Sérgio Lima Santiago
Federal University of Ceará
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sérgio Lima Santiago.
Photomedicine and Laser Surgery | 2009
Alessandra Helen Magacho Vieira; Vanara Florêncio Passos; Jorgiana Silva de Assis; Juliano Sartori Mendonça; Sérgio Lima Santiago
OBJECTIVES This study evaluated the immediate and 3 month clinical effects of a low-level gallium-aluminum-arsenide (GaAlAs) laser and a 3% potassium oxalate gel for the treatment of dentinal hypersensitivity. MATERIALS AND METHODS A total of 164 teeth from 30 patients with clinical diagnoses of dentinal hypersensitivity were selected for this randomized, placebo-controlled, double-blind clinical study. The teeth were randomized to three groups: GaAlAs laser, oxalate gel, and placebo gel. The treatment sessions were performed at 7 d intervals for four consecutive weeks. The degree of sensitivity in response to an air blast and tactile stimuli was assessed according to a visual analogue scale at baseline, immediately after the fourth application, and then 3 months after the fourth application. The reductions in dentinal hypersensitivity from baseline at the two follow-up assessments were evaluated as the main outcome. RESULTS In both the active and control groups, there were statistically significant reductions in dentinal hypersensitivity immediately after and 3 months after the treatments, when compared with the hypersensitivity at baseline. No significant differences among the three groups could be detected in their efficacy at either the immediate or 3 month evaluations irrespective of the stimulus. CONCLUSIONS The treatments under study were effective for reducing dentinal hypersensitivity, and longer observational periods could enhance the ability of studies to detect differences between active and placebo groups.
Brazilian Dental Journal | 2006
Sérgio Lima Santiago; José Carlos Pereira; Ana Christina Bonato Figueiredo Martineli
This study evaluated the influence of time after application of oxalate solutions in reducing dentin hydraulic conductance. Fifty dentin discs were obtained from extracted human third molars and assigned to 5 groups (n=10), according to the desensitizing agent used: Group I: OxaGel; Group II: experimental agent DD-1: Group III: experimental agent DD-2. In Groups IV and V, a placebo gel and deionized water were used as control, respectively. The agents were applied for 3 min, washed out and the hydraulic conductance was measured immediately and at 5-, 15- and 30-min intervals, and after acid etching. Data were analyzed statistically by two-way ANOVA and Duncans test at 5% significance level. Groups I, II and III did not differ significantly from each other in any of the time intervals (p>0.05). Likewise, Groups IV and V were statistically similar to each other (p>0.05). The active agents reduced significantly dentin permeability in comparison to control groups (p<0.05). Dentin permeability measured in vitro decreased significantly with time regardless of the agent applied (either active or control agents). The results of Group V, in which no dentin desensitizing agent was employed, indicates that the assessment of dentin permeability by this method must be interpreted with caution.
Microscopy Research and Technique | 2013
Vanara Florêncio Passos; Mary A.S. Melo; Andréa Araújo de Vasconcellos; Lidiany Karla Azevedo Rodrigues; Sérgio Lima Santiago
Various methods have been applied to evaluate the effect of erosion and abrasion. So, the aim of this study was to check the applicability of stylus profilometry (SP), surface hardness (SH) and focus‐variation 3D microscopy (FVM) to the analysis of human enamel and dentin subjected to erosion/abrasion. The samples were randomly allocated into four groups (n = 10): G1‐enamel/erosion, G2‐enamel/erosion plus abrasion, G3‐dentin/erosion, and G4‐dentin/erosion plus abrasion. The specimens were selected by their surface hardness, and they were subjected to cycles of demineralization (Coca‐Cola®‐60 s) and remineralization (artificial saliva‐60 min). For groups G2 and G4, the remineralization procedures were followed by toothbrushing (150 strokes). The above cycle was repeated 3×/day during 5 days. The samples were assessed using SH, SP, and FVM. For each substrate, the groups were compared using an unpaired t‐test, and Pearson correlation coefficients were calculated (α = 5%). For enamel, both profilometry technique showed greater surface loss when the erosion and abrasion processes were combined (P <0.05). The correlation analysis did not reveal any relationships among SH, SP, and FVM to G2 and G4. There were significant correlation coefficients (–0.70 and –0.67) for the comparisons between the FVM and SH methods in enamel and dentin, respectively, in G1 and G3. Choosing the ideal technique for the analysis of erosion depends on the type of dental substrate. SP was not sufficiently sensitive to measure the effects on dentin of erosion or erosion/abrasion. However, SP, FVM and SH were adequate for the detection of tissue loss and demineralization in enamel. Microsc. Res. Tech., 2013.
Brazilian Dental Journal | 2011
Jorgiana Silva de Assis; Lidiany Karla Azevedo Rodrigues; Cristiane Sá Roriz Fonteles; Regina Cláudia Ramos Colares; André Mattos Brito de Souza; Sérgio Lima Santiago
The aim of this study was to evaluate the efficacy of two desensitizing agents in the reduction of dentin hypersensitivity in a randomized, double-blind, split-mouth clinical trial. Seventy-seven teeth from 13 patients that presented some degree of sensitivity to probing and/or air stimulation were treated with one of the following desensitizing agents: Oxa-Gel (G1), Sensi Kill (G2) and placebo gel (G3 - control). According to paired t-test, all treatments, even the placebo gel, were capable of reducing sensitivity scores for both stimuli. Analysis of data by ANOVA and Tukeys test (?=0.05) showed that the sensitivity scores were significantly lower only for Sensi Kill in comparison to the other products (Oxa-Gel and placebo), when air stimulus was applied. It may be concluded that treatment with Sensi Kill presented a slightly better performance in reducing dentin hypersensitivity when compared to the other desensitizing agent.
Brazilian Dental Journal | 2013
Regina Cláudia Ramos Colares; Jiovanne Rabelo Neri; André Mattos Brito de Souza; Karina Matthes de Freitas Pontes; Juliano Sartori Mendonça; Sérgio Lima Santiago
The aim of this study was to evaluate the influence of ceramic surface treatments and silane drying temperature on the microtensile bond strength (µTBS) of a resin composite to a lithium disilicate ceramic. Twenty blocks (7x7x5 mm) of lithium disilicate-based hot-pressed ceramic were fabricated and randomly divided into 4 groups: G1: acid etching with 9.5% hydrofluoric acid for 20 s and drying silane with room-temperature air; G2: acid etching with 9.5% hydrofluoric acid for 20 s and drying silane with 45 ± 5 °C warm air; G3: airborne-particle abrasion with 50 µm aluminum oxide particles and drying silane with 45 ± 5 °C warm air; G4: airborne-particle abrasion with 50 µm aluminum oxide particles and drying silane with air at room-temperature. After treatments, an adhesive system (Single Bond 2) was applied, light-cured and direct restorations were built up with a resin composite (Filtek Z250). Each specimen was stored in distilled water at 37 °C for 24 h and cut into ceramic-composite beams with 1 mm2 of cross-sectional area for µTBS testing. Statistical analysis was performed with one-way ANOVA and Student-Newman-Keuls test (α=0.05). µTBS means (S.D.) in MPa were: G1: 32.14 (7.98), G2: 35.00 (7.77) and G3: 18.36 (6.17). All specimens of G4 failed during the cutting. G1 and G2 presented significantly higher µTBS than G3 (p<0.05). There was no statistically significant difference between G1 and G2 (p>0.05). As far as the bond strength is concerned, surface pretreatment of lithium-disilicate ceramic with hydrofluoric acid and silane application can be used as an alternative to repair ceramic restorations with composite resin, while surface pretreatment with sandblasting should be avoided.
Brazilian Dental Journal | 2010
Sérgio Lima Santiago; Vanara Florêncio Passos; Alessandra Helen Magacho Vieira; Maria Fidela de Lima Navarro; José Roberto Pereira Lauris; Eduardo Batista Franco
This controlled clinical trial evaluated the 2-year clinical performance of a one-bottle etch-and-rinse adhesive and resin composite system (Excite/Tetric Ceram) compared to a resin-modified glass ionomer cement (RMGIC) (Vitremer/3M) in non-carious cervical lesions. Seventy cervical restorations (35 resin composite - RC- restorations and 35 RMGIC restorations) were placed by a single operator in 30 patients under rubber dam isolation without mechanical preparation. All restorations were evaluated blindly by 2 independent examiners using the modified USPHS criteria at baseline, and after 6, 12 and 24 months. Data were analyzed statistically by Fishers exact and McNemar tests. After 2 years, 59 out of 70 restorations were evaluated. As much as 78.8% retention rate was recorded for RC restorations, while 100% retention was obtained for RMGIC restorations. Fishers exact test showed significant differences (p=0.011) for retention. However, there were no significant differences for marginal integrity, marginal discoloration, anatomic form and secondary caries between the RC and RMGIC restorations. The McNemar test detected significant differences for Excite/TC between baseline and the 2-year recall for retention (p=0.02), marginal integrity (p=0.002) and anatomic form (p=0.04). Therefore, the one-bottle etch-and-rinse bonding system/resin composite showed an inferior clinical performance compared to the RMGIC.
Journal of Applied Oral Science | 2003
Sérgio Lima Santiago; Eduardo Batista Franco; Juliano Sartori Mendonça; José Roberto Pereira Lauris; Maria Fidela de Lima Navarro
The purpose of this study was to assess the clinical performance of bonded composite (Excite/Tetric Ceram - Vivadent) versus a resin-modified glass ionomer cement (Vitremer - 3M) for restoring non-carious cervical lesions. A total of 70 restorations (thirty-five per material) were placed in 30 patients, 18-50 aged, by one operator. Rubber dam was employed in all cases, lesions were pumiced, enamel margins were not beveled, and no mechanical retention was placed. The restorations were directly assessed by two independent evaluators using modified-USPHS criteria for six clinical categories. The ratings for clinical acceptability restorations (alfa plus bravo) were as follows (Tetric Ceram/Vitremer): retention (86%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (97%/100%), postoperative sensitivity (100%/100%) and recurrent caries (100%/100%). Statistical analysis was completed with Fishers exact or Pearson Chi-square tests at a significance level of 5% (P<0.05). Results showed that almost all restorations were clinically satisfactory with no significant differences between materials groups. Five restorations of Excite/Tetric Ceram failed. No restorations of Vitremer have yet failed.
Brazilian Oral Research | 2013
Mary A.S. de-Melo; Diego da Costa Goes; Maria Denise Rodrigues de-Moraes; Sérgio Lima Santiago; Lidiany Karla Azevedo Rodrigues
This study evaluated the effect of a 2% chlorhexidine-based disinfectant (CHX) on the short-term resin-dentin bond strength of a self-etch adhesive system to human dentin with different mineral contents. Dentinal mineralization was tested at 4 levels (sound, and after 2, 4, or 8 days of demineralization-remineralization cycles) and disinfectant at 2 levels [deionized water (DW, negative control) and CHX]. Dentin demineralization induced by pH-cycling was characterized by cross-sectional hardness (CSH). Each dentin surface was divided into halves, one treated with DW and the other with CHX (5 minutes). Each surface was bonded with a self-etch adhesive system and restored. The specimens were sectioned and subjected to microtensile bond testing. CSH and microtensile bond strength (µTBS) data were analyzed by regression analysis and ANOVA-Tukey tests (α = 5%), respectively. The groups treated with CHX resulted in mean µTBS similar to those found for the groups in which the dentin was exposed to DW (p = 0.821). However, mean µTBS were strongly influenced by dentin mineralization (p < 0.05): the bond strength found for sound dentin was lower than that found for dentin cycled for 8 days, which was even lower than the bond strengths for dentin cycled for 2 or 4 days. The results suggest that the degree of dentin demineralization affects the bond strength of self-etching adhesives, but the use of CHX does not modify this effect.
Microscopy Research and Technique | 2013
Juliana Paiva Marques Lima; Mary A.S. Melo; Vanara Florêncio Passos; CÍcero L.N. Braga; Lidiany Karla Azevedo Rodrigues; Sérgio Lima Santiago
The aim of this study was to determine the erosive potential of hydrogen peroxide (HP) containing mouthwash on dentin assessed by Focus variation three‐dimensional (3D) microscopy. Twenty dentin slabs were selected and randomly allocated into two groups (n = 10): DW—Distilled water (pH = 7.27) and HP—1.5% (pH = 3.78). Each specimen was cyclically demineralized (4 × 60 s/day, 10 days) with HP or DW and brushed 3×/day (200 g, 150 strokes—toothpaste with 1,450 ppmF as NaF). Between the challenges, the specimens were exposed to artificial saliva. Afterward, dentin loss was analyzed using focus variation 3D microscopy, and the data were submitted to unpaired t‐test (α = 0.05). Statistically significant difference was found between the mean wear rate (μm, ±SD) of HP (1.98 ± 0.51) and DW (1.45 ± 0.39). The results suggest that the use of HP‐containing mouthwash associated to brushing may increase the risk of tissue loss and focus variation 3D microscopy may be used as a technique for quantifying dental wear. Microsc. Res. Tech. 76:904–908, 2013.
Photomedicine and Laser Surgery | 2014
Vanara Florêncio Passos; Mary Anne S. Melo; Francisco F.C. Silva; Lidiany Karla Azevedo Rodrigues; Sérgio Lima Santiago
OBJECTIVE This in vitro study aimed to evaluate the effect of a low intensity diode laser (λ=808 nm; 60 J/cm2) associated with stannous fluoride on the inhibition of dentin erosion by assessing percentage of superficial hardness loss (%SHL) and calcium release into the acid solution. MATERIALS AND METHODS Human root dentin slabs were assigned to eight groups (n=10), according to treatments (control, stannous fluoride, diode laser therapy, and the combination of stannous fluoride and laser therapy), and acid challenge (hydrochloridric or citric acid). All slabs were subjected to a previous 2 h acquired pellicle formation; laser and fluoride treatments were performed according to the groups. Subsequently, the slabs were exposed to erosive challenge (0.01 M hydrochloridric acid or citric acid 1% for 60 sec). Additionally, calcium released into the acid solution during erosive challenge was analyzed by photometric test. Data were analyzed by ANOVA followed by Tukeys test (p<0.05). RESULTS Mean values (±SD) for %SHL of treated groups did not present statistically significant differences, regardless of the erosive challenge. However, in relation to released calcium concentration, groups treated with laser presented statistically significant lower calcium loss under hydrochloridric acid challenge (p<0.001). To groups under citric acid attack, only the combination of treatments (p=0.037) was able to show a protective effect on dentin. CONCLUSIONS Under the conditions of this study, 808 nm diode laser with or without stannous fluoride could effectively reduce dentin surface loss under both acid exposures. Only calcium concentration analysis was sensitive enough to measure the effects under the tested conditions.