossover trial. Participants completed 28 days of closed-loop and sensor-augmented pump (SAP) insulin delivery separated by a washout period. Afterward, participants could continue to use the closed-loop system up to 6 weeks postpartum. The primary end point was the proportion of time with glucose levels within the target range (63–140 mg/dL). RESULTS The proportion of time with glucose levels within target was comparable during closed-loop and SAP insulin delivery (62.3 vs. 60.1% [95% CI −4.1 to 8.3]; P = 0.47). Mean glucose and time spent hyperglycemic >140 mg/dL also did not differ (131.4 vs. 131.4 mg/dL [P = 0.85] and 36.6 vs. 36.1% [P = 0.86], respectively). During closed-loop, fewer hypoglycemic episodes occurred (median 8 [range 1–17] vs. 12.5 [1–53] over 28 days; P = 0.04) and less time at <63 mg/dL (1.6 vs. 2.7%; P = 0.02). Hypoglycemia <50 mg/dL (0.24 vs. 0.47%; P = 0.03) and low blood glucose index (1.0 vs. 1.4; P = 0.01) were lower. Less nocturnal hypoglycemia (2300–0700 h) during closed-loop therapy (1.1 vs. 2.7%; P = 0.008) and a trend toward higher overnight time in target (67.7 vs. 60.6%; P = 0.06) were found. CONCLUSIONS Closed-loop insulin delivery was associated with comparable glucose control and significantly less hypoglycemia than SAP therapy. Larger, longer-duration multicenter trials are now indicated to determine clinical efficacy of closed-loop insulin delivery in T1D pregnancy and the impact on neonatal outcomes.


Diabetes Research and Clinical Practice | 2012

Successful use of acarbose to manage post-prandial glycaemia in two patients with type 1 diabetes on continuous subcutaneous insulin infusion

Satya Dash; Sarah Crisp; Sara Hartnell; Sarah Donald; Katy Davenport; David Simmons; Mark L. Evans

Post-prandial hyperglycaemia is a particular problem for some patients with diabetes despite administering continuous subcutaneous insulin infusion (CSII) to deliver insulin flexibly. We describe two cases of patients on CSII with persistent post-prandial hyperglycaemia despite varying insulin doses and timing. Treatment with acarbose improved their glycaemic control.

Collaboration


Dive into the Sara Hartnell's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hood Thabit

University of Cambridge

View shared research outputs
Top Co-Authors

Avatar

Harald Kojzar

Medical University of Graz

View shared research outputs
Top Co-Authors

Avatar

Julia K. Mader

Medical University of Graz

View shared research outputs
Top Co-Authors

Avatar

Thomas R. Pieber

Medical University of Graz

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sabine Arnolds

Medical University of Graz

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge