Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sebastian J. Osterfeld is active.

Publication


Featured researches published by Sebastian J. Osterfeld.


Nature Medicine | 2009

Matrix-insensitive protein assays push the limits of biosensors in medicine

Richard S. Gaster; Drew A. Hall; Carsten H. Nielsen; Sebastian J. Osterfeld; Heng Yu; Kathleen E. Mach; Robert J. Wilson; Boris Murmann; Joseph C. Liao; Sanjiv S. Gambhir; Shan X. Wang

Advances in biosensor technologies for in vitro diagnostics have the potential to transform the practice of medicine. Despite considerable work in the biosensor field, there is still no general sensing platform that can be ubiquitously applied to detect the constellation of biomolecules in diverse clinical samples (for example, serum, urine, cell lysates or saliva) with high sensitivity and large linear dynamic range. A major limitation confounding other technologies is signal distortion that occurs in various matrices due to heterogeneity in ionic strength, pH, temperature and autofluorescence. Here we present a magnetic nanosensor technology that is matrix insensitive yet still capable of rapid, multiplex protein detection with resolution down to attomolar concentrations and extensive linear dynamic range. The matrix insensitivity of our platform to various media demonstrates that our magnetic nanosensor technology can be directly applied to a variety of settings such as molecular biology, clinical diagnostics and biodefense.


Proceedings of the National Academy of Sciences of the United States of America | 2008

Multiplex protein assays based on real-time magnetic nanotag sensing

Sebastian J. Osterfeld; Heng Yu; Richard S. Gaster; Stefano Caramuta; Liang Xu; Shu-Jen Han; Drew A. Hall; Robert J. Wilson; Shouheng Sun; Robert L. White; Ronald W. Davis; Nader Pourmand; Shan X. Wang

Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.


Nature Nanotechnology | 2011

Quantification of protein interactions and solution transport using high-density GMR sensor arrays

Richard S. Gaster; Liang Xu; Shu-Jen Han; Robert J. Wilson; Drew A. Hall; Sebastian J. Osterfeld; Heng Yu; Shan X. Wang

Monitoring the kinetics of protein interactions on a high density sensor array is vital to drug development and proteomic analysis. Label-free kinetic assays based on surface plasmon resonance are the current gold standard, but they have poor detection limits, suffer from non-specific binding, and are not amenable to high throughput analyses. Here we show that magnetically responsive nanosensors that have been scaled to over 100,000 sensors/cm2 can be used to measure the binding kinetics of various proteins with high spatial and temporal resolution. We present an analytical model that describes the binding of magnetically labeled antibodies to proteins that are immobilized on the sensor surface. This model is able to quantify the kinetics of antibody-antigen binding at sensitivities as low as 20 zeptomoles of solute.


Biosensors and Bioelectronics | 2008

Giant Magnetoresistive Biochip for DNA Detection and HPV Genotyping

Liang Xu; Heng Yu; Michael S. Akhras; Shu-Jen Han; Sebastian J. Osterfeld; Robert L. White; Nader Pourmand; Shan X. Wang

A giant magnetoresistive (GMR) biochip based on spin valve sensor array and magnetic nanoparticle labels was developed for inexpensive, sensitive and reliable DNA detection. The DNA targets detected in this experiment were PCR products amplified from Human Papillomavirus (HPV) plasmids. The concentrations of the target DNA after PCR were around 10 nM in most cases, but concentrations of 10 pM were also detectable, which is demonstrated by experiments with synthetic DNA samples. A mild but highly specific surface chemistry was used for probe oligonucleotide immobilization. Double modulation technique was used for signal detection in order to reduce the 1/f noise in the sensor. Twelve assays were performed with an accuracy of approximately 90%. Magnetic signals were consistent with particle coverage data measured with Scanning Electron Microscopy (SEM). More recent research on microfluidics showed the potential of reducing the assay time below one hour. This is the first demonstration of magnetic DNA detection using plasmid-derived samples. This study provides a direct proof that GMR sensors can be used for biomedical applications.


Biosensors and Bioelectronics | 2010

GMR Biosensor Arrays: A System Perspective

Drew A. Hall; Richard S. Gaster; T. Lin; Sebastian J. Osterfeld; Shu-Jen Han; Boris Murmann; Shan X. Wang

Giant magnetoresistive biosensors are becoming more prevalent for sensitive, quantifiable biomolecular detection. However, in order for magnetic biosensing to become competitive with current optical protein microarray technology, there is a need to increase the number of sensors while maintaining the high sensitivity and fast readout time characteristic of smaller arrays (1-8 sensors). In this paper, we present a circuit architecture scalable for larger sensor arrays (64 individually addressable sensors) while maintaining a high readout rate (scanning the entire array in less than 4s). The system utilizes both time domain multiplexing and frequency domain multiplexing in order to achieve this scan rate. For the implementation, we propose a new circuit architecture that does not use a classical Wheatstone bridge to measure the small change in resistance of the sensor. Instead, an architecture designed around a transimpedance amplifier is employed. A detailed analysis of this architecture including the noise, distortion, and potential sources of errors is presented, followed by a global optimization strategy for the entire system comprising the magnetic tags, sensors, and interface electronics. To demonstrate the sensitivity, quantifiable detection of two blindly spiked samples of unknown concentrations has been performed at concentrations below the limit of detection for the enzyme-linked immunosorbent assay. Lastly, the multiplexing capability and reproducibility of the system was demonstrated by simultaneously monitoring sensors functionalized with three unique proteins at different concentrations in real-time.


Angewandte Chemie | 2009

Protein‐Functionalized Synthetic Antiferromagnetic Nanoparticles for Biomolecule Detection and Magnetic Manipulation

Aihua Fu; Wei Hu; Liang Xu; Robert J. Wilson; Heng Yu; Sebastian J. Osterfeld; Sanjiv S. Gambhir; Shan X. Wang

Direct protein functionalization provides synthetic antiferromagnetic nanoparticles with high chemical specificity and multifunctionality. These nanoparticle-protein conjugates function as improved magnetic labels for biological detection experiments, and exhibit tunable responses to a small external magnetic field gradient, thus allowing the observation of distinctive single nanoparticle motion.


Biosensors and Bioelectronics | 2010

GMR Biosensor Arrays: Correction Techniques for Reproducibility and Enhanced Sensitivity

Drew A. Hall; Richard S. Gaster; Sebastian J. Osterfeld; Boris Murmann; Shan X. Wang

Giant magnetoresistive biosensors possess great potential in biomedical applications for quantitatively detecting magnetically tagged biomolecules. Magnetic sensing does not suffer from the high background levels found in optical sensing modalities such as the enzyme linked immunosorbent assay translating into a technology with higher sensitivity. However, to reveal the full potential of these sensors and compensate for non-idealities such as temperature dependence, digital correction and calibration techniques are not only useful but imperative. Using these calibration techniques to correct for process variations and dynamic changes in the sensing environment (such as temperature and magnetic field), we are able to obtain extremely sensitive and, more importantly, reproducible results for quantifiable biomolecular reorganization. The reproducibility of the system was improved by over 3 x using digital correction techniques and the sensors are made temperature independent by using a novel background correction technique.


IEEE Transactions on Magnetics | 2008

Giant Magnetoresistive Sensors for DNA Microarray

Liang Xu; Heng Yu; Shu-Jen Han; Sebastian J. Osterfeld; Robert L. White; Nader Pourmand; Shan X. Wang

Giant magnetoresistive (GMR) sensors are developed for a DNA microarray. Compared with the conventional fluorescent sensors, GMR sensors are cheaper, more sensitive, can generate fully electronic signals, and can be easily integrated with electronics and microfluidics. The GMR sensor used in this work has a bottom spin valve structure with an MR ratio of 12%. The single-strand target DNA detected has a length of 20 bases. Assays with DNA concentrations down to 10 pM were performed, with a dynamic range of three logs. A double modulation technique was used in signal detection to reduce the 1/f noise in the sensor while circumventing electromagnetic interference. The logarithmic relationship between the magnetic signal and the target DNA concentration can be described by the Temkin isotherm. Furthermore, GMR sensors integrated with microfluidics has great potential of improving the sensitivity to 1 pM or below, and the total assay time can be reduced to less than 1 h .


Scientific Reports | 2013

Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation

Dokyoon Kim; Francesco Marchetti; Zuxiong Chen; Sasa Zaric; Robert J. Wilson; Drew A. Hall; Richard S. Gaster; Jung Rok Lee; J. C. Wang; Sebastian J. Osterfeld; Heng Yu; Robert M. White; William F. Blakely; Leif E. Peterson; Sandhya Bhatnagar; Brandon J. Mannion; Serena Tseng; Kristen Roth; Matthew Coleman; Antoine M. Snijders; Andrew J. Wyrobek; Shan X. Wang

Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations showed excellent dose discrimination at ≥ 1 Gy in the time window of 1 to 7 days after exposure except 1 Gy at day 7. Saa1 dose response was limited to the first two days after exposure. A multiplex assay with both proteins showed improved dose classification accuracy. Our magneto-nanosensor assay demonstrates the dose and time responses, low-dose sensitivity, small volume requirements, and rapid speed that have important advantages in radiation triage biodosimetry.


Scientific Reports | 2016

Experimental and theoretical investigation of the precise transduction mechanism in giant magnetoresistive biosensors

Jung-Rok Lee; Noriyuki Sato; Daniel J. B. Bechstein; Sebastian J. Osterfeld; J. C. Wang; Adi Wijaya Gani; Drew A. Hall; Shan X. Wang

Giant magnetoresistive (GMR) biosensors consisting of many rectangular stripes are being developed for high sensitivity medical diagnostics of diseases at early stages, but many aspects of the sensing mechanism remain to be clarified. Using e-beam patterned masks on the sensors, we showed that the magnetic nanoparticles with a diameter of 50 nm located between the stripes predominantly determine the sensor signals over those located on the sensor stripes. Based on computational analysis, it was confirmed that the particles in the trench, particularly those near the edges of the stripes, mainly affect the sensor signals due to additional field from the stripe under an applied field. We also demonstrated that the direction of the average magnetic field from the particles that contributes to the signal is indeed the same as that of the applied field, indicating that the particles in the trench are pivotal to produce sensor signal. Importantly, the same detection principle was validated with a duplex protein assay. Also, 8 different types of sensor stripes were fabricated and design parameters were explored. According to the detection principle uncovered, GMR biosensors can be further optimized to improve their sensitivity, which is highly desirable for early diagnosis of diseases.

Collaboration


Dive into the Sebastian J. Osterfeld's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Drew A. Hall

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nader Pourmand

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge