Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Tae Sig Jeung is active.

Publication


Featured researches published by Tae Sig Jeung.


Medical Physics | 2007

Guiding curve based on the normal breathing as monitored by thermocouple for regular breathing

Sangwook Lim; Sung Ho Park; Seung Do Ahn; Yelin Suh; Seong Soo Shin; Sangwook Lee; Jong Hoon Kim; Eun Kyoung Choi; Byong Yong Yi; Soo Il Kwon; Sookil Kim; Tae Sig Jeung

Adapting radiation fields to a moving target requires information continuously on the location of internal target by detecting it directly or indirectly. The aim of this study is to make the breathing regular effectively with minimizing stress to the patient. A system for regulating patients breath consists of a respiratory monitoring mask (ReMM), a thermocouple module, a screen, inner earphones, and a personal computer. A ReMM with thermocouple was developed previously to measure the patients respiration. A software was written in LabView 7.0 (National Instruments, TX), which acquires respiration signal and displays its pattern. Two curves are displayed on the screen: One is a curve indicating the patients current breathing pattern; the other is a guiding curve, which is iterated with one period of the patients normal breathing curve. The guiding curves were acquired for each volunteer before they breathed with guidance. Ten volunteers participated in this study to evaluate this system. A cycle of the representative guiding curve was acquired by monitoring each volunteers free breathing with ReMM and was then generated iteratively. The regularity was compared between a free breath curve and a guided breath curve by measuring standard deviations of amplitudes and periods of two groups of breathing. When the breathing was guided, the standard deviation of amplitudes and periods on average were reduced from 0.0029 to 0.00139 (arbitrary units) and from 0.359 s to 0.202 s, respectively. And the correlation coefficients between breathing curves and guiding curves were greater than 0.99 for all volunteers. The regularity was improved statistically when the guiding curve was used.


Medical Dosimetry | 2012

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

Sangwook Lim; Sun Young Ma; Tae Sig Jeung; Byong Yong Yi; Sang Hoon Lee; Suk Lee; Sam Ju Cho; Jinho Choi

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.


Case Reports in Clinical Medicine | 2015

Results of Oncothermia Combined with Operation, Chemotherapy and Radiation Therapy for Primary, Recurrent and Metastatic Sarcoma

Tae Sig Jeung; Sun Young Ma; JiHoon Choi; Jeasang Yu; Su Yong Lee; Sangwook Lim


Tuberculosis and Respiratory Diseases | 2004

Concurrent Docetaxel/Cisplatin and Thoracic Radiotherapy for Locally Advanced Non-Small Cell Lung Cancer

Tae Won Jang; Jung Pil Park; Hee Kyoo Kim; Chul Ho Ok; Tae Sig Jeung; Maan Hong Jung


Progress in Medical Physics | 2013

Quantitative Evaluation of Gated Radiation Therapy Using Gamma Index Analysis

Sun Young Ma; Ji Hoon Choi; Tae Sig Jeung; Sangwook Lim


Journal of the Korean Physical Society | 2008

Determination of target motion by using a respiration monitoring mask for 4-D radiotherapy

Sangwook Lim; Tae Sig Jeung; Sung Ho Park; Seung Do Ahn; Suk Lee; Chul Yong Kim; Byong Yong Yi; Sang Hoon Lee; Kwang Hwan Cho; Jisun Jang; Soo Il Kwon; Hyun Do Huh; Dongho Shin; Tae-Suk Suh


Progress in Medical Physics | 2014

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy

Sun Young Ma; Tae Sig Jeung; Jang Bo Shim; Sangwook Lim


Progress in Medical Physics | 2014

Discrepancies between Calculated and Delivered Dose Distributions of Respiratory Gated IMRT Fields according to the Target Motion Ranges for Lung and Liver Cancer Patients

Youngkuk Kim; Sangwook Lim; Ji Hoon Choi; Sun Young Ma; Tae Sig Jeung; Tae Ik Ro


Korean Journal of Medical Physics | 2011

Analysis of Overall Setup Accuracy Using On-Board Imager(R).

Sun Young Ma; Sangwook Lim; Sooman Kang; Tae Sig Jeung


Korean Journal of Medical Physics | 2010

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask.

Sookil Kim; Tae Sig Jeung; Sangwook Lim; Yeong Mouk Park; Dahl Park

Collaboration


Dive into the Tae Sig Jeung's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge