Radiology | 2010

Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction Techniques

Sarabjeet Singh; Mannudeep K. Kalra; Jiang Hsieh; Paul E. Licato; Synho Do; Homer H. Pien; Michael A. Blake

PURPOSE To compare image quality and lesion conspicuity on abdominal computed tomographic (CT) images acquired with different x-ray tube current-time products (50-200 mAs) and reconstructed with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP) techniques. MATERIALS AND METHODS Twenty-two patients (mean age, 60.1 years ± 7.3 [standard deviation]; age range, 52.8-67.4 years; mean weight, 78.9 kg ± 18.3; 12 men, 10 women) gave informed consent for this prospective institutional review board-approved and HIPAA-compliant study, which involved the acquisition of four additional image series at multidetector CT. Images were acquired at different tube current-time products (200, 150, 100, and 50 mAs) and encompassed an abdominal lesion over a 10-cm scan length. Images were reconstructed separately with FBP and with three levels of ASIR-FBP blending. Two radiologists reviewed FBP and ASIR images for image quality in a blinded and randomized manner. Volume CT dose index (CTDI(vol)), dose-length product, patient weight, objective noise, and CT numbers were recorded. Data were analyzed by using analysis of variance and the Wilcoxon signed rank test. RESULTS CTDI(vol) values were 16.8, 12.6, 8.4, and 4.2 mGy for 200, 150, 100, and 50 mAs, respectively (P < .001). Subjective noise was graded as below average at 150 mAs and average at 100 and 50 mAs for ASIR images, as compared with FBP images, on which noise was graded as average at 150 mAs, above average at 100 mAs, and unacceptable at 50 mAs. A substantial blotchy image appearance was noted in four of 22 image series acquired at 4.2 mGy with 70% ASIR. Lesion conspicuity was significantly better at 4.2 mGy on ASIR than on FBP images (observed P < .044), and overall diagnostic confidence changed from unacceptable on FBP to acceptable on ASIR images. CONCLUSION ASIR lowers noise and improves diagnostic confidence in and conspicuity of subtle abdominal lesions at 8.4 mGy when images are reconstructed with 30% ASIR blending and at 4.2 mGy in patients weighing 90 kg or less when images are reconstructed with 50% or 70% ASIR blending.


Radiology | 2010

Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique

Priyanka Prakash; Mannudeep K. Kalra; Jeanne B. Ackman; Subba R. Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O. Shepard; Matthew D. Gilman

PURPOSE To compare visualization of subtle normal and abnormal findings at computed tomography (CT) of the chest for diffuse lung disease with images reconstructed with filtered back projection and adaptive statistical iterative reconstruction (ASIR) techniques. MATERIALS AND METHODS In this HIPAA-compliant, institutional review board-approved study, 24 patients underwent 64-section multi-detector row CT of the chest for evaluation of diffuse lung disease. Scanning parameters included a pitch of 0.984:1 and 120 kVp in thin-section mode, with 2496 views per rotation compared with 984 views acquired for normal mode. The 0.625-mm-thick images were reconstructed with filtered back projection, ASIR, and ASIR high-definition (ASIR-HD) kernels. Two thoracic radiologists independently assessed the filtered back projection, ASIR, and ASIR-HD images for small anatomic details (interlobular septa, centrilobular region, and small bronchi and bronchioles), abnormal findings (reticulation, tiny nodules, altered attenuation, bronchiectasis), image quality (graded by using a six-point scale, where 1 = excellent image quality, and 5 = interpretation impossible), image noise, and artifacts. Data were tabulated for statistical testing. RESULTS For visualization of normal and pathologic structures, CT image series reconstructed with ASIR-HD were rated substantially better than those reconstructed with filtered back projection and ASIR (P < .001). ASIR-HD images were superior to filtered back projection images in 15 of 24 (62%) patients for visualization of normal structures and in 24 of 24 (100%) patients for pathologic findings. ASIR-HD was superior to ASIR in three of 24 (12%) images for normal anatomic findings and in seven of 24 (29%) images for pathologic evaluation. None of the images in the three groups were rated as unacceptable for noise (P < .001). CONCLUSION ASIR-HD reconstruction results in superior visualization of subtle and tiny anatomic structures and lesions in diffuse lung disease compared with ASIR and filtered back projection reconstructions.


Journal of Computer Assisted Tomography | 2012

Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.

Sarabjeet Singh; Mannudeep K. Kalra; Synho Do; Thibault Jb; Homer Pien; Owen J. O'Connor; Michael A. Blake

Purpose Assess the effect of filtered back projection (FBP) and hybrid (adaptive statistical iterative reconstruction [ASIR]) and pure (model-based iterative reconstruction [MBIR]) iterative reconstructions on abdominal computed tomography (CT) acquired with 75% radiation dose reduction. Materials and Methods In an institutional review board–approved prospective study, 10 patients (mean [standard deviation] age, 60 (8) years; 4 men and 6 women) gave informed consent for acquisition of additional abdominal images on 64-slice multidetector-row CT (GE 750HD, GE Healthcare). Scanning was repeated over a 10-cm scan length at 200 and 50 milliampere second (mA s), with remaining parameters held constant at 120 kilovolt (peak), 0.984:1 pitch, and standard reconstruction kernel. Projection data were deidentified, exported, and reconstructed to obtain 4 data sets (200-mA s FBP, 50-mA s FBP, 50-mA s ASIR, 50-mA s MBIR), which were evaluated by 2 abdominal radiologists for lesions and subjective image quality. Objective noise and noise spectral density were measured for each image series. Results Among the 10 patients, the maximum weight recorded was 123 kg, with maximum transverse diameter measured as 43.7 cm. Lesion conspicuity at 50-mA s MBIR was better than on 50-mA s FBP and ASIR images (P < 0.01). Image noise was rated as suboptimal on low-dose FBP and ASIR but deemed acceptable in MBIR images. Objective noise with 50-mA s MBIR was 2 to 3 folds lower compared to 50-mA s ASIR, 50-mA s FBP, and 200-mA s FBP (P < 0.0001). Noise spectral density analyses demonstrated that ASIR retains the noise spectrum signature of FBP, whereas MBIR has much lower noise with a more regularized noise spectrum pattern. Conclusion Model-based iterative reconstruction renders acceptable image quality and diagnostic confidence in 50- mA s abdominal CT images, whereas FBP and ASIR images are associated with suboptimal image quality at this radiation dose level.


European Journal of Radiology | 2012

Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique

Hans Scheffel; Paul Stolzmann; Christopher L. Schlett; Leif-Christopher Engel; Gyöngi Petra Major; Mihály Károlyi; Synho Do; Pál Maurovich-Horvat; Udo Hoffmann

OBJECTIVES To compare image quality of coronary artery plaque visualization at CT angiography with images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model based iterative reconstruction (MBIR) techniques. METHODS The coronary arteries of three ex vivo human hearts were imaged by CT and reconstructed with FBP, ASIR and MBIR. Coronary cross-sectional images were co-registered between the different reconstruction techniques and assessed for qualitative and quantitative image quality parameters. Readers were blinded to the reconstruction algorithm. RESULTS A total of 375 triplets of coronary cross-sectional images were co-registered. Using MBIR, 26% of the images were rated as having excellent overall image quality, which was significantly better as compared to ASIR and FBP (4% and 13%, respectively, all p<0.001). Qualitative assessment of image noise demonstrated a noise reduction by using ASIR as compared to FBP (p<0.01) and further noise reduction by using MBIR (p<0.001). The contrast-to-noise-ratio (CNR) using MBIR was better as compared to ASIR and FBP (44±19, 29±15, 26±9, respectively; all p<0.001). CONCLUSIONS Using MBIR improved image quality, reduced image noise and increased CNR as compared to the other available reconstruction techniques. This may further improve the visualization of coronary artery plaque and allow radiation reduction.


American Journal of Roentgenology | 2013

Sinogram-affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose.

Mannudeep K. Kalra; Nils Dahlström; Sarabjeet Singh; Subbarao Digumarthy; Synho Do; Homer Pien; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Jo-Anne O. Shepard; Anders Persson

OBJECTIVE. The purpose of this study is to compare sinogram-affirmed iterative reconstruction (SAFIRE) and filtered back projection (FBP) reconstruction of chest CT acquired with 65% radiation dose reduction. MATERIALS AND METHODS. In this prospective study involving 24 patients (11 women and 13 men; mean [± SD] age, 66 ± 10 years), two scan series were acquired using 100 and 40 Quality Reference mAs over a 10-cm scan length in the chest with a 128-MDCT scanner. The 40 Quality Reference mAs CT projection data were reconstructed with FBP and four settings of SAFIRE (S1, S2, S3, and S4). Six image datasets (FBP with 100 and 40 Quality Reference mAs, and S1, S2, S3, S4 with 40 Quality Reference mAs) were displayed on a DICOM-compliant 55-inch 2-megapixel monitor for blinded evaluation by two thoracic radiologists for number and location of lesions, lesion size, lesion margins, visibility of small structures and fissures, and diagnostic confidence. Objective noise and CT values were measured in thoracic aorta for each image series, and the noise power spectrum was assessed. Data were analyzed with analysis of variance and Wilcoxon signed rank tests. RESULTS. All 186 lesions were seen on 40 Quality Reference mAs SAFIRE images. Diagnostic confidence on SAFIRE images was higher than that for FBP images. Except for the minor blotchy appearance on SAFIRE settings S3 and S4, no significant artifacts were noted. Objective noise with 40 Quality Reference mAs S1 images (21.1 ± 6.1 SD of HU) was significantly lower than that for 40 Quality Reference mAs FBP images (28.5 ± 8.1 SD of HU) (p < 0.001). Noise power spectra were identical for SAFIRE and FBP with progressive noise reduction with higher iteration SAFIRE settings. CONCLUSION. Iterative reconstruction (SAFIRE) allows reducing the radiation exposure by approximately 65% without losing diagnostic information in chest CT.


international symposium on biomedical imaging | 2009

Multi GPU implementation of iterative tomographic reconstruction algorithms

Byunghyun Jang; David R. Kaeli; Synho Do; Homer H. Pien

Although iterative reconstruction techniques (IRTs) have been shown to produce images of superior quality over conventional filtered back projection (FBP) based algorithms, the use of IRT in a clinical setting has been hampered by the significant computational demands of these algorithms. In this paper we present results of our efforts to overcome this hurdle by exploiting the combined computational power of multiple graphical processing units (GPUs). We have implemented forward and backward projection steps of reconstruction on an NVIDIA Tesla S870 hardware using CUDA. We have been able to accelerate forward projection by 71x and backward projection by 137x. We generate these results with no perceptible difference in image quality between the GPU and serial CPU implementations. This work illustrates the power of using commercial off-the-shelf relatively low-cost GPUs, potentially allowing IRT tomographic image reconstruction to be run in near real time, lowering the barrier to entry of IRT, and enabling deployment in the clinic.


Journal of Computer Assisted Tomography | 2014

Computed tomography (CT) of the chest at less than 1 mSv: an ongoing prospective clinical trial of chest CT at submillisievert radiation doses with iterative model image reconstruction and iDose4 technique.

Ranish Deedar Ali Khawaja; Sarabjeet Singh; Matthew D. Gilman; Amita Sharma; Synho Do; Sarvenaz Pourjabbar; Atul Padole; Diego Lira; Kevin K. Brown; Jo-Anne O. Shepard; Mannudeep K. Kalra

Purpose To assess lesion detection and diagnostic confidence of computed tomography (CT) of the chest performed at less than 1 mSv with 2 iterative reconstruction (IR) techniques. Materials and Methods Ten patients gave written informed consent for the acquisitions of images at submillisievert dose (0.9 mSv), in addition to clinical standard-dose (SD) chest CT (2.9 mSv). Submillisievert images were reconstructed with iDose4 and iterative model reconstruction (IMR). Two radiologists assessed lesion detection, margins, diagnostic confidence, and visibility of small structures. Objective noise and noise spectral density were measured. Results Lesion detection was identical for standard-dose filtered back projection (FBP), submSv iDose4, and submSv IMR. Lesion margins were better seen for 30% of detected lung lesions with submSv IMR compared to standard-dose FBP and submSv iDose4 (P < 0.05). Visibility of abdominal structures, and diagnostic confidence with submSv iDose4 and submSv IMR were similar to standard-dose FBP. There was 21% to 64% noise reduction with submSv IMR and 1% to 15% higher noise with iDose4 compared to standard-dose FBP (P < 0.0001). Conclusions Submillisievert IMR improves delineation of lesion margins compared to standard-dose FBP and submSv iDose4.


The American Journal of Medicine | 2012

Evolution of Coronary Computed Tomography Radiation Dose Reduction at a Tertiary Referral Center

Brian B. Ghoshhajra; Leif Christopher Engel; Gyöngyi Petra Major; Alexander Goehler; Tust Techasith; Daniel Verdini; Synho Do; Bob Liu; Xinhua Li; Michiel Sala; Mi Sung Kim; Ron Blankstein; Priyanka Prakash; Manavjot S. Sidhu; Erin Corsini; Dahlia Banerji; David Wu; Suhny Abbara; Quynh A. Truong; Thomas J. Brady; Udo Hoffmann; Manudeep Kalra

PURPOSE We aimed to assess the temporal change in radiation doses from coronary computed tomography angiography (CCTA) during a 6-year period. High CCTA radiation doses have been reduced by multiple technologies that, if used appropriately, can decrease exposures significantly. METHODS A total of 1277 examinations performed from 2005 to 2010 were included. Univariate and multivariable regression analysis of patient- and scan-related variables was performed with estimated radiation dose as the main outcome measure. RESULTS Median doses decreased by 74.8% (P<.001), from 13.1 millisieverts (mSv) (interquartile range 9.3-14.7) in period 1 to 3.3 mSv (1.8-6.7) in period 4. Factors associated with greatest dose reductions (P<.001) were all most frequently applied in period 4: axial-sequential acquisition (univariate: -8.0 mSv [-9.7 to -7.9]), high-pitch helical acquisition (univariate: -8.8 mSv [-9.3 to -7.9]), reduced tube voltage (100 vs 120 kV) (univariate: -6.4 mSv [-7.4 to -5.4]), and use of automatic exposure control (univariate: -5.3 mSv [-6.2 to -4.4]). CONCLUSIONS CCTA radiation doses were reduced 74.8% through increasing use of dose-saving measures and evolving scanner technology.


European Journal of Radiology | 2015

Ultra-low dose abdominal MDCT: using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study.

Ranish Deedar Ali Khawaja; Sarabjeet Singh; Michael A. Blake; Mukesh G. Harisinghani; Garry Choy; Ali Karosmangulu; Atul Padole; Synho Do; Kevin M. Brown; Richard Thompson; Thomas Morton; Nilgoun Raihani; Thomas Koehler; Mannudeep K. Kalra

PURPOSE To assess lesion detection and image quality parameters of a knowledge-based Iterative Model Reconstruction (IMR) in reduced dose (RD) abdominal CT examinations. MATERIALS AND METHODS This IRB-approved prospective study included 82 abdominal CT examinations performed for 41 consecutive patients (mean age, 62 ± 12 years; F:M 28:13) who underwent a RD CT (SSDE, 1.5 mGy ± 0.4 [∼ 0.9 mSv] at 120 kV with 17-20 mAs/slice) immediately after their standard dose (SD) CT exam (10 mGy ± 3 [∼ 6 mSv] at 120 kV with automatic exposure control) on 256 MDCT (iCT, Philips Healthcare). SD data were reconstructed using filtered back projection (FBP). RD data were reconstructed with FBP and IMR. Four radiologists used a five-point scale (1=image quality better than SD CT to 5=image quality unacceptable) to assess both subjective image quality and artifacts. Lesions were first detected on RD FBP images. RD IMR and RD FBP images were then compared side-by-side to SD-FBP images in an independent, randomized and blinded fashion. Friedmans test and intraclass correlation coefficient were used for data analysis. Objective measurements included image noise and attenuation as well as noise spectral density (NSD) curves to assess the noise in frequency domain were obtained. In addition, a low-contrast phantom study was performed. RESULTS All true lesions (ranging from 32 to 55) on SD FBP images were detected on RD IMR images across all patients. RD FBP images were unacceptable for subjective image quality. Subjective ratings showed acceptable image quality for IMR for organ margins, soft-tissue structures, and retroperitoneal lymphadenopathy, compared to RD FBP in patients with a BMI ≤ 25 kg/m(2) (median-range, 2-3). Irrespective of patient BMI, subjective ratings for hepatic/renal cysts, stones and colonic diverticula were significantly better with RD IMR images (P<0.01). Objective image noise for RD FBP was 57-66% higher, and for RD IMR was 8-56% lower than that for SD-FBP (P<0.01). NSD showed significantly lower noise in the frequency domain with IMR in all patients compared to FBP. CONCLUSION IMR considerably improved both objective and subjective image quality parameters of RD abdominal CT images compared to FBP in patients with BMI less than or equal to 25 kg/m(2).


American Journal of Roentgenology | 2014

Submillisievert Chest CT With Filtered Back Projection and Iterative Reconstruction Techniques

Atul Padole; Sarabjeet Singh; Jeanne B. Ackman; Carol C. Wu; Synho Do; Sarvenaz Pourjabbar; Ranish Deedar Ali Khawaja; Alexi Otrakji; Subba R. Digumarthy; Jo-Anne O. Shepard; Mannudeep K. Kalra

OBJECTIVE The purpose of this study was to compare submillisievert chest CT images reconstructed with filtered back projection (FBP), SafeCT, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) with standard of care FBP images. SUBJECTS AND METHODS Fifty patients (33 men and 17 women; mean age [± SD], 62 ± 10 years) undergoing routine chest CT gave written informed consent for acquisition of an additional submillisievert chest CT series with reduced tube current but identical scanning length as standard of care chest CT. Sinogram data of the submillisievert series were reconstructed with FBP, SafeCT, ASIR, and MBIR and compared with FBP images at standard-dose chest CT (n = 8 × 50 = 400 series). Two thoracic radiologists performed independent comparison for visualization of lesion margin, visibility of small structures, and diagnostic acceptability. Objective noise measurements and noise spectral density were obtained. RESULTS Of 287 detected lesions, 162 were less than 1-cm noncalcified nodules. Lesion margins were well seen on all submillisievert reconstruction images except MBIR, on which they were poorly visualized. Likewise, only submillisievert MBIR images were suboptimal for visibility of normal structures, such as pulmonary vessels in the outer 2 cm of the lung, interlobular fissures, and subsegmental bronchial walls. MBIR had the lowest image noise compared with other techniques. CONCLUSION FBP, SafeCT, ASIR, and MBIR can enable optimal lesion evaluation on chest CT acquired at a volume CT dose index of 2 mGy. However, all submillisievert reconstruction techniques were suboptimal for visualization of mediastinal structures. Submillisievert MBIR images were suboptimal for visibility of normal lung structures despite showing lower image noise.

Collaboration


Dive into the Synho Do's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vasilis Z. Marmarelis

University of Southern California

View shared research outputs
Researchain Logo
Decentralizing Knowledge