Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Shufang Meng is active.

Publication


Featured researches published by Shufang Meng.


Journal of Clinical Microbiology | 2003

Measurement of Human Cytomegalovirus Loads by Quantitative Real-Time PCR for Monitoring Clinical Intervention in Transplant Recipients

Haijing Li; J. Stephen Dummer; Wray R. Estes; Shufang Meng; Peter F. Wright; Yi-Wei Tang

ABSTRACT Quantitative monitoring of human cytomegalovirus (HCMV) infection is helpful in determining appropriate antiviral management of transplant recipients. Quantitative PCR technologies have demonstrated accuracy in measuring systemic HCMV loads. A total of 298 consecutive whole-blood specimens submitted to the Clinical Virology Laboratory at Vanderbilt University Medical Center from 15 February to 31 October 1999 were included in the study. In addition to a qualitative colorimetric microtiter plate PCR assay (MTP-PCR) and a semiquantitative pp65 antigenemia assay, each specimen was measured for HCMV loads by a quantitative PCR assay performed on an ABI PRISM 7700 Sequence Detection System (TaqMan). Compared to results of the MTP-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value were 70.5, 97.5, 87.8, and 92.8% for the antigenemia assay and were 96.7, 92.0, 75.6, and 99.1% for the TaqMan assay, respectively. There was a high correlation between antigenemia values and HCMV loads as determined by the TaqMan (r = 0.989; P < 0.001). Antigenemia values of 0, 1 to 10, 11 to 100, 101 to 1,000, and over 1,000 positive cells per 2 × 105 leukocytes corresponded to median HCMV loads measured by TaqMan of 125, 1,593, 5,713, 16,825, and 5,425,000 copies/ml, respectively. Corresponding to antigenemia values of 1 to 2, 10, and 50 positive cells per 2 × 105 leukocytes, HCMV viral loads of 1,000, 4,000, and 10,000 copies/ml are proposed as cutoff points for initiating antiviral therapy in patient groups with high, intermediate, and low risk of CMV diseases.


Journal of Clinical Microbiology | 2010

Detection and Identification of Ehrlichia Species in Blood by Use of PCR and Electrospray Ionization Mass Spectrometry

Mark W. Eshoo; Chris D. Crowder; Haijing Li; Heather Matthews; Shufang Meng; Susan E. Sefers; Rangarajan Sampath; Charles W. Stratton; Lawrence B. Blyn; David J. Ecker; Yi-Wei Tang

ABSTRACT Rapid detection and identification of Ehrlichia species improves clinical outcome for patients suspected of ehrlichiosis. We describe an assay that employs multilocus PCR and electrospray ionization mass spectrometry (PCR/ESI-MS) to detect and identify Ehrlichia species directly from blood specimens. The results were compared to those of a colorimetric microtiter PCR enzyme immunoassay (PCR-EIA) used as a diagnostic assay. Among 213 whole-blood samples collected from patients who were clinically suspected of ehrlichiosis from 1 May to 1 August 2008 at Vanderbilt University Hospital, 40 were positive for an Ehrlichia species by PCR/ESI-MS, giving a positive rate of 18.8%. In comparison to the PCR-EIA, PCR/ESI-MS possessed a sensitivity, a specificity, and positive and negative predictive values of 95.0%, 98.8%, 95.0%, and 98.8%, respectively. The 38 specimens that were positive for Ehrlichia by both PCR/ESI-MS and the PCR-EIA were further characterized to the species level, with 100% agreement between the two assays. In addition, Rickettsia rickettsii was detected by PCR/ESI-MS from four specimens that were confirmed retrospectively by serology and PCR-EIA. In three specimens, the PCR/ESI-MS assay identified Pseudomonas aeruginosa, Neisseria meningitidis, and Staphylococcus aureus; these were confirmed by culture and/or clinical diagnosis as being clinically relevant. From specimen processing to result reporting, the PCR/ESI-MS assay can be completed within 6 h, providing another laboratory tool for the diagnosis of ehrlichiosis. Moreover, this system may provide rapid detection and identification of additional pathogens directly from blood specimens.


Journal of Clinical Microbiology | 2008

Prospective Evaluation of Rapid Antigen Tests for Diagnosis of Respiratory Syncytial Virus and Human Metapneumovirus Infections

Jaber Aslanzadeh; Xiaotian Zheng; Haijing Li; Janice Tetreault; Irene Ratkiewicz; Shufang Meng; Pamela Hamilton; Yi-Wei Tang

ABSTRACT Respiratory syncytial virus (RSV) and human metapneumovirus (hMPV) are two important viral pathogens that cause respiratory tract infections in the pediatric population. The rapid detection of these agents allows the prompt isolation and treatment of infected patients. In the present prospective study, we evaluated the performances of four rapid antigen detection assays, including a rapid chromatographic immunoassay (CIA) for RSV (Directigen EZ RSV; Becton Dickinson, Sparks, MD), a direct fluorescent-antibody assay (DFA) for RSV (Bartels; Trinity Biotech, Carlsbad, CA), and two DFAs for hMPV manufactured by Diagnostic Hybrids Inc. (DHI; Athens, OH) and Imagen (Oxoid Ltd., Basingstoke, Hampshire, United Kingdom). The clinical specimens tested comprised 515 nasopharyngeal aspirates submitted to the Clinical Microbiology Laboratory at Hartford Hospital from 1 November 2006 to 21 April 2007. Compared to the results of real-time reverse transcription-PCR (RT-PCR), the CIA had a sensitivity of 79.8% and a specificity of 89.5%. The RSV DFA with Bartels reagents showed a sensitivity of 94.1% and a specificity of 96.8%. For hMPV, the sensitivity and specificity were 62.5% and 99.8%, respectively, for the DHI DFA and 63.2% and 100%, respectively, for the Imagen DFA. The hands-on and test turnaround times for CIA were 10 and 30 to 60 min, respectively, and the hands-on and test turnaround times for the RSV and hMPV DFAs were 30 and 105 min, respectively. We conclude that while the RSV CIA is user-friendly, it lacks sensitivity and specificity, especially during off-peak months. In contrast, the RSV DFA is more sensitive and specific, but interpretation of its results is subjective and it demands technical time and expertise. Similarly, both hMPV DFAs are highly specific in comparison to the results of RT-PCR, but their sensitivities await further improvements.


Journal of Clinical Microbiology | 2013

Detection, Identification, and Distribution of Fungi in Bronchoalveolar Lavage Specimens by Use of Multilocus PCR Coupled with Electrospray Ionization/Mass Spectrometry

Jeong Hwan Shin; Raymond Ranken; Susan E. Sefers; Robert Lovari; Criziel D. Quinn; Shufang Meng; Heather E. Carolan; Donna Toleno; Haijing Li; Jeong Nyeo Lee; Charles W. Stratton; Christian Massire; Yi-Wei Tang

ABSTRACT As pulmonary fungal infections continue to increase due to an increasing number of immunocompromised patients, rapid detection and accurate identification of these fungal pathogens are critical. A broad fungal assay was developed by incorporating broad-range multilocus PCR amplification and electrospray ionization/mass spectrometry (PCR/ESI-MS) to detect and identify fungal organisms directly from clinical specimens. The aims of this study were to evaluate the performance of PCR/ESI-MS for detection, identification, and determination of the distribution of fungal organisms in bronchoalveolar lavage (BAL) fluid specimens. The BAL fluid specimens submitted for fungal culture at Vanderbilt University Medical Center between May 2005 and October 2011 were included. Cultures and identification were done using standard procedures. In addition, DNA was extracted from BAL fluid specimens, and fungal DNA amplification/identification were performed by PCR/ESI-MS. The results were compared with those of the standard cultures. A total of 691 nonduplicated BAL fluid specimens with sufficient leftover volume for molecular testing were evaluated using PCR/ESI-MS. Among them, 134 specimens (19.4%) were positive for fungi by both culture and PCR/ESI-MS testing. Of the dual-positive specimens, 125 (93.3%) were positive for Candida and Aspergillus species, with concordances between culture and PCR/ESI-MS results being 84 (67.2%) at the species level and 109 (87.2%) at the genus level. In addition, 243 (35.2%) and 30 (4.3%) specimens were positive only by PCR/ESI-MS or by culture, respectively (odds ratio [OR] = 11.95, 95% confidence interval [CI] = 7.90 to 18.17, P = 0.0000). Codetection of fungal organisms was noted in 23 (3.3%) specimens by PCR/ESI-MS, which was significantly higher than the 4 (0.6%) in which they were noted by culture (OR = 5.91, 95% CI = 1.93 to 20.27, P = 0.0002). Among 53 specimens in which cultures failed because of bacterial overgrowth, at least one fungus was identified in 26 specimens (47.3%) by PCR/ESI-MS. PCR/ESI-MS provides an advanced tool for rapid and sensitive detection, identification, and determination of the distribution of fungal organisms directly from BAL fluid specimens. Moreover, it detected fungal organisms in specimens in which cultures failed because of bacterial overgrowth. The clinical relevance of the significantly higher detection rate of fungal organisms by PCR/ESI-MS merits further investigation.


Gut microbes | 2014

Early life establishment of site-specific microbial communities in the gut

Joann Romano-Keeler; Daniel J. Moore; Chunlin Wang; Robert M. Brucker; Christopher Fonnesbeck; James C. Slaughter; Haijing Li; Danielle P Curran; Shufang Meng; Hernan Correa; Harold N. Lovvorn; Yi-Wei Tang; Seth R. Bordenstein; Alfred L. George; Jörn-Hendrik Weitkamp

Fecal sampling is widely utilized to define small intestinal tissue-level microbial communities in healthy and diseased newborns. However, this approach may lead to inaccurate assessments of disease or therapeutics in newborns because of the assumption that the taxa in the fecal microbiota are representative of the taxa present throughout the gastrointestinal tract. To assess the stratification of microbes in the newborn gut and to evaluate the probable shortcoming of fecal sampling in place of tissue sampling, we simultaneously compared intestinal mucosa and fecal microbial communities in 15 neonates undergoing intestinal resections. We report three key results. First, when the site of fecal and mucosal samples are further apart, their microbial communities are more distinct, as indicated by low mean Sørensen similarity indices for each patients fecal and tissue microbiota. Second, two distinct niches (intestinal mucosa and fecal microbiota) are evident by principal component analyses, demonstrating the critical role of sample source in defining microbial composition. Finally, in contrast to adult studies, intestinal bacterial diversity was higher in tissue than in fecal samples. This study represents an unprecedented map of the infant microbiota from intestinal mucosa and establishes discernable biogeography throughout the neonatal gastrointestinal tract. Our results question the reliance on fecal microbiota as a proxy for the developing intestinal microbiota. Additionally, the robust intestinal tissue-level bacterial diversity we detected at these early ages may contribute to the maturation of mucosal immunity.


Journal of Clinical Microbiology | 2011

Molecular Characterization of Drug Resistant Mycobacterium tuberculosis Isolates Circulating in China by Multilocus PCR and Electrospray Ionization Mass Spectrometry

Feifei Wang; Christian Massire; Haijing Li; Lendell L. Cummins; Feng Li; Jialin Jin; Xiaoping Fan; Sen Wang; Lingyun Shao; Shu Zhang; Shufang Meng; Jing Wu; Chanyi Lu; Lawrence B. Blyn; Rangarajan Sampath; David J. Ecker; Wenhong Zhang; Yue Tang

ABSTRACT We used multilocus PCR and electrospray ionization mass spectrometry (PCR/ESI-MS) to determine the genotype and drug resistance profiles for 96 Mycobacterium tuberculosis isolates circulating in regions of high and low tuberculosis (TB) endemicity in China. The dominant principal genetic group (PGG) circulating in China was PGG1, and drug-resistant gene mutations were more diversified in the region of low rather than high TB endemicity.


PLOS ONE | 2009

Qualitative and Quantitative Detection of Chlamydophila pneumoniae DNA in Cerebrospinal Fluid from Multiple Sclerosis Patients and Controls

Yi-Wei Tang; Subramaniam Sriram; Haijing Li; Song-Yi Yao; Shufang Meng; William M. Mitchell; Charles W. Stratton

A standardized molecular test for the detection of Chlamydophila pneumoniae DNA in cerebrospinal fluid (CSF) would assist the further assessment of the association of C. pneumoniae with multiple sclerosis (MS). We developed and validated a qualitative colorimetric microtiter plate-based PCR assay (PCR-EIA) and a real-time quantitative PCR assay (TaqMan) for detection of C. pneumoniae DNA in CSF specimens from MS patients and controls. Compared to a touchdown nested-PCR assay, the sensitivity, specificity, and concordance of the PCR-EIA assay were 88.5%, 93.2%, and 90.5%, respectively, on a total of 137 CSF specimens. PCR-EIA presented a significantly higher sensitivity in MS patients (p = 0.008) and a higher specificity in other neurological diseases (p = 0.018). Test reproducibility of the PCR-EIA assay was statistically related to the volumes of extract DNA included in the test (p = 0.033); a high volume, which was equivalent to 100 µl of CSF per reaction, yielded a concordance of 96.8% between two medical technologists running the test at different times. The TaqMan quantitative PCR assay detected 26 of 63 (41.3%) of positive CSF specimens that tested positive by both PCR-EIA and nested-PCR qualitative assays. None of the CSF specimens that were negative by the two qualitative PCR methods were detected by the TaqMan quantitative PCR. The PCR-EIA assay detected a minimum of 25 copies/ml C. pneumoniae DNA in plasmid-spiked CSF, which was at least 10 times more sensitive than TaqMan. These data indicated that the PCR-EIA assay possessed a sensitivity that was equal to the nested-PCR procedures for the detection of C. pneumoniae DNA in CSF. The TaqMan system may not be sensitive enough for diagnostic purposes due to the low C. pneumoniae copies existing in the majority of CSF specimens from MS patients.


Journal of Clinical Microbiology | 2011

Comparative Evaluation of Bruker Biotyper and BD Phoenix Systems for Identification of Bacterial Pathogens Associated with Urinary Tract Infections

Yingjun Yan; Shufang Meng; Dongmo Bian; Criziel D. Quinn; Haijing Li; Charles W. Stratton; Yue Tang

ABSTRACT The Bruker Biotyper and BD Phoenix systems were evaluated for identification of 1,024 bacterial urinary tract isolates. The Biotyper and Phoenix systems correctly identified 99.9% and 99.5% to the genus level and 99.1% and 98.5% to the species level, respectively. Both systems provide reliable results, and the Biotyper system offers a rapid tool for urine bacterial isolate identification.


Journal of Perinatology | 2017

Oral colostrum priming shortens hospitalization without changing the immunomicrobial milieu

Joann Romano-Keeler; M. A. Azcarate-Peril; Jörn-Hendrik Weitkamp; James C. Slaughter; W. H. McDonald; Shufang Meng; M. S. Latuga; James L. Wynn

Objective:Oral colostrum priming (OCP) after birth in preterm infants is associated with improved weight gain and modification of the oral immunomicrobial environment. We hypothesized that OCP would modify salivary immune peptides and the oral microbiota in preterm infants.Study design:We conducted a prospective, randomized clinical trial to determine the effects of OCP on salivary immune peptide representation in preterm infants (<32 weeks completed gestation at birth). Saliva samples were collected before and after OCP. Salivary immune peptide representation was determined via mass spectroscopy. Oral microbiota representation was determined via sequencing of the 16S rRNA gene.Results:Neonates who received OCP (n=48) had a 16-day reduction in the median length of hospitalization as compared with infants who did not receive OCP (n=51). No differences in salivary immune peptide sequence representation before OCP between groups were found. Longitudinal changes in peptides were detected (lysozyme C, immunoglobulin A, lactoferrin) but were limited to a single peptide difference (α-defensin 1) between primed and unprimed infants after OCP. We found no difference in microbial diversity between treatment groups at any time point, but diversity decreased significantly over time in both groups. OCP treatment marginally modified oral taxa with a decline in abundance of Streptococci in the OCP group at 30 days of life.Conclusions:OCP had neither an effect on the salivary peptides we examined nor on overall oral bacterial diversity and composition. Infants who received OCP had a reduced length of hospitalization and warrants further investigation.


Journal of Clinical Virology | 2009

Sensitive, qualitative detection of human herpesvirus-6 and simultaneous differentiation of variants A and B

Haijing Li; Shufang Meng; Susan M. Levine; Charles W. Stratton; Yi-Wei Tang

BACKGROUND The current limitations of laboratory testing for the detection of human herpesvirus virus 6 (HHV-6) in clinical specimens with low HHV-6 viral loads make this area a priority for further research and development. OBJECTIVES To develop and validate a sensitive qualitative assay for simultaneous HHV-6 detection and variant differentiation. METHODS We developed a diagnostic procedure, which combines a magnetic bead-based nucleic acid extraction, PCR amplification, and colorimetric microtiter plate identification (MAG-PCR-EIA), for the sensitive detection of HHV-6 and the simultaneous differentiation of HHV-6A and HHV-6B. RESULTS Analytic sensitivities of the MAG-PCR-EIA assay were 10 copies per reaction for both HHV-6A and HHV-6B variants, which is equivalent to 20 copies/ml when 1ml of clinical specimen was processed. A proficiency panel containing 11 blinded specimens covering HHV-6A viral loads from 0 to 100,000 copies was tested, and the MAG-PCR-EIA was able to detect the lowest concentration at one copy in 200microl. A panel of 27 urine specimens, which were collected from patients with and without chronic fatigue syndrome, was tested by the MAG-PCR-EIA. HHV-6 was detected in two (HHV-6A) patients who have chromosomally integrated HHV-6A and in one (HHV-6B) patient who was a healthy control and diagnosed as cervical cancer later on. The HHV-6 results did not correlate with results previously determined by HHV-6 antigenemia in urine. CONCLUSION With large specimen volumes processed and an additional signal amplification incorporated, the MAG-PCR-EIA provides a sensitive and qualitative system for HHV-6 detection and simultaneous variant differentiation. Clinical relevance of the assay awaits further investigation.

Collaboration


Dive into the Shufang Meng's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Charles W. Stratton

Vanderbilt University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alan S. Boyd

Vanderbilt University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Criziel D. Quinn

Vanderbilt University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge