Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Swatee Singh is active.

Publication


Featured researches published by Swatee Singh.


Medical Physics | 2006

Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms

Georgia D. Tourassi; Brian P. Harrawood; Swatee Singh; Joseph Y. Lo; Carey E. Floyd

The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.


Medical Imaging 2005: Physics of Medical Imaging | 2005

Digital breast tomosynthesis using an amorphous selenium flat panel detector

M. Bissonnette; Marc Hansroul; E. Masson; Simon Savard; S. Cadieux; P. Warmoes; D. Gravel; J. Agopyan; B. Polischuk; W. Haerer; Thomas Mertelmeier; Joseph Y. Lo; Ying Chen; James T. Dobbins; Jonathan L. Jesneck; Swatee Singh

A prototype breast tomosynthesis system has been developed, allowing a total angular view of ±25°. The detector used in this system is an amorphous selenium direct-conversion digital flat-panel detector suitable for digital tomosynthesis. The system is equipped with various readout sequences to allow the investigation of different tomosynthetic data acquisition modes. In this paper, we will present basic physical properties -- such as MTF, NPS, and DQE -- measured for the full resolution mode and a binned readout mode of the detector. From the measured projections, slices are reconstructed employing a special version of filtered backprojection algorithm. In a phantom study, we compare binned and full resolution acquisition modes with respect to image quality. Under the condition of same dose, we investigate the impact of the number of views on artifacts. Finally, we show tomosynthesis images reconstructed from first clinical data.


Medical Physics | 2008

Automated breast mass detection in 3D reconstructed tomosynthesis volumes: A featureless approach

Swatee Singh; Georgia D. Tourassi; Jay A. Baker; Ehsan Samei; Joseph Y. Lo

The purpose of this study was to propose and implement a computer aided detection (CADe) tool for breast tomosynthesis. This task was accomplished in two stages-a highly sensitive mass detector followed by a false positive (FP) reduction stage. Breast tomosynthesis data from 100 human subject cases were used, of which 25 subjects had one or more mass lesions and the rest were normal. For stage 1, filter parameters were optimized via a grid search. The CADe identified suspicious locations were reconstructed to yield 3D CADe volumes of interest. The first stage yielded a maximum sensitivity of 93% with 7.7 FPs/breast volume. Unlike traditional CADe algorithms in which the second stage FP reduction is done via feature extraction and analysis, instead information theory principles were used with mutual information as a similarity metric. Three schemes were proposed, all using leave-one-case-out cross validation sampling. The three schemes, A, B, and C, differed in the composition of their knowledge base of regions of interest (ROIs). Scheme As knowledge base was comprised of all the mass and FP ROIs generated by the first stage of the algorithm. Scheme B had a knowledge base that contained information from mass ROIs and randomly extracted normal ROIs. Scheme C had information from three sources of information-masses, FPs, and normal ROIs. Also, performance was assessed as a function of the composition of the knowledge base in terms of the number of FP or normal ROIs needed by the system to reach optimal performance. The results indicated that the knowledge base needed no more than 20 times as many FPs and 30 times as many normal ROIs as masses to attain maximal performance. The best overall system performance was 85% sensitivity with 2.4 FPs per breast volume for scheme A, 3.6 FPs per breast volume for scheme B, and 3 FPs per breast volume for scheme C.


Medical Physics | 2007

Information-theoretic CAD system in mammography: entropy-based indexing for computational efficiency and robust performance.

Georgia D. Tourassi; Brian P. Harrawood; Swatee Singh; Joseph Y. Lo

We have previously presented a knowledge-based computer-assisted detection (KB-CADe) system for the detection of mammographic masses. The system is designed to compare a query mammographic region with mammographic templates of known ground truth. The templates are stored in an adaptive knowledge database. Image similarity is assessed with information theoretic measures (e.g., mutual information) derived directly from the image histograms. A previous study suggested that the diagnostic performance of the system steadily improves as the knowledge database is initially enriched with more templates. However, as the database increases in size, an exhaustive comparison of the query case with each stored template becomes computationally burdensome. Furthermore, blind storing of new templates may result in redundancies that do not necessarily improve diagnostic performance. To address these concerns we investigated an entropy-based indexing scheme for improving the speed of analysis and for satisfying database storage restrictions without compromising the overall diagnostic performance of our KB-CADe system. The indexing scheme was evaluated on two different datasets as (i) a search mechanism to sort through the knowledge database, and (ii) a selection mechanism to build a smaller, concise knowledge database that is easier to maintain but still effective. There were two important findings in the study. First, entropy-based indexing is an effective strategy to identify fast a subset of templates that are most relevant to a given query. Only this subset could be analyzed in more detail using mutual information for optimized decision making regarding the query. Second, a selective entropy-based deposit strategy may be preferable where only high entropy cases are maintained in the knowledge database. Overall, the proposed entropy-based indexing scheme was shown to reduce the computational cost of our KB-CADe system by 55% to 80% while maintaining the systems diagnostic performance.


Academic Radiology | 2008

EVALUATING THE EFFECT OF IMAGE PREPROCESSING ON AN INFORMATION-THEORETIC CAD SYSTEM IN MAMMOGRAPHY

Georgia D. Tourassi; Robert Ike; Swatee Singh; Brian P. Harrawood

RATIONALE AND OBJECTIVES In our earlier studies, we reported an evidence-based computer-assisted decision (CAD) system for location-specific interrogation of mammograms. A content-based image retrieval framework with information theoretic (IT) similarity measures serves as the foundation for this system. Specifically, the normalized mutual information (NMI) was shown to be the most effective similarity measure for reduction of false-positive marks generated by other prescreening mass detection schemes. The objective of this work was to investigate the importance of image filtering as a possible preprocessing step in our IT-CAD system. MATERIALS AND METHODS Different filters were applied, each one aiming to compensate for known limitations of the NMI similarity measure. The study was based on a region-of-interest database that included true masses and false-positive regions from digitized mammograms. RESULTS Receiver-operating characteristics (ROC) analysis showed that IT-CAD is affected slightly by image filtering. Modest, yet statistically significant, performance gain was observed with median filtering (overall ROC area index A(z) improved from 0.78 to 0.82). However, Gabor filtering improved performance for the high-sensitivity portion of the ROC curve where a typical false-positive reduction scheme should operate (partial ROC area index (0.90)A(z) improved from 0.33 to 0.37). Fusion of IT-CAD decisions from different filtering schemes markedly improved performance (A(z) = 0.90 and (0.90)A(z) = 0.55). At 95% sensitivity, the systems specificity improved by 36.6%. CONCLUSIONS Additional improvement in false-positive reduction can be achieved by incorporating image filtering as a preprocessing step in our IT-CAD system.


Radiology | 2011

Computer-aided classification of breast masses: Performance and interobserver variability of expert radiologists versus residents

Swatee Singh; Jeff Maxwell; Jay A. Baker; Jennifer L. Nicholas; Joseph Y. Lo

PURPOSE To evaluate the interobserver variability in descriptions of breast masses by dedicated breast imagers and radiology residents and determine how any differences in lesion description affect the performance of a computer-aided diagnosis (CAD) computer classification system. MATERIALS AND METHODS Institutional review board approval was obtained for this HIPAA-compliant study, and the requirement to obtain informed consent was waived. Images of 50 breast lesions were individually interpreted by seven dedicated breast imagers and 10 radiology residents, yielding 850 lesion interpretations. Lesions were described with use of 11 descriptors from the Breast Imaging Reporting and Data System, and interobserver variability was calculated with the Cohen κ statistic. Those 11 features were selected, along with patient age, and merged together by a linear discriminant analysis (LDA) classification model trained by using 1005 previously existing cases. Variability in the recommendations of the computer model for different observers was also calculated with the Cohen κ statistic. RESULTS A significant difference was observed for six lesion features, and radiology residents had greater interobserver variability in their selection of five of the six features than did dedicated breast imagers. The LDA model accurately classified lesions for both sets of observers (area under the receiver operating characteristic curve = 0.94 for residents and 0.96 for dedicated imagers). Sensitivity was maintained at 100% for residents and improved from 98% to 100% for dedicated breast imagers. For residents, the computer model could potentially improve the specificity from 20% to 40% (P < .01) and the κ value from 0.09 to 0.53 (P < .001). For dedicated breast imagers, the computer model could increase the specificity from 34% to 43% (P = .16) and the κ value from 0.21 to 0.61 (P < .001). CONCLUSION Among findings showing a significant difference, there was greater interobserver variability in lesion descriptions among residents; however, an LDA model using data from either dedicated breast imagers or residents yielded a consistently high performance in the differentiation of benign from malignant breast lesions, demonstrating potential for improving specificity and decreasing interobserver variability in biopsy recommendations.


Proceedings of SPIE, the International Society for Optical Engineering | 2008

Computer-aided detection of breast masses in tomosynthesis reconstructed volumes using information-theoretic similarity measures

Swatee Singh; Georgia D. Tourassi; Amarpreet S. Chawla; Robert S Saunders; Ehsan Samei; Joseph Y. Lo

The purpose of this project is to study two Computer Aided Detection (CADe) systems for breast masses for digital tomosynthesis using reconstructed slices. This study used eighty human subject cases collected as part of on-going clinical trials at Duke University. Raw projections images were used to identify suspicious regions in the algorithms high sensitivity, low specificity stage using a Difference of Gaussian filter. The filtered images were thresholded to yield initial CADe hits that were then shifted and added to yield a 3D distribution of suspicious regions. The initial system performance was 95% sensitivity at 10 false positives per breast volume. Two CADe systems were developed. In system A, the central slice located at the centroid depth was used to extract a 256 X 256 Regions of Interest (ROI) database centered at the lesion coordinates. For system B, 5 slices centered at the lesion coordinates were summed before the extraction of 256 × 256 ROIs. To avoid issues associated with feature extraction, selection, and merging, information theory principles were used to reduce false positives for both the systems resulting in a classifier performance of 0.81 and 0.865 Area Under Curve (AUC) with leave-one-case-out sampling. This resulted in an overall system performance of 87% sensitivity with 6.1 FPs/ volume and 85% sensitivity with 3.8 FPs/ volume for systems A and B respectively. This system therefore has the potential to detect breast masses in tomosynthesis data sets.


Medical Imaging 2007: Computer-Aided Diagnosis | 2007

Feasibility study of breast tomosynthesis CAD system

Anna Jerebko; Yuan Quan; Nicolas J. Merlet; Eli Ratner; Swatee Singh; Joseph Y. Lo; Arun Krishnan

The purpose of this study was to investigate feasibility of computer-aided detection of masses and calcification clusters in breast tomosynthesis images and obtain reliable estimates of sensitivity and false positive rate on an independent test set. Automatic mass and calcification detection algorithms developed for film and digital mammography images were applied without any adaptation or retraining to tomosynthesis projection images. Test set contained 36 patients including 16 patients with 20 known malignant lesions, 4 of which were missed by the radiologists in conventional mammography images and found only in retrospect in tomosynthesis. Median filter was applied to tomosynthesis projection images. Detection algorithm yielded 80% sensitivity and 5.3 false positives per breast for calcification and mass detection algorithms combined. Out of 4 masses missed by radiologists in conventional mammography images, 2 were found by the mass detection algorithm in tomosynthesis images.


Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment | 2006

Mass detection in mammographic ROIs using Watson filters

Swatee Singh; A Baydush; Brian P. Harrawood; Joseph Y. Lo

Human vision models have been shown to capture the response of the visual system; their incorporation into the classification stage of a Computer Aided Detection system could improve performance. This study seeks to improve the performance of an automated breast mass detection system by using the Watson filter model versus a Laguerre Gauss Channelized Hotelling Observer (LG-CHO). The LG-CHO and the Watson filter model were trained and tested on a 512x512 ROI database acquired from the Digital Database of Screening Mammography consisting of 800 total ROIs; 200 of which were malignant, 200 were benign and 400 were normal. Half of the ROIs were used to train the weights for ten LG-CHO templates that were later used during the testing stage. For the Watson filter model, the training cases were used to optimize the frequency filter parameter empirically to yield the best ROC Az performance. This set of filter parameters was then tested on the remaining cases. The training Az for the LG-CHO and the Watson filter was 0.896 +/- 0.016 and 0.924 +/- 0.014 respectively. The testing Az for the LG-CHO and Watson filter was 0.849 +/- 0.019 and 0.888 +/- 0.017. With a p-value of 0.029, the difference in testing performance was statistically significant, thus implying that the Watson filter model holds promise for better detection of masses.


Academic Radiology | 2009

Towards Optimized Acquisition Scheme for Multiprojection Correlation Imaging of Breast Cancer

Amarpreet S. Chawla; Robert S. Saunders; Swatee Singh; Joseph Y. Lo; Ehsan Samei

RATIONALE AND OBJECTIVES Correlation imaging (CI) is a form of multiprojection imaging in which multiple images of a patient are acquired from slightly different angles. Information from these images is combined to make the final diagnosis. A critical factor affecting the performance of CI is its data acquisition scheme, because nonoptimized acquisition may distort pathologic indicators. The authors describe a computer-aided detection (CADe) methodology to optimize the acquisition scheme of CI for superior diagnostic accuracy. MATERIALS AND METHODS Images from 106 subjects were used. For each subject, 25 angular projections of a single breast were acquired. Projection images were supplemented with a simulated 3-mm three-dimensional lesion. Each projection was then processed using a traditional CADe algorithm at high sensitivity, followed by the reduction of false-positives by combining the geometric correlation information available from the multiple images. The performance of the CI system was determined in terms of free-response receiver-operating characteristic curves and the areas under receiver-operating characteristic curves. For optimization, the components of acquisition, such as the number of projections and their angular span, were systematically changed to investigate which of the many possible combinations maximized the obtainable CADe sensitivity and specificity. RESULTS The performance of the CI system was improved by increasing the angular span. Increasing the number of angular projections beyond a certain number did not improve performance. Maximum performance was obtained between 7 and 10 projections spanning a maximum angular arc of 45 degrees . CONCLUSION The findings suggest the existence of an optimum acquisition scheme for CI of the breast. CADe results confirmed earlier predictions on the basis of observer models. An optimized CI system may be an important diagnostic tool for improved breast cancer detection.

Collaboration


Dive into the Swatee Singh's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A Baydush

Wake Forest University

View shared research outputs
Researchain Logo
Decentralizing Knowledge