Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Seung-wook Shin is active.

Publication


Featured researches published by Seung-wook Shin.


ieee international conference on high performance computing data and analytics | 1994

A parallel algorithm for large-scale linear programs with a special structure

Seyoung Oh; Seung-wook Shin

A new sequential algorithm and computational results for large-scale linear programs with a special structure were presented previously by J.B. Rosen and S. Oh (1992). A parallel version of the algorithm is developed for a hypercube multiprocessor architecture NCUBE2. Computational results using 128 processors are presented for a randomly generated large-scale sparse or dense problems with the number of variables up to 256 and constraints up to 5 million.<<ETX>>


Archive | 2018

Design of Control System for Dual-Head Radiation Therapy

Hui Su Kim; Jungho Seo; Ho Namgoong; Seung-wook Shin; Mitra Ghergherehchi; J. Lee; Dirk Lipka; Donghyup Ha; Jong-Seo Chai

Sungkyunkwan University groups have been developed advanced radiation therapy machine named dual-head radiation therapy gantry for reducing the treatment time by up to 30%. The main difference between previous radiation therapy machine [1] is using two electron LINAC as X-ray sources at radiation therapy. In support of this system, control system based on SCADA and hardware development was implemented. The control system consists of supervisory computers and local controllers and the control network was ethernet and software was written by labVIEW. An overview of this control system is presented in paper. INTRODUCTION Sungkyunkwan University has developed a dual head radiation therapy system since 2012, which is a radiation therapy system that aims to reduce treatment time up to 30% than conventional radiation therapy machine [2]. To reduce treatment time, dual X-ray source, head are equipped with this system. developed dual-head gantry system is shown in Fig. 1. Those system configurations have economic benefits and advantages on account of reducing radiation treatment time but the additional installation of components result in space limit and a complexity of the system. To overcome space limit, we use 6 MeV Xband LINAC as X-ray source and it sufficiently reduce not only cavity volume but also waveguide and magnetron [3]. Controlling dual X-ray source is new challenge. in contrast to conventional TomoTherapy that use single X-ray source, dual head gantry system uses dual X-ray sources ssimultaneously or sequentially so control system requires supervisory control and sequence control that not only include data acquisition and monitoring but also two electron LINAC beam pulse synchronization. Figure 1: Dual-head Radiation therapy system. SYSTEM HARDWARE CONFIGURATION Developed gantry system is consist of subsystems such as two heads, electron LINAC and gantry robot and subsystems have each local controller. Head subsystem objective is to control the radiation path from the LINAC to the patient. It measures radiation dose rate and control X-ray field size. Its appearance is shown in Fig. 2 Head’s main control unit is Atmega2560 and control board has potential meters and limit switches for interlock. Figure 2: Gantry Head Appearance. Five motors in head system have each driver. By using daisy-chain scheme, master motor manages other slave motors as shown in Fig. 3. Figure 3: Gantry head system block diagram. 9th International Particle Accelerator Conference IPAC2018, Vancouver, BC, Canada JACoW Publishing ISBN: 978-3-95450-184-7 doi:10.18429/JACoW-IPAC2018-THPML076


Journal of Radioanalytical and Nuclear Chemistry | 2017

Development of new 116Cd/Pt target for cyclotron produced 117mSn as a medical radiometal

Seyoung Oh; Byungil Kim; Jung Young Kim; Mitra Ghergherehchi; Ho Seung Song; Seung-wook Shin; Jong Seo Chai

The radioisotope 117mSn has recently attracted considerable attention because of its application in theranostics and its imaging using 159-keV γ-photons. In this study, we developed a target system that yielded 117mSn via a 116Cd(α, 3n)117mSn nuclear reaction. A separable Pt substrate was utilized to prepare the enriched 116Cd target to be irradiated, and the enriched 116Cd in a cadmium acetate solution was electroplated onto the Pt substrate. The substrate was thermally analyzed via ANSYS simulations, and the plating thickness was optimized through calculations with TALYS code. The production of 117mSn was confirmed through the emission measurement of inherent gamma rays.


Journal of the Korean Physical Society | 2014

Design Study of an S-band RF Cavity of a Dual-Energy Electron LINAC for the CIS

Byeong-No Lee; Hyungdal Park; Kibaek Song; Yonggui Li; Byung Cheol Lee; Sungsu Cha; J. Lee; Seung-wook Shin; Jong-Seo Chai


5th Int. Particle Accelerator Conf. (IPAC'14), Dresden, Germany, June 15-20, 2014 | 2014

Design and Analysis of an Electron Beam in an Electron Gun for X-Ray Radiotherapy

J. Lee; Jong-Seo Chai; Mitra Ghergherehchi; Hui Su Kim; Byeong-No Lee; Yong-Seok Lee; Seung-wook Shin; Yeong Heum Yeon


Journal of the Korean Physical Society | 2013

Design study of a 9 MeV compact cyclotron system for PET

Byeong-No Lee; Seung-wook Shin; H. S. Song; Hyun-Wook Kim; Jong-Seo Chai


Archive | 2018

Using Deep Reinforcement Learning for Designing Sub-Relativistic Electron Linac

Seung-wook Shin; Jong-Seo Chai; Mitra Ghergherehchi


Journal of the Korean Physical Society | 2018

Erratum to: Measurement of Characteristic of X-band RF Cavity for 6 MeV Electron Linac

Seung-wook Shin; Seung-Hyun Lee; Seyoung Oh; Donghyup Ha; Mitra Ghergherehchi; Jong-Seo Chai; Byung-no Lee; Moonsik Chae


Journal of the Korean Physical Society | 2018

Measurement of Characteristic of X-band RF Cavity for 6 MeV Electron Linac

Seung-wook Shin; Seung-Hyun Lee; Seyoung Oh; Donghyup Ha; Mitra Ghergherehchi; Jong-Seo Chai; Byung-no Lee; Moonsik Chae


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2017

X-band Linac for a 6 MeV dual-head radiation therapy gantry

Seung-Hyun Lee; Seung-wook Shin; J. Lee; Huisu Kim; Byeong-No Lee; Byung-Chul Lee; Hyungdal Park; Ki-back Song; H. S. Song; SangChul Mun; Donghyup Ha; Jong-Seo Chai

Collaboration


Dive into the Seung-wook Shin's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Lee

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Donghyup Ha

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Seyoung Oh

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar

Ho Namgoong

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar

Hui Su Kim

Sungkyunkwan University

View shared research outputs
Researchain Logo
Decentralizing Knowledge