Featured researches published by Shuai Leng.


Medical Physics | 2008

Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Guang-Hong Chen; Jie Tang; Shuai Leng

When the number of projections does not satisfy the Shannon/Nyquist sampling requirement, streaking artifacts are inevitable in x-ray computed tomography (CT) images reconstructed using filtered backprojection algorithms. In this letter, the spatial-temporal correlations in dynamic CT imaging have been exploited to sparsify dynamic CT image sequences and the newly proposed compressed sensing (CS) reconstruction method is applied to reconstruct the target image sequences. A prior image reconstructed from the union of interleaved dynamical data sets is utilized to constrain the CS image reconstruction for the individual time frames. This method is referred to as prior image constrained compressed sensing (PICCS). In vivo experimental animal studies were conducted to validate the PICCS algorithm, and the results indicate that PICCS enables accurate reconstruction of dynamic CT images using about 20 view angles, which corresponds to an under-sampling factor of 32. This undersampling factor implies a potential radiation dose reduction by a factor of 32 in myocardial CT perfusion imaging.


Radiology | 2011

CT dose index and patient dose: They are not the same thing

Cynthia H. McCollough; Shuai Leng; Lifeng Yu; Dianna D. Cody; John M. Boone; Michael F. McNitt-Gray

Estimates of individual patient risk, and epidemiologic studies assessing potential late effects, must use patient size–specific dose estimates—they cannot use only scanner output (volume CT dose index or dose-length product).


American Journal of Roentgenology | 2012

Dual-energy CT-based monochromatic imaging.

Lifeng Yu; Shuai Leng; Cynthia H. McCollough

OBJECTIVE We summarize how virtual monochromatic images are synthesized from dual-energy CT using image-domain and projection-domain methods. The quality of virtual monochromatic images is compared with that of polychromatic single-energy images acquired at different tube potentials and the same radiation dose. Clinical applications of dual-energy CT-based virtual monochromatic imaging are reviewed, including beam-hardening correction, contrast and noise optimization, metal artifact reduction, and material differentiation. CONCLUSION Virtual monochromatic images synthesized from dual-energy CT data have the potential to reduce beam-hardening artifacts and to provide quantitative measurements. If there is no desire to obtain material-specific information or to correct for metal or beam-hardening artifacts from the dual-energy data, however, it is better to perform a conventional single-energy scan at the optimal tube potential.


Medical Physics | 2011

Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality

Lifeng Yu; Jodie A. Christner; Shuai Leng; Jia Wang; Joel G. Fletcher; Cynthia H. McCollough

PURPOSE To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. METHODS In dual-energy CT, besides the material-specific information, one may also synthesize monochromatic images at different energies, which can be used for routine diagnosis similar to conventional polychromatic single-energy images. In this work, the authors assessed whether virtual monochromatic images generated from dual-source CT scanners had an image quality similar to that of polychromatic single-energy images for the same radiation dose. First, the authors provided a theoretical analysis of the optimal monochromatic energy for either the minimum noise level or the highest iodine contrast to noise ratio (CNR) for a given patient size and dose partitioning between the low- and high-energy scans. Second, the authors performed an experimental study on a dual-source CT scanner to evaluate the noise and iodine CNR in monochromatic images. A thoracic phantom with three sizes of attenuating rings was used to represent four adult sizes. For each phantom size, three dose partitionings between the low-energy (80 kV) and the high-energy (140 kV) scans were used in the dual-energy scan. Monochromatic images at eight energies (40 to 110 keV) were generated for each scan. Phantoms were also scanned at each of the four polychromatic single energy (80, 100, 120, and 140 kV) with the same radiation dose. RESULTS The optimal virtual monochromatic energy depends on several factors: phantom size, partitioning of the radiation dose between low- and high-energy scans, and the image quality metrics to be optimized. With the increase of phantom size, the optimal monochromatic energy increased. With the increased percentage of radiation dose on the low energy scan, the optimal monochromatic energy decreased. When maximizing the iodine CNR in monochromatic images, the optimal energy was lower than that when minimizing noise level. When the total radiation dose was equally distributed between low and high energy in dual-energy scans, for minimum noise, the optimal energies were 68, 71, 74, and 77 keV for small, medium, large, and extra-large (xlarge) phantoms, respectively; for maximum iodine CNR, the optimal energies were 66, 68, 70, 72 keV. With the optimal monochromatic energy, the noise level was similar to and the CNR was better than that in a single-energy scan at 120 kV for the same radiation dose. Compared to an 80 kV scan, however, the iodine CNR in monochromatic images was lower for the small, medium, and large phantoms. CONCLUSIONS In dual-source dual-energy CT, optimal virtual monochromatic energy depends on patient size, dose partitioning, and the image quality metric optimized. With the optimal monochromatic energy, the noise level was similar to and the iodine CNR was better than that in 120 kV images for the same radiation dose. Compared to single-energy 80 kV images, the iodine CNR in virtual monochromatic images was lower for small to large phantom sizes.


Radiology | 2011

Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation

Katrina N. Glazebrook; Luís S. Guimarães; Naveen S. Murthy; David F. Black; Tim Bongartz; Nisha J. Manek; Shuai Leng; Joel G. Fletcher; Cynthia H. McCollough

PURPOSE To estimate the accuracy, sensitivity, specificity, and interobserver agreement of dual-energy computed tomography (CT) in detection of uric acid crystals in joints or periarticular structures in patients with arthralgia and patients suspected of having gout, with joint aspiration results as reference standard. MATERIALS AND METHODS With institutional review board approval, patient consent, and HIPAA compliance, 94 patients (age range, 29-89 years) underwent dual-source, dual-energy (80 and 140 kVp) CT of a painful joint. A material decomposition algorithm was used to identify uric acid. Two blinded musculoskeletal radiologists evaluated the dual-energy CT images and classified the examination findings as positive or negative for the presence of uric acid crystals. Reference standard was the result of joint aspiration. RESULTS Forty-three of 94 patients (46%) underwent attempted joint aspiration within 1 month of dual-energy CT. Aspiration was successful in 31 of 43 patients (72%). In 12 of 31 patients (39%), uric acid crystals were identified at joint aspiration; in 19 patients, they were not. Readers 1 and 2 had no false-negative findings for uric acid at dual-energy CT. Sensitivity was 100% (12 of 12; 95% confidence interval (CI): 74%, 100%) for both readers. Specificity was 89% (17 of 19; 95% CI: 67%, 99% ) for reader 1 and 79% (15 of 19; 95% CI: 54%, 94%) for reader 2, with near-perfect agreement between the readers (κ = 0.87; range, 0.70-1.00) in the 31 patients who underwent aspiration. CONCLUSION Initial retrospective assessment suggests that dual-energy CT is a sensitive, noninvasive, and reproducible method for identifying uric acid deposits in joints and periarticular soft tissues in patients suspected of having gout.


Medical Physics | 2009

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

Thomas Flohr; Shuai Leng; Lifeng Yu; Thomas Allmendinger; Herbert Bruder; Martin Petersilka; Christian Eusemann; Karl Stierstorfer; Bernhard Schmidt; Cynthia H. McCollough

PURPOSE To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. METHODS With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans atpitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. RESULTS No significant differences in quantitative measures of image quality were found between single-source scans atpitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6≤pitch≤3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). CONCLUSIONS A high-pitch (up topitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.


Physics in Medicine and Biology | 2004

Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data

Tingliang Zhuang; Shuai Leng; Brian E. Nett; Guang-Hong Chen

In this paper, a new image reconstruction scheme is presented based on Tuys cone-beam inversion scheme and its fan-beam counterpart. It is demonstrated that Tuys inversion scheme may be used to derive a new framework for fanbeam and cone-beam image reconstruction. In this new framework, images are reconstructed via filtering the backprojection image of differentiated projection data. The new framework is mathematically exact and is applicable to a general source trajectory provided the Tuy data sufficiency condition is satisfied. By choosing a piece-wise constant function for one of the components in the factorized weighting function, the filtering kernel is one dimensional, viz. the filtering process is along a straight line. Thus, the derived image reconstruction algorithm is mathematically exact and efficient. In the cone-beam case, the derived reconstruction algorithm is applicable to a large class of source trajectories where the pi-lines or the generalized pi-lines exist. In addition, the new reconstruction scheme survives the super-short scan mode in both the fan-beam and cone-beam cases provided the data are not transversely truncated. Numerical simulations were conducted to validate the new reconstruction scheme for the fan-beam case.


American Journal of Roentgenology | 2011

Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: An ex vivo phantom study

Mingliang Qu; Juan Carlos Ramirez-Giraldo; Shuai Leng; James C. Williams; Terri J. Vrtiska; John C. Lieske; Cynthia H. McCollough

OBJECTIVE The purpose of this study was to determine the ex vivo ability of dual-energy dual-source CT (DSCT) with additional tin filtration to differentiate among five groups of human renal stone types. MATERIALS AND METHODS Forty-three renal stones of 10 types were categorized into five primary groups on the basis of effective atomic numbers, which were calculated as the weighted average of the atomic numbers of constituent atoms. Stones were embedded in porcine kidneys and placed in a 35-cm water phantom. Dual-energy DSCT scans were performed at 80 and 140 kV with and without tin filtration of the 140-kV beam. The CT number ratio, defined as the ratio of the CT number of a given material in the low-energy image to the CT number of the same material in the high-energy image, was calculated on a volumetric voxel-by-voxel basis for each stone. Statistical analysis was performed, and receiver operating characteristic (ROC) curves were plotted to compare the difference in CT number ratio with and without tin filtration, and to measure the discrimination among stone groups. RESULTS The CT number ratio of non-uric acid stones increased on average by 0.17 (range, 0.03-0.36) with tin filtration. The CT number ratios for non-uric acid stone groups were not significantly different (p > 0.05) between any of the two adjacent groups without tin filtration. Use of the additional tin filtration on the high-energy x-ray tube significantly improved the separation of non-uric acid stone types by CT number ratio (p < 0.05). The area under the ROC curve increased from 0.78 to 0.84 without fin filtration and to 0.89-0.95 with tin filtration. CONCLUSION Our results showed better separation among different stone types when additional tin filtration was used on dual-energy DSCT. The increased spectral separation allowed a five-group stone classification scheme. Some overlapping between particular stone types still exists, including brushite and calcium oxalate.


Annals of the Rheumatic Diseases | 2015

Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study

Tim Bongartz; Katrina N. Glazebrook; Steven J. Kavros; Naveen S. Murthy; Stephen P. Merry; Walter B. Franz; Clement J. Michet; Barath M Akkara Veetil; John M. Davis; Thomas Mason; Kenneth J. Warrington; Steven R. Ytterberg; Eric L. Matteson; Cynthia S. Crowson; Shuai Leng; Cynthia H. McCollough

Objectives To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). Methods Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. Results The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). Conclusions DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals.


Medical Physics | 2013

Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.

Lifeng Yu; Shuai Leng; L Chen; James M. Kofler; Rickey E. Carter; Cynthia H. McCollough

PURPOSE Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. METHODS A 35 × 26 cm(2) torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was -15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. RESULTS The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The Pearsons product-moment correlation coefficients were 0.986 [95% confidence interval (CI): 0.958-0.996] for FBP and 0.985 (95% CI: 0.863-0.998) for IR. Bland-Altman plots showed excellent agreement for all dose levels and lesions sizes with a mean absolute difference of 1.0% ± 1.1% for FBP and 2.1% ± 3.3% for IR. CONCLUSIONS Human observer performance on a 2AFC lesion detection task in CT with a uniform background can be accurately predicted by a CHO model observer at different radiation dose levels and for both FBP and IR methods.

Collaboration


Dive into the Shuai Leng's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Brian E. Nett

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Guang-Hong Chen

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge