Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Shannon Faley is active.

Publication


Featured researches published by Shannon Faley.


Analytical Chemistry | 2009

Microfluidic Single-Cell Array Cytometry for the Analysis of Tumor Apoptosis

Donald Wlodkowic; Shannon Faley; Michele Zagnoni; John P. Wikswo; Jonathan M. Cooper

Limitations imposed by conventional analytical technologies for cell biology, such as flow cytometry or microplate imaging, are often prohibitive for the kinetic analysis of single-cell responses to therapeutic compounds. In this paper, we describe the application of a microfluidic array to the real-time screening of anticancer drugs against arrays of single cells. The microfluidic platform comprises an array of micromechanical traps, designed to passively corral individual nonadherent cells. This platform, fabricated in the biologically compatible elastomer poly(dimethylsiloxane), PDMS, enables hydrodynamic trapping of cells in low shear stress zones, enabling time-lapse studies of nonadherent hematopoietic cells. Results indicate that these live-cell, microfluidic microarrays can be readily applied to kinetic analysis of investigational anticancer agents in hematopoietic cancer cells, providing new opportunities for automated microarray cytometry and higher-throughput screening. We also demonstrate the ability to quantify on-chip the anticancer drug induced apoptosis. Specifically, we show that with small numbers of trapped cells (approximately 300) under careful serial observation we can achieve results with only slightly greater statistical spread than can be obtained with single-pass flow cytometer measurements of 15,000-30,000 cells.


Lab on a Chip | 2009

Microfluidic single cell arrays to interrogate signalling dynamics of individual, patient-derived hematopoietic stem cells

Shannon Faley; Mhairi Copland; Donald Wlodkowic; Walter Kolch; Kevin T. Seale; John P. Wikswo; Jonathan M. Cooper

Stem cells hold great promise as a means of treating otherwise incurable, degenerative diseases due to their ability both to self-renew and differentiate. However, stem cell damage can also play a role in the disease with the formation of solid tumors and leukaemias such as chronic myeloid leukaemia (CML), a hematopoietic stem cell (HSC) disorder. Despite recent medical advances, CML remains incurable by drug therapy. Understanding the mechanisms which govern chemoresistance of individual stem cell leukaemias may therefore require analysis at the single cell level. This task is not trivial using current technologies given that isolating HSCs is difficult, expensive, and inefficient due to low cell yield from patients. In addition, hematopoietic cells are largely non-adherent and thus difficult to study over time using conventional cell culture techniques. Hence, there is a need for new microfluidic platforms that allow the functional interrogation of hundreds of non-adherent single cells in parallel. We demonstrate the ability to perform assays, normally performed on the macroscopic scale, within the microfluidic platform using minimal reagents and low numbers of primary cells. We investigated normal and CML stem cell responses to the tyrosine kinase inhibitor, dasatinib, a drug approved for the treatment of CML. Dynamic, on-chip three-color cell viability assays revealed that differences in the responses of normal and CML stem/progenitor cells to dasatinib were observed even in the early phases of exposure, during which time normal cells exhibit a significantly elevated cell death rate, as compared to both controls and CML cells. Further studies show that dasatinib does, however, markedly reduce CML stem/progenitor cell migration in situ.


Lab on a Chip | 2008

Microfluidic platform for real-time signaling analysis of multiple single T cells in parallel.

Shannon Faley; Kevin T. Seale; Jacob J. Hughey; David K. Schaffer; Scott E. VanCompernolle; Brett A. McKinney; Franz J. Baudenbacher; Derya Unutmaz; John P. Wikswo

Deciphering the signaling pathways that govern stimulation of naïve CD4+ T helper cells by antigen-presenting cells via formation of the immunological synapse is key to a fundamental understanding of the progression of successful adaptive immune response. The study of T cell-APC interactions in vitro is challenging, however, due to the difficulty of tracking individual, non-adherent cell pairs over time. Studying single cell dynamics over time reveals rare, but critical, signaling events that might be averaged out in bulk experiments, but these less common events are undoubtedly important for an integrated understanding of a cellular response to its microenvironment. We describe a novel application of microfluidic technology that overcomes many limitations of conventional cell culture and enables the study of hundreds of passively sequestered hematopoietic cells for extended periods of time. This microfluidic cell trap device consists of 440 18 micromx18 micromx10 microm PDMS, bucket-like structures opposing the direction of flow which serve as corrals for cells as they pass through the cell trap region. Cell viability analysis revealed that more than 70% of naïve CD4+ T cells (TN), held in place using only hydrodynamic forces, subsequently remain viable for 24 hours. Cytosolic calcium transients were successfully induced in TN cells following introduction of chemical, antibody, or cellular forms of stimulation. Statistical analysis of TN cells from a single stimulation experiment reveals the power of this platform to distinguish different calcium response patterns, an ability that might be utilized to characterize T cell signaling states in a given population. Finally, we investigate in real time contact- and non-contact-based interactions between primary T cells and dendritic cells, two main participants in the formation of the immunological synapse. Utilizing the microfluidic traps in a daisy-chain configuration allowed us to observe calcium transients in TN cells exposed only to media conditioned by secretions of lipopolysaccharide-matured dendritic cells, an event which is easily missed in conventional cell culture where large media-to-cell ratios dilute cellular products. Further investigation into this intercellular signaling event indicated that LPS-matured dendritic cells, in the absence of antigenic stimulation, secrete chemical signals that induce calcium transients in T(N) cells. While the stimulating factor(s) produced by the mature dendritic cells remains to be identified, this report illustrates the utility of these microfluidic cell traps for analyzing arrays of individual suspension cells over time and probing both contact-based and intercellular signaling events between one or more cell populations.


Analytical Chemistry | 2009

Chip-Based Dynamic Real-Time Quantification of Drug-Induced Cytotoxicity in Human Tumor Cells

Donald Wlodkowic; Joanna Skommer; Dagmara McGuinness; Shannon Faley; Walter Kolch; Zbigniew Darzynkiewicz; Jonathan M. Cooper

Cell cytotoxicity tests are among the most common bioassays using flow cytometry and fluorescence imaging analysis. The permeability of plasma membranes to charged fluorescent probes serves, in these assays, as a marker distinguishing live from dead cells. Since it is generally assumed that probes, such as propidium iodide (PI) or 7-amino-actinomycin D (7-AAD), are themselves cytotoxic, they are currently generally used only as the end-point markers of assays for live versus dead cells. In the current study, we provide novel insights into potential applications of these classical plasma membrane integrity markers in the dynamic tracking of drug-induced cytotoxicity. We show that treatment of a number of different human tumor cell lines in cultures for up to 72 h with the PI, 7-AAD, SYTOX Green (SY-G), SYTOX Red (SY-R), TO-PRO, and YO-PRO had no effect on cell viability assessed by the integrity of plasma membrane, cell cycle progression, and rate of proliferation. We subsequently explore the potential of dynamic labeling with these markers in real-time analysis, by comparing results from both conventional cytometry and microfluidic chips. Considering the simplicity of the staining protocols and their low cost combined with the potential for real-time data collection, we show how that real-time fluorescent imaging and Lab-on-a-Chip platforms have the potential to be used for automated drug screening routines.


Analytical Chemistry | 2009

Biological implications of polymeric microdevices for live cell assays.

Donald Wlodkowic; Shannon Faley; Joanna Skommer; Dagmara McGuinness; Jonathan M. Cooper

Lab-on-a-chip technologies have the potential to deliver significant technological advances in modern biomedicine, through the ability to provide appropriate low-cost microenvironments for screening cells. However, to date, few studies have investigated the suitability of poly(dimethylsiloxane) (PDMS) for live cell culture. Here, we describe an inexpensive method for production of reusable, optical-grade PDMS microculture chips which provide a static and self-contained microwell system analogous to conventional polystyrene multiwell plates. We use these structures to probe the effects of PDMS upon live cell culture bioassays, using time-lapse fluorescence imaging to explore the toxicity of the substrate. We use three model systems to explore the efficacy of the microstructured devices: (i) live cell culture, (ii) adenoviral gene delivery to mammalian cells, and (iii) gravity enforced formation of multicellular tumor spheroids (MCTS). Results show that PDMS is nontoxic to cells, as their viability and growth characteristic in PDMS-based platforms is comparable to that of their polystyrene counterparts.


Advanced Healthcare Materials | 2016

Development of 3D Microvascular Networks Within Gelatin Hydrogels Using Thermoresponsive Sacrificial Microfibers.

Jung Bok Lee; Xintong Wang; Shannon Faley; Bradly Baer; Daniel A. Balikov; Hak-Joon Sung; Leon M. Bellan

A 3D microvascularized gelatin hydrogel is produced using thermoresponsive sacrificial poly(N-isopropylacrylamide) microfibers. The capillary-like microvascular network allows constant perfusion of media throughout the thick hydrogel, and significantly improves the viability of human neonatal dermal fibroblasts encapsulated within the gel at a high density.


Biomicrofluidics | 2011

Cell chip array for microfluidic proteomics enabling rapid in situ assessment of intracellular protein phosphorylation

Shannon Faley; Mhairi Copland; Julien Reboud; Jonathan M. Cooper

We discuss the ability to perform fluorescent immunocytochemistry, following cell fixation, using a microfluidic array of primary, nonadherent, single CD34+ stem cells. The technique requires small cell samples and proceeds with no cell loss, making it well-suited to monitoring these rare patient-derived cells. The chip allows us to correlate live cell dynamics across arrays of individual cells with post-translational modifications of intracellular proteins, following their exposure to drug treatments. Results also show that due to the microfluidic environment, the time scale of cell fixation was significantly reduced compared to conventional methods, leading to greater confidence in the status of the protein modifications studied.


Methods of Molecular Biology | 2011

Real-Time Cytotoxicity Assays

Donald Wlodkowic; Shannon Faley; Zbigniew Darzynkiewicz; Jonathan M. Cooper

Validation of new therapeutic targets calls for the advance in innovative assays that probe both spatial and temporal relationships in signaling networks. Cell death assays have already found a widespread use in pharmacological profiling of anticancer drugs. Such assays are, however, predominantly restricted to end point DEAD/LIVE parameter that provides only a snapshot of inherently stochastic process such as tumor cell death. Development of new methods that can offer kinetic real-time analysis would be highly advantageous for the pharmacological screening and predictive toxicology. In the present work we outline innovative protocols for the real-time analysis of tumor cell death, based on propidium iodide (PI) and SYTOX Green probes. These can be readily adapted to both flow cytometry and time-lapse fluorescence imaging. Considering vast time savings and kinetic data acquisition such assays have the potential to be applied in a number of areas including accelerated anticancer drug discovery and high-throughput screening routines.


IEEE Transactions on Nanobioscience | 2006

Quantum Dot Probes for Monitoring Dynamic Cellular Response: Reporters of T Cell Activation

Michael R. Warnement; Shannon Faley; John P. Wikswo; Sandra J. Rosenthal

Antibody-conjugated quantum dots (QDs) have been used to map the expression dynamics of the cytokine receptor interleukin-2 receptor-alpha (IL-2Ralpha) following Jurkat T cell activation. Maximal receptor expression was observed 48 h after activation, followed by a sharp decrease consistent with IL-2R internalization subsequent to IL-2 engagement. Verification of T cell activation and specificity of QD labeling were demonstrated using fluorescence microscopy, ELISA, and FACS analyses. These antibody conjugates provide a versatile means to rapidly determine cell state and interrogate membrane associated proteins involved in cell signaling pathways. Ultimately, incorporation with a microfluidic platform capable of simultaneously monitoring several cell signaling pathways will aid in toxin detection and discrimination


Experimental Biology and Medicine | 2010

Macro to nano: a simple method for transporting cultured cells from milliliter scale to nanoliter scale.

Kevin T. Seale; Shannon Faley; Jeffrey W. Chamberlain; John P. Wikswo

Microfluidic devices are well-suited for the study of metabolism and paracrine and autocrine signaling because they allow steady or intermittent perfusion of biological cells at cell densities that approach those in living tissue. They also enable the study of small populations of rare cells. However, it can be difficult to introduce the cells into a microfluidic device to achieve and control such densities without damaging or clumping the cells. We describe simple procedures that address the problem of efficient introduction of cells and cell culture media into microfluidic devices using small bore polyetheretherketone (PEEK) tubing and Hamilton gastight syringes. Suspension or adherent cells grown in cell culture flasks are centrifuged and extracted directly from the centrifuge pellet into the end of the PEEK tubing by aspiration. The tube end is then coupled to prepunched channels in the polydimethylsiloxane microfluidic device by friction fitting. Controlled depression of the syringe plunger expels the cells into the microfluidic device only seconds following aspiration. The gastight syringes and PEEK tubing with PEEK fittings provide a non-compliant source of pressure and suction with a rapid response time that is well suited for short-term intramicrofluidic cellular studies. The benefits of this method are its simplicity, modest expense, the short preparation time required for loading appropriate numbers of cells and the applicability of the technique to small quantities of rare or expensive cells. This should in turn lead to new applications of microfluidic devices to biology and medicine.

Collaboration


Dive into the Shannon Faley's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge