Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where T. Hofmann is active.

Publication


Featured researches published by T. Hofmann.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016

Experimental results of the laserwire emittance scanner for LINAC4 at CERN

T. Hofmann; G. Boorman; Alessio Bosco; E. Bravin; S. M. Gibson; Konstantin Kruchinin; Uli Raich; Federico Roncarolo; Francesca Zocca

Abstract Within the framework of the LHC Injector Upgrade (LIU), the new LINAC4 is currently being commissioned to replace the existing LINAC2 proton source at CERN. After the expected completion at the end of 2016, the LINAC4 will accelerate H − ions to 160xa0MeV. To measure the transverse emittance of the H − beam, a method based on photo-detachment is proposed. This system will operate using a pulsed laser with light delivered via an optical fibre and subsequently focused onto the H − beam. The laser photons have sufficient energy to detach the outer electron and create H 0 /e − pairs. In a downstream dipole, the created H 0 particles are separated from the unstripped H − ions and their distribution is measured with a dedicated detector. By scanning the focused laser beam across the H − beam, the transverse emittance of the H − beam can be reconstructed. This paper will first discuss the concept, design and simulations of the laser emittance scanner and then present results from a prototype system used during the 12xa0MeV commissioning of the LINAC4.


Physical Review Special Topics-accelerators and Beams | 2015

Demonstration of a laserwire emittance scanner for hydrogen ion beams at CERN

T. Hofmann; Konstantin Kruchinin; Alessio Bosco; S. M. Gibson; Federico Roncarolo; G. Boorman; Uli Raich; E. Bravin; J. Pozimski; Alan Letchford; Christoph Gabor

A non-invasive, compact laserwire system has been developed to measure the transverse emittance of an H- beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed via fibre to collide with the H- beam, a fraction of which is neutralized and then intercepted by a downstream diamond detector. Scanning the focused laser across the H- beam and measuring the distribution of the photo-neutralized particles enables the transverse emittance to be reconstructed. The vertical phase-space distribution of a 3 MeV beam during LINAC4 commissioning has been measured by the laserwire and verified with a conventional slit and grid method.


7th International Particle Accelerator Conference (IPAC'16), Busan, Korea, May 8-13, 2016 | 2016

Beam Instrumentation Performance during Commissioning of CERN's Linac-4 to 50 MeV and 100 MeV

Uli Raich; T. Hofmann; Federico Roncarolo

Linac-4, a 160 MeV H linear accelerator is designed to replace the aging 50 MeV proton Linac-2. It will consist of an H source and 45 keV LEBT, an RFQ and 3 MeV MEBT with a chopper, 3 drift tube linac (DTL) tanks accelerating the beam to 12, 30 and 50 Mev, cavity coupled structures (CCDTL) accelerating it to 100 MeV and a pi mode structure (PIMS) bringing it to its design energy of 160 MeV. This paper reports on the commissioning of the DTL and CCDTL with 2 dedicated temporary measurement lines, the first one adapted to the 12 MeV beam while the second one is dedicated to characterize the 50 MeV and the 100 MeV beams. The beam diagnostic devices used in these lines are described as well as results obtained. 3 AND 12 MEV MEASUREMENT LINE The Linac-4 accelerator is being assembled in stages. At each stage the beam is fully characterized, and the measurement results are compared to beam optics simulations. While many diagnostic devices are permanently installed in the machine and will be used for routine operation, dedicated temporary measurement lines were designed to determine beam characteristics after the RFQ at 3 MeV and after the first DTL tank at 12 MeV. Figure 1: 3 and 12 MeV measurement line. The following devices were installed on the 3 and 12 MeV measurement line: • Slit/grid emittance meter [1] (yellow) • 2 Beam Current Transformers (BCTs) (orange) • 2 Beam Position Monitors (BPMs) (light blue) • Spectrometer (green) • Bunch shape monitor (violet) • Laser emittance meter [2] (red) with a diamond detector (blue) The BCTs were the first instruments to see the beam as it passed through the RFQ and the first DTL tank. They have calibration windings into which a precise current is injected after each beam pulse, providing an absolute calibration. BCTs were extensively used to optimize transmission. Transverse Emittance The slit/grid device directly measured the transverse phasespace with the results compared to simulation. Similar measurements were made with the laser emittance meter, where the laser acts as the slit, neutralizing a small part of the H beam [3]. While the remaining H beam was deflected into the spectrometer line, the angular distribution of the neutralized Hs were detected with a diamond detector. Good agreement was found between both measurement techniques, providing important input for understanding the initial phase space distribution of the beam. 50 AND 100 MEV MEASUREMENT LINE Due to the energy-deposition in the slit, the slit/grid device could not be used at energies higher than 12 MeV. Equally the spectrometer could not handle higher energies because of the limited field in the spectrometer magnet. Figure 2: Phase space measured with slit/grid and laser emittance meter at 12 MeV. Proceedings of IPAC2016, Busan, Korea MOPMR026 06 Beam Instrumentation, Controls, Feedback and Operational Aspects T03 Beam Diagnostics and Instrumentation ISBN 978-3-95450-147-2 293 C op yr ig ht


Archive | 2014

A FIBRE COUPLED, LOW POWER LASERWIRE EMITTANCE SCANNER AT CERN LINAC4

S. M. Gibson; Alessio Bosco; P. Savage; Konstantin Kruchinin; Federico Roncarolo; Alan Letchford; G. Boorman; J. Pozimski; Christoph Gabor; T. Hofmann


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2018

A low-power laserwire profile monitor for H− beams: Design and experimental results

T. Hofmann; G. Boorman; Alessio Bosco; S. M. Gibson; Federico Roncarolo


Archive | 2017

JACoW : Beam Instrumentation for the CERN LINAC4 and PSB Half Sector Test

Federico Roncarolo; L. Jensen; Juan Allica Santamaria; Greta Guidoboni; Stephane Burger; Araceli Navarro Fernandez; Christos Zamantzas; Chiara Bracco; Christophe Vuitton; J Tan; W. Vigano; Lars Søby; Uli Raich; Gerrit Jan Focker; B Mikulec; Julien-Benjamin Ruiz; T. Hofmann; Michele Bozzolan


Archive | 2017

JACoW : Experimental Results of a Compact Laserwire System for Non-Invasive H⁻ Beam Profile Measurements at CERN's Linac4

S. M. Gibson; Uli Raich; Alessio Bosco; G. Boorman; T. Hofmann; Federico Roncarolo


4th International Beam Instrumentation Conference (IBIC2015), Melbourne, Australia, 13-17 September 2015 | 2016

Design of a Laser-based Profile Monitor for LINAC4 Commissioning at 50 MeV and 100 MeV

T. Hofmann; Alessio Bosco; S. M. Gibson; E. Bravin; Federico Roncarolo; G. Boorman; Erich Griesmayer; Uli Raich


Archive | 2015

Laserwire Emittance Scanner at CERN Linac 4

Konstantin Kruchinin; Alessio Bosco; S. M. Gibson; E. Bravin; Francesca Zocca; Federico Roncarolo; Alan Letchford; P. Karataev; J. Pozimski; Uli Raich; G. Boorman; T. Hofmann

Collaboration


Dive into the T. Hofmann's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alan Letchford

Rutherford Appleton Laboratory

View shared research outputs
Top Co-Authors

Avatar

J. Pozimski

Imperial College London

View shared research outputs
Researchain Logo
Decentralizing Knowledge