Sudkate Chaiyo
Chulalongkorn University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sudkate Chaiyo.
Analytica Chimica Acta | 2016
Sudkate Chaiyo; Eda Mehmeti; Kristina Žagar; Weena Siangproh; Orawon Chailapakul; Kurt Kalcher
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L(-1). With an accumulation period of 120 s detection limits of 0.09 ng mL(-1), 0.06 ng L(-1) and 0.08 ng L(-1) were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry.
Analytica Chimica Acta | 2015
Sudkate Chaiyo; Weena Siangproh; Amara Apilux; Orawon Chailapakul
A novel, highly selective and sensitive paper-based colorimetric sensor for trace determination of copper (Cu(2+)) ions was developed. The measurement is based on the catalytic etching of silver nanoplates (AgNPls) by thiosulfate (S2O3(2-)). Upon the addition of Cu(2+) to the ammonium buffer at pH 11, the absorption peak intensity of AuNPls/S2O3(2-) at 522 nm decreased and the pinkish violet AuNPls became clear in color as visible to the naked eye. This assay provides highly sensitive and selective detection of Cu(2+) over other metal ions (K(+), Cr(3+), Cd(2+), Zn(2+), As(3+), Mn(2+), Co(2+), Pb(2+), Al(3+), Ni(2+), Fe(3+), Mg(2+), Hg(2+) and Bi(3+)). A paper-based colorimetric sensor was then developed for the simple and rapid determination of Cu(2+) using the catalytic etching of AgNPls. Under optimized conditions, the modified AgNPls coated at the test zone of the devices immediately changes in color in the presence of Cu(2+). The limit of detection (LOD) was found to be 1.0 ng mL(-1) by visual detection. For semi-quantitative measurement with image processing, the method detected Cu(2+) in the range of 0.5-200 ng mL(-1)(R(2)=0.9974) with an LOD of 0.3 ng mL(-1). The proposed method was successfully applied to detect Cu(2+) in the wide range of real samples including water, food, and blood. The results were in good agreement according to a paired t-test with results from inductively coupled plasma-optical emission spectrometry (ICP-OES).
Biosensors and Bioelectronics | 2018
Sudkate Chaiyo; Eda Mehmeti; Weena Siangproh; Thai Long Hoang; Hai Phong Nguyen; Orawon Chailapakul; Kurt Kalcher
We introduce for the first time a paper-based analytical device (PAD) for the non-enzymatic detection of glucose by modifying a screen-printed carbon electrode with cobalt phthalocyanine, graphene and an ionic liquid (CoPc/G/IL/SPCE). The modifying composite was characterized by UV-visible spectroscopy, energy dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The disposable devices show excellent conductivity and fast electron transfer kinetics. The results demonstrated that the modified electrode on PADs had excellent electrocatalytic activity towards the oxidation of glucose with NaOH as supporting electrolyte (0.1M). The oxidation potential of glucose was negatively shifted to 0.64V vs. the screen-printed carbon pseudo-reference electrode. The paper-based sensor comprised a wide linear concentration range for glucose, from 0.01 to 1.3mM and 1.3-5.0mM for low and high concentration of glucose assay, respectively, with a detection limit of 0.67µM (S/N = 3). Additionally, the PADs were applied to quantify glucose in honey, white wine and human serum. The disposable, efficient, sensitive and low-cost non-enzymatic PAD has great potential for the development of point-of-care testing (POCT) devices that can be applied in healthcare monitoring.
Analytica Chimica Acta | 2018
Kanokwan Charoenkitamorn; Sudkate Chaiyo; Orawon Chailapakul; Weena Siangproh
In this work, for the first time, manganese (IV) oxide-modified screen-printed graphene electrodes (MnO2/SPGEs) were developed for the simultaneous electrochemical detection of coenzyme Q10 (CoQ10) and α-lipoic acid (ALA). This sensor exhibits attractive benefits such as simplicity, low production costs, and disposability. Cyclic voltammetry (CV) was used to characterize the electrochemical behavior of the analyte and investigate the capacitance and electroactive surface area of the unmodified and modified electrode surfaces. The electrochemical behavior of CoQ10 and ALA on MnO2/SPGEs was also discussed. Additionally, square wave anodic stripping voltammetry (SWASV) was used for the quantitative determination of CoQ10 and ALA. Under optimal conditions, the obtained signals are linear in the concentration range from 2.0 to 75.0 μg mL-1 for CoQ10 and 0.3-25.0 μg mL-1 for ALA. The low limits of detection (LODs) were found to be 0.56 μg mL-1 and 0.088 μg mL-1 for CoQ10 and ALA, respectively. Moreover, we demonstrated the utility and applicability of the MnO2/SPGE sensor through simultaneous measurements of CoQ10 and ALA in dietary supplements. The sensor provides high accuracy measurements, exhibiting its high potential for practical applications.
Sensors and Actuators B-chemical | 2016
Sudkate Chaiyo; Amara Apiluk; Weena Siangproh; Orawon Chailapakul
Mikrochimica Acta | 2016
Eda Mehmeti; Dalibor M. Stanković; Sudkate Chaiyo; Ľubomír Švorc; Kurt Kalcher
Mikrochimica Acta | 2017
Eda Mehmeti; Dalibor M. Stanković; Sudkate Chaiyo; Janez Zavašnik; Kristina Žagar; Kurt Kalcher
Journal of Applied Polymer Science | 2018
Pongpol Ekabutr; Teeraseth Ariyathanakul; Sudkate Chaiyo; Pimolpun Niamlang; Santi Rattanaveeranon; Orawon Chailapakul; Pitt Supaphol
Monatshefte Fur Chemie | 2016
Eda Mehmeti; Dalibor M. Stanković; Sudkate Chaiyo; Ľubomír Švorc; Astrid Ortner; Kurt Kalcher
Mikrochimica Acta | 2018
Kingkan Pungjunun; Sudkate Chaiyo; Issarapong Jantrahong; Siriwan Nantaphol; Weena Siangproh; Orawon Chailapakul