Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Takayoshi Ozaki is active.

Publication


Featured researches published by Takayoshi Ozaki.


Asaio Journal | 2000

Terumo implantable left ventricular assist system: results of long-term animal study.

Chisato Nojiir; Toshihiko Kijima; Jun Maekawa; Kunio Horiuchi; Takayuki Kido; Tomoko Sugiyama; Takehisa Mori; Naoya Sugiura; Takehiko Asada; Takayoshi Ozaki; Minoru Suzuki; Teruaki Akamatsu; Tetsuzo Akutsu

The research group of Terumo Corporation, NTN Corporation, and the Setsunan University have been developing an implantable left ventricular assist system (T-ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The present study describes results of chronic animal experiments using the MSCP. The MSCP has been tested ex vivo and in vivo in 6 sheep as a left heart bypass between the left ventricular apex and descending aorta. Ex vivo chronic sheep experiments using Model I demonstrated long-term durability, nonthrombogenicity, low hemolysis (<6 mg/dl), and excellent stability of the magnetic bearing with long-term survival for up to 864 days. Average pump flow rate was 4 L/min at a fixed rotational speed of 2000 rpm. Power spectral analyses of heart rate, aortic pressure, and blood temperature maintained normal 1/f fluctuation during the study. The retrieved pump was completely free from thrombus formation and there was no evidence of infarct in major organs. The implantable Model II was evaluated ex vivo in two sheep and intra-thoracically implanted in a sheep. These experiments were terminated at 70, 79, and 17 days due to blood leakage through the connector system within the housing. No thrombus formation was observed in any of the retrieved pumps. A modified Model II with a new connector system was subsequently intra-thoracically implanted in a sheep. The sheep survived for 482 days without any sign of thromboembolic complication or hemolysis at a fixed rotational speed of 1700 rpm and an average pump flow rate of 5 L/min. There was no intra-device thrombus formation or infarct in major organs. The Model III system, consisting of an implantable controller and a new MSCP with a reduced input power of 13 W, has been developed and implanted in a chronic sheep model. The MSCP was implanted in the left pleural space and the controller in the abdominal wall. The experiment is still in progress for more than 30 days without any significant complication to date. These animal studies strongly suggest the feasibility of the MSCP for use as long-term circulatory assist.


Asaio Journal | 1999

Recent progress in the development of Terumo implantable left ventricular assist system.

Chisato Nojiri; Toshihiko Kijima; Jun Maekawa; Kunio Horiuchi; Takayuki Kido; Tomoko Sugiyama; Takehisa Mori; Naoya Sugiura; Takehiko Asada; Hiroshi Shimane; Takayoshi Ozaki; Minoru Suzuki; Teruaki Akamatsu; Tetsuzo Akutsu

The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb <6 mg/dl) for more than 2 years. The prototype implantable model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.


Asaio Journal | 1997

More Than 1 Year Continuous Operation of a Centrifugal Pump With a Magnetically Suspended Impeller

Chisato Nojiri; Toshihiko Kijima; Jun Maekawa; Kunio Horiuchi; Takayuki Kido; Tomoko Sugiyama; Takehisa Mori; Naoya Sugiura; Takehiko Asada; Shimane H; Nishimura K; T. Ban; Teruaki Akamatsu; Takayoshi Ozaki; Ito H; Minoru Suzuki; Tetsuzo Akutsu

The authors have been developing a centrifugal pump with a magnetically suspended impeller (MSCP) designed for total artificial heart and long-term ventricular support. The MSCP consists of a magnetic bearing, an impeller and housing, and a driving motor. The impeller is suspended by a magnetic bearing, therefore providing contact free rotation of the impeller inside the pump. This study was designed to evaluate long-term durability and nonthrombogenicity of the MSCP in a chronic sheep model. The blood contacting surfaces of the pump and conduits were completely modified by a heparin immobilization technique (Hepaface). The MSCP was placed paracorporeally as a left heart bypass between left ventricle and descending aorta in three adult sheep. Coumadin was given orally to maintain prothrombin time at 15–20 sec. The coagulation and hematologic parameters, including plasma free hemoglobin, were periodically monitored throughout the experiment. Under daily movement in the cage, the pump could produce average flow rates of 3–6 L/min (50–100 ml/kg) at 1,700–2,000 rpm. Although the arterial pulse contour decreased, there was no physiologic deterioration. The axial impeller excursion monitored by a position sensor was <25 μ. Plasma free hemoglobin level remained at <5 mg/dl throughout the experiment. There was no increase in the motor current, which indicates no massive thrombus formation around the impeller. One experiment was terminated at 70 days due to Hall sensor dysfunction of the motor. The retrieved pump was entirely free from thrombus formation. There was no detectable thrombus formation inside the pump or the inflow and outflow conduits. Hematologic, renal, and hepatic parameters remained within the normal range throughout the experiment. The other two sheep have survived for more than 395 and 41 days without major complication. These studies demonstrated that the MSCP has significant potential for long-term use.


Asaio Journal | 1998

Results of Chronic Animal Experiments With a New Version of a Magnetically Suspended Centrifugal Pump

Kazunobu Nishimura; Satoshi Kono; Takeshi Nishina; Teruaki Akamatsu; Tomonori Tsukiya; Chisato Nojiri; Takayoshi Ozaki; Masashi Komeda

We have developed a magnetically suspended centrifugal pump (MSCP) for long-term ventricular support. This study reports results of chronic animal experiments using a new version of the MSCP. Three sheep weighing 50-70 kg were used in this study. A left heart assist system was established with cannulas into the descending aorta and the left ventricular apex. In two sheep the MSCP was positioned outside the body and in one sheep implanted on the chest wall. The pumping flow was estimated by the motor current and motor speed. The temperature of the pump and the muscle near the pump was recorded for 10 days after operation. The duration of continuous pumping was 60, 140, and 230 days+ (ongoing), respectively. The cause of termination was infection associated with thrombus formation in the first, and failure of magnetic suspension in the second sheep. No thrombus or embolus was observed after sacrifice of the second sheep. The third sheep has been going well despite skin necrosis around the pump pocket. The estimation of pumping flow was reliable even at 140 days. Temperature of the pump surface was 42 degrees C immediately after the operation and gradually reduced to 41 degrees C. The MSCP is a reliable pump for long-term circulatory assist.


Journal of Artificial Organs | 1999

Development of Terumo implantable left ventricular assist system (T-ILVAS) with a magnetically suspended centrifugal pump

Chisato Nojiri; Toshihiko Kijima; Jun Maekawa; Kunio Horiuchi; Takayuki Kido; Tomoko Sugiyama; Takehisa Mori; Naoya Sugiura; Takehiko Asada; Takayoshi Ozaki; Minoru Suzuki; Teruaki Akamatsu; Tetsuzo Akutsu

The research group of Terumo, NTN, and the Setsunan University have been developing an implantable left ventricular assist system (T-ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The present study describes recent progress in the development of the T-ILVAS, focusing on ex vivo and in vivo evaluations of the prototype MSCP. The MSCP is composed of four parts: a magnetic bearing, an impeller, a housing, and a DC burshless motor. The impeller is suspended by a magnetic bearing, thus providing contact-free rotation of the impeller inside the pump. The prototype MSCP was placed paracorporeally in three sheep and implanted intrathoracically in two sheep to evaluate its long-term durability and nonthrombogenicity. One sheep implanted ex vivo with the paracorporeal MSCP (Model I) survived for 864 days without any mechanical failure or thromboembolic complications, and with negligible hemolysis. The implantable Model II pump was evaluated ex vivo in two sheep and intrathoracically implanted in one sheep. These experiments were terminated 70, 79, and 17 days after implantation due to mechanical failure caused by blood leakage through the intrahousing connector of the Model II pump. However, there was no intradevice thrombus formation in any of the retrieved pumps. The dual connector system was then introduced to the Model II pump (the modified Model II), and the pump was intrathoracically implanted in a sheep. The sheep survived for more than 14 months without major complications, and the study is being continued. The preliminary chronic animal experiments demonstrated improved durability and nonthrombogenicity of the MSCP, with a low hemolysis rate for up to 864 days. Thus, the MSCP has significant potential for longterm application as an implantable circulatory assist system. Further developments toward a totally implantable system, including an implantable controller and a transcutaneous energy/information transfer system, are under way.


Archive | 2007

Bearing device for wheel

Kenichi Iwamoto; Takayoshi Ozaki; Takashi Koike


Archive | 2008

Sensor-equipped bearing for wheel

Takayoshi Ozaki; Tomomi Ishikawa; Kentarou Nishikawa


Archive | 2001

Fluid pump apparatus

Takayoshi Ozaki; Minoru Suzuki


Archive | 2000

Magnetically levitated pump

Takayoshi Ozaki; Minoru Suzuki


Artificial Organs | 2001

Development Status of Terumo Implantable Left Ventricular Assist System

Chisato Nojiri; Toshihiko Kijima; Jun Maekawa; Kunio Horiuchi; Takayuki Kido; Tomoko Sugiyama; Takehisa Mori; Naoya Sugiura; Takehiko Asada; Wataru Umemura; Takayoshi Ozaki; Minoru Suzuki; Teruaki Akamatsu; Stephen Westaby; Takahiro Katsumata; Satoshi Saito

Collaboration


Dive into the Takayoshi Ozaki's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge