Weena Siangproh
Srinakharinwirot University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Weena Siangproh.
Analytical Chemistry | 2010
Amara Apilux; Wijitar Dungchai; Weena Siangproh; Narong Praphairaksit; Charles S. Henry; Orawon Chailapakul
A novel lab-on-paper device combining electrochemical and colorimetric detection for the rapid screening of Au(III) in the presence of a common interference, Fe(III), in industrial waste solutions is presented here. With dilute aqua regia (0.1 M HCl + 0.05 M HNO(3)) as the supporting electrolyte, square wave voltammetry on paper provided a well-defined reduction peak for Au(III) at approximately 287 +/- 12 mV vs Ag/AgCl. Under the optimized working conditions, the calibration curve showed good linearity in the concentration range of 1-200 ppm of Au(III) with a correlation coefficient of 0.997. The limit of detection (LOD) of the proposed method is 1 ppm. Interferences from various cations were also studied. Fe(III) is the only metal that affects the electrochemical determination of Au(III) when present above a 2.5-fold excess concentration of that of the Au(III). To overcome this limitation, a colorimetric method was used to simultaneously detect Fe(III) as a screening tool. The procedure was then successfully applied to determine Au(III) in gold-refining waste solutions. The results are in agreement with those obtained from inductively coupled plasma-atomic emission spectrometry (ICP-AES).
Analytica Chimica Acta | 2010
Uthaitip Injang; Peeyanun Noyrod; Weena Siangproh; Wijitar Dungchai; Shoji Motomizu; Orawon Chailapakul
A method for the simultaneous determination of Pb(II), Cd(II), and Zn(II) at low microg L(-1) concentration levels by sequential injection analysis-anodic stripping voltammetry (SIA-ASV) using screen-printed carbon nanotubes electrodes (SPCNTE) was developed. A bismuth film was prepared by in situ plating of bismuth on the screen-printed carbon nanotubes electrode. Operational parameters such as ratio of carbon nanotubes to carbon ink, bismuth concentration, deposition time and flow rate during preconcentration step were optimized. Under the optimal conditions, the linear ranges were found to be 2-100 microg L(-1) for Pb(II) and Cd(II), and 12-100 microg L(-1) for Zn(II). The limits of detection (S(bl)/S=3) were 0.2 microg L(-1) for Pb(II), 0.8 microg L(-1) for Cd(II) and 11 microg L(-1) for Zn(II). The measurement frequency was found to be 10-15 stripping cycle h(-1). The present method offers high sensitivity and high throughput for on-line monitoring of trace heavy metals. The practical utility of our method was also demonstrated with the determination of Pb(II), Cd(II), and Zn(II) by spiking procedure in herb samples. Our methodology produced results that were correlated with ICP-AES data. Therefore, we propose a method that can be used for the automatic and sensitive evaluation of heavy metals contaminated in herb items.
Food Chemistry | 2008
Orawon Chailapakul; Wanida Wonsawat; Weena Siangproh; Kate Grudpan; Yifang Zhao; Zhiwei Zhu
A method was developed for analyzing of sudan I, sudan II, sudan III, and sudan IV by high performance liquid chromatography coupled with an electrochemical detector. The electrochemical oxidation of each compound was investigated with a carbon nanotube-ionic liquid gel modified glassy carbon (MWNTs-IL-Gel/GC) electrode using cyclic voltammetry. The results were compared with those of glassy carbon electrodes. At the MWNTs-IL-Gel/GC electrode, highly reproducible, well-defined cyclic voltammograms for sudan oxidation were obtained. In the flow system, MWNTs-IL-Gel/GC exhibited highly reproducible and well-defined amperometric signals without peak tailing. In addition, the determination of sudan dyes by mean of isocratic reverse-phase HPLC, with amperometric detection at MWNTs-IL-Gel/GC and GC electrode, have been investigated. The chromatograms showed excellent separation. The detection limits ranged from 0.001 to 0.005ppm. The method was sensitive, selective and could be applicable for the assay of sudan dyes in soft drink samples.
Analytica Chimica Acta | 2011
Weena Siangproh; Wijitar Dungchai; Poomrat Rattanarat; Orawon Chailapakul
With recent advances in nanotechnology making more easily available the novel chemical and physical properties of metal nanoparticles (NPs), these have become extremely suitable for creating new sensing assays. Many kinds of NPs, including metal, metal-oxide, semiconductor and even composite-metal NPs, have been used for constructing electrochemical sensors. This article reviews the progress of NP-based electrochemical detection in recent applications, especially in bioanalysis, and summarizes the main functions of NPs in conventional and miniaturized systems. All references cited here generally show one or more of the following characteristics: a low detection limit, good signal amplification and simultaneous-detection capabilities.
Talanta | 2012
Amara Apilux; Weena Siangproh; Narong Praphairaksit; Orawon Chailapakul
This work combines lab-on-paper methodology with nanoparticle science to develop a new tool for the simple and rapid determination of Hg(II). The resulting paper-based device enables measurement of Hg(II) from only 2 μL of sample solution. The color of the nanosilver in the test area immediately changes in the presence of Hg(II), and this change can be monitored by the naked eye. This method exhibits superior selectivity towards Hg(II) compared with the other metal ions tested. Furthermore, the results show a significant increase in the Hg(II) analytical signal when Cu(II) is added to the Ag Nanoplates at the test zone. With digital camera imaging and software processing, which are shown to further improve the quantitative capability of this technique, the linear detection range is 5-75 ppm Hg(II) with a limit of detection of 0.12 ppm. Using a pre-concentration scheme (based on repeated 2 μL applications of the test Hg(II) solution onto the same test zone) reduces the limit of detection to 2 ppb. The technique developed by this study provides a rapid, sensitive and selective detection method for aqueous Hg(II) samples and is especially suitable for remote field and environmental analysis.
Biosensors and Bioelectronics | 2012
Pattarachaya Preechakasedkit; Kulwadee Pinwattana; Wijitar Dungchai; Weena Siangproh; Wanpen Chaicumpa; Pongsri Tongtawe; Orawon Chailapakul
An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi O901 and antibody of S. typhi O901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi O901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14×10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88×10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi.
Biosensors and Bioelectronics | 2014
Sakda Jampasa; Wanida Wonsawat; Nadnudda Rodthongkum; Weena Siangproh; Pattamawadee Yanatatsaneejit; Tirayut Vilaivan; Orawon Chailapakul
An electrochemical biosensor based on an immobilized anthraquinone-labeled pyrrolidinyl peptide nucleic acid (acpcPNA) probe was successfully developed for the selective detection of human papillomavirus (HPV) type 16 DNA. A 14-mer acpcPNA capture probe was designed to recognize a specific 14 nucleotide region of HPV type 16 L1 gene. The redox-active label anthraquinone (AQ) was covalently attached to the N-terminus of the acpcPNA probe through an amide bond. The probe was immobilized onto a chitosan-modified disposable screen-printed carbon electrode via a C-terminal lysine residue using glutaraldehyde as a cross-linking agent. Hybridization with the target DNA was studied by measuring the electrochemical signal response of the AQ label using square-wave voltammetric analysis. The calibration curve exhibited a linear range between 0.02 and 12.0 µM with a limit of detection and limit of quantitation of 4 and 14 nM, respectively. This DNA sensing platform was successfully applied to detect the HPV type 16 DNA from a PCR amplified (240 bp fragment of the L1 gene) sample derived from the HPV type 16 positive human cancer cell line (SiHa), and failed to detect the HPV-negative c33a cell line. The sensor probe exhibited very high selectivity for the complementary 14 base oligonucleotide over the non-complementary oligonucleotides with sequences derived from HPV types 18, 31 and 33. The proposed sensor provides an inexpensive tool for the early stage detection of HPV type 16, which is an important biomarker for cervical cancer.
Analytica Chimica Acta | 2016
Sudkate Chaiyo; Eda Mehmeti; Kristina Žagar; Weena Siangproh; Orawon Chailapakul; Kurt Kalcher
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L(-1). With an accumulation period of 120 s detection limits of 0.09 ng mL(-1), 0.06 ng L(-1) and 0.08 ng L(-1) were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry.
Analytica Chimica Acta | 2012
Poomrat Rattanarat; Wijitar Dungchai; Weena Siangproh; Orawon Chailapakul; Charles S. Henry
We report the development of an electrochemical paper-based analytical device (ePAD) for the selective determination of dopamine (DA) in model serum sample. The ePAD device consists of three layers. In the top layer, SU-8 photoresist defines a hydrophilic sample application spot on the filter paper. The middle layer was made from transparency film and contained two holes, one for sample preconcentration and the other for the surfactant to allow transfer to the third layer. A screen-printed carbon electrode formed the bottom layer and was used for electrochemical measurements. In the absence of the anionic surfactant, sodium dodecyl sulfate (SDS), the oxidation peaks of DA, ascorbic acid (AA) and uric acid (UA) overlapped. With the addition of SDS, the DA oxidation peak shifted to more negative values and was clearly distinguishable from AA and UA. The oxidation potential shift was presumably due to preferential electrostatic interactions between the cationic DA and the anionic SDS. Indeed, whilst the SDS-modified paper improved the DA current five-fold, the non-ionic Tween-20 and cationic tetradecyltrimethylammonium bromide surfactants had no effect or reduced the current, respectively. Furthermore, only the SDS-modified paper showed the selective shift in oxidation potential for DA. DA determination was carried out using square-wave voltammetry between -0.2 and 0.8 V vs. Ag/AgCl, and this ePAD was able to detect DA over a linear range of 1-100 μM with a detection limit (S/N=3) of 0.37 μM. The ePAD seems suitable as a low cost, easy-to-use, portable device for the selective quantitation of DA in human serum samples.
Analytica Chimica Acta | 2015
Sudkate Chaiyo; Weena Siangproh; Amara Apilux; Orawon Chailapakul
A novel, highly selective and sensitive paper-based colorimetric sensor for trace determination of copper (Cu(2+)) ions was developed. The measurement is based on the catalytic etching of silver nanoplates (AgNPls) by thiosulfate (S2O3(2-)). Upon the addition of Cu(2+) to the ammonium buffer at pH 11, the absorption peak intensity of AuNPls/S2O3(2-) at 522 nm decreased and the pinkish violet AuNPls became clear in color as visible to the naked eye. This assay provides highly sensitive and selective detection of Cu(2+) over other metal ions (K(+), Cr(3+), Cd(2+), Zn(2+), As(3+), Mn(2+), Co(2+), Pb(2+), Al(3+), Ni(2+), Fe(3+), Mg(2+), Hg(2+) and Bi(3+)). A paper-based colorimetric sensor was then developed for the simple and rapid determination of Cu(2+) using the catalytic etching of AgNPls. Under optimized conditions, the modified AgNPls coated at the test zone of the devices immediately changes in color in the presence of Cu(2+). The limit of detection (LOD) was found to be 1.0 ng mL(-1) by visual detection. For semi-quantitative measurement with image processing, the method detected Cu(2+) in the range of 0.5-200 ng mL(-1)(R(2)=0.9974) with an LOD of 0.3 ng mL(-1). The proposed method was successfully applied to detect Cu(2+) in the wide range of real samples including water, food, and blood. The results were in good agreement according to a paired t-test with results from inductively coupled plasma-optical emission spectrometry (ICP-OES).