Sarah E. Tobkin
University of Oklahoma
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sarah E. Tobkin.
Nutrition & Metabolism | 2008
Jordan R. Moon; Sarah E. Tobkin; Michael D. Roberts; Vincent J. Dalbo; Chad M. Kerksick; Michael G. Bemben; Joel T. Cramer; Jeffrey R. Stout
BackgroundTotal body water (TBW) estimations have been used to estimate body composition, particularly fat-free mass, to aid in nutritional interventions, and to monitor hydration status. In the past, bioimpedance spectroscopy (BIS) devices have been used to estimate TBW. Previous investigations have examined the validity of the XiTRON 4000B (XiTRON Technologies) BIS device for estimating TBW. Recently, a new BIS device (Imp™ SFB7) has become available, claiming greater precision when estimating TBW. The Imp™ SFB7 (SFB7) is based on similar BIS principles, while offering increased portability and a greater range of frequencies when compared to older devices, such as the XiTRON 4000B (4000B). The purpose of this study was to examine the validity of the SFB7 for estimating total body water in healthy college-age men and women compared to the 4000B and deuterium oxide (D2O).MethodsTwenty-eight Caucasian men and women (14 men, 14 women; 24 ± 4 yrs; 174.6 ± 8.7 cm; 72.80 ± 17.58 kg) had their TBW estimated by the SFB7, the 4000B, and D2O.ResultsBoth BIS devices produced similar standard error of estimate (SEE) and r values (SFB7, SEE = 2.12L, r = 0.98; 4000B, SEE = 2.99L, r = 0.96) when compared to D2O, though a significant constant error (CE) was detected for the 4000B (2.26L, p ≤ 0.025). The 4000B produced a larger total error (TE) and CE (TE = 3.81L, CE = 2.26L) when compared to the SFB7 (TE = 2.21L, CE = -0.09L). Additionally, the limits of agreement were larger for the 4000B (-3.88 to 8.39L) than the SFB7 (-4.50 to 4.31L). These results were consistent when sex was analyzed separately, though women produced lower SEE and TE values for both devices.ConclusionThe 4000B and SFB7 are valid BIS devices when compared to D2O to estimate TBW in college-age Caucasian men and women. Furthermore, the new SFB7 device displayed greater precision in comparison to the 4000B, which may decrease the error when estimating TBW on an individual basis.
Dynamic Medicine | 2008
Jordan R. Moon; Sarah E. Tobkin; Abbie E. Smith; Michael D. Roberts; Eric D. Ryan; Vincent J. Dalbo; Chris M Lockwood; Ashley A. Walter; Joel T. Cramer; Travis W. Beck; Jeffrey R. Stout
BackgroundMethods used to estimate percent body fat can be classified as a laboratory or field technique. However, the validity of these methods compared to multiple-compartment models has not been fully established. The purpose of this study was to determine the validity of field and laboratory methods for estimating percent fat (%fat) in healthy college-age men compared to the Siri three-compartment model (3C).MethodsThirty-one Caucasian men (22.5 ± 2.7 yrs; 175.6 ± 6.3 cm; 76.4 ± 10.3 kg) had their %fat estimated by bioelectrical impedance analysis (BIA) using the BodyGram™ computer program (BIA-AK) and population-specific equation (BIA-Lohman), near-infrared interactance (NIR) (Futrex® 6100/XL), four circumference-based military equations [Marine Corps (MC), Navy and Air Force (NAF), Army (A), and Friedl], air-displacement plethysmography (BP), and hydrostatic weighing (HW).ResultsAll circumference-based military equations (MC = 4.7% fat, NAF = 5.2% fat, A = 4.7% fat, Friedl = 4.7% fat) along with NIR (NIR = 5.1% fat) produced an unacceptable total error (TE). Both laboratory methods produced acceptable TE values (HW = 2.5% fat; BP = 2.7% fat). The BIA-AK, and BIA-Lohman field methods produced acceptable TE values (2.1% fat). A significant difference was observed for the MC and NAF equations compared to both the 3C model and HW (p < 0.006).ConclusionResults indicate that the BP and HW are valid laboratory methods when compared to the 3C model to estimate %fat in college-age Caucasian men. When the use of a laboratory method is not feasible, BIA-AK, and BIA-Lohman are acceptable field methods to estimate %fat in this population.
Nutrition & Metabolism | 2008
Christopher M. Lockwood; Jordan R. Moon; Sarah E. Tobkin; Ashley A. Walter; Abbie E. Smith; Vincent J. Dalbo; Joel T. Cramer; Jeffrey R. Stout
BackgroundExercise and high-protein/reduced-carbohydrate and -fat diets have each been shown separately, or in combination with an energy-restricted diet to improve body composition and health in sedentary, overweight (BMI > 25) adults. The current study, instead, examined the physiological response to 10 weeks of combined aerobic and resistance exercise (EX) versus exercise + minimal nutrition intervention designed to alter the macronutrient profile, in the absence of energy restriction, using a commercially available high-protein/low-carbohydrate and low-fat, nutrient-dense food supplement (EXFS); versus control (CON).MethodsThirty-eight previously sedentary, overweight subjects (female = 19; male = 19) were randomly assigned to either CON (n = 10), EX (n = 14) or EXFS (n = 14). EX and EXFS participated in supervised resistance and endurance training (2× and 3×/wk, respectively); EXFS consumed 1 shake/d (weeks 1 and 2) and 2 shakes/d (weeks 3–10).ResultsEXFS significantly decreased total energy, carbohydrate and fat intake (-14.4%, -27.2% and -26.7%, respectively; p < 0.017), and increased protein and fiber intake (+52.1% and +21.2%, respectively; p < 0.017). EX and EXFS significantly decreased fat mass (-4.6% and -9.3%, respectively; p < 0.017), with a greater (p < 0.05) decrease in EXFS than EX and CON. Muscle mass increase only reached significance in EXFS (+2.3%; p < 0.017), which was greater (p < 0.05) than CON but not EX (+1.1%). Relative VO2max improved in both exercise groups (EX = +5.0% and EXFS = +7.9%; p < 0.017); however, only EXFS significantly improved absolute VO2max (+6.2%; p = 0.001). Time-to-exhaustion during treadmill testing increased in EX (+9.8%) but was significantly less (p < 0.05) than in EXFS (+21.2%). Total cholesterol and LDL decreased only in the EXFS (-12.0% and -13.3%, respectively; p < 0.017). Total cholesterol-to-HDL ratio, however, decreased significantly (p < 0.017) in both exercise groups.ConclusionAbsent energy restriction or other dietary controls, provision of a high-protein/low-carbohydrate and -fat, nutrient-dense food supplement significantly, 1) modified ad libitum macronutrient and energy intake (behavior effect), 2) improved physiological adaptations to exercise (metabolic advantage), and 3) reduced the variability of individual responses for fat mass, muscle mass and time-to-exhaustion – all three variables improving in 100% of EXFS subjects.
Journal of Strength and Conditioning Research | 2009
Jordan R. Moon; Sarah E. Tobkin; Abbie E. Smith; Chris M Lockwood; Ashley A. Walter; Joel T. Cramer; Travis W. Beck; Jeffrey R. Stout
Moon, JR, Tobkin, SE, Smith, AE, Lockwood, CM, Walter, AA, Cramer, JT, Beck, TW, and Stout, JR. Anthropometric estimations of percent body fat in NCAA Division I female athletes: A 4-compartment model validation. J Strength Cond Res 23(4): 1068-1076, 2009-Anthropometric equations, based on 2-compartment models, have been routinely used to estimate body composition in female college athletes; however, these equations are not without error. In an attempt to decrease the error associated with anthropometric equations, updated equations were developed using multiple-compartment models, although the validity of these equations has not yet been established. The purpose of the current investigation was to determine the validity of the updated anthropometric equations and compare them with previously validated generalized equations for estimating percent fat (%fat) in female athletes. Twenty-nine white female NCAA Division I athletes (20 ± 1 years) volunteered to have their %fat estimated using anthropometric measurements. Skinfold equations included generalized and updated equations and a height and weight-based equation. %fat values were compared with a criterion 4-compartment model. All equations produced low total error (TE) (≤3.38%fat) and SEE values (≤2.97%fat) and high r values (r ≥ 0.78). The 2 updated skinfold equations produced the highest constant error (CE) values, but the tightest limits of agreement (≤ −1.58 ± 4.86%fat; CE ± 2SD) compared with the 3 generalized Jackson et al. equations (≤0.92 ± 5.34%fat), whereas the limits of agreement for the height and weight-based equation (± 6.00%fat) were the widest. Compared with the updated skinfold equations, the generalized Jackson et al. skinfold equations produced nearly identical TE values. Results suggest that the updated skinfold equations are valid but not superior to the generalized Jackson et al. equations, and the height and weight-based equation of Fornetti et al. is not recommended due to the large individual error in this population. Additionally, more than 3 skinfold sites did not improve %fat values. Therefore, the Jackson et al. sum of 3 skinfold equation is the suggested skinfold equation in the white female NCAA Division I athletes.
Journal of The International Society of Sports Nutrition | 2007
Jordan R. Moon; Holly R. Hull; Sarah E. Tobkin; Masaru Teramoto; Murat Karabulut; Michael D. Roberts; Eric D. Ryan; So Jung Kim; Vincent J. Dalbo; Ashley A. Walter; Abbie Smith; Joel T. Cramer; Jeffrey R. Stout
BackgroundMethods used to estimate percent body fat can be classified as a laboratory or field technique. However, the validity of these methods compared to multiple-compartment models has not been fully established. This investigation sought to determine the validity of field and laboratory methods for estimating percent fat (%fat) in healthy college-age women compared to the Siri three-compartment model (3C).MethodsThirty Caucasian women (21.1 ± 1.5 yrs; 164.8 ± 4.7 cm; 61.2 ± 6.8 kg) had their %fat estimated by BIA using the BodyGram™ computer program (BIA-AK) and population-specific equation (BIA-Lohman), NIR (Futrex® 6100/XL), a quadratic (SF3JPW) and linear (SF3WB) skinfold equation, air-displacement plethysmography (BP), and hydrostatic weighing (HW).ResultsAll methods produced acceptable total error (TE) values compared to the 3C model. Both laboratory methods produced similar TE values (HW, TE = 2.4%fat; BP, TE = 2.3%fat) when compared to the 3C model, though a significant constant error (CE) was detected for HW (1.5%fat, p ≤ 0.006). The field methods produced acceptable TE values ranging from 1.8 – 3.8 %fat. BIA-AK (TE = 1.8%fat) yielded the lowest TE among the field methods, while BIA-Lohman (TE = 2.1%fat) and NIR (TE = 2.7%fat) produced lower TE values than both skinfold equations (TE > 2.7%fat) compared to the 3C model. Additionally, the SF3JPW %fat estimation equation resulted in a significant CE (2.6%fat, p ≤ 0.007).ConclusionData suggest that the BP and HW are valid laboratory methods when compared to the 3C model to estimate %fat in college-age Caucasian women. When the use of a laboratory method is not feasible, NIR, BIA-AK, BIA-Lohman, SF3JPW, and SF3WB are acceptable field methods to estimate %fat in this population.
Clinical Nutrition | 2009
Jordan R. Moon; Abbie E. Smith; Sarah E. Tobkin; Christopher M. Lockwood; Kristina L. Kendall; Jennifer L Graef; Michael D. Roberts; Vincent J. Dalbo; Chad M. Kerksick; Joel T. Cramer; Travis W. Beck; Jeffrey R. Stout
BACKGROUND & AIMS Bioimpedance spectroscopy (BIS) for the estimation of total body water (TBW) has advantages over isotope dilution techniques, including cost, portability, and ease of use. The aim of the current study was to determine the validity of a BIS device (Imp SFB7) for tracking changes in overfat and obese individuals. METHODS Sixty overfat and obese men and women (27+/-8 yr, 33.41+/-3.81%fat) participated in the study. TBW was estimated using BIS and deuterium oxide (D(2)O) before and after the ten-week intervention. RESULTS Pre-and post-intervention BIS TBW estimations errors increased as body mass index (BMI), fat mass (FM), and fat-free mass (FFM) increased (p<0.05). Delta values were more accurate than pre- and post-TBW estimations (total error=1.45 L). Age significantly influenced pre- and post-TBW errors (p<0.05). Therefore, a regression equation was developed to correct for the pre- and post-BIS-estimated TBW errors: D(2)O TBW=11.478+0.743(BIS TBW)-2.429(Gender), (Men=1, Women=2). CONCLUSIONS BIS can be considered an accurate tool for tracking changes in TBW regardless of variations in BMI, FM, FFM, or age in both overfat and obese men and women (BMI>24). Employing a BIS TBW equation is suggested over the development of resistivity coefficients based on BMI, FM, FFM or age.
Journal of Strength and Conditioning Research | 2010
Christopher M. Lockwood; Jordan R. Moon; Abbie E. Smith; Sarah E. Tobkin; Kristina L. Kendall; Jennifer L Graef; Joel T. Cramer; Jeffrey R. Stout
Lockwood, CM, Moon, JR, Smith, AE, Tobkin, SE, Kendall, KL, Graef, JL, Cramer, JT, and Stout, JR. Low-calorie energy drink improves physiological response to exercise in previously sendentary men: a placebo-controlled efficacy and safety study. J Strength Cond Res 24(8): 2227-2238, 2010-Energy drink use has grown despite limited research to support efficacy or safety and amid concerns when combined with exercise. The purpose of this study was to assess the effects of 10 weeks of once-daily energy drink consumption or energy drink consumption with exercise on measures of body composition, cardiorespiratory fitness, strength, mood, and safety in previously sedentary males. Thirty-eight males were randomly assigned to energy drink + exercise (EX-A), energy drink (NEX-A), placebo + exercise (EX-B), or placebo (NEX-B). All participants consumed 1 drink per day for 10 weeks; EX-A and EX-B participated in 10 weeks of resistance and endurance exercise. Testing was performed before (PRE) and after (POST) the 10-week intervention. No significant (p > 0.05) changes were observed for body composition, fitness, or strength in NEX-A; however, significantly greater decreases in fat mass and percentage body fat and increases in VO2peak were observed in EX-A versus EX-B. Ventilatory threshold (VT), minute ventilation, &OV0312;O2 at VT, and power output at VT improved significantly PRE to POST in EX-A but not in EX-B or nonexercising groups. Clinical markers for hepatic, renal, cardiovascular, and immune function, as determined by PRE and POST blood work revealed no adverse effects in response to the energy drink. Mood was not affected by energy drink use. Absent energy restriction or other dietary controls, chronic ingestion of a once-daily low-calorie energy drink appears ineffective at improving body composition, cardiorespiratory fitness, or strength in sedentary males. However, when combined with exercise, preworkout energy drink consumption may significantly improve some physiological adaptations to combined aerobic and resistance training.
Journal of Strength and Conditioning Research | 2008
Jordan R. Moon; Sarah E. Tobkin; Pablo B. Costa; Marcus Smalls; William K Mieding; Joseph OʼKroy; Robert F. Zoeller; Jeffrey R. Stout
The purpose of this study was to validate the percentage of body fat (%BF) values estimated from the BOD POD (BP) with those obtained from hydrostatic weighing (HW) in athletic American high school boys. Additionally, the %BF values measured via near-infrared interactance (NIR), bioelectrical impedance (BIA), and skinfold (SF) were compared to HW to determine the validity of these measures. Thirty white boys (mean age ± SD = 15.8 ± 1.0 years) who where currently participating in organized sports volunteered to have their %BF estimated. Measurements were obtained from NIR, BP, BIA, and SF in random order and concluded with HW. The findings from the present study indicated that the NIR and BIA instruments produced significant (P < 0.008) constant error (CE) and total error (TE) values that were too large to be of practical value (TE > 4.0%BF). The BP produced a significantly (P < 0.008) higher CE with acceptable TE values compared to HW, but compared to all three SF estimations, the BP TE values were higher. Two of the SF equations were nonsignificant (P > 0.008) and had the lowest TE values compared to HW. These data suggest that the BP can produce acceptable body fat measures for athletic white boys but is not superior to estimates made by the SF equations used in this study.
Journal of The International Society of Sports Nutrition | 2008
Jeffrey R. Stout; Jordan R. Moon; Sarah E. Tobkin; Christopher M. Lockwood; Abbie E. Smith; Jennifer L Graef; Kristina L. Kendall; Travis W. Beck; Joel T. Cramer
Background The functional beverage Celsius®, has recently been shown, after acute and chronic (28 days) consumption, to increase resting metabolism and serum blood markers of lipolysis in healthy, college-aged men and women. The purpose of this study was to examine the combined effects of a 10-week exercise program while consuming Celsius® on body composition and cardiorespiratory fitness changes in sedentary men and women.
European Journal of Applied Physiology | 2009
Jordan R. Moon; Joan M. Eckerson; Sarah E. Tobkin; Abbie E. Smith; Christopher M. Lockwood; Ashley A. Walter; Joel T. Cramer; Travis W. Beck; Jeffrey R. Stout