Publication


Featured researches published by Takao Takada.


Academic Radiology | 1996

Physical and clinical evaluation of a 2,048 × 2,048-matrix image intensifier TV digital imaging system in bone radiography

Yoshiharu Higashida; Yuji Baba; Masahiro Hatemura; Akira Yoshida; Takao Takada; Mutsumasa Takahashi

RATIONALE AND OBJECTIVES To evaluate the potential utility of a 2,048 x 2,048-matrix image intensifier television digital radiography (DR) system versus a conventional screen-film (S-F) system for bone radiography. METHODS Basic imaging properties were evaluated including resolution properties, Wiener spectra, and detectabilities of low-contrast signals. DR images were obtained with the same exposure (iso-dose) or one-third the exposure (low-dose) used with the S-F system. The visibility of pathologic details of metastatic disease on bone radiographs of 27 patients was evaluated subjectively by six radiologists. RESULTS Resolution properties of the DR system were slightly superior to those of the S-F system at low-frequency range, but the S-F system showed considerably higher resolution properties at the high-frequency range. The noise levels for iso-dose DR were slightly greater than those for S-F imaging at low spatial frequency; however, low-dose digital radiographs showed higher noise levels. Visibility of details of diagnostic features on bone radiographs was similar with both systems, but the low-dose digital radiographs were slightly inferior. CONCLUSION High-resolution image intensifier television DR systems may be clinically useful for bone radiography.


Medical Physics | 2000

Dose calculation for asymmetric photon fields with independent jaws and multileaf collimators

Fujio Araki; Ryuji Ikeda; Nobuyuki Moribe; Yuichi Shirakawa; Masahiro Hatemura; Toshiaki Shimonobou; Yukinori Hirata; Takao Takada; Mutsumasa Takahashi; M. Matoba

We have developed a simple method for dose calculation in dual asymmetric open and irregular fields with four independent jaws and multileaf collimators. Our calculation method extends the scatter correction method of Kwa et al. [Med. Phys. 21, 1599-1604 (1994)] based on the principle of Days equivalent-field calculation. The scatter correction factor was determined by the ratio of the derived doses of a smaller asymmetric open field or irregular field to a larger symmetric field. The algorithm with the scatter correction method can be calculated from output factors, tissue maximum ratios, and off-axis ratios for conventional symmetric fields. The doses calculated by this method were compared with the measured doses for various asymmetric open and irregular fields. The agreement between the calculated and measured doses for 4 and 10 MV photon beams was within 0.5% at the geometric center of the asymmetric open fields. For the asymmetric irregular fields with the same geometrical center, agreement within 1% was found in most cases.


Physics in Medicine and Biology | 2000

Wall correction factors for calibration of plane-parallel ionization chambers with high-energy photon beams

Fujio Araki; Ryuji Ikeda; Yuichi Shirakawa; Toshiaki Shimonobou; Nobuyuki Moribe; Takao Takada; Mutsumasa Takahashi; Hiroki Oura; M. Matoba

Most dosimetry protocols recommend that calibration of plane-parallel ionization chambers be performed in an electron beam of sufficiently high energy by comparison with cylindrical chambers. For various plane-parallel chambers, the 1997 IAEA TRS-381 protocol includes an overall perturbation factor pQ for electron beams, a wall correction factor p(wall) for a 60Co beam and the product of two wall corrections k(att)k(m) for 60Co in-air calibration. The recommended values of p(wall) for plane-parallel chambers, however, are limited to certain phantom materials and a 60Co beam, and are not given for other phantom materials and x-ray beams. In this work, the p(wall) values of the commercially available NACP, PTW/Markus and PTW/Roos plane-parallel chambers in a solid water phantom have been determined with 60Co and 4 and 10 MV photon beams. The k(att)k(m) values for the NACP and PTW/Markus chambers have also been obtained. The wall correction factors p(wall) and k(att)k(m) have been determined by intercomparison with a calibrated Farmer chamber. The average value of p(wall) for these plane-parallel chambers was 1.005 +/- 0.1% (1 SD) for 60Co beams and 1.007 +/- 0.2% (1 SD) for both 4 MV and 10 MV photons. The k(att)k(m) values for the NACP and PTW/Markus chambers were about 1.5% lower than other published data.


Investigative Radiology | 1992

Development of a 2,048 x 2,048-pixel image intensifier-TV digital radiography system. Basic imaging properties and clinical application.

Mutsumasa Takahashi; Sukeyoshi Ueno; Tadatoshi Tsuchigame; Yoshiharu Higashida; Yukinori Hirata; Nobuyuki Moribe; Takao Takada; Masami Kamiya; Koichi Koike


Japanese journal of medical physics : an official journal of Japan Society of Medical Physics | 2000

Determination of overall perturbation factors for plane-parallel ionization chambers in electron beams.

Fujio Araki; Yuichi Shirakawa; Ryuji Ikeda; Toshiaki Shimonobou; Nobuyuki Moribe; Takao Takada; Mutsumasa Takahashi; Hiroki Oura; M. Matoba


Japanese journal of medical physics : an official journal of Japan Society of Medical Physics | 2000

The Influence of DSA Examinations on Patient-absorbed Doses

Yoshinori Funama; Takehiro Uchida; Masamichi Shimamura; Seishi Doudanuki; Takao Takada


Japanese Journal of Radiological Technology | 1998

half Fourier single shot turbo spin echo(HASTE)法における空間的ボケについて

Yoshinori Funama; Yasuhiro Hiai; Takwhiro Uchida; Masato Maruyama; Nozomu Nagasue; Takao Takada; Mutsumasa Takahashi


Japanese Journal of Radiological Technology | 1997

Evaluation of enhanced MRA using subtrction method in pelvis and lower extrimities.

Masato Maruyama; Yasuhiro Hiai; Yoshinori Funama; Nozomu Nagasue; Ryuuji Ikeda; Seishi Doudanuki; Takao Takada; Mutsumasa Takahashi


Japanese Journal of Radiological Technology | 1997

Evaluation of New Grids for Bedside Chest Radiography: : Effects of X-ray Beam Misalignment

Masahiro Hatemura; Ryuji Ikeda; Yoshiharu Higashida; Noboru Katsuda; Nobuyuki Moribe; Takao Takada; Mutsumasa Takahashi


Japanese Journal of Radiological Technology | 1997

Evaluation of Image Performance of Film Changers

Yuichi Shirakawa; Masahiro Hatemura; Yoshio Sonoda; Takao Takada; Mutsumasa Takahashi; Yoshiharu Higashida

Collaboration


Dive into the Takao Takada's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge